Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-AOC 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹38.7 L+₹3.8 L (11.0%)Rejected-Finance 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹47.8 L+₹12.9 L (37.0%)Rejected-Finance H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹48.5 L+₹13.6 L (38.9%)Rejected-Finance | L4 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹69,960
Closing Date
5 Oct 2024, 6:00 pmClosed
GE (MES) ROORKEE
Garrison Engineer Roorkee
REPAIR AND MAINT TO INTERNAL WIRING INCL SUB MAIN WIRING, FANS, GEYSERS, COOLING APPLIANCES AND OTHER CONNECTED ITEMS FOR OTM AND MD ACCN AT RTS AND D SAHARANPUR UNDER GE ROORKEE
2024_MES_671917_1
8392/422/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
SAHARANPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (MES) ROORKEE
₹69,960
Yes
23 Dec 2024
4 Sept 2024
7 Oct 2024
4 Sept 2024
5 Oct 2024
21 Sept 2024
Amount
Taking down copper/aluminium point wiring (light, fan, socket or power) complete incl fixtures and fittings such as switches, ceiling rose, pendant, regulator, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (Credit for above items should be as per conditions separately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
M & L for Point wiring with PVC insulated PVC unsheathed electric (FRLS-H) cable 1100V grade single core having multi stranded copper conductor of size 1.5 Sqmm nominal cross sectional area in & including non metallic rigid PVC conduit ISI marked medium grade not less than 20mm dia with all conduit accessories in concealed wiring system by cutting of wall and making good disturbed surface of wall (cutting except on ceiling for fan point only, on ceiling instead of pvc conduit surface casing caping will be used) & 1.5 sqmm green PVC insulated unsheathed copper conductor as a earth wire connected to earth dolly by providing lugs including sunk in pressed steel terminal boxes (normal and moduler type) of 1.6 mm thick and including bakelite sheet cover or hylam board of 2.8 mm thick including cutting holes for switches, sockets, regulators etc as per requirement including fixing with machine screw, washer etc for the following :-
One light/fan point controlled by one one way switch
One bell/buzzer point controlled by one push button
One 3/5 pin socket outlet 5 Amp on the same board with other swithes.
One 3/5 pin 5 Amps socket outlet on indepandant board.
All as per item No 2 above here in before but wiring in existing conduit for the following :-
One light/fan point controlled by one one way switch
One bell/buzzer point controlled by one push button complete
One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
One 3/5 pin 5 Amps socket outlet on indepandant board.
All as per item No 2 above here in but with 2.5 Sqmm (nominal area) FRLS-H cable PVC for 15 Amp 3/5 pin socket power point including 2.5 Sqmm copper conductor green as colour for earth contineuity.
All as per item No 2 above here in but in existing conduit with 2.5 Sqmm (nominal area) FRLS-H cable PVC for the 15 Amp 3/5 pin socket power point including 2.5 Sqmm copper conductor green as colour for earth contineuity all as specified.
M&L for point wiring complete with PVC insulated and unsheathed, flame retardant low smoke (FRLS-H) 1100 volt grade electric cable of 1.5 sqmm (nominal area) with stranded copper conductor single core in and including rigid PVC surface conduit not less than 19 mm dia in existing building, clip, with suitable MS terminal boxes (not less than 1.0 mm thick )and including earth dolly with 3 mm thick sheet top cover of approved colours including 1.50 sqmm green stranded copper conductor as continuous earth wire with all accessories including lugs required, complete all as specified and as directed.
One light/fan point controlled by one switch
One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
Description all as per item No 6 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke (FRLS-H) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 2.5 sqmm green stranded copper conductor as continuous earth wire with lugs.
Supply and fixing in replacement of Sub main wiring with two runs of single core PVC insulated and unsheathed multistranded, copper conductor (FRLS-H) cable of size 4.0 sqmm LT, 1100V grade, down through and incl adequate sizes PVC non metallic conduit of 20mm/approprite dia with accessories and fittings and one run of 4 sq mm single core multi stranded copper conductor cable as earth continuity conductor. Two runs of cable one run of earth wire and one run of PVC non metallic conduit of 20mm/ approprite dia shall be measured as one run length, Cable required for connection to DBs shall deemed to be incl and shall not be measured separately. Earth wire shall run inside the conduit pipe complete all as specified and directed. (Note :- Extra length of cable required for connection to MCBs shall deemed to be included in unit rate)
-DO- All as per item no 8 above but 2 core 6 sqmm
S&F switch piano flush type polycarbonate single pole one way 5 Amps complete all as specified and directed..
S&F switch piano flush type polycarbonate single pole one way 15 complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5 Amps flush type complete all as specified and directed.
S&F socket outlet polycarbonate 2 in 1, 3 pin 5/15 Amps flush type complete all as specified and directed.
S&F bell push flush type 5 Amps complete all as specified and directed.
S&F Ceiling rose 3 phase/PVC/polycarbonate, insulated body complete all as specified and directed.
S&F steped type electrronic fan regulator flush type complete all as specified and directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings with 9 watt LED bulb PAG series B-22 base complete all as specified and directed.
S&F Modular switch 1 way 6A, 1 module complete all as specified and directed.
S&F Modular switch 1 way 10A, 1 module complete all as specified and directed.
S&F Modular switch 1 way 16A, 1 module complete all as specified and directed.
S&F Modular Bell push 6A 1 module complete all as specified and directed.
S&F Socket, 6A - 2/3 pin combined 2 module complete all as specified and directed.
S&F Socket, 6A/16A - 2/3 pin combined 2 module complete all as specified and directed.
S&F Fan step regulator, 120W - 2 module complete all as specified and directed.
S&F White cover plate with frame, 1 module complete all as specified and directed.
S&F White cover plate with frame, 2 module complete all as specified and directed.
S&F White cover plate with frame, 3 module complete all as specified and directed.
S&F White cover plate with frame, 4 module complete all as specified and directed.
S&F White cover plate with frame, 6 module complete all as specified and directed.
S&F White cover plate with frame, 8 module complete all as specified and directed.
S&F modular metal flush box 1/2 module complete all as specified and directed.
S&F modular metal flush box 3 module complete all as specified and directed.
S&F modular metal flush box 4 module complete all as specified and directed.
S&F modular metal flush box 6 module complete all as specified and directed.
S&F modular metal flush box 8 moudle complete all as specified and directed.
S&F electric bell ding dong single phase, AC 230 volts complete all as specified and directed.
S&F of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 Amps rated busbar 12 way complete all as specified and directed.
S&F of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 Amps rated busbar 8 way complete all as specified and directed.
S&F of double door MCB distribution boards sheet steel, powder coated DBs suitable for MCBs fitted with bus bar, neutral link earth bar and din rail Single phase and neutral confirms to IS : 13032-1991DB, 240 Volts 200 Amps rated busbar 4 way complete all as specified and directed.
S&F of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof TPN 4 way IP 43 (double door) with 200 Amps rated copper bus bar neutral bar, earth bar, triple pole and neutral 415volts, flush to wall complete all as specified and directed.
S&F of Distribution board (DB) made out of sheet metal enclosure (CRCA sheet) dust and vermin proof vertical TPN 8 way, with MCCB of 160A, with breaking capacity 36 KA, IP 43 (double door) with 200 Amps rated copper bus bar neutral bar, earth bar, triple pole and neutral 415volts, flush to wall complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single pole and current carrying capacity 40 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed..
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & nutral and current carrying capacity SPN 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of single pole & nutral and current carrying capacity SPN 40 to 63 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing 415V 10KA 'C' curve miniature circuit breaker (MCB) of TPN 40 To 100 AMP and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
S&F single pole and neutral enclouser with a two pin and earth plug and socket complete with one single pole MCB of rating 20 Amps 240 volt grade complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to galvanised earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel and connecting to main switch or switch board complete and incl PCC masonry pit of 300x300x300mm interior dimentions in PCC 1:2:4 type B1 RCC cover with GI handle, charcoal dust and common salt 15cm in layers all round the earth plate, 20mm dia GI watering pipe, a funnel with wire mesh should be provided on top of watering pipe complete all as specified as per electric plate No 3 of SSR 2009 including testing after completion complete all as specified and directed.
All as abobe item but earthing strip 25mm x4mm thick
Supply, Installed & fix maintenance free earthing copper bonded steel earth rod of 10 feet long having diameter of 17.2mm with copper bonding thickness of 250 micron,UL listed,CPRI Tested at 25 KA fault current for one second and is provided with universal clamp made of SS earth enhancing compound shall be of 30kg/pit(resistivity is less than 0.12 Ohm meter) tested as per IEC 62561-7.The bove arrangements shall be provided with heavy duty earth poly plastic pit cover of 6000 kg load bearing capacity (Size:270 x 40 200mm) complete, using GI earth earth Strip 32 x 6 mm connected to earth rod at one end by means of bolts, nuts, check nuts and washers and connected to metallic bodies of HT/LT all as specified and directed. Note :- On testing after completion of job, if desired earth resistance (i.e. less than five Ohm) is not obtained, the earthing shall be redone by the contractor without any extra cost to Govt.
All as above but using copper wire 6.0 sqmm dia
Supply and fixing in replacement of 1100 volt grade heavy duty cable PVC insulated solid aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connectiuons suspended by insulating hangers not more than 1 meter apart including 4 mm dia suspension wire, twin core cable flat or circular of size 6 Sqmm complete all as specified and directed.
All as above but cable size 10 sqmm
S&L in replacement of XLPE insulated armoured heavy duty electric cable with stranded aluminum conductor 1100 volt grade cross sectional area 10 Sqmm and 2 core complete all as specified and directed.
All as above but 16 Sqmm, 2 core
All as above but 25 Sqmm, 3.5 core
Supply and fixing house service bracket in replacement (hook type) complete with 3.0 mtrs long GI pipe 40 mm dia medium grade two nos 90 degree bends, MS hook and stay or guy complete all as specified and directed.
M&L for laying GI tubing light grade 40 mm dia with all fittings for cable protection including GI clamps nut bolts and washer etc complete all as specified and directed.
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
M & L for dry sand cushioning to underground cables with 8cm thick before laying of cables and 15cm thick after laying and stretching of cable complete all as specified and directed. (Note:- Punning thickness shall be measured)
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
S&F in repair bulk head fittings IP-65, surface mounted comprising LED luminaire 9/10W of high brightness complete all as specified and directed.
Supply and fixing in replacement Wall light fixture lantern made up of polycarbonate suitable for 9 watt LED bulb complete with 9 watt LED bulb including connection with all necessary accessories complete all as specified and directed.
S&F in replacement of LED Tube light fitting 20 Watt surface and wall mounted LED batten, extruded polycarbonate diffuser & integrated electronic driver complete with all accessories internally prewired and incl connecting up three core single wire complete all as specified and directed.
Supply and fixing in replacement of building security lights with new generation energy saving & environment friendly long life versatile pressure die-cast aluminium IP65 roadway luminaire with high power LEDs as light source & exclusively designed polycarbonate cover alongwith electronic driver type street light fitting 35/36 watt capacity LED and including all accessories duly pre-wired, fixing on existing bracket with nut, bolts & washers as required at site for fixing of street light on LT pole/ wall complete all as specified and directed.
S&F in replacement of Gate lights/post top light with 20 Watt LED light as light source, IP-65, made of spun aluminium landscape luminaire suitable for fixing on 40/50 mm GI pipe on the gate post including connection with all necessary accesssories complete all as specified and directed.
Supply and fixing decorate gatelight globe (round size) made up of high grade unbreakable polycarboneate material suitable for retrofit LED lamp B22 base complete all as specified and directed.
S&F LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
S&F in repair LED luminaire 600 mm x 600mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Labour only for attending and repairing day to day complaints of internal electrification and repairing in situ by skilled electrician alongwith a helper and making functional faulty points i.e. fixing necessary electric fittings (switch, socket, holder, Tube light, bell, regulator, Capcitor etc) complete all as specified and directed at site. (Note : - Point wiring will be measured and paid separately under appropriate item, fixing in repairs will be measured in appropriate item.)
Note :- (a) The trade men shall be equipped with all necessary Electrician tool kit, the rate of the same shall be included in the quoting rates. (b) The trade men shall report at complaint cell at 0930 Hrs. (c) Old Unsv items retreived against new shall be taken on schedule of credit (d) Replaced electrical fittings will be measured as per site requirement. (e) Fixing in repairs items will be supply by Department. (f) While quotating rates against item 8 hrs of complaint duty for both electrician and helper shall be considered.
Supply only bell push flush type 5 Amps
Supply only Ceiling rose 3 phase/PVC/polycarbonate, insulated body.
Supply only steped type electrronic fan regulator switch type all as specified.
Supply only steped type electrronic fan regulator socket type all as specified.
Supply only moudular switch 1 way 6 A, 1 moudle
Supply only moudlar fan reuglator 120W, 2 module
Supply and fix in replacment of single phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50 Hz, confirming to IS-13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. (Note - Old meter to be deposit in MES store and takenon ledger charge)
Supply and fix in replacement of three phase electronic meters temper proof LCD display with polycarbonate cover 230 V, 10-60 Amp, accuracy class-I 50 Hz, confirming to IS-13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specified and directed. (Note - Old meter to be deposit in MES store and takenon ledger charge)
S&F in replacment of PVC rectangular block for mounting, switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 100mmx100mm and 50 mm deep complete all as specified and directed.
S&F in replacment of PVC rectangular block for mounting, switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet cover of size 175mmx100mm and 50 mm deep complete all as specified and directed.
Supply and fix double pole, RCBOs of 40Amp, 30mA for protection against earth leakage, overload & short-circuit protection in MCB DBs complete all as specified and directed.
S&F round shape 16 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix 80 watt LED well glass clear diffuser light, with provision of deidicated mounting eyebolt with PDC aluminium housing with polycarbonate diffuser complete all as specified and directed..
Supply and fix 100 watt LED highbay light, with provision of deidicated mounting eyebolt /bracket built in PDC aluminium housing, SMD LED array with integrated lens polycarbonate cover complete all as specified and directed..
S&F of landscape cylindrical shape LED bollard light with integrated driver, including establishing on ground connecting to the existing cable and make it functional all as specified and directed at site.
Taking down ceiling/exhaust/wall mounted fan of any size and sweep from its position dismantling fan for servicing and overhauling of following type and size of Fan by dismantling carefully and removing & changing unserviceable parts, dust & grease, cleaning of internal parts with kerosene oil, washing, checking of alignment of shaft, oiling and re-greasing of bearing/bushes including re-assembling, re-fixing in existing position and connecting to electrical system, testing etc complete at site all as specified & directed Engineer-in-Charge.(Note : Bearing, bush, condenser and painting shall be measured and paid separately.)
Ceiling Fan complete up to 1400 mm Sweep
Ceiling fan complete 1200 mm Sweep
Exhaust Fan up to 450 mm Sweep
Wall mounted fan up to 400 mm sweep
Supply & fix following items for replacement of defective accessories :-
Ball bearing for ceiling Fan No 6201
Ball bearing for ceiling Fan No 6202
Ball bearing for ceiling Fan No 6203
Ball bearing for ceiling Fan No 6204
Ball bearing for exhaust Fan of 300/450 mm sweep.
Ball bearing for wall mounted Fan of 300/450 mm sweep.
Gun metal bush suitable for 1200/1500 mm sweep ceiling Fan.
Fan condenser of capacity 2.5 mfd epoxy filled type
Fan condenser of capacity 3.15 mfd epoxy filled type
Fan condenser of capacity 4 mfd epoxy filled type
Rubber bush with split pin for ceiling fan
Armature shaft for Ceiling Fan
Materials and labour for rewinding of following Fans with heavy duty super enameled copper wire of existing gauge including all insulation materials, varnishing, heating etc complete all as as specified and directed :-
Ceiling Fan complete 1200 mm Sweep
Ceiling Fan complete 1400 mm Sweep
Exhaust Fan upto 350 mm Sweep
Exhaust Fan 350 to 450 mm Sweep
Wall mounted fan upto 400 mm sweep
M&L for painting of following Item with two coats of DUCO paint (ISI grade) white using spray machine spray painting with marking fan number including cleaning, washing and preparation of old painted surfaces complete all as as specified and directed :-
Ceiling fan upto 1400 mm sweep complete.
Ceiling fan upto 1200mm sweep complete
Exhaust fan upto 450 mm sweep with black paint.
Wall mounted fan upto 400 mm sweep.
S&F canopy for ceiling fan of existing size & make as required at site complete all as as specified and directed.
Supply and replace down rod heavy grade 15 mm dia complete with drilling holes , cutting making threads as per requirement length up to 1.25 mtr, white paint complete all as as specified and directed.
S&F exhaust fan blade set complete suitable for 300/350/450 mm size any make /type or as required at site complete all as as specified and directed..
S&F in replacement hanging clamp with bolt, nut, washer, of appropriate size suitable for down rod of ceiling fan any sweep, specification as per existing or samples complete all as as specified and directed.
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz 1200, Copper winding of sweep 300m complete all as as specified and directed.
Supply and fix PVC insulated multistrand Copper Cable 3 core size 1 sq mm, in white colour for light fittings and for fan connections from ceiling rose to electric fittings complete all as as specified and directed.
Taking down carefully geysers of any make and capacity, transporting to MES E/M yard for dismantling the same for inspection, taking out all unserviceable and burnt spare parts, de-scaling and cleaning of tank thoroughly with washing compound or liquid solution, applying one coat of milky white synthetic enamel paint with sprayer after preparation of surface, writing work as per existing pattern with black synthetic enamel paint and re-fixing of geysers at its original position complete all as specified and directed. Note : (a) Spare parts shall be measured and paid separatly under respective item of this schedule,however minor items which are not catered in this schedule, the cost of the same shall be deemed to be included inthe unit rate of these items. (b) Minimum one technecian (One Electrician and One Plumber) and one helper with all types of tools and plants/veh etc. should report to E&M yard for repair of geyser including taking down/ /fixing of same. (c) Repair works will be carried out at workshop E&M yard. (d) Repair works of geyser should completed and refixed the same with in 12 hrs after receipt of complaint slip. If the contactor found fail to do complaint, an amount of Rs. 500 for each complaint will be deduct from the RAR bill.
Supply of heating element 2.0 KW, 220 / 230 Volts any type / shape (Cup type round) ISI marked complete all as specified and directed.
Supply of heating element 2.0 KW, 220 / 230 Volts any type / shape (Cup type triangular) ISI marked complete all as specified and directed.
Supply of Thermostat cone type, ISI marked complete all as specified and directed.
Supply of Thermostat switch coil type ISI marked complete all as specified and directed.
Supply of Brass Head Assembly having 8 to 9 holes suitable for 25 litres capacity geyser complete all as specified and directed.
Supply of head assembly along with integrated heating element and thermostate ISI marked complete all as as specified and directed.
Supply of Brass Safety plug ISI marked suitable for 25 / 35 / 50 litres capacity geysers complete all as specified and directed.
Supply of mild steel spacer ring suitable for 25 / 35 / 50 litres capacity geyser complete all as specified and directed.
Supply of round shaped rubber gasket having 8 to 9 holes, suitable for 25 / 35 / 50 liters capacity geyser complete all as specified and directed.
S&F Brass chromium plated connection 15mm, 450mm long with cromium plated adopter and washer at both ends complete all as specified and directed.
S&F Brass chromium plated connection 15mm, 600mm long with cromium plated adopter and washer at both ends complete all as specified and directed.
Supply & fixing Element holding clamps suitable for 25 / 35 / 50 Liters capacity geysers complete all as specified and directed.
S & F in repairs 450 mm long heavy duty PVC connection suitable for cold water supply with two Nos. PTMT nuts alongwith PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
S & F in repairs 600 mm long heavy duty PVC connection suitable for cold water supply with two Nos. PTMT nuts alongwith PVC washer suitable for 15 mm bore pipe line complete all as specified and directed.
Supply & fixing Neon lamp (Red & Green) round / square in shape suitable for 25 / 35 / 50 liters capacity geysers complete all as specified and directed.
Supply and Fixing as in replacement ISI marked pressure release valve brass body suitable for 15 mm bore pipe line for cold water connection in storage geyser complete all as specified and directed.
M & L for repairing of inner copper tank / container of geyser by brazing not exceeding 4 cm in length complete all as specified and directed.
Supply and fixing of ISI marked inner shell made of stainless steel suitable for 25 Liters capacity geyser complete all as specified and directed.
Supply and fixing PVC insulated round copper wire 3 core 2.5 Sqmm for making connection from storage geyser to industrial / power socket complete including removal of existing old damaged wire all as specified and directed.
Supply and fix Plug Top 3 pin 15 Amps for storage geyser including removal of existing plug top complete all as specified and directed
Taking down carefully solar water heating system of capacity 200 to 600 liters per day of any make, dismantling the same for inspection, taking out all unserviceable and burnt spare parts, de-scaling and cleaning of stainless steel tank thoroughly with washing compound or liquid solution, applying one coat of synthetic enamel paint with sprayer after preparation of surface, writing work as per existing pattern with black synthetic enamel paint, including replacement of unservicable element, tore glass tube and heat resistant insulating material as per existing sizes, type and watt and re-fixing of solar water heating system at its original position complete all as specified and directed.
Supply and fix GI pipe medium grade15 mm for making connection from storage geyser to bib tap complete including shaddles and screws all as specified.
Taking up or down (from wall/trenches/floor) existing 15mm GI steel tubing and connections, including cleaning for re-fixing or removal to store complete all as as specified and directed.
Supply and fix Bib taps, cast iron with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixedBib tap 15 mm for hot water supply point complete all as as specified and directed.
Supply and fix Angle valve cromium plated, screwed down high pressure, with or without lettered Hot and cold with long screwed shanks and fly-nuts, screwed for iron pipe complete all as as specified and directed..
Supply and fix pressure release valve suitable for 25 mm dia pipe for solar hot water supply made out of gun metal complete all as specified and directed.
Supply and fix Solar Water heating element 3 KW suitable for hot water storage tank including disconnection existing element and making new electric connection complete all as specified and directed.
S&F Rotational moulded polyethylene PVC water storage tanks of capacity 500 Ltrs (cylindrical vertical with closed top) hoisted and fixed in replacment in position all as specified in SSR part-I complete, all as specified and directed at site.
Taking out Window/Split type Air conditioner of any make and capacity from position and cleaning the complete cooling coil & condenser coil with chemical base solution and water including servicing, oiling, greasing complete air conditioner checking of blower motor, electrical connection and re-fixing the same on its original position and testing complete. (If any spare is required to replaced the same to be measured and paid separately under supply only item)
Removing defective window/Split type air conditioner of any make and capacity from various locations and transporting to contractor workshop to carry out necessary repair as mentioned in respective item including cleaning the air conditioner with water and air pressure and to replace un-serviceable spares parts and re-fixing at various locations after repairing including testing on load at site all as directed. (All spares compressor, fan motor, relay, capacitor, over load, shall be measured and paid separately under supply only item)
Removing unserviceable burnt sealed compressor from Air conditioner and fixing only new rotary compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified & directed. Note:- i) Rotary compressor shall be measured and paid separately under supply only item) ii) If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate.
SUPPLY ONLY ITEM Note : i) The items for fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same will not be paid to contractor. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
New Rotary type compressor of Capcity 1.5 TR.
New Rotary type compressor of Capcity 2.0 TR.
FHP motor of capacity 1/5 to 1/18 single phase 920/1440 RPM with capacitor suitable for window/split type AC of any make & capacity.
Starting capacitor 80-100 MFD/ 100-120 MFD/120-150 MFD.
Running Capacitor 45/50 MFD or 45+6 / 50+6 MFD.
Running Capacitor 36 MFD / 36+6 MFD.
Starting relay suitable for 1.0/ 1.5 / 2.0 TR Compressor
Air filter Nylon/plastic type suitable for window / Split type A/C.
Thermostat suitable for window / Split type A/C.
Front grill for window type AC of any model all as required at site and as directed.
Condenser/cooling fan blade suitable for window type AC of any make & capacity
Blower unit only suitable for window AC of any capacity & make
PCB card along with remot suitable for window/split type AC of any capacity & make
Digital circuit plate along with remot suitable for windoe/split type AC of any capacity & make
Blower Motor both end coupling complete for Indoor split AC 1.5 / 2.0 TR of any make
Indoor door unit complete with cooling coil & remot suitable for split type AC of capacity 1.5 TR
Indoor door unit complete with cooling coil & remot suitable for split type AC of capacity 2.0 TR
Outdoor door unit complete with condeser coil & FHP motor suitable for split type AC of capacity 1.5 TR
Outdoor door unit complete with condeser coil & FHP motor suitable for split type AC of capacity 2.0 TR
Copper liquid line filter two way / One way.
Contactor suitable for outdoor unit of split type AC of any capacity & make
PVC rounded 3 core, 4.0 Sqmm copper work shop cable.
New Reciprocating type compressor of Capacity 1.5/2.0 TR
Copper pipe suitable for connection of window / split AC of size 1/4'' or 3/8'' (inch) with insulation slleve Foam Heat insulation complete all as specified and directed
Copper pipe suitable for connection of window / split AC of size 1/2'' or 5/8'' (inch) with insulation slleve Foam Heat insulation complete all as specified and directed
Supply & replacement wiring loom complete suitable for window / split type air conditioner complete all as specified and directed
M&L Installation, commissioning and fixing of reverse cycle valve any make suitable for window/Split type AC 1.5/2.0 Ton capacity including required copper pipe and two way switch complete all as specified and directed NOTE:- Gas charging if required shall be paid separately under respective item of BOQ.
M&L for rewinding of stator of FHP motor of size 1/5 to 1/18 single phase 920/1440 RPM with super quality of copper wire of existing size complete with varnishing, backing, testing including painting with one coat of synthetic enameled black paint complete all as speified and directed.
Cutting damaged tray from window type air conditioners and replacing with existing shape and size including all necessary work such as welding, nut, bolts, drilling etc suitable for 1.5 / 2.0 TR Air conditioners complete all as as specified and directed.
M & L for gas charging M/R-12 / M/R-22 / R-134a / R410a / R32 to the following appliances including removal of old fitter, copper tubing / capillary and replacement of new filter, capillary, short piece of copper tubing of equipment and leakage testing of the same on full load after re-installation of the same at site complete all as specified and directed: -
Window type air conditioner 1.5 Ton capacity of any make.
Split type air conditioner 1.5 Ton AC capacity of any make.
Refrigerator Capacity 300 to 320 Ltr of any make
Water cooler 40/80 Ltr capacity
Water cooler 150 Ltr capacity
Material and labour for Minor denting and one coat spray paint of window type Air conditioners mentioned item No.1 above complete internally and externally with suitable super enameled synthetic enameled paint of required colour complete all as directed by the Engineer-in-Charge.
Supply and fix in replacement of modular MCB protected plug and socket board in sheet steel enclosure with 25 Amp rated mini MCB and 25 Amp rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board including taking down existing unserviceable plug & socket board of any description and making good with cement plaster, putty and paint to match with the existing surface all as specified.
Taking out old U/S voltage stabilizers of capacity 0.5 KVA to 5 KVA from MES store/site and repair the same in MES work shop (if the transformer found burnt, the in same shall be re-winded in the workshop of contractor as directed.
SUPPLY ONLY OF THESE ITEMS REQUIRED TO MAINTAIN THE SERVICES OF STABLIZER OF ABOVE ITEMS
Main relay 24 Volts, 25 Amps.
Main Control circuit (PCB)
Output terminal 32 Amps
Replacement of Censor Transformer
Voltmeter anolog / Digital type as per sample of any make & capacity
Time delay 2-3 minute over low voltage 180 volts AC and high voltage 260 Volt AC.
Taking out old burnt winding work and re-winded with super enameled copper winding wire (existing size) for 5 KVA voltage stabilizers including all necessary insulating material and testing complete.
All as per item No. 137.00 above but capacity of voltage stabilizer 4 KVA/3KVA.
All as per item No. 137.00 above but capacity of voltage stabilizer 2 KVA / 1KVA.
Painting of voltage stabilizers with one coat of synthetic enameled paint (existing colour) after proper cleaning and scraping old painted surfaces and write GE (MES) Roorkee on voltage stabilizers in block letters with white paint complete as directed.
S&F sheet metal enclosure with metal clad socket and earth plug with one number MCB SP of size 20/32 Amp 'c' series, single phase including connecting complete all as specified.
Transporting refrigerator of any make and capacity from MES Store Yard to contactor’s workshop for carrying out necessary repair as mentioned in respective items including back to MES Store Yard after repair and testing complete.
Removing unserviceable burnt sealed compressor from refrigerator and fixing only new sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified & directed. Note:- (Sealed unit compressor shall be measured and paid separately under supply only item) ii) If any item required to made equipment functional like cappliary,copper pipe ect is deemed to be included in coated rate.
SUPPLY ONLY ITEMS OF REFRIGERATOR IN RESPECT OF ABOVE ITEM Note : i) The items for fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same shall not be paid to contractor. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
New sealed compressor of size 1/6 HP to 1/8HP suitable for refrigerator / Deep freezer of capacity 165 Ltr to 310 Ltr.
Relay suitable for refrigerator/Deep freezer 165 Ltr to 310 Ltr capacity.
Over load suitable for refrigerator/Deep freezer 165 Ltr to 310 Ltr
Thermostate suitable for refrigerator/Deep freezer 165 Ltr to 310 Ltr capacity.
PVC freezer door suitable for refrigerator any make & capacity.
Chiller tray of any make and capacity suitable for refrigerator.
Vegitable tray suitable for refrigirator of any make & capacity
Shelves suitable for refrigirator of any make & capacity
Magnetic rubber door gasket suitable for refrigerator of any make & capacity.
PVC insulated and PVC sheathes rounded 3 core, 2.5 Sqmm copper work shop cable.
Freezer Box / Chiller Assembly complete with coil and chamber of any make and capacity suitable for refrigerator.
Screw/Pin type bulb suitable for refrigerator of any make & capacity.
Taking down/out water cooler of any Make and capacity from various locations transporting to contractor’s workshop for carrying out repair as mentioned in respective items of Schedule ‘A’ including transporting back after repair fixing at site re-connecting electrical & water connection & its re-testing on load all as specified & directed.
Removing unserviceable burnt sealed unit compressor from water coolers and fixing only sealed unit compressor of any capacity including necessary welding the same with existing refrigerant pipe, supply & charging refrigerant gas including testing all as specified & directed by Engineer-in-Charge. Note:- (Sealed unit compressor shall be measured and paid separately under supply only item) ii) If any item required to made equipment functional like cappliary, copper pipe ect is deemed to be included in coated rate.
Removing un-serviceable burnt FHP motor from water cooler and supply & fixing new FHP motor with suitable fan blade single phase 1/5 to 1/35 HP suitable for up to 150 Ltr capacity water coolers including testing all as specified and directed.
Taking out water cooler of any make and capacity from position and cleaning the complete condenser coil & storage tank with chemical base solution and soda water including servicing, oiling of FHP motor checking of electrical & water supply connection and re-fixing the same on its original position and testing complete up to satisfaction complete all as as specified and directed.
SUPPLY ONLY ITEMS OF WATER COOLER Note : i) The element of fixing is deemed to be included in respective Schedule ‘A’ Items) ii) If any item not consumed during the contract period the same shall not be paid to contractor. iii) All replacement for failed/unserviceable compressor shall be guaranty of not less than 12 months of all such replacement.If any compressor burnt during guaranty period the same has replaced by contractor without taking any extra cost including supply & charging refrigerent gas.
New sealed unit compressor suitable for water cooler 40 / 80 Ltr
Relay & OLP suitable for water cooler of any make & capacity
Thermostat switch suitable for water cooler any make & capacity
Push taps chromium brass body inner/outer thread suitable for water cooler capacity up to 40/80 Ltr (as per sample)
Fan motor blade size 12" sweep suitable for FHP motor of water cooler
PVC flexible pipe transparent 15mm/20mm dia dia (as per sample)
PVC float valve 15 / 20 mm dia with rod & ball. Make: Prayag or equivalent.
Running Capacitor 4 MFD.
3 pin plug top one way 5 Amp, 240V.
3 pin plug top 15 Amp, 240V.
Submersible water lifting pump of capacity 18 watt suitable for 1.25 M head 230 V AC.
Kit fan motor 1/6 HP suitable 450 mm Sweep 1350 / 1400 RPM.
Industrial type three pin metal clade socket of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser
Industrial type three pin metal clade plug top of capacity 20 Amps 230 Volt single phase suitable for sheet metal enclouser
M&L Industrial type Heat Pillar tower type suitable for winter heating of capacity 2 x 750 watt, stainless steel body oscillating quartz type of size 270mm x 210mm x 900mm complete all as as specified and directed.
Supply & Fix condenser coil complete with copper tube and aluminium fins suitable for water cooler of any make and capacity complete all as as specified and directed.
Material and labour for cutting worn out bottom and sheet base frame including MS legs from water cooler of any make and capacity and fixing the same with PGI sheet 16 SWG of existing size and new angle iron base from (angle size iron 50 x 50mm x 6mm) and legs including necessary gas welding and providing nut/bolts etc complete all as as specified and directed.
Material and labour for minor denting and painting of water cooler complete by spray painting super enameled with one coat of enamel paint after proper scraping of old painted surface complete all as as specified and directed.
Taking down/out desert cooler of any make and capacity from various locations, transporting to MES Store Yard and dismantling all unserviceable parts for repair/overhauling, re-fixing the same back to its original position and making necessary connections with and including copper flexible cable 23/0.0076 Sqmm complete all as specified and directed.
M&L for painting of desert cooler’s external body, fan & pump with one coat of synthetic enameled gray paint & internal body with synthetic enameled black paint complete with brush painting after proper dusting, cleaning and scrapping old painted surfaces complete all as as specified and directed.
M&L for replacement of wood wool pad 15mm thick made out of chicken wire mesh filled with fine quality wood wool and stitched with GI wire for desert cooler of any make & size complete all as as specified and directed..
M&L for rewinding of stator of exhaust fan/kit fan 18” sweep 900 RPM of any make with super quality of winding copper wire of existing size complete with varnishing, backing, testing including painting with synthetic enameled paint of gray colour complete all as as specified and directed.
M&L for replacement of desert cooler’s cabinet locally fabricated with three side panels front, top and tank including vertical mention made out 22 SWG PGI sheet of size not more than 81.5 x 80.5 x 97.5 Cm or as per sample with double diversion grills and grill box suitable for 18” sweep fan and making holes with fixing arrangement incl 4 way PVC distributor, PVC pipe 3 to 4 Mtr for spray water, wood wool pads, electrical wiring for fan & pump controlled separately with 5 amp Piano type switch and indicator etc complete all as as specified and directed.
Servicing by means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for 63 KVA DG Set (Make : Kirloskar) Engine No.4H3445/120542, Machine No.JC/WC/6205/SIL/867K, Alternator No. ES3AO13B165088 at Pump House No. 4 at RTS & Depot Saharanpur including testing and commissioning. Note : (a) Spare parts shall be measured and paid separately under mentioned item of Sch 'A'.
Supply of lubricating Oil filter element with seal
Supply of Fuel filter element with seal
Supply of Air filter element
Supply of 'V' belt make Funnder/good year (4PK-1158 EPDM Poly 'V' Belt)
Supply of Hose pipe, including nut, bolts and clamps
Supply of Oil bypass filter element with seal
Supply of lubricating oil, grade 15W40 (K-oil premium)
Supply of inhibitor non corrosive coolant including mixed with distilled water as recommended ratio Make : Cummins
Servicing by means taking out old unserviceable engine oil from oil sump by openeing the drain plug and well cleaning the oil sump, taking out oil filter,bypass filter and diesel filter (primary and secondary) and replacement the same with new as follows for 30 KVA DG Set (Make :Kirloskar) Engine No.3H3025/1320572, Machine No. JKWL/30/SIL/8363K, Alternator No. 653C013B2506H at Pump House No.2 and at Cl-I hospitalat RTS & Depot Saharanpur including testing and commissioning. Note : Spare parts shall be measured and paid separately under mentioned item of Sch 'A'.
Supply of lubricating Oil filter element with seal
Supply of Fuel filter element with seal
Supply of Air filter element
Supply of poly 'V' belt make Funnder/good year for 3H3025 Model, part No 4H 1493.01.0.00 in user manual of Kirloskar
Supply of 'V' belt make Funner/good year A-55
Supply of Hose pipe, including nut, bolts and clamps
Supply of Oil bypass filter element with seal
Supply of lubricating oil,cgrade 15W40 (K-oil premium)
Supply of inhibitor non corrosive coolant including mixed with distilled water as recommended ratio Make : Cummins
Taking down self starter assembly from (20 KVA DG Set) its position and repairing the same by replacement of carbon brush pinion etc reassembling of all parts refixing in position testing, commissioning complete.
Taking down dynamo 12 volt from the existing position, dismantling the same and repairing by turning of commutator replacing the armature, carbon brush varnishing the coil reassembling the parts and refixing in position testing and commissioning complete all as specified and directed.
M&L for repairs of battery charging unit including replacement of non functional step down transformer, its electrical connections, relays, terminal connections etc all as specified and directed by Engr-in-charge including one coat of synthetic enamel spray paint colour as approved by EIC, after cleaning dust dirt, oil and grease etc (Painting shall be carried out at site)
Supply in replacement 12 volts 150 AH Lead Acid type battery for DG Set. Make : Amron/ Exide/ Luminous.
S&F in repair brass battery terminal heavy duty complete suitable for 12 volts Battery.
S&F PVC insulated multistranded copper wire lead for connecting battery of size 25 Sqmm complete all as directed
Supply only distilled water for batteries complete all as specified and as directed.
M&L for laying GI tubing light grade 80 mm dia with all fittings for cable protection including GI clamps nut bolts and washer etc all as specified.
M&L cutting PCC/floor/road and taking out cable and making good with PCC including material as per existing after laying of pipe for cable protection complete all as specified and directed at site of trench not more than 0.30 x 0.30m, complete all as specified and directed.
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for ducting and for finding of the cable fault in LT underground cable and returning filling (including reusing old bricks and sand) the same after rectification of the cable fault in any type of soil complete all as specified and directed
Supplying, Laying, Jointing, testing and commissioning cable XLPE insulated armoured LT 1100 grade heavy duty with Stranded aluminum conductor through pipes in ducts, poles/ trenches including fixing of copper lugs, making good to disturbed surface etc for the following cross sectional area, complete the following as specified and directed :- (Note : Excavation and earth work to be measured and paid separately)
95 Sqmm 3.5 core
35 Sqmm 4 core
Taking down defective 25/36/40/45/60/250 Watt LED light fitting/ SV/MH fittings, street light fitting mounted on pole/bldg on bracket disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and including trimming of branch if obstacle for lights to illuminate the area and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge. (Note- If any street light/ Flood light found US the same has been replaced by contractor and measure the same under supply only item of respective Schedule.)
Taking down defective 90/120 Watt led fitting mounted on 11 mtr long Semi high mast consisting of LED flood light fittings (Approx 4 to 6 Nos), street light fitting, mounted on 11/13mtr long high mast pole on bracket/ round ring, disconnecting, testing all components, dismantling of defective components such as driver of LEDs and cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge at site. (Note- If any street light/ Flood light found US the same has been replaced by contractor and measure the same under supply only item of respective Schedule.)
Taking down defective 250/400 Watt LED light fitting/SV/MH light fittings, High mast light fitting through motorised /manual system, mounted on 21 mtr long high mast pole on bracket/ round ring, disconnecting, testing all components, dismantling of defective components such as choke, igniters, holders, capacitors, and providing new PVC cable for wiring lamps, including cleaning of cover, connection with supply and testing the street light fitting after fixing new components and then mounting to its original position and making the fitting functional all as specified and directed by Engineer in Charge at site. (Note - If any street light/ Flood light found US the same has been replaced by contractor and measure the same under supply only item of respective Schedule.)
Supply only LED flood light 120 Watt 230 Volt AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Make :Havells, CG, Phillips
Supply only LED flood light 210 Watt 230 Volt AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Make :Havells, CG, Phillips
Supply only LED street light 90 Watt 230 Volt AC out door type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Make :Havells, CG, Phillips
Supply LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply LED street light fitting 45 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.
Supply and fixing LED Solar street light fitting 12 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete. (Excavation & earth work shall be measured separately)
S&F in replacement of Gate lights/post top light with 20 Watt LED light as light source, IP-65, made of spun aluminium landscape luminaire suitable for fixing on 40/50 mm GI pipe on the gate post including connection with all necessary accesssories complete all as specified and directed by Engr-In-Charge. Make : Havells / Phillips/cropmpton/C&S/Bajaj
M&L for bracket made of GI light grade pipe 1.2 Mtr long of size 40 mm bore bend to shape as per site requirement fixed to pole with 40 x 5 MM -02 Nos, size clamps bolts, Nuts, washers including painting two coats of aluminium paint over a coat of primer all as specified and directed.
Supply and fix in replacement of GI tubing medium grade 40 mm dia ring with cap of pole including welding of flat iron 40mm x 5mm thick - 04 Nos including holes for suitable fixing of flood lights and painted with one coat of red oxide and two coats of synthetic enamel paint with clamps, bolts, nuts and whashers for fixing on poles, complete all as specified and directed.
Supply and erection of steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified of type 410 SP-31, 9 Meter long, including marking alternate yellow and black strips 30 cm height- total - 5 Nos with two coats of aluminium paint over a coat of zinc chrome primer above embedded portion at GL, complete all as specified and directed. (Note - Earth work and PCC for foundation channels, clamps, nuts and bolts to be measured and paid for separately).
M&L for plain cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundation of stay assembly etc including necessary form work, complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for coping around poles, including necessary form work finishing even and smooth without using extra cement, complete all as specified and directed.
M&L for plain cement concrete 1:4:8 concrete D-2 using 40mm graded stone aggregate in foundation filling and mass concrete, for bedding of pole, complete all as specified and directed.
M & L in replacement DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 10/16 Sqmm 2/4 core and fixed to the PSC/Steel Poles by means of suitable size of clamps with nut ,bolts and including provn for fixing 01 no of single pole MCBs 6-32 amps,10KA and MCB TPN 6-32 amps, 10 KA, ‘B’ series = 01 No inside the box complete all as specified and directed. Make :- Sintex/Hensel/standard or equivalent.
S&F in repair Astronomical + Digital Time switch model Havells : HSN code : 9107, Cat Part No.DHTQB01016 or equivalent in Phillips/CG/L&T
S&F in repair nature time switch single phase model swadeep -02 sensor only along with switching timer complete all as specified and directed by Engineer-in-Charge.
S&F in repair Street light timer panel, single phase with maximum load of 12 Kw with inbuilt astronomical time switch, 65 Amp contactor, 63 Amp SPN confirming to IS/IEC/604947-4-1, FRLS internal wiring, with IP 54 protection and inbuilt short circuit protection. All as specified and directed at site. Make : Havells, HSN Code 8537, Cat Part No IHXSS0312A or equivalent in CG, C&S, Phillips
S&F in repair contactor 65 to 110 Amp 3 Phase , 415 V , as per IS 13947-4-1 ,suitable for nature time switch model swadeep - 02 complete all as specified and directed by Engineer-in-Charge. Make :- Havells, Type : CN565T11*, Cat No. IHPAA065511* or equivalent BCH, L&T, CG , Siemens.
S&F in repair contactor 32 Amp 3 phase, 415 volts as per IS 13947-4-1 ,suitable for nature time switch model swadeep -02 complete all as specified and directed by Engineer-in-Charge. Make :- BCH or equivalent in L&T, CG , Siemens.
S&F in repair LED driver 75/90 watt, single Phase , 240 V , for LED street light fitting complete all as specified and directed by Engineer-in-Charge. Make : Crompton, Havells, Phillips
S&F in repair LED driver 60 watt, single Phase , 240 V , for LED street light fitting complete all as specified and directed by Engineer-in-Charge. Make : Crompton, Havells, Phillips
S&F in repair LED driver 35/45 watt, single Phase , 240 V , for LED street light fitting complete all as specified and directed by Engineer-in-Charge. Make : Crompton, Havells, Phillips
S&F in repair surge protection device compatible with outdoor LED fixture, make : Crompton, Cat part No.SRPS-HP-5K-440 or equivalent in C&S, Havells, Phillipsfor LED light fitting with rated power up to 75W complete all as specified
Labour only for stringing, tightening, fixing and connecting ACSR conductor and GI Wire of existing LT overhead line any size any type, between pole to pole, approximate span length 40 to 50m, complete the following all as specified and directed : -
2 Wire with/Without GI Wire.
5 Wire With GI Wire.
6 Wire With GI Wire.
M&L in repair for LT line PVC Spacers spiral type for the following :-
Spacer for two wire
Spacer for three wire
Spacer for four wire
Dismentling of ACSR conductor, service feeder or distribution spans complete all as directed.
Supplying, Stringing, Tightening, Fixing & connecting ACSR conductor of any size for over Head LT/HT Line including aluminium binding wire or aluminium tape of suitable type clamps/connector or other jointing material complete all as specified and directed.
M&L for cross arms, bracing supports clamps and back plate fabricated from structural steel section including bolts, nuts, washers and welding, bending, cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint all as specified and directed by EIC.
M&L for stringing in replacement of steel wire 4 mm dia 8 SwG as continuous earth wire and grading incl cradal hexagonal binding properly with channel/Angles etc complete all as specified
S&F anti climbing devices. Comprising of 2.24mm dia galvanised steel 2 stranded barbed wire with 2.0 mm dia barbs wrapped spirally round poles to a length of 0.5 to 1.0 mtr clamped and properly screwed all as directed by Engr-in-Charge
Supply and fixing in repairs stay assembly for HT/LT Pole comprising of 7/3.15mm galvanized steel stranded stay wire of required length fixed to pole with and including clamps fabricated out of MS Clamps 50 x 6 mm flat iron including nuts, bolts and washers, MS galvanized stay bow 14mm dia 400mm long galvanized steel stay rod 16mm dia, 1800mm long with ratchet type nuts & bolts and stay plate, galvanized thimble 02 Nos, loop insulators 65mm x90mm clearance dia of hole 16mm all as specified and shown in electrical plate No. 1 of MES SSR including all necessary excavation and earth work, PCC (1:3:6) type C-2 using 40mm graded stone aggregate ,embedded block and disposal of surplus soil to a distance not exceeding 50mtr complete all as specified and directed by EIC.
Repairs to existing stay assembly including tightening of stay wire, shifting of clamps fixed to pole or by repairing to PCC coping by breaking and making new coping with PCC 1:2:4 type B-1 using 20 mm graded stone aggregate complete all as specified and directed at site .
M&L for MCB single SPN, 32 Amp 240 volt C curve 10 KA, IP 20 suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed
M&L for MCB single SPN, 40 Amp 240 volt C curve 10 KA, IP 20 suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed
M&L for MCB single TPN, 63 Amp 415 volt C curve 10 KA, IP 20 suitable for cable up to 35 Sqmm cross sectional area complete including suitable size copper Lugs complete all as specified and directed
M&L for repairing LT feeder box/ panel and their doors, inner compartments etc by denting/ welding where required and Cleaning, removing old paint by paint remover/scrappers for any number of coats, any width or girth and applying two coats of synthetic enamel paint by spray painting,inside and outside of panels(second coat shall be applied at the interval of one day) of the approved colour, complete all as specified and directed.
M&L for pin insulator porcelain type vitreous white brown including one galvanized mild steel spindle two galvanize iron washers and one galvanized iron nut 100 mm height, 65mm dia for 1100 V grade, complete all as specified and directed.
M&L for shackle type porcelain vitreous white, brown including one galvanized mild steel straps, washers, bolts and nuts 100 mm height, 115 mm dia, section of strap 31 x 5 mm for 1100 V grade, complete all as specified and directed.
Supply only Insulator pin type porcelain vitreous, white brown or green 150mm height and 150mm dia including one galvanized mild steel spindle, two galvanized washers and one galvanized iron nut for conductor working pressure 11000 volt grade, complete all as specified and directed.
Supply only Insulator disc type porcelain vitreous, white, brown or green 145 mm height and 255 mm dia ball and socket type single disk assembly for tension with tension clamp for conductor working pressure 11000 volt grade, complete all as specified and directed.
M&L in repair of Air termination single poined aluminium rod 12mm dia and 300 mm long complete all as specified and as directed
M&L in repair of test terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm incl 3 nos, 8 mm ida 25mm long hex. Head screw complete all as specified and as directed
S&F in repair of Earth continuity conductor aluminium strip 25 x 3mm with saddles and fixing screws etc in wall all complete as specified and directed
S&F in repair of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI strip 32x6 mm
M&L for Painting of single LT steel tubular pole including. cleaning and scrapping the old surface and then applying two coat of aluminium synthetic enamel paint over a coat of red oxide primer on all steel structure mounted on pole viz. Cross Arms , Clamps, bolts, nuts, brackets etc. and including painting of pole/ structure ith two coat of synthetic black & yellow enamel paint strip 300 mm wide alternative from bottom to upward of LT pole up to height of 1.5 mtr above the embedded portion of GL and writing pole number balance portion of pole shall be painted with two coats of Aluminium enamel paint over a coat of red oxide primer, complete the following as specified and directed :- Notes: - (i) Pole will be cleaned with steel brush to remove old unserviceable paint or scrapped complete surface. (ii) All poles will be numbered all as directed at site. (iii) If painting of poles not properly and not satisfied by JE/Engr-in-charge shall not be paid to contractor or otherwise repaint without extra cost.
M&L for preparing old metal/wooden surface by cleaning, removing old paint by paint remover/scrappers for any width or girth and applying two coats of synthetic enamel paint by spray painting (second coat shall be applied at the interval of one day) of colour complete all as directed and specified by EIC for the following items :- .
150 mm CI/GI Pipe line
Gate valves and gate valve chamber (metal) doors
Shutters for sub stations and pump houses
Vertical Turbine Pumps (external body)
Doors incluindg glazed door frames
Windows
M & L for cutting of tree branches of any sizes and dia, not less than 2 Mtr around the LT /HT OH line which obstructing the power supply/ maintenance of electric supply as well as illumination in area including repair of damage broken ACSR conductor, GI wire and jumpers and disposed exc 50 mtr away clearing area and testing of line, complete all as specified and directed. Note : (i) Span length is aproximate 40 to 50m.
Supply and labour for spreading stone aggregate of size 40mm at 11 KV sub station/Transformer/panel board/two pole/four pole structure area, complete all as specified and directed.
Supply only PVC insulated multistrand Copper Cable 3 core size 1.5 sq mm for bldg/security light fittings connections.
Supply only PVC insulated multistrand Copper Cable 3 core size 2.5 sq mm for bldg/security light fittings connections.
Supply only class 2 electrical hand gloves HT 11 KV complete conforming to IS :4770/1991, all as specified and as directed
Supply only for Filling/top up of insulation oil confirming IS-335, complete all as specified and directed. Make :- Power oil/Savita/ Castrol
Supply only Insulation electric tape roll 20 mm 25 mtr long complete.
Electric shock treatment chart as per sample of size 750x480mm
S&F pad locks mild steel with 5 levers for rolling shutter complete all as specified and directed
Disconnecting carefully old unserviceable Ammeter from panel board and Supply & Fix of new 96 mm size square digital type ammeter of range 0-100 Ampere with set of CTs of suitable rating complete all as specified and directed. Make : L&T cat pt no WL131010OOOO or Equivalent in AE/Schiender.
Disconnecting carefully old unserviceable Voltmeter from panel board and Supply & Fix of new 96 mm size square digital type Voltmeter of range 0-500 Volt complete all as specified and directed Make : L&T cat pt no WL132010OOOO or Equivalent in AE/Schiender.
Supply & Fix in replacement of LED type RYB indicating lamps on existing panel board including necessary fixing and connecting arrangement complete all as specified and directed
Supply and fix vertical type air break gang operated triple pole, mechanically operated, outdoor type with all fittings, accessories, mounted on and including HT 11 KV porcelain insulators and steel channel frame GI Operating rod 25 mm dia of suitable length worked from ground including locking arrangements, with 7 livers Naval brass lock, suitable for 200 Amps current rating complete. (set of three)
M&L for High tension/Low tension cable fault checking by high tension cable fault testing machine
S&F cable jointing kit 11 KV (earthed) grade cable for straight through termination (Heat shrinkable) type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm complete all as specified and directed.
S&F cable jointing kit 11 KV (earthed) grade cable for end termination (Heat shrinkable) type joint complete with jointing material and all accessories for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm complete all as specified and directed.
M/s badrinath Traders (BID ID -3117266)
PARADISE INFRA POWER COMPANY (BID ID -3119527)
SHRI RAM ENTERPRISES (BID ID -3114398)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .