Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical 12 GHAR PARIHAR BBHAWAN BASTEPUR NEAR BY MOTHER TEERESA SCHOOL RAEBARELI UTTAR PRADESH 229001 | RAE BARELI | UTTAR PRADESH | 229001 | Rejected-Technical Responsive but single bid |
| 2 | Rejected-Technical | Rejected-Technical Non Responsive |
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
23 Mar 2026, 6:30 pmClosed
EE RMC
RMC
Repairing of Madhukam Sabji Mandi under Ward No-28
2026_UDD_111778_1
239/eng 2026
Open Tender
Civil Works
Works
180 days
AS PER NIT
Please refer Tender documents.
2 documents required · 2 mandatory
₹11,800
₹3.9 L
16 Apr 2026
18 Mar 2026
24 Mar 2026
18 Mar 2026
23 Mar 2026
18 Mar 2026
Labour for cleaning the work site before and after work etc.
Dismantling pucca brick work including stacking serviceable materialsin countable stacks within 15m lead and disposal of unserviceable materials with all lead, all complete as per direction of E/I.
Dismentalling old plaster and pointing in Cement or lime and ranking out of joints…..........................Do…............................E/I.
EARTH WORK IN EXCAVATION IN FOUNDATION Trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 M including all lift, leveling ramming the foundation trenches, removing roots of tree shrubs all complete as per approved design, building specification and direction of E/I.
FILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume)
Providing coarse clean local SAND IN FILLING in foundation trenches or in plinth including ramming and watering in layer not exceeding 150 mm thick with all leads and 1.5 M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume)
Providing designation 75-B, BRICK FLAT SOLING joints filled with local sand including cost of watering,taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing and laying in position specified grade of reinforced cement concrete ,excluding the cost of centering ,shuttering, finishing and reinforcement - All work up plinth level.
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing designation 75 B BRICK WORK in CM. (1:6) in SUPERSTRUCTURE with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening,racking out joints to 15 mm depth,curing, taxes and royalty all complete as per building specification and direction of Engineer Incharge
Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5 including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all complete as per building specification and direction of E/I
Centering and shuttering including struting, propping etc. and removal of form for -
Beams, plinth beams,-
Providing tor steel reinforcement TMT FE 500 of following dia. rods as per approved design and drawing including carriage of bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust placing the rods in position all complete as per building specification and direction and direction of E/I. (ONLY VALID FOR SAIL & TATA STEEL, JSPL, ELECTRO STEEL LTD. AND VIZAG STEEL) TOR 8 MMDIA. @ 30% of total steel qty.
TOR 10 MMDIA. @ 40% of total steel qty.
TOR 12 -32 MM DIA. @ 30% of total steel qty.
Providing and laying 25mm thick Kotah stone slab flooring of approved size texture and colour over 19mm thick base of lime motar(1:1:1)( limeputty:surkhi:coarse sand)laid over and jointed with grey Cement slurry mixied with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved qualityof carborandum stone including cost of curing taxes and royalty all complete as per building specifications and direction of E/I. (iv) 600x600 mm
Supplying, fitting & fixing local made fully glazed Steel Windows or Ventilators in toilets of standard rolled 'z' & mullion steel sections & size as per IS-1038 joints met & welded with 100x16x3mm.M.S. lug fixed in cement concrete (1:2:4) blocks, 15x10x10cm size including cost of oxdised iron fittings with hinges,handle per steps catch springs, 3mm thick plain glass panes with aluminium beads & inner frame fixed with lungs with 20mm long 6.3mm. G.I. counter sunk machine screw & nuts & applying a coat of red lead paint carriage to work sote hoisting & placing in position in all storys & taxes all complete as per building specification & direction of E/I.
Supplying, fitting & fixing M.S. GRILL made of 20 x 6 mm flat as per approved design and drawing properly fabricated with joints continuous fitted, welded and finished smooth, hoisting as per building specification and direction of E/I.
Providing two coats of oil bound distemper ofapproved shade and make over a coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall suface to prepare the surface even amd smooth complete.
Providing Primer one coat of read lead paint of approved make over new STEEL SURFACE preparing the surface after cleaning, removing rust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing 2 coats of SYNTHETIC ENAMEL PAINT of approved shade and make over STEEL SURFACE grills & railings including cleaning the surface thoroughly scaffolding and taxes all complete as per building specification and direction of E/I.
13.99 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.99.1 One or more coats on old work
Stone crusher dust finer than 3mm with not more than 10% passing 0.075 sieve at Quary
Providing and laying factory made chamfered ledge Cement Concrete paver blocks (size 60mm) in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & sizel shape, made by table vibratory method using PU mould, laid pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in- Charge. 16.91.1 60mm thick C.C. paver block of M-35 grade with approved colour, design & pattern.
Providing and laying in position concrete of M15 grade excluding the cost of centering and shuttering- All work upto plinth level : 1:2:4 (1 cemet : 2 coarse sand (zone-iii) : 4 graded stone aggregate 20mm nominal size )
A) LOCAL SAND
B) COARSE SAND
C) STONE CHIPS
D) BRICKS
E) Earth
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 SQMm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit with modular switch modular plate suitable Gl box etc as required.
Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC condult alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit as required 2x1.5 sq mm + 1x1.5 sq mm earth wire
2x2.5 sq mm + 1x2.5 sq mm earth wire
Supplying and foxing of following sizes of PVC conduit along with the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25mm dia
32mm dia
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc as required. 5/6 amps one way switch
15/16 amp one way switch
5/6 amp 3 pin socket outlet
5/16 amp 6 pin socket outlet
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc as required. 4/5 Module (78mm x140mm x 50mm)
8/9 Module (78mmX230mmx60mm)
Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required.
Installation testing and commissioning of pre wired fluorescent fitting / Compact fluorescent fitting off all type complete with all accessories and tube etc directly / wall including connection with 1.5 SQMm FR PVC insulatted copper conductor single core cable and earthing etc. as required.
Installation testing and commissioning of ceiling fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing following ways horizontal type three pole and neutral sheet steel MCB distribution board 415 volts on surface/recess complete with tinned copper bus bar neutral bus bar earth bar din bar interconnections powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 Way (4+18) Double Door Horizontal Type
Supplying and fixing 6 Amp to 32 Amp rating 240 volts 10 KA "C" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections testing and commissioning etc. as required. 6/32 Amp Single Pole
6/32 Amp TPN
40 Amp TPN
Supplying and fixing of following rating double pole (Single pole & neutral) 240 volts resudual current circuit breaker (RCCB) having a sensivity current 30 miliampere in the existing MCB DB complete with connections testing & commissioning etc as required. 63 Amps
Providing and foxing M.V. danger Notice plate of 200mm x 150 mm of made of mild steel at least 2 mm thick and vitreous enamelded white on both side and with inscription in single red colour in front side as requird
S.I.T.C of following rating surface mounted LED Tube Lighting Fitting Suitable for 230V 50 Hz Single Phase Supply etc. complete as required. 20/22 W LED Tube Light
Supply Installation Testing & Commissioning of following sizes ceiling fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard (up to 30cm) with 1.5 SQMm FR PVC insulated copper wire suitable for 230V 50 Hz Single phase supply etc. complete as required. Make- Usha/Crompton/Havells 1200 mm (48) BLDC 5 Star rating 32W Ceiling Fan
Good & Service Tax (GST)
Labour Cess
stage.html
html • 0.02 MB
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
Tendernotice_2.pdf
PDF • 1.73 MB
BOQ_150922.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .