Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC VILL NIMOO LEH LADAKH 194101 | NIMOO | LEH | LADAKH | 194101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹42.5 L+₹34,331.63 (0.81%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹42.9 L+₹73,610.65 (1.74%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹44.5 L+₹2.3 L (5.36%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹44.9 L+₹2.7 L (6.48%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹35.3 L
EMD Value
₹70,500
Closing Date
15 Oct 2019, 6:00 pmClosed
CWE KHUMBATHANG
HQ CWE KHUMBATHANG, KARGIL 194103
CWE/K-T21/2019-20 Special repair of Bldg no. T-42 T-44 T-53 and T-54 of certain Bde at Nimu under AGE(I) Nimu
2019_MES_284881_1
CWE/K-T21/2019-20
Open Tender
Civil Works
Item Rate
180 days
NIMU
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE(I) NIMU
₹70,500
Yes
3 Apr 2020
24 Sept 2019
16 Oct 2019
24 Sept 2019
15 Oct 2019
8 Oct 2019
24 Sept 2019 - 6 Oct 2019
Amount
Excavation over areas not exceeding 1.5 m deep and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge. .
Excavation over areas exceeding 1.5 mtr & not exceeding 3.0 mtr deep and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge. .
Excavation over areas exceeding 3.0 mtr & not exceeding 4.5 mtr deep and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge. .
Excavation in trenches not exceeding 1.5 mtr wide & not exceeding 1.5 mtr in depth as in foundation, drains, laying/taking out pipes or cables etc, or for shaft, well, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge. .
Returning, filling in including spreding, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge.
Demolition of plain cement concrete (un-reinforced) in ground floors and pavings not exceeding 15 cm thick (below or above ground level), complete all as specified and directed by Engineer-in-Charge.
Demolition of plain cement concrete (un-reinforced) of any description and in any position not specifically provided for, complete all as specified and directed by Engineer-in-Charge.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises, complete all as specified and directed by Engineer-in-Charge.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards / slabs / blankets, any thickness, including cover fillets, complete all as specified & directed by Engineer-in-Charge.
Dismantling of timber scantling as in fillet, rails, posts, rafters, purlins etc. under 40 sqcm in section in any position as in unframed work complete all as specified & directed by Engineer-in-Charge.
Dismantling of timber scantling over 40 sqcm in section in any position as in framed work complete all as specified & directed by Engineer-in-Charge.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed by Engineer-in-Charge.
Taking down chowkats or frames with shutters (without taking of shutter from the frame) exceeding 1.5 sqm but not exceeding 4.0 sqm each including making good the disturbed portion of wall etc. complete all as specified and directed by Engineer-in-Charge. Note: Any cutting and pinning, making good to walls & finishings shall deemed to be included in quoted rates.
Description all as per BOQ item No. 15.00 here-in-above but chowkats or frames not exceeding 1.5 sqm complete all as specified and directed by Engineer-in-Charge.
M & L for Plain Cement concrete, 1:4:8, type D-2, (using 40 mm graded mechanically crushed stone aggregates) as in foundations, fillings and mass concrete, etc. complete all as specified and directed by Engineer-in-Charge.
M & L for Plain cement concrete (Cast-in-situ) 1:2:4, type B-1, (using 20 mm graded mechanically crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge. Note: Any formwork required in this work shall deemed to be included in quoted rates.
M&L for Precast cement concrete, 1:2:4 (type B-1) (using 20mm graded mechanically crushed stone aggregate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge. Note: Any formwork required in this work shall deemed to be included in quoted rates.
M&L Precast cement concrete, 1:3:6 (type C-1) (using 20mm graded mechanically crushed stone aggregate) block mansonry with solid blocks, exceeding 10cm width and set in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete, 1:2:4, type B-1, (Nominal mix) (using 20mm graded mechanically crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed by Engineer-in-Charge. Note: Formwork & reinforcement shall be measured and paid separately.
M&L for Walling of random rubble stone masonry, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M&L for Walling of random rubble stone masonry, uncoursed, well bonded, laid dry in retaining walls, abutments and similar work complete all as specified and directed by Engineer-in-Charge.
Use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished flat surfaces of concrete etc complete all as specified and directed by Engineer-in-Charge.
S&F 25mm dia MS drapery rod, teak wood finish, good quality, including wooden finish PVC brackets for holding of curtain rod and end knobs of matching colour complete all as specified and directed by Engineer-in-Charge. Note: A set of 2 Nos bracket and 2 Nos Knob shall be provided at every 1.5 to 2.0 mtr length(on average basis) of drapery rod as directed by Engineer-in-Charge.
S&F galvanised mild steel wire cloth, 0.63 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staples, complete all as specified and directed by Engineer-in-Charge.
S&F aluminium (extruded section) body, door closer, hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and directed by Engineer-in-Charge.
S&F floor door stopper of brass body and tongue, anodised, with hard drawn steel spring, overall length of cover plate 150mm, fixed in floor complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed by Engineer-in-Charge.
S&F mild steel work as in half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium, powder coated (Minimum thickness of powder coating 50 micron) door shutters, aluminium section weighing not less than 0.55 kg/mtr including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed by Engineer-in-Charge.
S&F Powder coated, anodised aluminium frame, (Minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates, jointing cleat for fixing etc, aluminium section weighing not less than 0.55 kg/m complete all as specified and directed by Engineer-in-Charge.
S&F Anodised aluminium, Powder coated (Minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bars, aluminium sections weighing not less than 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm long (2 Nos.), suitable handle (1 No.) complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed by Engineer-in-Charge.
M&L for 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work as in wall, complete all as specified and directed by Engineer-in-Charge.
Description all as per BOQ item No. 36.00 here-in-above but as in ceiling
M&L for 9 mm thick prelaminated particle board, interior grade, prelaminated both side with decorative choice lamination fixed with screws to metal frame work as in wall, complete all as specified and directed by Engineer-in-Charge.
M&L for 2nd class soft wood, plain fillets, square, rectangular or triangular in section of area exceeding 13 sqcm but not exceeding 25 sqcm, clean sawn, secured with nails or brads, complete all as specified and directed by Engineer-in-Charge.
M&L for 2nd class soft wood beading, in section of area exceeding 3 sqcm but not exceeding 6 sqcm, bull-nosed, splayed, chamfered or rounded on one edge or face, complete all as specified and directed by Engineer-in-Charge.
M&L for 25mm thick, Plain cement concrete, 1:2:4, type B-0 (using 12.5mm graded mechaniacally crushed stone aggregates) as in subbase to receive the floor finish, complete all as specified and directed by Engineer-in-Charge.
M & L for 75mm thick, Plain cement concrete, type C-2, 1:3:6 (using 40 mm graded mechanically crushed stone aggregate) as in plinth protection, finished the surface even and smooth without using extra cement including making expansion joints filled with bitumen mastic filling consisting of 85/25 bitumen and sand in the ratio of 1:1 complete all as specified and directed by Engineer-in-Charge.
M & L non-skid coloured ceramic tiles, 7 mm to 8 mm thick (Square / rectangular), area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors etc., set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tile, over & including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L non-skid coloured ceramic tiles, 7 mm to 8 mm thick (Square / rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc., set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tile, over & including 15 mm thick screed bed or bedding layer in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L for glazed ceramic coloured tiles of size 350mm x 250mm x 7mm / 450mm x 350mm x 7mm thick as on vertical surfaces such as wall, skirting, dado etc, set and jointed in neat cement slurry and pointed in white cement with pigment or coloured cement to match the shade of tile over & including 10 mm thick rendering/backing coat plaster in cement mortar 1:3, complete all as specified and directed by Engineer-in-Charge.
M&L 15 mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L 10 mm thick rendering in cement mortar 1:6 on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L 12mm thick rendering in cement mortar 1:4 on fair face of brick work or concrete surfaces as in wall, finished even and smooth without using extra cement and mixed with water proofing compound as per manufacturer's instruction, complete all as specified and directed by Engineer-in-Charge. Note:- The water proofing compound shall measured & paid seperately.
Supply only Liquid water proofing compound ISI marked complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered/concrete surfaces and applying three coats of white wash as in wall, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered/concrete surfaces and applying two coats of cement base paint over & including a coat of alkali resistant primer as in wall, complete all as specified and directed by Engineer-in-Charge.
S&F 4.8mm thick plain sheet glass, ordinary quality and glazing with oil putty or wooden beads in square exceeding 0.5 Sqm in each pane, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted steel surfaces of any description over 10 cm width or girth, not otherwise described and applying one coats synthetic enamel paint complete all as specified and directed by Engineer-in-Charge.
Taking up or down 15 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer-in-Charge.
Description all as per BOQ item No. 54.00 here-in-before but 20 mm bore.
M & L for 16 mm outer diameter (wall thickness of pipes shall be as per IS 15801), 3-layer PP-R (Polypropylene random copolymer) pipes SDR 7.4 & concealed pipes SDR 7.4 (PN 16) UV stablised and anti-microbial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc. complete all as specified and directed by Engineer-in-Charge.
Description all as per BOQ item No. 56.00 here-in-before but 20 mm outer diameter.
S&F in repair 15mm bore stop valves, chromium plated, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions, complete all as specified and directed by Engineer-in-Charge.
S&F in repairs hand shower (health faucet ) with 8mm dia and 1 meter long CP flexible tube and wall hook complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC valveless, syphonic action type, flushing cistern of capacity 10 litre, low level, white, with inlet, ball valve, float and handle including brackets and including 32mm dia PVC flush pipe of required length and making connection including bracket, complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous china wash down water closet pan "Pedestal pattern", white, with plastic water closet seat, white, closed pattern with flat bottom & cover and mild steel chromium plated or aluminized hinging device (excluding flushing cistern) including flush pipe and joint etc. and connection to drain, flushing pipe , anti-syphonage pipe and fixing arragngements with fixing bolts etc. including making good the disturbed portion of floor in cement concrete 1:2:4 type B-0 complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous china wash basin, white/colour, flat back of size 550mm x 400mm excluding taps, waste, chain and plug and porcelain stopper but including brackets & 32 mm bore waste coupling of brass, chromium plated complete and including cutting for and pinning in ends of brackets or erecting stand exclusive of waste/supply pipe complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore pillar tap, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed by Engineer-in-Charge.
S&F in repair 15mm bore bib taps, chromium plated, fancy type, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed, complete all as specified and directed by Engineer-in-Charge.
S&F PVC connections 15mm size with PTMT nuts of length 450 mm, complete all as specified and directed by Engineer-in-Charge.
S&F in repair tubular towel rail, 20mm dia, D type, 600mm long between flanges, brass, chromium plated including brackets fixed to wall complete all as specified and directed by Engineer-in-Charge.
S&F in repair Vitreous china white soap dish/tray (approx 160mm x 160mm x 90mm) embedded in the wall complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 500 litre capacity rotational moulded HDPE water storage tank (Cylindrical vertical closed top), double layer, hoisted and fixed in position or placed in position inside or outside the building, connecting up pipes and securing access covers complete all as specified and directed by Engineer-in-Charge.
S & F 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete as directed by Engineer-in-Charge.
S & F 75mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete as directed by Engineer-in-Charge.
S & F 75 mm bore PVC (SWR) vent cowl complete all as specified and directed by Engineer-in-Charge
M & L concrete bed to drain pipe in PCC (1:4:8) type D-2 (using 40mm graded mechanically crushed stone aggregate) including packing under and haunching against the sides of pipe after laid and tested for 100 mm bore, complete all as specified and directed by Engineer-in-Charge
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, etc. with MS conduit / teak wood batten / PVC conduit or casing capping and removing the materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring ( as per IS colour coding) with multi-stranded copper conductor FRLS, PVC insulated, unsheated 1.5 sqmm (nominal area) cable, 1100 volt grade drawn through & including medium duty PVC casing-capping (size not less than 25mm x 16mm) (ISI marked) on wall with all fittings / accessories & fixed with GI saddle, GI screws, rawl plugs etc. and including 1.5 sqmm (nominal area) FRLS PVC insulated copper earth wire connected to common earth dolly including sunk cast iron/pressed steel terminal boxes of suitable size for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover for one light point/fan point/bell point controlled by one switch, complete all as specified and directed by Engineer-in-Charge.
Description all as per BOQ item No. 75.00 here-in-before but for one 3 pin socket outlet, 5 Amps on same board with other switch complete all as specified and directed by Engineer-in-Charge.
Description all as per BOQ item No. 75.00 here-in-before but for one 3 pin socket outlet, 5 Amps on independent board complete all as specified and directed by Engineer-in-Charge.
Description all as per BOQ item no 75.00 here-in-before but for power point with 2.5 sqmm (nominal area) FRLS PVC insulated unsheathed copper cable on independent board complete all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush type, single pole, one way, 15 Amps, complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, 2 in 1, three pin, 5 & 15 Amp, flush type universal complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, 2 in 1, three pin 5 Amp, flush type complete all as specified and directed by Engineer-in-Charge.
S&F in replacement distribution board, double door, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, single pole and neutral, 8 way with 200 Amps rated copper bus bar, neutral link, earth bar, din rail, IP43 protection, , 240 volts, flush to wall / fixed on surface, complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, single pole & neutral, 32 Amp, 240 volt, rupturing capacity not less than 10 KA, 'C' curve, IP 20 complete all as specified and directed by Engineer-in-Charge.
S&F in repair MCB, single pole, 6 to 32 Amp, 240 volt, rupturing capacity not less than 10 KA, 'C' curve, IP 20 complete all as specified and directed by Engineer-in-Charge
S&F in replacement 18 watt, 6500K illumination, LED tube light fitting, wall mounted, decorative ultra slim square profile linear with extruded, polycarbonate, environmental friendly, energy efficient type, 4 feet long, channel type bracket including 18 watt LED tube rod inclusive of necessary connection prewired and making connection with 3 core PVC copper flexible cable of 1.5 sqmm size with nearest ceiling rose complete all as specified and directed by Engineer-in-Charge.
S&F in replacement wiring for circuit / submain wiring with two single core FRLS cable, PVC insulated and unsheathed cable with copper conductor (multistrand) of size 4 sqmm drawing into and including concealed medium duty PVC rigid non metallic conduit of adequate size(not less than 20mm bore) and single core FRLS cable, PVC insulated and unsheathed cable with copper conductor (multistrand) of 2.5 sqmm as earth wire complete all as specified & directed by Engineer-in-Charge. Note: 2 run of 4 sqmm wire and one run of 2.5 sqmm wire alongwith 1 run of PVC conduit shall be measured as single unit.
S&F ceiling rose, three terminals, flush type, ISI marked, PVC/polycarbonate, isolated body, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement energy saving and environmental friendly long life LED street light, 45 watt, made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection including brackets of 40mm bore GI pipe(light grade), bent to shape of suitable length as reuired at site for fixing the light fittings with necessary clamps, nuts and bolts and making necessary connections, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 2" x 2" LED light fitting 28 watt suitable for false ceiling complete all as specified and directed by Engineer-in-Charge.
M&L earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtrs deep below normal ground level) with top edge of earth plate at a depth not less than 1.50 metre below the normal ground level, connected to galvanised earth lead wire of 4.00mm dia as earth by means of nuts, bolts, washers, checknuts of iron or steel including PCC pits in cement concrete 1:2:4, type B-1 (using 20mm graded mechanically crushed stone aggregates) and RCC cover in cement concrete 1:2:4, type B-1(using 20mm graded mechanically crushed stone aggregates) and necessary earth work in any type of soil, light grade GI watering pipe 20mm bore with funnel and wire mesh and 15 mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate, complete all as specified and shown electric plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed by Engineer-in-Charge.
H R CONSTRUCTION
TSEWANG DORJAY
osho traders
M/S LOBZANG NORBOO
M/S STANZIN NOBROO
M/S LIBE & CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .