| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 LAccepted-AOC 1090 GROUND FLOOR SECTOR 18 C CHANDIGARH | ₹1.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹1.9 LRejected-Finance | ₹1.9 L | L2 | Rejected-Finance Higher rates |
| 3 | L3₹2.4 LRejected-Finance | ₹2.4 L | L3 | Rejected-Finance Higher rates |
| 4 | L4₹2.9 LRejected-Finance 697 SECTOR 43A CHANDIGARH CHANDIGARH 160043 UDYAM CH 01 0015222 04ATNPS4948P1ZP B R M | CHANDIGARH | CHANDIGARH | 160043 | ₹2.9 L | L4 | Rejected-Finance Higher rates |
| 5 | L4₹2.9 LRejected-Finance 6273 BLOCK G AEROCITY DISTT MOHALI | AEROCITY | MOHALI | ₹2.9 L | L4 | Rejected-Finance Higher rates |
Tender Value
₹2.9 L
EMD Value
₹5,818
Closing Date
26 Feb 2026, 11:00 amClosed
Er Sanjay Sahni
EEPH8 Chd
Repair and rewinding of motor alongwith various electrical itmes at fire fighting plant and AC plant in Punjab and Haryana High Court Sector 1 UT Chandigarh for smooth running of summer season
2026_CHD_90800_1
PH8/2026/2611089/19
Open Tender
Public Health Products
75 days
Chandigarh
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹5,818
23 Apr 2026
20 Feb 2026
26 Feb 2026
20 Feb 2026
26 Feb 2026
20 Feb 2026
Dressing of internal HT/LT internal/ with 1.5 control pannel wire with thimbling and PVC tie i/e cleaning of complete panel from inside with nut bolt, thimbles,tightening of bus bar, bolts, earthing wire connections and testing of pumps/motor to the entire satisfaction of EIC.
Providing and fixing of single phase preventor including making connection and testing complete in all respect complete in all respect to the entire satisfaction of EIC Make: Minilec
Providing and fixing of Indicator lamp as per site requirement complete in all resepct Make L&T
Providing and fixing of 3 pole MCCB with Thermal Magentic Releas and adjustable overload setting complete with making connection if required with bus bar accordin gto the situation of the stie bus bar charges alongwith spreader thimble charges are also including in the AOR complete in all respect to the entire satisfaction EIC . Make L&T, Schineider, ABB.
100 to 125 amp 25K to 36 K
1000 Amp 3 pole 50K
Providing and fixing of rubber tyre coupling for the motor 40-50 HP motor with complete change of nut bolt, balancing with motor and pump for smooth running.
Providing and fixing of various size of copper thimble complete in all respect as per site requirement fitting, clamping with entire satisfaction of EIC.
35 Sqm with sleeve.
Repair and rewinding of various AHU motor complete with lifting from AHU and refixing on site.NSR
Providing and fixing of timer for Star delta operation including maing connection testing complete in all respect of approved make to entire satisfaction of EICNSR
Providing and fixing of Thermal overload relay compaitble with contractor block complete in all respect of approved make to the entire satisfaction of EIC The rate quoted should include site visit, detection of fault, and replacement with testingNSR
Providing and fixing of 3 pole power contractor block complete in all respect for 3 phase current rating as below including making connections of Make L&T series MNX or equivalent make/ model of other approved make to the entire satisfaction of EIC. The rate quoted should include the site visit, detection of fault and replacement with testingNSR
MNX 70/73 BCH
Providing and fixing place of old 70-80 watts LED light complete i/c control and power wiring in all respect to the entire satisfaction of EIC. Make: Oreva
Repair and rewinding of various cooling tower motor complete in all respect with lifting lowering from the site to the factory and factory to the site and proper balancing of the cooling tower with complete change of nut bolt complete in all respect.
Minor repair of cooling tower motor with change of thimbles of 7.5 HP Motor complete with the balancing and fixing and refixing again complete in all respect.
Repair and rewinding of sizes 40-50 HP Pump with motor including complete with mechanical seal, new impeller, lath work, work of pump changing of bearing, tyre coupling, carriage and fixing of motor with pump on site with all nut and bolt as required at site to the entire satisfaction of EIC including credit of old material. The rate is quoted should include the site visit, detection of fault and replacment with testing.
Providing and Fixing of various sizes V-belt for AHU complete as per site requirement.
B-39/ B-40/ B-45 / B-47/ B-51 as per required according to the motor
B-55 to B-58 as per required according to the motor
B-72 / B-77/ B-78 / B-80 / B-81/ B-92 as per required according to the motor
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.61 MB
BOQ_111045.xls
BOQ • 0.75 MB
Download all tender documents and submit your bid