Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (E)
O/o The Executive Engineer ( Electrical) 1ST Floor, Bhopal House, Lalbagh Lucknow
Comprehensive Maintenance of SAC for RLU Exchange in Cis Gomti Area Lucknow
2021_BSNL_88039_1
10/TEDL/BSNL/LKO/2021-2022 Dated 16/08/2021
Open Tender
Electrical Works
Item Rate
365 days
Lucknow
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL Lucknow
₹6,654
18 Oct 2021
13 Sept 2021
27 Sept 2021
13 Sept 2021
25 Sept 2021
13 Sept 2021
90 days
SH:I (Comprehensive maintenance):- Comprehensive Maintenance of SAC alongwith Voltage Stablizer for , RLU Exchange at Sharda Nagar, Dilkusha, SGPGI, Ganga Sinchai Puram, RML University, Patel Nagar, Sarojani Nagar, AP Sen Road Charbagh, Rajendra Nagar, La Touch Road, Chowk, Sadatganj, TalKatora, Rajaji Puram, Jawahar Bhawan, Council House and Japlin Road under Cis Gomati Area Lucknow as per details given in relevant section. SAC Units (As per inventory attached). (a) 1.5 TR Split AC
SH:I (Comprehensive maintenance):- Comprehensive Maintenance of SAC alongwith Voltage Stablizer for , RLU Exchange at Sharda Nagar, Dilkusha, SGPGI, Ganga Sinchai Puram, RML University, Patel Nagar, Sarojani Nagar, AP Sen Road Charbagh, Rajendra Nagar, La Touch Road, Chowk, Sadatganj, TalKatora, Rajaji Puram, Jawahar Bhawan, Council House and Japlin Road under Cis Gomati Area Lucknow as per details given in relevant section. SAC Units (As per inventory attached). (b) 1.5 TR , 3 Star Inverter Type Split AC
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (1) S/F folowing running/starting capacitor in WAC/ SAC units i/c connection, testing etc as reqd. (a) 36 mfd running capacitor.
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (1) S/F folowing running/starting capacitor in WAC/ SAC units i/c connection, testing etc as reqd. (b) 45 to 55 mfd running capacitor.
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (2) S/charging of refrigerant gas for in the refrigerant circuit of existing SAC unit, vacumising and leak testing etc as reqd.
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (3)Replacement of broken blower drum of 1.5 TR split AC unit i/c fixing, testing etc as required.
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (4) Replacement of rotary compresser of 1.5 TR i/c cutting ,welding brazing, vacumising and leak testing etc as reqd. ( M/S Emerson Kopeland or ss make).
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (5) Rewinding of out door fan motor of SAC unit 230 Volt 50 Hz A.C. supply i/c connection testing etc as reqd.
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (6) Replacement of 230 Volt 50 Hz A.C. supply blower motor of following makes in the existing 1.5 TR SAC i/c connection testing etc as reqd. (a) Voltas
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (6) Replacement of 230 Volt 50 Hz A.C. supply blower motor of following makes in the existing 1.5 TR SAC i/c connection testing etc as reqd. (b) Hitachi
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (6) Replacement of 230 Volt 50 Hz A.C. supply blower motor of following makes in the existing 1.5 TR SAC i/c connection testing etc as reqd.(c) LG
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (7) Replacement of following faulty items i/c connections, testing etc. complete as required. (a) 20 Amp. industrial socket metal clad
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (7) Replacement of following faulty items i/c connections, testing etc. complete as required. (b) 20 Amp. industrial plug metal clad
SUB HEAD-II ( One Time Rectification of Handing Over Defects of other than AMC SAC). (7) Replacement of following faulty items i/c connections, testing etc. complete as required. ©16/20/32 Amp. SP MCB 'C' series.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .