Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹44.6 L+₹9.0 L (25.4%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
Refer Docs
EMD Value
₹71,480
Closing Date
9 Sept 2021, 6:00 pmClosed
GE Sri Ganganagar
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri Ganganagar Cantt Rajasthan-335001
SPECIAL REPAIRS WORKS AT MILITARY STATION SRI GANGANAGAR
2021_MES_467369_1
GE SGNR/ TOK-37 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE Sri Ganganagar
D Class a(i) and b(i) and for un-enlisted, refer NIT para 8
6 documents required · 6 mandatory
₹500
GE Sri Ganganagar
₹71,480
Yes
13 Oct 2021
12 Aug 2021
11 Sept 2021
12 Aug 2021
9 Sept 2021
19 Aug 2021
Amount
M & L for sand filling (25 mm thick) under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer - in - Charge.
M&L for PCC (1:5:10) type E-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete or filling in sunken floor complete all as specified and directed by Engineer-in-Charge.
M&L providing cement concrete (1:3:6) Type C-1 (20 mm graded stone aggregate) for filling in pressed steel frames and other similar items etc complete all as specified and directed by Engineer - in - Charge
M&L providing precast cement concrete 1:2:4, Type B1 using 20mm graded aggregate as in kerb stone with solid blocks exc 10cm width and set in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
M & L brick work with fly ash bricks straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 complete all as specified and directed by Engineer - in - Charge.
M & L brick work with fly ash bricks straight or curved on plan exceeding 6 mtr mean radius built in CM 1:6 but except bricks complete all as specified and directed by Engineer - in - Charge.
S & F Second class hard wood glazed and skeleton shutter, kitchen cabinet shutters 35mm thick, open rebated and prepared to receive glass, gauze, etc divided into squares with plain, chamfered or rounded mitred and rebated sash bars any number & fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, section 8 clause 8.24 (a) complete all as specified and directed by Engineer - in - Charge.
S&F factory made 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engineer - in - Charge.
Taking down chowkats or frames (without taking off shutters from the frame) n. exc.1.5 sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down chowkats or frames (without taking off shutters from the frame) exc. 1.5 sqm and n. exc.4 sqm each complete all as specified and directed by Engineer - in - Charge.
Taking down shutters of any description exc. 1 Sqm but n.exc 2 sqm each and after easing/resecuring refixing in the same opening / place complete all as specified and directed by Engineer - in - Charge.
S&F Fiber Glass Reinforced plastic (FRP) Door Frames of required colour of three legged of cross section 90mmx45mm having single rebate of 32mmx45mm having single rebate of 32mmx15mm to receive shutter of 30 mm thickness. The laminate door frame molded with fire retardant grade unsaturate polysterresinn and chopped mat.Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiberglass from all sides, MS stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer - in - Charge
S&F 30mm thick glass fiber reinforced plastic (FRP) paneled door shutter of required colour and approved brand and manufacture made with fire retardent grade unsaturated polyster resin moulded to 3mm thick FRP laminated for forming hollow rails and style with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels for conforming to IS:14856-2000 complete all as specified and directed by Engineer - in - Charge.
S&F mild steel barrel tower bolts 250 mm, stove enamelled black, with bright bolt and fixed complete all as specified and directed by Engineer - in - Charge.
S&F Aluminium anodised barrel tower bolts 100 mm, stove enamelled black, with bright bolt and fixed complete all as specified and directed by Engineer - in - Charge.
S&F 300mm Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed by Engineer - in - Charge.
S&F butt hinges, medium weight, cold rolled mild steel, and fixed of size 100mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge.
S&F in repair butt hinges, medium weight, cold rolled mild steel, and fixed of size 100mm fixing properly with screws etc complete all as specified and directed by Engineer - in - Charge.
S&F 300 mm size mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified & directed by Engineer-in-Charge.
S&F Extruded aluminium alloy handles, fabricated type, anodised 200 mm long complete all as specified and directed by Engineer - in - Charge
S&F mild steel handles,oval type stove enamelled black 150 mm long complete all as specified and directed by Engineer - in - Charge
S&F drapery harrison rails/curtain rod 25 mm dia (minimum weight 0.36 Kg per RM) with brackets, fancy knobs and rings (20 cm c/c) etc complete all as specified and directed by Engr-in-charge.
S&F brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed by Engineer-in-Charge.
S&F Galvanised steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.00mm and fixed to window / ventilator with stainless steel wire staples complete all as specified and directed by Engineer - in - Charge
S&F Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets, etc. Fe 410-W(gde E-250 Quality 'A' complete all as specified and directed by Engineer - in - Charge.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded.complete all as specified and directed by Engineer - in - Charge.
S&F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded.complete all as specified and directed by Engineer - in - Charge.
S&F in repair steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing/gauze , dovetailed or welded.complete all as specified and directed by Engineer - in - Charge.
M&L for Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. with Powder Coating on aluminium minimum thickness of powder coating 50 micron as per the specification top and bottom horizontal members and vertical members adjacent to walls and cills where required and fixing with the help of rawl plug and screw or with fixing clip or with expansion hold plate fasteners. Aluminium section shall be smooth, rust free, straight mitred and jointed mechanically where ever required complete all as specified and directed by Engineer - in - Charge.
S&F powder coated aluminium windows and ventilator luver shutters, side hung type without sash bars, aluminium saction weighing 0.55 kg/M including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting such as aluminium peg stay 150mm long (1No), powder coated aluminium hinges type B-21 100 mm long (2No), suitable powder coated aluminium handle -(1No), and powder coated aluminium self closing tower bolt 75mm long (1No) complete all as specified and directed by Engineer - in - Charge.
M&L for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer-in-charge.
S&F heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner complete all as specified and directed by Engineer-in-charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including fittings complete all as specified and directed by Engineer-in-charge.
M & L for 18-20 mm thick machine cut kota stone slab as in vertical surfces such as skirting, dados, laid over and including 10 mm thick backing coat in CM 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge.
M & L for 18- 20 mm thick (minimum size 55cmx 55 cm) machine cut kota stone slab flooring laid over and including 15 mm thick screed bed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed by Engineer - in - Charge.
M & L for 75 mm thick cement concrete 1:3:6 type C –2 (40mm graded stone aggregate) as in plinth protection or similar works finished even and smooth with using extra cement etc complete all as specified and directed by Engineer - in - Charge.
M&L for 75mm thick cement concrete (1:4:8) type D-2, (40 mm graded stone aggregate) as in sub base, foundation filling and mass concrete complete all as specified and directed by Engineer - in - Charge
M&L for 25 mm thick cement concrete 1:2:4, Type B-0 (12.5mm graded aggregate) as in floor finished even and fair complete all as specified and directed by Engineer - in - Charge.
M&L for precast coloured rubber moulded concrete machine pressed concrete interlocking paver blocks any shape and size conforming to IS 15658-2006 of 60 mm thickness, M 35 grade set, jointed and pointed in neat cement slurry in floors/paving/path etc wirh grey cement and pigment complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed by Engineer-in-charge.
M&L for glazed ceramic coloured tiles interior grade, of size 450x350x7mm thick as on vertical surfaces like dados or skirting laid over and including 10mm thick rendering in CM 1:4 and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
M&L for non skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exc. 0.11 sqm but not exc 0.18 sqm in floor etc, laid over and including 15 mm thick screed bed in CM 1:6 and set and jointed in cement slurry and pointed in white cement mixed with pigment to match the shade of tiles complete all as specified and directed by Engineer - in - Charge.
Taking down cement plaster on brick or concreate wall surfaces including racking out joints, hacking for key, scrubbing down with water etc. complete complete all as specified and directed by Engineer-in-Charge.
M&L granite (of any type) work 20 mm thick (table rubbed and polished) in partition like CM 1:4 including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15 mm thick in CM 1:4 on brick work or concrete work surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L 15 mm thick rendering in CM 1:6 on brick / concrete wall surfaces including finished even & smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L, 5mm thick rendering in CM 1:3 on fair faces of concrete surfaces as on ceilings finished even and smooth without using extra cement complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper, over a coat of chalk whiting with putty complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surfaces of walls with putty and applying two coats of cement based paint over a coat of white wash complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old decorated wall surfaces by brooming down or steel wire brushing,scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spots and then applying two coats of cement base paint with putty complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old decorated plastered or un-plastered surfaces of walls by brooming down or steel wire brushing, scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spots and applying two coats of oil emulsion distemper complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plaster surfaces of ceiling and applying three coat of white wash complete all as specified and directed by Engineer-in-charge.
M & L for old decorated ceiling surfaces by brooming down or steel wire brushing,scrapping down smoke soot,moulds,moss and efflorescent salts and trading oil and greasy spots and then applying one coat of white wash complete all as specified and directed by Engineer - in - Charge.
S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sqm the each pane complete all as specified and directed by Engineer - in - Charge.
S&F 4 mm thick Figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new wood and wood based surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of Pink primer complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of old wood and wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed by Engineer - in - Charge.
M&L for preparation of new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide, zinc chrome primer complete all as specified and directed by Engineer - in - Charge
M&L for preparation of old steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed by Engineer - in - Charge
S&F Galvanised steel water tubing 15 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S&F Galvanised steel water tubing 20 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
S&F Galvanised steel water tubing 25 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge.
Fixing only Galvanised steel water tubing 15mm bore with new fitting including cutting chases to brick wall /ceiling or laying in floors and making good disturbed surfaces complete all as specified and directed by Engineer-in-Charge. Note;- Serviceable GI pipe obtained Srl item No 92 shall be re-used.
Fixing only Galvanised steel water tubing 20mm bore with new fitting and fixed to walls, ceiling or laid in floorscomplete all as specified and directed by Engineer-in-Charge. Note;- Serviceable GI pipe obtained Srl item No 95 shall be re-used.
Fixing only Galvanised steel water tubing 25mm bore with new fitting and fixed to walls, ceiling or laid in floorscomplete all as specified and directed by Engineer-in-Charge. Note;- Serviceable GI pipe obtained Srl item No 95 shall be re-used.
Taking down 15 mm bore Galvanised steel water tubing with all fittings complete all as specified and directed by Engineer-in-Charge.
Taking down 20 mm bore Galvanised steel water tubing with all fittings complete all as specified and directed by Engineer-in-Charge.
Taking down 25 mm bore Galvanised steel water tubing with all fittings complete all as specified and directed by Engineer-in-Charge.
Dismantling and taking down water tank of capacity exc. 500 Litre but n. exc. 1000 litre capacity complete all as specified and directed by Engineer - in - Charge.
S&F rotational moulded white colour polyethylene water storage tank 1000 litre capacity (Cylindrical vertical with closed top) hoisted and fixed in position with necessary fittings complete all as specified and directed by Engineer - in - Charge. (Note : PVC tanks shall be ISI marked, having two layres and white colour)
S&F in repairs 15mm bib tap cast copper alloy, with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferule complete all as specified and directed by Engineer-in-Charge.
S&F high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc. Bore of pipe 32 mm complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore angle stop cock / valve cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe (concealed type) complete all as specified and directed by Engineer-in-Charge.
S&F 15mm bore angle stop cock / valve cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore angle stop cock / valve cast copper alloy,screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed by Engineer-in-Charge.
S&F 20mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe (minimum weight 210gms) complete all as specified and directed by Engineer - in - Charge.
S&F in repairs , 20mm bore Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe (minimum weight 210gms) complete all as specified and directed by Engineer - in - Charge.
S&F grating doom 100 mm dia of PTMT fixed complete all as specified and directed by Engineer-in-Charge. Note:- Minimum weight 25gms
S&F Shelf of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 300gms) complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC connections 15mm size with PTMT nut of length 600mm complete all as specified and directed by Engineer-in-Charge.
S&F 100mm dia bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or fixed to wall complete all as specified and directed by Engineer - in - Charge
S&F 75mm dia bore sand cast, cast iron soil, waste and vent pipes in any length with or without ears with cement joints laid in trenches or fixed to wall complete all as specified and directed by Engineer - in - Charge
S&F 100mm bore cast iron Bends (any radius),with duck's foot or heel rest diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F 75mm bore cast iron Bends (any radius),with duck's foot or heel rest diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
S&F 75mm dia Cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
S&F chromium plated shower rose of size 125mm with or without shivel joints including fixing to pipe or union complete all as specified and directed by Engineer - in - Charge.(Minimum weight 400gms)
M&L 110 mm PVC (SWR) pipes single socked in any length with rubber ring joints, fixed to walls all as specified and directed by Engr-in-charge.
S&F 110mm bore PVC (SWR) bends of with oval access door complete all as specified and directed by Engineer-in-Charge
S&F vitreous china urinal, bowl type (back or corner wall type), complete including providing and fixing plugs bedding urinal against wall in cement mortar 1:2, securing urinals to plug with and including 60mm long brass screws and brackets, 32mm bore LDPE flush pipe of pressure rating 6 Kg/ Cm2 and grating and union for discharge pipe, waste coupling of PTMT minimum weight 45 gm, including urinal spreader of PTMT any colour for fixing with 15 mm dia pipe complete all as specified and directed by Engineer - in - Charge
M&L for Urinal partitions slabs terminating about 40cm above floor line complete all as specified and directed by Engineer - in - Charge
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white excluding fixing bolts, flushing cistern and flush pipe, including plastic water closet seat, black cosed pattern with flat bottom, and cover and mild steel chromium plated hinging device complete all as specified and directed by Engineer - in - Charge.
S&F in repairs water closet vitreous china squatting pan "Orrisa pattern" size 580mmx440mm white with integral foot rests (Excl flushing cistern) complete all as specified including CI 'P' trap all as specified and directed by Engr-in-charge.
S&F in repairs 10 litre capacity low level PVC valve less, syphonic action type flushing cistern, white, with inlet, ball valve, float and handle including bracket and provision of flush pipe of polythene of high density or PVC, 15mm dia and 450 mm long complete all as specified and directed by Engineer-in-Charge.
S&F in repairs vitreous china wash hand basin white, flat back size 550x400mm including brackets, waste coupling 32mm dia of brass Chromium plated, 15mm dia pillar tap of cast copper alloy with capstan head screwed down, high pressure, with or without letter "Hot or Cold" with long screwed shank and fly nuts, 32mm dia, waste pipe low or high density polyethelene of pressure rating 6 Kg/Sqm and PVC connection with PTMT nuts of 15mm dia and 450mm long cutting for and pinning in end of brackets or erecting stand etc. complete all as specified and directed by Engineer - in - Charge.
S&F vitreous china white soap dish 160x160x90 mm fixed with screws complete all as specified and directed by Engineer - in - Charge
Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed by Engineer - in - Charge
Demolition of cement concrete in ground floor and paving n. exc. 15cm thickness (below or above ground level) of any description complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer - in - Charge.
Dismatiling brick tiles or terracing tiles, single layer on roofs complete all as specified and directed by Engineer - in - Charge.
Dismantling galvalume sheet (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed by Engineer - in - Charge.
Demolation Mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed by Engineer - in - Charge.
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below complete all as specified and directed by Engineer-in-Charge:- (a) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. (c) Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:4:8 thickness 50mm over the coating as per requirment (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete all as specified and directed by Engineer-in-Charge. Make:- Dr. Fixit/Fosroc/STP/Sika Note: (i) PCC filling in sunken portion will be measured seperately.
M&L for Roof treatment to RCC roof as follows :- (a) Cleaning the roof surfaces thoroughly using wire brushes to remove sharp projections,cleaning joints,washing,drying and removing all dirt/dust to receive concrete padding/ plaster etc complete. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC , finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @ 100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP based polymeric membrane,(mineral finish) minimum weighing 3 Kg/Sqm reinforced with non woven polyster fabric (weight not less than 150 gms/Sqm) by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by Engineer-in-Charge. Makes:-STP/ Dr Fixit/Pidilite,Texsa India Ltd Notes: (i) All joints and change in directions should be covered with cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/ as per site requirement and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only.The name of firm shall be got approved from GE before carrying out the work. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarantee of treatment shall be for minimum 10 years reckoned from date of completion of whole work
Excavation in trenches in n.exc. 1.5 m wide & n. exc. 1.5m in depth in soft/ loose soil for laying of cable complete all as specified and directed by Engineer - in - Charge
Returning filling in, including spreading levelling, watering and well ramming in layers not exc. 25 cms thick in soft/ loose soil complete all as specified and directed by Engineer - in - Charge.
Removing excavated material n. exc. 50 m & depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer - in - Charge.
Supply & filling/ laying a layer of dry coarse sand 8 cm thick before laying ofcable and 15 cm thick after laying of cable complete all as specified and directed by Engineer - in - Charge. Note:- After punning drain 18 cm will be measured for payment.
M&L for brick protection layer with one brick wide using sub class ‘B’ bricks laid flat across the cable complete all as specified and directed by the Engineer in charge.
Supplying, laying and testing 25 Sqmmx4 core XLPE insulated, heavy duty electric cable with aluminium conductor 1100 V grade conforming to IS-7098 laid in trenches/ducts/fixed on poles wall/ laid under roads/paths/ drain/ culverts or passing through pipes complete all as specified and directed by engineer in charge.
Taking down copper/aluminium point wiring (light,fan,socket or power)complete including fixture and fittings such as switches& sockets and removing materials for taking credit complete all as specified and directed by Engineer-in-charge.
M&L for concealed conduit point wiring complete with cable 1.5 sqmm(Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC conduit pipe medium grade 20mm bore,pipe hooks,elbows,junction covers and junction boxes, after cutting in wall chasing for conduits and sinking's for sunken cast iron /pressed steel terminal boxes 60 mm deep of suitable length and 1.2 mm thickness for mounting switches, sockets, fan regulator with 3mm thick plastic laminated seat cover fixed with brass screws and cup washers, duly grouting and painted with red oxide metal primer and making good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth contuity conductor along with point wiring of 1.5 sqmm copper FRLS PVC insulated cable for point controlled by one way switch and connected to common earth dolly, complete all as specified and directed by Engr-in-charge.
All as described in Srl item No -143 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -143 here in before but for one switch socket combination 5/6 Amps on independent board complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No -143 here in before but for one light point controlled by two ways switches complete all as specified and directed by Engineer - in - Charge.
All as described in Srl item No. 141 here in before but for one switch socket combination 6 pin 5/15 Amps on independent board with 2.5 Sqmm (Nominal Area) FRLS PVC insulated multistranded unsheathed copper conductor and continuous earth contuity conductor along with point wiring of 2.5 sqmm copper FRLS PVC insulated copper cable complete all as specified and directed by Engineer - in - Charge.
S&F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S&F switch piano flush type 5/6 Amp single pole one way complete all as specified and directed by Engineer - in - Charge
S&F Socket outlet 5 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.
S&F switch socket combination 5 pin, 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge
S&F Switch socket combination 2 in 1, 6 pin , 15/16 Amp flush universal type all as spd and directed by Engr in charge.
S&F in replacment MCCB TPN 63 Amps with breaking capacity 16 KA, fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S&F in replacment MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S&F in repairs MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S&F in repairs sheet metal enclosure for double door DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S&F ceiling rose, surface bakelite 65x50 mm three terminals complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick burried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 4 mm dia GI earth wire, by means of bolts, nuts check nuts and washers of galvanised iron and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (wieght not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point including taking our unserviceable earthing with all acessories all as specified or indicated including testing on completionall as specified and directed by Engineer - in - Charge.
S&F in replacement sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn and including steel dia "medium quantity" PVC conduit including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surface and white wash or existing colour, necessary junction box and cover including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge.
S&F stepped type,single socket fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge
S&F Exhaust fan with high speed noiseless motor of size 250-300 mm sweep,5 star rating heavy duty metal body by grouting both ends in wall upto required length and making hole of suitable size in wall, making good the existing surface and connecting with ceiling roses with and including flexible cable 3 core copper conductor of size 24/.2 mm from ceiling rose to fan complete including breaking of brick wall and making a hole for fixing of exhaust fan of suitable length with frame. louvers, nuts, bolts etc. including making good disturbed wall in CM(1:4) complete all asspecified and directed by Engineer - in - Charge. Make- Crompton/Bajaj/Havell's/Orient
S&F in repairs sheet metal enclosure for double door virtical DB's made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounting VTPN 4 ways, 415 Volts, 250 amps bus bar, stove enamelled dust and vermin proof, IP:43 protection suitable for incorporation FP MCCB (v-Tech) N1 Frame upto 125A, isolators and including give connection with wire and cable etc complete all as specified and directed by Engineer - in - Charge.
S&F in replacement MCB protected Socket -25Amps with plastic box and plug top vertical Din rail mount type suitable to operate at 240V current rating range 25A , 50Hz 1Ph, complied IS specification 13032 & 8623 complete all as specified and directed by Engineer - in - Charge.
S&F in replacement extruded aluminium LED batten channel 20 watt having input voltage AC90-300V, 50Hz, 6500K, with white acrylic cover tube light fitting wall mounted complete with rod, driver and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS20WLED865SPCSS, Bajaj cat part No. BCLSBAL 20W CW, Crompton cat part No. CCS-100-20-65-HL2-DP-NWH
S&F LED lamp 9 W for angle holder complete all as specified and directed by Engineer - in - Charge.
S&F in repairs water tight bulk head fitting, comprision of connector galvanised cast iron back plate, weather proof enamelled gallery, glass well and including 10 watt LED lamp complete all as specified and directed by Engineer-in-Charge. Make :-Havells cat part No. HEXAFT10WLED857SSYMBOPC, Bajaj cat part No. BIBWP 10W LED, Crompton cat part No. LBHP-10-CDL
S&F in replacement decorative wall light fixture made up of poly carbonate suitable for 10 watt LED lamp complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LHFOFWE1TZ1W012 or equivalent Bajaj, Crompton
S&F in replacement security light fitting LED TYPE 25 watt with all necessary accessories, Clear transparent acrylic cover, prewired suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. ENDURAPEARLSL25WLED757SASYTOPCMP, Bajaj cat part No. BRLEP 25 W, Crompton cat part No. LSTS-25-CDL-M
S&F in replacement compact decorative energy efficient LED mirror light fitting with antiglare diffuser and decorative end caps suitable for 1x10 watt fitting 2 ft version including LED lamp 10 watt complete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. LUMILINEPLUSBS10WLED865SPCSS, Bajaj cat part No. BCLSB 10 WH, Crompton cat part No. LDL-10-CDL
S&F switch piano flush type 5/6 Amp single pole two way complete all as specified and directed by Engineer - in - Charge
S&F in replacement LED suspension light fitting 36 W (fixture size: (LxWxH) in 1136x54x74 mm), extruded aluminium direct-indirect light effect gives homogenous light distribution effect & enhances the visual comfort with joining kit accessories and connecting to main cable omplete all as specified and directed by Engineer - in - Charge. Make :-Havells cat part No. DESTELLODILP36WLED857SPMMAWH, Crompton cat part No. LCLP54-36-CDL or equivalent make in bajaj
Supplying, installation, testing and commissioning of battery charger FCBC 24V/100Ah, input 230V AC+/-15% (SMPS based) output 15 Amp DC with panel size of height 1075mm, width 600mm, Depth 5000mm suitable for fixing in sub stn complete all as specified and directed by Engineer - in - Charge.
Supplying, installation, testing and commissioning of battery bank 24V/100Ah, VRLA complete all as specified and directed by Engineer - in - Charge.
Supplying, installation, testing and commissioning of battery power bank DC 230V/24V 33 KV panel in Sub station complete all as specified and directed by Engineer - in - Charge.
M&L for making PCC cable duct with inner dimensions of size 450mmx450mmx450mm for laying of control cables. Cable duct should hass PCC bed of 20mm thick and PCC walls 40mm thick with PCC cover of suitable size for cable duct and filling of sand for cable cushioning complete all as specified and directed by Engineer - in - Charge.
S&F of FRLS PVC flexible DC wire/cable (copper conductor) size of 2.5 sqmm 12 core complete all as specified and directed by Engineer - in - Charge.
Note : Notes : (i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
ISHAAN CONSTRUCTIONS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .