Loading…
Loading…
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
10 Aug 2026, 3:30 pmClosed
Ajmer Division-"Ajmer Division Provision of CCTV at DRB, DET, NDT Goods shed at loading and unloading points (DRB, DET & NDT Balance work)."
SNT-AII-32-2026-27~NWR
SNT-AII-32-2026-27
Open
Works - General
180 Days
Ajmer, Rajasthan
₹0
₹3.0 L
10 Aug 2026
13 Jul 2026
27 Jul 2026
A-"Ajmer Division Provision of CCTV at DRB, DET, NDT Goods shed at loading and
Supply of DLP trunk 32X20mm with required all changeable internal/external angle, changeable flat angle, flat junction. Clips, joint for cover, end cap etc. make Legrand or superior. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.
Fixing & wiring (Laying) of DLP trunk 32X20mm with required all changeable internal/external 2 angle, changeable flat angle, flat junction. Clips, joint for cover, end cap etc. make Legrand or superior. Cable will be supplied by Railway and all other fixing material will be supplied by contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after execution.
Supply of 8 port Gigabit Lite Managed PoE Layer 2 Switch supports 8 nos 10/100/1000BASE-T 3 ports, along with 2 Gigabit SFP ports, green-saving technologies, make model DG-GS1510HPL DIGISOL / CISCO/JUNIPER or superior. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.
Supply of 24 port Layer3 network switches with 4 Nos. 10/100/ 1000 Base-T/1000 Base-X SFP ports make model DG-GS4628SE DIGISOL /CISCO/JUNIPER or superior. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.
Supply of Small Form- Factor Pluggable(SFP) as per IEEE standard: IEEE 802.3z, Connector type: 5 LC type, Wavelength(nm): 1310 nm, Fibre type: Single mode, Max cable distance: upto 20 km. Make & modelDG-SA1133-20 DIGISOL/Netgear/Cisco or similar. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.
Supply of OFC single mode 6 fibre unarmoured cable. Make Molex/ AMP/Finolex or similar. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after supply.
Supply of UTP CAT-6 cable in a roll of 305 meter and make Siemen/ Systemax / Panduit/ Tyco/ Krone/ AMP. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.
Supply, installation and complete wiring of optical fibre cable termination box for 6 fibres 8 complete with base housing, base mountings with fixing arrangement etc. & splicing of fibre with low loss of pigtail cables. Splice losses in no case should be more than 0.1 dB. Necessary 0dB connectors should be provided in OFC termination box. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after execution.
Supply of 750 VA Off line UPS with battery backup 3 Hours for Failure Analysis System of reputed make of Emerson/APC or superior as per Engineer in-charge. Inspection: Consignee, Inspection charges: None Payment terms:100 % after supply.
Supply of SC/APC -LC/PC patch cord (5 meter) (3M, TE connectivity, R&M make or superior) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.
Supply of SC-APC/SC-APC patch cord (1 meter) (3M, TE connectivity, R&M make or superior) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply.
Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately 12 before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution( Unit is Cubic Meter)
Supply of Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 or latest. The item also includes supply of all the accessories of HDPE duct like 13 end caps, collars, bends, couplers etc. Inspection: (i) RDSO/RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply
Laying of Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. 14 RDSO/SPN/TC/45/2013 Rev. 2.0 or latest. The item also includes installation of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution.
Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per instructions of engineer incharge at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution.
Supply, installation and complete indoor wiring of 19 inch covered Rack of size 2035 mm x 600 mm x 600 mm (Approx.) as per Drg. No. CSTE/NWR/SOR/24. The rack shall be complete with all fittings for 16 housing SDH equipments, Primary MUXES, DDF, MDF using crone modules and other equipments like runway ladders etc completely wired and equipped with integrated protection modules for all channels as per technical specifications and other stipulations of tender document. It should be possible to lock all the equipments with only order wire telephone remaining outside the rack. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution.
Supply & Installation of Professional 19" Equipment Racks 12U for housing of network equipment. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution.
Supply, installation & commissioning of HDMI Cable with connectors for Connectivity between Audio visual system Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after commissioning.
Supply of power cable 3 core 2.5 sq mm multi strand (36/0.3 mm dia) cable as per IS 694:1990 reaffirmed 1995 or latest suitable for railway electrification area shall be of reputed make like Delton, LAPP, Finolex, or superior. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after supply.
Supply, installation & commissioning of 8 port HDMI splitter Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after commissioning.
Horizontal Drilling by using manual pushing method at minimum depth of 1.5 meter below the formation level of earth as per decision of Engineer in charge .Pipe Supply is not covered under this item Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution
Horizontal direction drilling/boring without damage of surface road /track using Auger Machine(HDD machine). The bore shall be upto 200 mm dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. 22 The length of the bore shall be minimum 4 Mtrs long. This include insertion of different dia DWC-HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note:- Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. Unit
B-Ajmer Division Provision of CCTV at DRB, DET, NDT Goods shed at loading and
Supply, installation, testing, wiring & commissioning of Full HD Resolution Large Format Display LED Monitor Screen Size 55" (inches) or larger as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest.
"Supply of Server. Intel CoreTM i5-7400 Processor 3.0 Ghz,Gigabyte H110m Motherboard with 2 HDMI,DDR4 8 Gb RAM, USB 3.0,4GB inbuilt Graphics,1 TB HARD DISK Hard Drive Interface SATA,Hardware Platform Windows,Operating System-Windows 10 (Licensed) with Keyboard and optical mouse Make HP, Lenovo, Dell."
Supply, Installation, testing, wiring & commissioning of PC Workstation as per RDSO Specification No RDSO/SPN/TC/65/2021 Version 6.0 or latest.
Supply of surveillance Hard Disk Drive of 6TB capacity with 64 MB cache and SATA 6 Gb/s interface for DVR/NVR of standard make
Installation, testing and commissioning of surveillance Hard Disk Drive of 6TB capacity with 64 MB cache and SATA 6 Gb/s
Supply of Server Hardware for Video Analytics and all other required accessories to make the system operational, as per RDSO Specification RDSO /SPN/TC/65/2021 Rev.6.0 or with latest amendment. (Inspection by RDSO)
Supply and Commissioning of Video Analytics Software with License as per RDSO Specification 7 RDSO/SPN/TC/65/2021 Rev.6.0 or with latest amendment (Per camera License means Video analytic at multiple locations such as tation/Goods Shed /Central Monitoring/Other Monitoring locations & Server room by same license.) (Inspection by RDSO)
Supply of Server Hardware for Video Management & Recording and all other required 8 accessories to make the system operational, as per RDSO Specification RDSO/SPN/TC/65/2021 Rev.6.0 or with latest amendment. One server should be configured as a Redundancy server in the N:1 configuration at each location. (Inspection by RDSO)
Supply, Installation, Testing & Commissioning of Video Management & Recording Software with 9 License as per RDSO/SPN/TC/65 /2021 Ver.6.0 or latest (Per camera Licence means Video anagement (Viewing) at multiple locations such as tation/Goods Shed /Central Monitoring/Other Monitoring locations and Server Room by same licence.
Supply, Installation,Testing and Commissioning of Storage System for 30 days (37TB) recording 10 as per Spec.No:RDSO/SPN/TC/65/2021 Ver.6.0 or with latest amendment at station/Goods Shed /Central Monitoring/Other Monitoring locations along with all accessories required for installation purposes (Inspection by RDSO)
Supply of Full HD Bullet/Dome Type IP Colour camera as per Spec. No:RDSO/SPN/TC/65/2021 Ver.6.0 or latest
Installation, Testing & Commissioning of Full HD Bullet/ Doom IP Colour camera along with the mount. All the accessories and fixing materials including mount required for this installation are to be supplied by contractor within the same cost.
Supply, Installation, Testing and Commissioning of Full HD PTZ type IP Colour Camera along with 128 GB or Higher SD Card,housing and mount and all accessories required for installation purposes as per RDSO SpecNo RDSO/SPN/TC/65/2021 , Rev 6.0 or with latest amendment. (Inspection by RDSO)
Supply and Installation of 28 port Fiber Switch with 24 SFP and 04Combo Ports of Make Techroutes/DLink/ Digisol/Novel/ Cisco or similar.
Supply and erection of 15 feet GI pipe of 4'' dia of medium quality ISI No 1230 (part 1) 1990. Having iron base plate 10mm thick 30cm x 30 cm weild at the bottom of the pipe with 4 supports of iron bars 15 of size 10mm dia. The 3 feet pipe shall be burried in the ground and 12 feet shall be above the ground. The work includes digging of pit on platform, laying of cable, erection of pole, filling the pit with 1:3:4 cement, concrete and sand. Final plastering should be done on the surface. The iron bracket on the top of the pole shall be provided for the fixing of CCTV camera and junction box/6U outdoor cabinate etc. (Necessary fixing and other materials required for fixing should be borne by the contractor)
Supply of 6U Outdoor cabinate enclosure IP66 complied pole mount similar to Rackom 6UIP66 or similar
Fiber Splicing and testing of Spliced Joint.
Laying of UTP/OFC/CAT-6 cables in 1 inch PVC conduit pipe/casing caping with suitable clamping. (PVC conduit pipe/ Case Caping & other accessories are to be supplied by the contractor.)
Laying of Power cables in 1 inch PVC conduit pipe/casing caping with suitable clamping. (PVC conduit pipe/ Case Caping & other accessories are to be supplied by the contractor.)
Supply of RJ 45 Connector D-Link or DAX Make as per instruction of Site Engineer
Supply of CAT - 6 Patch cord 10/100/1000BaseT applications with 24 AWG sheath and LSOH with RJ 45 Connector 10 mete long
Supply, Installation, Testing & Commissioning of Core Switch as per RDSO Specification RDSO/SPN /TC/65/2021 Rev.6.0 or with latest amendment.
Supply, Installation, Testing & Commissioning of 24 Port Layer 2 POE Switch as per RDSO Specification RDSO/SPN/TC/65/2021 Rev.6.0 or with latest amendment. (Inspection by RDSO)
Supply, Installation, Testing & Commissioning of Field Switch 8POE port and 2 Nos of 1G Optical port as per Spec. No: RDSO/SPN/TC/65/2021 Ver.6.0 or latest
Supply, Installation, Testing & Commissioning of Agregate Switch as per Spec. No: RDSO/SPN/TC/65/2021 Ver.6.0 or latest
Supply, Installation, Testing & Commissioning of 10 KVA UPS including suitable Rack as per specification in Annexure attached. Make: Luminous, APC, Microtek. (Inspection by RITES)
Supply of PVC Pipe 1' & 1.5 MM Thickness
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCOF2022.pdf
ATTACHMENT
ACS-1GCC2022_merged_compressed.pdf
ATTACHMENT
SNT-AII-32-2026-27-AjmerDivision-ProvisionofCCTVatDRBDETNDTGoodsshedatloadingandunloadingpointsDRBDETNDTbalance.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .