| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.3 LAccepted-AOC 191 ROHI BHARWARI KAUSHAMBI 212201 | KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹52.7 L+₹5.4 L (11.4%)Rejected-Finance 307 SADAR BAZAR LUCKNOW UP 226002 | LUCKNOW | UTTAR PRADESH | 226002 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹54.6 L+₹7.2 L (15.2%)Rejected-Finance 13 R N BAHUGUNA MARKET HASTING ROAD PRAYAGRAJ | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹54.8 L+₹7.4 L (15.7%)Rejected-Finance NH 17 MAIN ROAD BINAGA BAZAR KARWAR 581307 | KARWAR | UTTARA KANNADA | KARNATAKA | 581307 | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹58.2 L+₹10.9 L (23.0%)Rejected-Finance | L5 | Rejected-Finance Being not lowest |
Tender Value
₹58 L
EMD Value
₹1.1 L
Closing Date
30 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
CWE AF BAMRAULI
PROVISION OF PERIMETER SECURITY LIGHTS ALONG WITH STANDBY POWER SUPPLY AN ALLIED WORKS AT AF STATION BAMRAULI
2023_MES_625939_1
87330/E8
Open Tender
Electrical and Maintenance Works
Item Rate
182 days
Bamrauli Prayagraj
Class C Category b i and other criteria as per NIT and Tender Doc
8 documents required · 8 mandatory
₹1,000
GE AF BAMRAULI
₹1.1 L
Yes
19 Jan 2024
31 Oct 2023
6 Jan 2024
31 Oct 2023
30 Dec 2023
16 Dec 2023
31 Oct 2023 - 13 Nov 2023
Amount
Supply, commissioning erecting and testing complete of manufacturer or OEM manufactured, static silient (sound proof enclosure) Diesel Engine driven Generating set of capacity 30 KVA, water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable for conditions prevalent at Bamrauli (capacity of engine, alternators shall worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height), anti-vibration pads complete all as specified and directed, including all feature to comply with CPCB-IV + norm and comprising of followings:-
DIESEL ENGINE Diesel engine 1500 RPM, direct injection,3 cylinder, four stroke, conforming to conforming to IS:100001/ISO 3046/BS:649/BS:5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 30 KVA at outdoor atmospheric conditions at Bamrauli ( Taking all derating factor into consideration) fitting with the following accessories subject ot the design of manufacturer:-
(i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type (iii) Electronic Governor class 1 A with back up Mechanical governor class 1A Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level (v) Radiator cooling (vi) Radiator fan with guard (vii) Vaccum indicator (viii) Fuel filter and fuel houses (ix) Fuel injection pump (FIP) (x) Fan and water pump assesembly
(xi) Lub oil filter and pump (xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maint free lead acid bty as per manufacturer recommendation including inter connecting cables/leads with terminals complete with starting/stopping switch voltmeter, etc 01 set (xiii) Engine safety shut down system against low oil pressure and high water pressure (xiv) Exhaust gas driven turbo charge (xv) Oil filter (xvi) Lub oil cooler (xvii) Engine main manual with spare part list (xviii) Suitable designed acoustic enclosure as per CPCB regulations (xix) Any other item not included / specified but is a standard design of the manufacturer.
Engine instrument panel : Engine instrument panel shall comprising of the following:- (i) Starting on /off switch. (ii) water temp auge. (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure. (viii) Any other item not included/specified but is a standard design of the manufacturer.
ALTERNATOR (Make: Kirloskar electric co/ Crompton/ Stemford) shall be self excited, self regulated, brush less for 30 KVA continous operation at the speed of 1500 RPM at 415 volts, 50Hz three phase, 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible couping and conforming to IS-4722 complete-01 No. Note:- Alternator should be able to deliver output rating at actual site condition.
Common fabricated base frame for engine and alternator made from structural channel, jerk proof PCC 1:2:4 mix type B1 foundation including adequate number of suitable anti-vibration pads all as per manufacture recommendations is deemed to be included in the unit rate quoted by the contractor.
Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy with fuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per engineering practice complete all as specifided and directed.
Bypass arrangement by providing separate panel made out of 3mm thick CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 63 Amp is to be installed near AMF panel complete all as specified and directed. (i) Hour run meter. (ii) Any other item not included/ specified but is a standard design to the manufacturer.
AMF CONTROL PANEL: Supply, fabricating and testing of factory mounted cubical automatic main failure panel with degree of protection IP-42 conforming to IS-2147, suitable for 30 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories:-
(i) Master switch for auto/manual/reset/off-01 No. (ii) Ammeter digital type, 96X96 mm with CT's-03 Nos aux supply 230 vlts, AC, acuracyclass 1. (iii)Voltmeter digital type 96x96 mm to read 0-500 volts supply 230 volts, accuracy class 1.0. (iv) Digital frequency meter-01 No aux supply 230 volts, AC (v) Push button start, stop, reset-01 No. (vi) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (vi) Battery charger connected to load. (vii) Transformer of adequate rating. (viii) Ractifiers
(ix) DC ampere meter and voltmeter. (x) Fault accept / reset push button. (xi) Set of relays and contactor suitable for 62.5 KVA DG Set for automatic start and automatically shut down of suitable rating and capacity adjustable to 70 to 100% and 2 Nos MCCB 4 pole, 63 Amp, 16 KA fixed on main supply and DG set supply. (xii) Make of AMF control panel shall be as per OEM recommendations.
Supply, commissioning erecting and testing complete of manufacturer or OEM manufactured, static silient (sound proof enclosure) Diesel Engine driven Generating set of capacity 20 KVA, water cooled, 415 volts (AC three phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with control panel standardized by manufacturer, fuel tank with mounting arrangements and inlet, outlet return inlet oil arrangements, exhaust pipe complete and suitable for conditions prevalent at Bamrauli (capacity of engine, alternators shall worked out taking all derating factors into consideration) including PCC foundation (of suitable size leaving at least 0.5m all around for ease of movement and 0.5m height), anti-vibration pads complete all as specified and directed, including all feature to comply with CPCB-IV + norm and comprising of followings:-
DIESEL ENGINE Diesel engine 1500 RPM, direct injection, 3 cylinder, four stroke, conforming to conforming to IS:100001/ISO3046/BS:649/BS:5514 amended upto date, for continous running capable of taking 10% overload for one hour in 12 hour, water cooled, naturally turbo charged, capable of giving adequate BHP to drive Alternator capable of delivery 20 KVA at outdoor atmospheric conditions at Bamrauli ( Taking all derating factor into consideration) fitting with the following accessories subject ot the design of manufacturer:-
(i) Dynamically balanced fly wheel. (ii) Air cleaner oil bath type (iii) Electronic Governor class 1 A with back up Mechanical governor class 1A Flywheel with starter ring (iv) Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level (v) Radiator cooling (vi) Radiator fan with guard (vii) Vaccum indicator (viii) Fuel filter and fuel houses (ix) Fuel injection pump (FIP) (x) Fan and water pump assesembly
(xi) Lub oil filter and pump (xii) Electric starting system with battery charging alternator and axial type started motor including adequate number of high capacity maint free lead acid bty as per manufacturer recommendation including inter connecting cables/leads with terminals complete with starting/stopping switch voltmeter, etc 01 set (xiii) Engine safety shut down system against low oil pressure and high water pressure (xiv) Exhaust gas driven turbo charge (xv) Oil filter (xvi) Lub oil cooler (xvii) Engine main manual with spare part list (xviii) Suitable designed acoustic enclosure as per CPCB regulations (xix) Any other item not included / specified but is a standard design of the manufacturer.
Engine instrument panel : Engine instrument panel shall comprising of the following:- (i) Starting on /off switch. (ii) water temp auge. (iii) Hour meter cum RPM indicator (iv) Lub oil pressure gauge (v) Lub oil temperature gauge (vi) Battery charging meter (vii) Safety alarm against high water temp and lub oil pressure. (viii) Any other item not included/specified but is a standard design of the manufacturer.
ALTERNATOR (Make: Kirloskar electric co/ Crompton/ Stemford) shall be self excited, self regulated, brush less for 20 KVA continous operation at the speed of 1500 RPM at 415 volts, 50Hz three phase, 4 wire system with advance electronic voltage regulator to ensure high voltage accuracy with +1% with class H insulation and SPDP enclosure directly coupled with engine through flexible couping and conforming to IS-4722 complete-01 No. Note:- Alternator should be able to deliver output rating at actual site condition.
Common fabricated base frame for engine and alternator made from structural channel, jerk proof PCC 1:2:4 mix type B1 foundation including adequate number of suitable anti-vibration pads all as per manufacture recommendations is deemed to be included in the unit rate quoted by the contractor.
Bottom mounted (or as per manufactures design) steel fuel tank fabricated out of 14 SWG MS sheet of capactiy not less than 12 hrs continous operation inside canopy with fuel level guage, drain plug locking arrangements etc with and including GI pipe connections duly laid as per engineering practice complete all as specifided and directed.
Bypass arrangement by providing separate panel made out of 3mm thick CRCA sheet, outdoor type with connecting copper bus bar of suitable size from change over and set of 3 Nos indication lamp for R, Y and B and 2 Nos 4 pole on load change over switch front handle operated of capacity 40 Amp is to be installed near AMF panel complete all as specified and directed. (i) Hour run meter. (ii) Any other item not included/ specified but is a standard design to the manufacturer.
AMF CONTROL PANEL: Supply, fabricating and testing of factory mounted cubical automatic main failure panel with degree of protection IP-42 conforming to IS-2147, suitable for 20 KVA capacity DG Set, fabricated using 14 Gauge CRCA sheet, powder coated comprising of suitable rated bus bar, internal wiring with control fuse, provn of connecting incoming and outgoing leads/ bus bar as approved with and including following accessories:-
(i) Master switch for auto/manual/reset/off-01 No. (ii) Ammeter digital type, 96X96 mm with CT's-03 Nos aux supply 230 vlts, AC, acuracyclass 1. (iii)Voltmeter digital type 96x96 mm to read 0-500 volts supply 230 volts, accuracy class 1.0. (iv) Digital frequency meter-01 No aux supply 230 volts, AC (v) Push button start, stop, reset-01 No. (vi) Set of lamp for indicating load a set, low pressure, high cylinder temperature, load on mains, set fails at start, low oil presure. (vi) Battery charger connected to load. (vii) Transformer of adequate rating. (viii) Ractifiers
(ix) DC ampere meter and voltmeter. (x) Fault accept / reset push button. (xi) Set of relays and contactor suitable for 20 KVA DG Set for automatic start and automatically shut down of suitable rating and capacity adjustable to 70 to 100% and 2 Nos MCCB 4 pole, 40 Amp,16 KA fixed on main supply and DG set supply. (xii) Make of AMF control panel shall be as per OEM recommendations.
Excavating in trenches (soft/loose/dense soil), n.exc. 1.5metre wide and n.exc. 1.5metre deep and getting out for foundation, laying of cable, erraction of poles, stay and pipe line complete all as specified and directed by Engineer-in-Charge.
Excavating in trenches (soft/loose/dense soil), n.exc. 1.5metre wide and exc 1.5mtr n.exc. 1.5metre deep and getting out for foundation, laying of cable, erraction of poles, stay and pipe line complete all as specified and directed by Engineer-in-Charge.
Removing surplus excavated soil to a distance n.exc 50 mtr and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge.
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed.
Supply and laying river sand coarse dry as in cushioning of underground cable in trenches, laid to a uniform thickness of 23 cm ( 8 cm under the cable and 15 cm over the cable) and gently punned down to 18 cm thickness complete all as specified & directed. Note:- Punned thickness shall be considered for measurement.
Supply and Laying in trenches for road/plinth and fixing alongwith pole/wall GI Tube 40 mm light grade for protection of cable complete all as specified and directed by Engineer-in-Charge.
M & L for boring holes (manually) under road, hard standing without damaging surface for 40 mm dia GI pipe etc complete all as specified and directed by Engineer-in-Charge.
Supply , laying, jointing and testing of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 Sqmm 4 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply , laying, jointing and testing of underground LT cable XLPE insulated ,screened PVC bedded , galvanised steel strip or wire armoured electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 Core laid in trenches/ducts/along poles/ through pipe under road etc all as specified and directed by Engr-in-Charge
Supply and fixing LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-in-Charge
Supply and fix steel tubular swaged poles type 410 SP-31 (9.0 meter long) complete with CI base plate, pole cap/ final taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld through out entire length of pole complete with including 2 coats of black bituminous paint externally upto planting depth and remaining portion of pole shall be provided with one coat of red oxide primer and two coate of aluminium paint complete all as specified and directed by Engineer-in-Charge.
M&L for plain Cement concrete in foundations, filling and mass concrete (1:4:8) Type D-2 using 40 mm graded broken stone aggregate complete all as specified and directed by Engineer-in-Charge.
M&L for plain Cement concrete in foundations, filling and mass concrete (1:3:6) Type C-2 using 40 mm graded broken stone aggregate complete all as specified and directed by Engineer-in-Charge.
M&L for PCC (1:2:4) Type B-1 using 20 mm graded stone aggregate as in coping incl necessary formwork complete all as specified and directed by Engineer-in-Charge.
Supply, installation, commissioning & testing of 16 meter height shaft in two section suitable to withstand 50 m/ Sec wind speed with raising & lowering system comprising head frame, luminaries carriage suitable to install 8 Nos luminaries in symmetrical arrangement double drum winch, 6 mm diameter stainless steel junction box, lightening arrestor spike, aviation obstruction light, (wiring material from JB to individual luminaries & MCB in base compartment are included and are a part of installation) with foundation bolts manufactured from special steel along with nuts, washer, anchor plate and common template with outdoor type stand mounted feeder pillar with 63 A TPN MCB incomer, digital time switch, 45 A TP contactors and raise/ lower push button, incoming 10 Sqmm and outgoing 2.5 Sqmm terminals including construction of shallow foundation as per OEM drawing recommended with M-20 grade concrete for the high mast considering the safe soil bearing capacity at site as 10 T/ Sqm at 2.0 Mtr depth with all material & labour including erection of the high mast with the help of suitable tools & Plants, wiring of luminaries with all wiring materials like PVC insulated PVC sheathed suitable core flexible cable of copper conductor of suitable size, lugs, MCB complete all as specified & directed. Make : PHILIPS/BAJAJ/CROMPTON as approved by GE.
Supply and fixing LED flood light 250 watt 230 V AC outdoor type, Aluminium Housing, Toughened Glass with Peanut Lens, Lumen Efficacy > 120Lm/w, O/P > 120Lm/watt, THD < 10%, PF > 0.95, CCT > 5700, Internal and External Surge Protection 5Kv/ 10Kv, Life Class- 50,000 with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete as per directed by Engr-in-charge.
Supply and fixing Timer panel board double door type consisting one MCB 40 A TP as incomer and digital type time switch 3P module, DIN 24 hours programmable every 1 minutes with 28 memory location of current capacity 32 Amps with one change over including connecting to existing power contactor complete.
Material and labour for three core 1.5 sqmm copper conductor cable for connecting up street/Flood/ secuirity light with pole junction box complete all as directed.
S&F bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.5 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps = 02 Nos with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete all as speciied and directed.
S&F Pole box three phase of size 205 x 255 x 112 mm with Polyamide gland, made out of IP65 (in accordnace with IEC 60529) Thermoplastic PS Junction Box with multi level knockouts for cable entries in different sizes for Loop in Loop Out (LILO) application with internally embedded gasket technology (Polyurethane). The junction box shall have fulfill the following standards IEC 60670-22 : Particular requirements for connecting boxes and enclosures. IEC 60695 – 2 – 11 :Glow Wire tested at minimum750 deg C., Halogen Silicon Free recyclable, fix to pole with suitable clamp comprising of terminal upto size 25 sq mm – 4 Nos. Provision for DP MCB 6 Amp 10 kA 240 volt – 1 No complete all as specified and directed.
Supply, fixing & connecting to electrical system & testing of Busbar panel board ,cubical type for out door use, made out of 3.15 mm thick CRCA sheet factory made, totally enclosed of size not less that 900mm x 600mm x 500mm and supported with 4 Nos MS Angle legs , duly painted with two coats of powder coated paint over one coat of red oxide primer effectively PVC gaket and sealed mounted on PCC blocks double door type with locking arragnedment with handle at front and openable at front & back both side with required hinges heavy duty, compartemtalised suitably including provision for tapping incoming & outgoing electric connections with suitable size of aluminium lugs glands and comprising of the following accessories :-
(a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of 250 amps rating (RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) MCCB 4 pole 415 Volts, 50 Hz, 100 amps rating, 25 KA breaking capacity, Ics=100% Icsas per IEC 60947-II, adjustable thermal setting - 01 No.(Incomming ) (c) Phase indication lamp, LED type(set of 3) -1 Set (d) Ammeter anolog type having measuring range (0-300) Amps with CTs etc including rotary switch to measure load of each phase : L&T/ Seimens (e) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (f) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete
(a) High conductivity aluminium busbar (Set of 4 strips), 4 Nos TPN of suitable for 400 Amps rating ,(RYB) for phase and 1 No for neutral mounted on DMC support with heat shrink sleeve-1 Set. (b) Phase indication lamp, LED type(set of 3) -1 Set (c) Ammeter anolog type having measuring range (0-500) Amps with CTs etc including rotary switch to measure load of each phase (d) Volt meter having measuring range (0-500) volt with rotary switch to measure voltage of phase R.Y.B (e) Grouting of panel including earth work as required PCC (1:3:6) type D-2 using 20 mm gradeded stone & plastering with (1:4 )cement sand etc complete. (f) INCOMMING: MCCB 4 Pole 250 Amp 415 volt thermal adjustable ,type with 36 KA breaking capacity & spreader both side as Incomming cotrol device : 01 Nos. (g) OUTGOING: MCCB 4 Pole 125 Amp 415 volt thermal adjustable ,type with 16 KA breaking capacity & spreader both side as outgoin cotrol device : 02 Nos. (h) MCCB 4 Pole 63 Amp 415 volt thermal adjustable ,type with 16 KA breaking capacity & spreader both side as outgoin cotrol device : 03 Nos.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade,40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection all as specified and testing on completion.
Earthing complete with galvanised steel earth plate electrode 600mmx600mmx6 mm thick buried directly in ground.(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to galvanised strip 32 X 6mm as earth lead by means of bolts, check nuts and washers of GI and earth wire protected by provision of GI pipe light grade,40mm bore including provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 KG/Sqm) and frame of angle iron 25 X 25 X 3mm with lugs 2 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge plate, common salt and charcoal filling, test point made out of phosphorous bronze with fixing arrangement, funnel, wire mesh and including earth work in hard/loose soil, returning filling in and removal of surplus soil to a distance not exeeding 50 mtr, all as per electrical plate No 3 of SSR 2009 Part-I and connection and testing complete on completion of work all as specified .
Supply & Fixing LED street light fitting 90 watt 230V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and errosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge.
M/s Vatsh Raj and co
M/S MALHOTRA ENGINEERING WORKS
ANKIT SHIP REPAIRERS AND SUPPLIERS
DKS ENGINEERING WORKS
Diamond Electric Co.
Titco Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .