Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | ₹1.3 Cr | L1 | Accepted-AOC LOWEST |
| 2 | L2₹1.4 Cr+₹10.8 L (8.46%)Rejected-Finance | ₹1.4 Cr+₹10.8 L (8.46%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹1.5 Cr+₹17.0 L (13.3%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | ₹1.5 Cr+₹17.0 L (13.3%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹1.5 Cr+₹24.2 L (18.9%)Rejected-Finance | ₹1.5 Cr+₹24.2 L (18.9%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹1.5 Cr+₹25.7 L (20.1%)Rejected-Finance | ₹1.5 Cr+₹25.7 L (20.1%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹1.8 Cr
EMD Value
₹2.6 L
Closing Date
30 Sept 2020, 6:00 pmClosed
CE R AND D SECUNDERABAD
CE R AND D SECUNDERABAD
PROVISION OF CIVIL WORKS FOR ELECTRICAL RIG FOR AIRCRAFT SYSTEMS ERAS PROJECT AT CABS BANGALORE
2020_MES_327389_1
CERD/BAN/TOKEN/54 OF 2019-2020
Open Tender
Civil Works
Item Rate
365 days
GE I R AND D EAST BENGALURU
CLASS B
CATEGORY a i AND REFER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹1,000
GE I R AND D EAST BENGALURU
₹2.6 L
Yes
20 Nov 2020
21 Feb 2020
6 Oct 2020
21 Feb 2020
30 Sept 2020
30 Jul 2020
21 Feb 2020 - 1 Mar 2020
Amount
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Brickwork with sub class ‘B’ bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed
Rendering 10mm thick in CM 1:6 on brick surfaces and finished even and smooth without using extra cement complete all as specified and directed.
Preparation of new plastered surfaces of walls and applying two coat of plastic emulsion paint over a coat of alkali resistant primer over two coats of internal grade wall care putty (total thickness not less than 1.50mm in two coats) complete all as specified and directed.
Complete removal of existing treatment from surfaces of walls by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc., and applying two coats of Plastic emulsion paint over a coat of primer and over two coats of internal grade wall care putty ( total thickness not less than 1.50mm in two coats ) finished even and smooth, complete all as specified and directed.
Complete removal of existing treatment from surfaces of ceiling by scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots with wire brushes and removing existing loose particles etc., and applying two coats of Plastic emulsion paint over a coat of primer and over two coats of internal grade wall care putty ( total thickness not less than 1.50mm in two coats ) finished even and smooth, complete all as specified and directed.
PCC 1:2:4 type B0, 30mm thick using 12.50mm graded stone aggregate as in flooring / paving finished rough to receive cement tiles complete all as specified and directed.
Screed bed for bedding layer of mortar of 15 mm thick for laying floor finishes in CM 1:4 complete all as specified and directed.
Double charged fully Vitrified tiles, light shade 10 mm thick of size 600mm x 600mm polished in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
Double charged fully Vitrified tiles, dark shade 10 mm thick of size 600mm x 600mm polished in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
All as per Sl item No. 9 here in before, but as in vertical sufaces, such as skirting and dados including rendering 10mm thick in CM 1:3 on brick walls as backing coat complete all as specified and directed.
PCC 1:5:10 type E-2, using 40 mm graded stone aggregate as in sub base complete all as specified and directed.
2mm thick epoxy resin based floor topping after priming the surface with solvent base epoxy resin primer designed for maximum absorption and adhesive as per manufraturers specification including prepartion of floor by wire brushing or light grit blasting to remove laitance, dust and cleaning the same to acheive machanical key between the floor and coating system and applying epoxy putty mixed with suitable fillers to cover the worn out areas all as specified and directed. Note: (a) Floor topping shall be Nitofloor SL 2000 of M/s FOSROC / MASTERTOP TM 1215 PLUS of BASF or equivalent in CIPY. (b) Primer shall be Nitoprime 25 of M/s FOSROC or equivalent in BASF / CIPY. (c) Epoxy putty shall be Nitofloor FC 140/150 of M/s FOSROC or equivalent in BASF / CIPY.
Supply and fixing of ceiling system with fine figured edge tiles having humidity resistance (RH) of 95&. NRC 0.34 light reflectance approx 84& thermal conductivity K-0.052 – 0.057. W/mk colour white fire performance of class-1 as per BS 476 part 6 & 7 in module size of 600 x 600 x 16 mm thick suitable for green building application with recycled content of 38-41% with Armstrong or equivalent silhouette profile exposed grid system with 15mm white flanges incorporating 6 mm central reveal in white/black colour. Silhouette, main runners & cross test to have mitred ends & birds mouth notches to provide mitred cruciform junctions. The Tee sections have a galvanizing of 170 hrs per sqm & passed through 500 hrs of salt test. The main runner spaced at 1200 mm c/c should be securely fixed to the structural soffit using suspension system at 1200 mm maximum c/c. The first / last suspension system at the end of each main runner should be greater than 450 mm from adjacent wall. Cross Tee 1200 mm long should be interlocked between main runners at 600 mm module. 600 x 600 mm module is fortned by fitting 600 mm long flush fitting cross Tee, perimeter trim consist of wall angles of size 3000 x 19 x 19 mm secured to wall screws at 450 mm c/c.complete all as specified and directed. Make: Arm strong / Saint Gobain
Aluminium powder coated frame for partition, doors, windows, ventilators including hinges and handle with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
12 mm thick pre-laminated particle board exterior grade pre-laminated on both sides fixing to aluminum frame complete all as specified and directed.
Sheet glass ordinary quality for 5.50 mm thick fixing in aluminum frame with suitable rubber gasket and glazing with oil putty exc 0.50 sqm in each pane complete all as specified and directed.
Preparation of steel surfaces of any description, not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Solar control film 50 micron thick reflective type (gareware sun control or equivalent) sticked to glass panes as per instructions of manufacturers complete all as specified and directed.
Venetian blinds verical type 100 mm width with approved fabric and powder coated aluminum fittings such as top rails metal weight nylon button loops etc to match with the top rail metal base complete all as specified including taking down old one complete all as specified and directed.
Aluminium die cast body door closer hydraulically regulated, degination No. 3 universal type suitable for door shutters of 851 to 1000 mm in width and of weight 61 to 80 Kg complete all as specified and directed.
Mortice lock brass vertical type 4 lever size 100 mm complete all as specified and directed.
Aluminum anodised floor door stoper for aluminum alloy body and tongue anodised with hard drawn steel spring fixed in floor 150 mm long complete all as specified and directed.
Sheet glass ordinary quality for 4 mm thick and glazing n.exc 0.5sqm in each pane complete all as specified and directed.
125 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
Extruded aluminium alloy handles, fabricated type, anodized 125 mm complete all as specified and directed.
Design mix concrete M-30 (12.5 mm graded stone aggregate) 30 mm thick as in levelling course on RCC floor and brushing neat cement slurry with 3.0 kg of cement per sqm using WPC as per manufactures instructions including necessary formwork complete all as specified and directed. Note: WPC shall be measured and paid separately.
RCC design mix concrete M-30 in flooring, foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
Mild steel TMT bars for reinforcement 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for column, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Formwork to edges of concrete flats, breaks in floors, openings concrete walls, floors and roofs and sides of RCC / PCC bands in walls, horizontal or sloping and similar work all exceeding 20cm wide complete all as specified and directed.
Expansion joint 20mm thick and 20mm width filled with preformed bituminous filler, applying bond breaker tape on top of filler board for complete width of joint, provision of polystyrene backup rod 20mm dia, filled with polyurethane sealant (minimum depth of sealant above backup rod shall be 20mm) complies with BS-5212, priming the side and applying masking tape on edges of joint to prevent accidental spillage of sealant and removing the masking tape after sealant applied for thickness of concrete slab 225 mm all as specified and as directed by Engineer-in-Charge.
Taking down shutters (of any description) n.exc 1.5 Sqm each complete all as specified and directed.
2nd class hard wood, plain, solid, straight chowkats and frames wrought framed rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
30 mm thick flush shutter solid core construction with partical board core and ply wood face panels commercial type on both sides and both the faces are covered with decorative face veneer with lipping / frame to match, (bonding shall be with formaldehyde glue to ensure stringer bonding and longer life of door) complete all as specified and directed.
Preparation of old wooden surfaces of any description, not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Butt hinges, medium weight cold rolled mild steel, 125mm size complete all as specified and directed.
150 mm long aluminium anodized barrel tower bolts of extruded section complete all as specified and directed.
Extruded aluminium alloy handles, fabricated type, anodized 150 mm size complete all as specified and directed.
200mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, extruded sections and fixing bolts and sliding bolts of extruded sections and fixed complete all as specified and directed.
Excavating in trenches, n exc 1.5m wide and n.exc 1.5m in depth for foundation etc etc n.exc 10 sqm on plan and n exc 1.5m in depth and getting out in hard / dense soil complete all as specified and directed.
Excavation over areas not exc 1.5 mtr in depth for foundation and getting out in soft / loose soil complete all as specified and directed.
Removing of demolished / excavated materials to a distance exc. 5 KM, but n.exc 10.0KM and depositing out side MD land complete all as specified and directed (material obtained from Sl item No. 1, 40 & 41).
PCC 1:2:4 type B0 (using 12.5 mm graded crushed stone aggregate) as in coping / benching / bed to drain including necessary form work and finishing complete all as specified and directed.
Demolition of reinforcement cement concrete in any description and in any position not otherwise specifically provided, (reinforcement cut as required to facilitate demolition) below or above ground level complete all as specified and directed.
MS Plates Fe-410 (Gd E 250 quality 'A' (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
Mild steel screw bolts 16 to 20 mm dia neck (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed.
Form work to sides of rough finished surfaces of flat concrete foundations, footings bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter complete all as specified and directed.
Form work to edge of concete flat treads breaks in floor concrete wall such as roof, floor, landings and similar work; exc. 10 cm but not exceeding 20cm thick for rough finished surfaces complete all as specified and directed.
MS frame work as in cable trench of angles or other section fixing of trench cover plates complete drilled and fixing including welding where required as directd by Engineer-in-Charge.
Rotational moulded HDPE water storage tanks (cylindrical vertical with closed top), double layered; 1000 Ltr capacity hoisted and fixed in position complete all as specified and directed.
S&F, CPVC pipe 40mm dia single socket, in any length with rubber ring joints, laid in trenches or in floors complete fittings complete all as specified and directed.
PP-R gate valve 40mm dia complete all as specified and directed.
100mm wide yellow marking reflective tape for floor marking complete all as specified and directed.
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
Taking down copper / aluminium point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping a side and making good disturbed surfaces of walls, floors, etc all as specified and directed.
Point wiring complete with multi stranded copper conductor size 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade conforming to IS 694 multistranded, drawn in and including rigid PVC concealed conduit / casing capping on walls / floors / ceiling etcwith and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches, regulator and also including 1.5 sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly, cutting chasis to the walls / floors / ceiling and making good to match with existing surfaces, complete all as specified and directed for one light / fan point controlled by one switch. Note: wherever point wiring is to be provided over concrete surface like ceiing / columns / beams etc the point wiring shall be provided in casing and capping on surface.
All as per Sl item No. 56 here-in-before, but using copper conductor 4 sqmm, PVC insulated unsheathed FRLS cable with copper conductor size 4 sqmm PVC insulated unsheathed continuous earth continuity for 5 pin 6/16 amps socket outlet independently.
Modular switch one way 6 Amps one module complete all as specified and directed.
Socket 6A - 2/3 pin combined 2 module, modular type complete all as specified and directed.
Fan step regulator, 120W - 2 module, modular type complete all as specified and directed.
Switch 16 Amps, modular type complete all as specified and directed.
Socket 6A/16A-5 pin combined 2 module, modular type complete all as specified and directed.
Wall mounting fan 450MM Hi-speed for test rig area complete all as specified and directed.
Ceiling rose surface backelite two to three terminal complete all as specified and directed.
Industrial panel mounted plug socket 3 pin, 3P+N+E suitable for 415V lP44 32 Amp rating, complete all as specified and directed.
Recess mounted full panel LED luminaire 36 watt fitting 2' x2' with white powder coated housing & frame in CRCA sheet, High efficiency LED grade diffuser, electronic driver duly wired upto terminal block, CRI>80, LED Colour temperature-5700K, IP20, 50000 burning hours as per L70 Criteria, Ambient temperature-0 to 50 DegC, Driver Efficiency>85%, THD<10%, Powerfactor>0.95, Surge protection in CM-3KV, Multistage isolated Constant current-Constant voltage operated driver with range 150-270V AC and Safety extra low voltage safe level<60V DC as per IEC Standard. Make: Havells Cat Part No. VENUSNEOHE2X2PLR18-42WLED830MOD. Driver: LEDDRIVER36V36WS or Techno Commercially equivalent in Philips / Crompton Greaves.
Suspended type LED luminaire 20 watt fitting 4' long with white powder coated housing & frame in CRCA sheet, High efficiency LED grade diffuser, electronic driver duly wired upto terminal block, CRI>80, LED Colour temperature-5700K, IP20, 50000 burning hours as per L70 Criteria, Ambient temperature-0 to 50 DegC, Driver Efficiency>85%, THD<10%, Powerfactor>0.95, Surge protection in CM-3KV, Multistage isolated Constant current-Constant voltage operated driver with range 150-270V AC and safety extra low voltage safe level<60V DC as per IEC Standard including suspension system. Make: Havells Cat Part No.CONSTA544LP20WLED830SPMMAWH or or Techno Commercially equivalent in Philips / Crompton Greaves.
LT UG XLPE Cable PVC insulated armoured heavy duty electric cable with aluminum conductor 1100 volt grade cable size 16 x 4 sqmm cross section area in trenches / floor / concealed on walls connecting with suitable aluminum lugs and making surface good complete all as specified and directed.
MCBs distribution board of sheet metal enclosure factory made double door powder coated single pole and neutral with 200 amps rated bus bar 8 way 240 Volts, complete all as specified and directed.
MCBs distribution board of sheet metal enclosure factory made double door powder coated Triple pole and neutral with 200 amps rated bus bar 4 way 415 Volt complete all as specified and directed.
MCCB 3 pole, 415 V Adjustable type 100 Amps with breaking capacity 16 KA complete all as specified and directed.
MCCB 3 pole, 415 V Adjustable type 125 Amps with breaking capacity 16 KA complete all as specified and directed.
MCB tripple pole 'C' Curve three pole, 415 V complete all as specified and directed for 40 Amps capacity.
MCB tripple pole 'C' Curve three pole, 415 V complete all as specified and directed for 63 Amps capacity.
MCB SP 20 Amps 'C' Curve Amps capacity 230 volt including connections complete all as specified and directed.
MCB SP 6 Amp 'C' Curve Amps capacity 230 volt including connections complete all as specified and directed.
Metal clad SPN enclosure with a two pin and earth plug, socket complete with one single pole MCB 20 Amps complete all as specified and directed.
Sub main wiring complete with 2 runs of 6 Sqmm PVC Insulated and unsheathed cable with multistranded, FRLS grade copper conductor ISI marked and drawn through and including concealed 20mm dia PVC medium grade non metallic rigid conduit and conduit accessories fixed on walls / floors / ceilings etc and connecting terminal ends including 6 Sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: Two runs of 6.0 Sqmm copper cable, one run of earth wire of 6.0 Sqmm copper cable and 20mm dia PVC conduit shall be measured and paid as one RM.
Sub main wiring complete with 4 runs of 10 Sqmm PVC insulated and unsheathed cable with multistranded, FRLS grade copper conductor ISI marked and drawn through and including concealed 25mm dia PVC medium grade non metallic rigid conduit and conduit accessories fixed on walls / floors / ceilings etc and connecting terminal ends including 2x10 Sqmm PVC insulated unsheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly complete all as specified and directed. Note: Four runs of 10 Sqmm copper cable, two runs 10 Sqmm earth wire and 25mm dia PVC conduit shall be measured and paid as one RM.
Sub main wiring complete with 4 runs of 6 Sqmm PVC insulated and unsheathed cable with multistranded, FRLS grade copper conductor confirming to IS-649, 1100 volts grade with colour code and drawn through and including 25mm dia PVC non metallic rigid conduits and conduit accessories run on surface of wall / floors / ceiling etc and connecting terminal ends including 2x 6 Sqmm PVC insulated unsheathed copper conductor cable green colour as continuous earth continuity conductor and connecting to earth complete all as directed and specified. Note: Four runs of 6.0 Sqmm copper cable, two run of earth wire of 6.0 Sqmm copper cable and 25mm dia PVC conduit shall be measured and paid as one RM.
Taking down ceiling fan single phase 240v, 1200 mm sweep from the existing position including disconnecting supply cable from celing rose / connector opening ceiling fan carefully and taking out worn out / defective spare parts such as bearing, bush, shaft blades, condensers, rubber reel, bolts and nuts etc, cleaning thoroughly with necessary lubricants and reassembling of celing fan, with new down rod with 2.5 to 3 feet long and fixed in position after completion of false ceiling work, connecting and testing complete all as directed.
Modular telephone socket RJ 11 (jack type) one module with conduit pipe cutting chases to the walls / floors / ceiling and making good disturbed surfaces to match the existing surfaces, complete all as specified and directed
LAN cable socket RJ 45 UTP information outlet tool less 2 module type complete with conduit pipe cutting chasis to the walls / floors / ceiling and making good disturbed surfaces to match the existing surfaces complete all as specified and directed.
Cover plate with frame for telephone socket RJ 11 (jac type) 1 module with metal flush boxes of suitable size complete all as specified and directed.
Cover plate with frame for lan cable socket RJ 11 (jac type) 2 module with metal flush boxes of suitable size complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode 600 x 600 x 6mm as earthing lead buried directly in ground vertically to depth not less than 2.25 mtr below GL with the top edge of the plate not less than 1.5 mtr from GL, connected to GI earth lead of 4.0mm dia, by means of bolts & nuts, to GI and connected to earthing test point all as shown in elecrical plate No. 3 of SSR Part-I of 2009* specified or indicated and testing on completion including excavation / earth work in any type of starta, PCC (1:3:6) type C1 earthing chamber pre cast slab 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric (XPM) weight not less than 4 KG/sqm cast iron frame, funnel with wire mesh GI watering pipe of 20 mm bore medium grade and lugs with and including GI earth wire 4 mm dia with GI protection pipe of 15 mm medium grade 7.5 meter long etc complete tested on completion all as specified and directed. NOTE: Earth resistance not exceeding 1.0 ohm.
Supply, installing, testing and commissioning of air break gang operated triple pole switch out door, vertical mounting type of capacity 800 Amps, mechanically operated mounted on insulator on and steel frame with operating mechanism worked from ground level complete with locking arrangement including 65mm pad locks with two keys Make Godrej / Freedom) complete with fuse mounts, fuse carriers and HT fuse carriers and HT fuse element having suitable rating at 11 KV and insulator suitable for 11 KV, HT AC 50 C/S and mounted on HT 11 metre poles including 9 insulators and necessary connections complete all as specified and directed.
Replacement of Drop out fuse assembly expulsion type 11 KV above 50 Amps and upto 100 Amps capacity fixed in position complete all as specified and directed.
Pin type porcelain vitreous brown, insulator 150mm height and 150mm dia for 11000 volts grade grade including one galvanised mild steel spindel, two galvanised iron washers and one galvanised iron nut complete all as specified and directed.
Replacement of lightening arrester metal oxide type complete with all fittings, transmission class, discharge capacity 65 kilo amp suitable for 11000 Volts with replacing old lighting arrester in HT complete all as specified and directed.
Aluminium conductor steel reinforced for bus connection and in jumpers for tapping replacing unservicable conductors in four pole structure all as directed.
S&F, Alkaline pipe of 20 mm dia 2 mm thick fixed over ACSR conductors / jumpers etc complete all as specified and directed.
Supply, installing, testing and commissioning outdoor type step down transformer, 11 KV/433 Volts (at full load) AC 3 phase 50 Hz, 1000 KVA capacity, core type, double copper wounded, oil immersed, naturally cooled, oil natural - Air Natural (ON AN) with external cooling tubes, delta connected on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYn-11 with Neutral brought out on secondary side (LV side) and having tapings at + 7.5% (in three steps) on LV side to be changed by means of hand operated off load tap changer gear including initial filling of transformer oil having dielectric strength not less than 60KV. The transformer shall be IS-2026 marked and shall comprise of the following: - (a) Three Nos porcelain bushing suitable for 11 KV on HV side, complete with copper rods, nuts and washers including the cable box. (b) One cable box on LT side (Secondary side) consisting of four Nos porcelain bushing with copper rods complete. (c) Oil conservator with filter type drain valve and oil level guage. (d) De-hydrating breather with first fill of dehydrating agent (silica gel). (e) Bucholz Relay. (f) Expolsive vent, Thermometer pocket on tank cover, Oil level gauge, oil drain filter valve, lifting lugs, oil filling hole with cap / plug with connection plate complete, air release valve plug and four Nos plain solid steel detachable rollers. (g) One No 100mm dia, dial type thermometer, vapour metal guard having range 0-120 degree celsius with metal guard having maximum permissible temperature reading indicator with re-setting device. (h) Two earthing terminals on tank cover to facilitate fixing of 32 x 6mm galvanised iron earth strip for earthing of body. (j) Rating plate and terminal marking plate. (k) Extra bushing for neutral, in the LT cable box for providing independent set of earthing for neutral.
Cable jointing kit for 11 KV grade (Earthed Grade) cable for in door termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminum conductor cable of size 120 to 185 sqmm complete all as specified and directed.
Cable jointing kit for 11 KV grade (Earthed Grade) cable for out door termination, cold shrink type, joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, aluminum conductor cable of size 120 to 185 sqmm complete all as specified and directed.
Supply, installation, testing & commissioning of 11 KV Outdoor type 03 way RMU extensible IP54 floor mounted with internal copper bus bars, consisting of Load break switch-01 nos as incomer and fixed type Motorised Vacuum Circuit Breakers-02 Nos. as outgoing along with air insulated metering module. All live parts, bus bars of RMU should be enclosed in tank to avoid multiple interconnections & sealed for life robotically for three sides and one side manual welded non magnetic / non ferrite / stainless steel tank Grade 304 of minimum 2 mm thick having IP67 degree of protection filled with SF6 gas to fulfill the requirement as per IEC 60376 & 603760 B as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. The unit shall have front cable entry for ease of installation. RMU should complete with all accessories such as terminal boots, VPIS, cable supports, all front cable terminations, mechanical indications ON/OFF, Manometer as per with IEC standards 62271-200, 60056, 60129, 60265, 60298, 60420, 60529 and 60694. Altitude of installation upto 1000m as per IEC 60120. Bushings bolted type as per OEM design.The unit shall include the following with all necessary standard fitting required at site. RMU should be tested for an internal arc fault of 21kA for 1 sec. for tank holding the HV components and cable box and paint shade and thickness should be as per AIS 632 IS-5. 630A Load Break Switch module for making of fault current Earth Swicth of full making capacity-1 No as in coming Short time withstand current - 21KA / 3 sec Making Capacity - 52.5KA Auxiliary contacts - 1No + 1NC Power frequency withstand voltage - 38KV Impulse withstand voltage - 95KV
Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X Cable covers - 3X Snap action mechanism for manual operation Cable box for front termination of the cable suitable 11 KV XLPE cable Right angle boots (push on type) Suitable Cable bushings for front only cable terminations Arc proof cable covers with self Interlocking mechanism with earth switch 630A VCB module for making & breaking of fault current alongwith Earth Switch of full making capacity as Outgoing-2 Nos. Vacuum circuit breaker shall be having spring charged stored mechanism suitable for motorized operation-24VDC. Opening & Closing coils - 24VDC. Three position disconnector / earthing switch downstream vacuum circuit-breaker. Three position single spring mechanism for disconnector / earthing switch. “Live Cable” LED Indicators through Capacitor Voltage Dividers mounted on the bushings. Short time breaking current - 21KA/ 3 sec. Making Capacity - 52.5KA. Auxiliary contacts - 6NO + 6NC. Power frequency withstand voltage - 38KV. Impulse withstand voltage - 95KV Nominal operating gas pressure - 1.4 Bar abs. Front cover mechanism - IP2X. Cable covers - 3X. Green (ON) / Red (OFF) push buttons to operate the VCB. 3O/C + 1E/F self powered numerical protection relay with Low and High set for Over current and Earth Fault. RMU tank shall be tested for an internal arc fault of 21KA for 1 sec No of electrical operating cycles shall be 2000 cycles and short circuit cycles shall be 50 Resin cast ring core protection CT on cables 100-50/1, 5P10, 2.5 VA - 2 Nos. Resin cast ring core Metering CT on cables 100/1 A, Cl-1.0, 2.5 VA - 2 Nos. Mechanical ON / OFF / EARTH / Spring charge Indication. Cable boxes should be Arc Proof interlocked with respective Earthing Switches.
Bus Connected Air Insulated Metering Module consisting of following: three Phase PTs - 11kV/V3/110/V3, Cl-1.0, 50VA-1 no. Space Heater with thermostat, Terminal Blocks, for outgoing VCBs digital multifunctional meters, Cl-1.0,50VA of including inbuilt battery along with battery charger and maintenance free batteries of capacity not less than 20 AH to give backup upto 05 hours with 10 open / close operations. Auxiliary relays for OTI, WTI, Bucholz-Alarm & Trip for 2 Nos. outgoing VCB module 4 x Lockout relays (86) / Transformer digital card for all VCBs, Dummy module for accomodating the necessary Auxiliaries, if required. Note: The Auxiliary supply required (230V AC PT) shall be an integral feature in the RMU. Make of RMU: ABB / Schneider / Siemens.
Supply, laying, jointing, testing and commissioning of 11KV XLPE HT UG cable of size 3 core 185 Sqmm insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade (earthed) ISI marked, IS: 7098 Part-II, triple extruded and with dry nitrogen curing with stranded aluminium conductor laid in trench, in pipe, in duct, on wall complete all as specified and directed.
XLPE LT PVC insulated, armoured, heavy duty electric cable size of 630 Sqmm 3.5 core with aluminum conductor, 1100 Volts grade, ISI Marked, IS:7098 (Pt I) in trenches / fixed on wall complete all specified and directed.
Excavating in trenches not exceeding 1.5Mtr wide and not exceeding 1.5M depth in foundation etc and getting out in soft / loose soil complete all as specified and directed.
Returning and filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick with soils complete all as specified and directed.
Removing excavated soils not exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5M above the starting point complete all as specified and directed.
Supply and spread dry river sand / M-sand in trenches for cable cushioning all as specified on both top and bottom of cable including ramming complete all as specified and directed. Note: For the purpose of payment the punned thickness will be measured.
Un-reinforced pre cast concrete covers class LV type 250 x 150 x 40 size factory made for cable protection complete all as specified and directed.
GI tube 'light grade' with all fittings and fixtures 80 mm dia for protection of cables complete all as specified and directed.
GI tube 'light grade' with all fittings and fixtures 150 mm dia for protection of cables complete all as specified and directed.
Earthing complete with Copper plate electrode 60 x 60 cm x 3mm thick and 20 x 3 mm Copper strip as earthing lead burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with the top edge of the plate at a depth not less than 1.5 mtr from below normal GL, connected to and including Copper strip 20x3 mm as earthing lead by means of nuts, bolts, washers, checknuts of copper and connected to earthing test point all as shown in electric plate No. 3 of SSR Part l of 2009 and as specified or indicated and testing on completion including excavation / earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (Reinforced with welded steel wire fabric (XPM)) weight not less than 4 Kg/sqm,cast iron frame, funnel with wire mesh, including copper earthstrip with GI protection pipe of 40mm medium grade 7.5 meter long etc complete and testing on completion all as specified and directed. Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. Copper strip above 7.5m will be measured and paid seperately. 3. Earth resistance not exceeding 1.0 ohm.
Earthing complete with galvanised iron plate electrode 600 x 600 x 6.00mm thick GI earthing lead burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with the top edge of the plate at a depth not less than 1.5 mtr from below normal GL, connected to and including Galvanised iron strip 32x6 mm as earthing lead by means of nuts, bolts, washers, checknuts of galvanised iron and connected to earthing test point all as shown in electric plate No. 3 of SSR Part l of 2010 and as specified or indicated and testing on completion including excavation / earth work in any type of strat PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement cioncreat (1:2:4) type B1 (Reinforced with welded steel wire fabric (XPM)) weight not less than 4 Kg/sqm,cast iron frame, funnel with wire mesh, including GI earth strip with GI protection pipe of 40mm medium grade 7.5 meter long etc complete and testing on completion all as specified and directed. Note: 1. Rate quoted shall deemed to include cost of excavation in any type of strata, RFR and removal upto 50metre, PCC pit, funnel and RCC cover plate. 2. GI strip above 7.5m will be measured and paid seperately. 3. Earth resistance not exceeding 1.0 ohm.
Gl Earth strip 32 mm x 6 mm fixed on porcelain insulator fixed on wall using cadmium plated screw or laid in trenches complete all as specified and directed.
Copper Earth strip 20 mm x 3 mm fixed on porcelain insulator fixed on wall using cadmium plated screw or laid in trenches complete all as specified and directed.
Design, fabricate, supply, install, test & commissioning of factory made floor mounted LT cubical panel board indoor type conforming to IS / IEC-61439-1&2:2011 with canopy, louvers & shutters made out of 3.0 mm thick CRCA sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opening and locking arrangement 415Volts, 3 phase, 50 Hz having copper bus bar of capacity 2500 Amps TPN duly colour coded and for neutral supported with DMC / SMC insulators colour coded with heat shrinkable sleeve having short circuit current with minimum 85 KA for one second and suitable for internal connection including instaneous over load and earth fault relays complete with digital type volt meter 0-500Volts, ammeter 0-2500 Amps including suitable range of CT's of metering, duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in PCC 1:2:4 type B1, MS channels, nut, bolts, washers etc including control and consists of following accessories. INCOMMER: (a) LT ACB 415 Volts 3 Phase 4 Wire 50 Hz cubical / truck type complete with air circuit breaker, power load protection, No - Volt realese with necessary CTs Meter cable boxes, rating 1600 Amps (Manual drawnout Type, Incomming) 1 No (b) LT ACB 415 Volts 3 Phase 4 Wire 50 Hz cubical / truck type complete with air circuit breaker, power load protection, No - Volt release with necessary CTs Meter cable boxes, rating 1000 Amps (Manual drawnout Type, Incomming) 1 No for APFC panel. (c) MCB 3 Amps - 01 No, 230 V10 kA for auxiliary supply (01 No). (d) Panel mounted type digital multifunctional energy meter A, V, Z, KW, PF, CT operated, LT 3 phase, 4 wire, including ct ratio 400/5 - 01 No.
OUT GOING: (a) MCCB 4 pole 415V, 800 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 50 KA, adjustable overload min 70-100% - 2 Nos. (b) MCCB 4 pole 415V, 315 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 36 KA, adjustable overload min 70-100% - 03 Nos. (c) MCCB 4 pole 415V, 350 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 36 KA, adjustable overload min 70-100% - 02 Nos. (d) MCCB 4 pole 415V, 160 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 25 KA, adjustable overload min 70-100% - 01 No. (e) MCCB 4 pole 415V, 100 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 16 KA, adjustable overload min 70-100% - 01 No. (f) MCCB 4 pole 415V, 400 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 36 KA, adjustable overload min 70-100% - 01 No. (g) MCCB 4 pole 415V, 125 Amps, 50 Hz with thermal magnetic release and Ics=100% Icu with rupturing capacity 16 KA, adjustable overload min 70-100% - 02 No. (h) LED Indicating lamps set RYB - 01 set.
Supply and install, hi wall mounted split type AC Units indoor / out door complete with cordless remote control unit and with minimum 5 star rating and EER 3.2 of capacity as shown 220 volt - 240 volt 50 Hz of capacity 2 TR complete all as specified and directed.
Supply and install, hi wall mounted split type AC Units indoor / out door complete with cordless remote control unit and with minimum 4 star rating and EER 3.2 of capacity as shown 220 volt - 240 volt 50 Hz of capacity 1.5 TR complete all as specified and directed.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with out put voltage stabilized at 230 volts with accuracy of + 2.5% and of capacity 5 KVA complete all as specified and directed.
Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 volts to 250 volts with out put voltage stabilized at 230 volts with accuracy of + 2.5% and of capacity 4 KVA complete all as specified and directed.
Copper tubing 24 SWG 5/8 inches dia of superior quality suitable for refrigeration suction / discharge line along with tubular rubber insulation suitable for air conditioners complete all as specified and directed.
Copper tubing 24 SWG 3/8 inches dia of superior quality suitable for refrigeration suction / discharge line along with tubular rubber insulation suitable for air conditioners complete all as specified and directed.
Supply and charging of refrigerent gas 410A / 407C complete all as specified and directed.
Making opening / drilling of size 65 mm dia, using heavy duty stone driller / cutter machine in the stone machinry wall for installing spilit type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc and making good the disturbed surface complete all as specified and directed.
MS stand duly painted suitable for fixing 2/1.5 TR AC out door unit and fixed complete all as specified and directed.
Vinayaka Enterprises
devan enterprises
C R R CONSTRUCTIONS
SREE BUILDERS
K T ASSOCIATES
RAMYA CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .