Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.6 CrAdmitted-Finance R 1 BEHIND MOTOR AIDS PETROL PUMP SWARG SHASTRI NAGAR JHOTWARA ROAD VILLAGE TOWN JAIPUR CITY JAIPUR JAIPUR RAJASTHAN 302016 INDIA | JAIPUR | RAJASTHAN | 302016 | ₹7.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹8.0 Cr+₹38.5 L (5.07%)Admitted-Finance B 437 438 ROAD NO 18A KALADWAS BHAMASHAH INDUSTRIAL AREA UDAIPUR RAJASTHAN 313001 | UDAIPUR | RAJASTHAN | 313001 | ₹8.0 Cr+₹38.5 L (5.07%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Pyrotech Workspace Solutions Pvt. Ltd. L2 | Eminent Colonizers Private Limited L1 |
|---|---|---|---|---|---|
| 1.00 | Interior Work | - | - | - | - |
| 2.00 | SITC of Acoustic Metal Paneling
1) Factory-made removable type self-inter-lockable metal panels with a front sheet of preformed textured hot-dip galvanized sheet with rigid polyvinylchloride (PVC) film on one side and on the other side a coating to avoid rust (sheet thickness 0.6mm & PVC Coating at least 0.11mm). The back cover of the panel shall be made up of a 0.6mm thick CRCA/GI sheet of approved colour. The panelling design shall comprise of a specially designed combination of perforated and non-perforated panels through CNC laser cutting, bending & punching. The panelling/partition shall be Greenguard gold certified from UL / Intertek / NABL / reputed test laboratory. The necessary certificate / test report valid on the bid date and to be submitted along with the technical bid. Panels shall be designed to achieve shape and design as per the design consultant and shall be fixed using GI/CRCA hook fitting on the structure. Overall system thickness for panelling shall be 60mm to 90mm and for partition shall be 70mm to 120mm.
2) Tiles Perforation – To achieve acoustics without deteriorating the aesthetical appeal of the office interior it is necessary that the at-least twenty-five per cent of the wall panelling tiles have micro-perforations (less than 1.6mm dia. each) all over the surface with a density of 5000 holes per square feet. This feature shall be audit certified (from UL/Intertek/NABL/ reputed test laboratory) on modular wall panelling tile to have clean perforations and provide a smooth finish on the front fascia of tiles. The tile shall have 5000 holes per square foot on the front side of the tile.
3) To provide an acoustically superior environment and ensure proper attenuation of airborne sound, it is necessary that the sound transmission class (STC) value of wall panelling and the partition should be 35 (According to IS: 9901 (Part III) – 1981, DIN 52210 Part IV- 1984, ISO: 140(Part III) -1995, as per the test report from UL / Intertek / NABL/ reputed test laboratory.
4) Seismic safety of users & equipment is a prime concern area. The metal panelling/partition must sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations. The test must be carried out by an authorized agency i.e., from UL / Intertek / NABL / reputed test laboratory. 5) The wall panelling should be robust & strong enough to sustain the routine loads/minor impacts of a typical office environment. The wall panelling/partition structure shall have audit certified design feature (from UL / Intertek / NABL/ reputed test laboratory) of Load-bearing capacity of 300 Kgs to hold any display unit on clamp having a minimum length of 750mm.
6) Audit certified design feature (from UL / Intertek / NABL/ reputed test laboratory) of modular wall panelling tile having secure locking arrangement for equidistant mounting. Locking arrangement enables easy replacement without using any tool within 20 seconds. The feature shall provide easy flexibility of locking all tiles in one column through gravity. The necessary certificate / test report valid on the bid date and to be submitted along with the technical bid.
7) The modular metal panelling must comply to the lead-free directive to ensure the restriction of hazardous substances so that the final product does not contaminate the environment. The final product i.e., modular metal panelling does not contain hazardous substances and we give a healthy life to our coming generations it is necessary that the modular metal panelling system shall be RoHS certified (from UL / Intertek / NABL / reputed test laboratory).
8) From a fire safety point of view, the metal wall panelling tiles shall be class A fire rated as per the norms of comparative measurements of surface flame spread and smoke density measurements with that of select grade red oak and fibre-cement board surfaces under the specific fire exposure conditions. The proposed wall panelling tiles shall be Class A certified as per ASTM e84 (from UL / Intertek / NABL / reputed test laboratory) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP. | 815 | Sq. Mtr. | 18,699.2 ₹1,79,83,023.9 | 17,980 ₹1,72,91,366 Lowest |
| 3.00 | SITC of Acoustic Metal Partition
1) The material of construction and technical specification shall remain the same as per acoustic metal panelling (Sr No. 1 acoustic metal panelling) however in partition the cladding shall be done on both sides of the section/grid work.
2) Factory-made removable type self-inter-lockable metal panels with a front sheet of preformed textured hot-dip galvanized sheet with rigid polyvinylchloride (PVC) film on one side and on the other side a coating to avoid rust (sheet thickness 0.6mm & PVC Coating at least 0.11mm). The back cover of the panel shall be made up of a 0.6mm thick CRCA/GI sheet of approved colour. The panelling design shall comprise of a specially designed combination of perforated and non-perforated panels through CNC laser cutting, bending & punching. The panelling/partition shall be Greenguard gold certified from UL / Intertek / NABL / reputed test laboratory. The necessary certificate / test report valid on the bid date and to be submitted along with the technical bid. Panels shall be designed to achieve shape and design as per the design consultant and shall be fixed using GI/CRCA hook fitting on the structure. Overall system thickness for panelling shall be 60mm to 90mm and for partition shall be 70mm to 120mm.
3) Tiles Perforation – To achieve acoustics without deteriorating the aesthetical appeal of the office interior it is necessary that the at-least twenty-five per cent of the wall panelling tiles have micro-perforations (less than 1.6mm dia. each) all over the surface with a density of 5000 holes per square feet. This feature shall be audit certified (from UL/Intertek/NABL/ reputed test laboratory) on modular wall panelling tile to have clean perforations and provide a smooth finish on the front fascia of tiles. The tile shall have 5000 holes per square foot on the front side of the tile.
4) To provide an acoustically superior environment and ensure proper attenuation of airborne sound, it is necessary that the sound transmission class (STC) value of wall panelling and the partition should be 35 (According to IS: 9901 (Part III) – 1981, DIN 52210 Part IV- 1984, ISO: 140(Part III) -1995, as per the test report from UL / Intertek / NABL/ reputed test laboratory.
5) Seismic safety of users & equipment is a prime concern area. The metal panelling/partition must sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations. The test must be carried out by an authorized agency i.e., from UL / Intertek / NABL / reputed test laboratory.
6) The wall panelling should be robust & strong enough to sustain the routine loads/minor impacts of a typical office environment. The wall panelling/partition structure shall have audit certified design feature (from UL / Intertek / NABL/ reputed test laboratory) of Load-bearing capacity of 300 Kgs to hold any display unit on clamp having a minimum length of 750mm. | 147 | Sq. Mtr. | 34,261.92 ₹59,43,073.29 | 33,264 ₹57,69,973.44 Lowest |
| 4.00 | SITC of Printed Panelling
1) The printed panelling shall have the same technical specifications as that of acoustic metal panelling (Wall Finishing - Sr No. 1 acoustic metal panelling). However, in addition to it, the front tile shall be digitally printed. Graphics shall be approved by the Customer.
2) Digital printing shall be done on modular metal Panelling. Pasting stickers/flex/vinyl on metal tile shall be deemed unacceptable.
3) The structure shall be made from a modular, heavy-duty powder-coated CRCA frame (minimum sheet thickness 1mm) and shall allow an uninterrupted flow of wires/cable/tubes of maximum diameter 25mm.
4) The structure shall be securely connected from the wall, roof and floor. It shall be made up of a minimum of 1mm thick vertical slotted rolled C sections (Upright) and horizontal rolled ‘C’ connectors. Grid of the desired dimension shall be formed by Vertical and horizontal sections having 20 to 50mm pitch.
5) For Structure: - Powder coated CRCA steel sheet. (Sheet thickness minimum 1.0mm with powder coating).
Detailed specifications and mode of execution is mentioned in technical Specification of RFP. | 6.5 | Sq. Mtr. | 31,915.8 ₹2,44,794.16 | 30,396 ₹2,33,137.32 Lowest |
| 5.00 | SITC of Acoustic Modular metal acoustic batten panelling
1. Modular acoustic metal batten paneling of 1”x1” made up of extruded aluminum with “T-groove for click-on system”. Extruded Aluminum must be finished with PVC free material and Textured wooden finish shall be provided. Sublimation/Heat transfer method shall not be used to achieve better scratch resistance.
2. Die casted click on joinery shall be used with spring system for fixing to be used for improved rigidity.
3. The structure system shall have grooves to insert polyethylene terephthalate acoustic board.
4. The paneling shall have superior acoustics and shall adhere to the highest health and safety standards. Same system can be installed on curvilinear wall as per the design requirements. Detailed specifications and mode of execution is mentioned in technical Specification of RFP. | 75 | Sq. Mtr. | 12,156.36 ₹10,75,837.5 | 11,918 ₹10,54,743 Lowest |
| 6.00 | SITC of Modular glass partition with metal wire-raceway/skirting on top & bottom
Glass partitions made of 12mm toughened glass installed over 100mm modular metal wire-raceway/skirting on the top & 450mm at the bottom. The modular metal wire-raceway/skirting shall have the same material as that of modular metal panelling/partition. The proper structure shall be made to ensure fixing of glass from RCC slab above the false ceiling and support on partition structure below. Straight & vertical structural members shall not be visible. Glass shall be fitted on anodized extrusion with tool-less technology and having a provision for replacing the glass with perforated sheet/acoustic tile by removing the glass. NOTE: - The nature of installation shall be replaceable, expandable, and flexible to cater to the future expansion/technical up-gradation. Detailed specifications and mode of execution is mentioned in technical Specification of RFP. | 22 | Sq. Mtr. | 16,941.31 ₹4,39,796.5 | 15,833 ₹4,11,024.68 Lowest |
| 7.00 | SITC of 12mm thick frameless tempered clear glass door.
1) 12mm thick frameless tempered clear glass door
2) With door spring and locking arrangements and both way handle and patch fittings.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP. | 30 | Sq. Mtr. | 17,090.38 ₹6,04,999.5 | 16,123 ₹5,70,754.2 Lowest |
| 8.00 | SITC of Metallic Door (with OR without Vision Panel)
With door hinges and locking arrangements and both way handle. Prepare with rigid thermo fused film metal panels. Specification: 0.6mm thick Metal panel sheets, internal cavity filled with adequate quantity of honeycomb. Material of the partition and that of metal door will remain the same. Material of the partition and that of metal door will remain the same. The door thickness shall be minimum 45mm and frame thickness shall be minimum 115mm. Detailed specifications and mode of execution is mentioned in technical Specification of RFP. | 97 | Sq. Mtr. | 25,583.04 ₹29,28,235.03 | 23,688 ₹27,11,328.48 Lowest |
| 9.00 | SITC of Designer Metal Baffle ceiling
1) The baffles shall be made up of a CRCA Powder Coated sheet. These baffle planks shall be bent through CNC to have dimensions as 80X50mm or as per the design approval or as per EIC approval.
2) Centre to centre distance shall be a minimum 150mm.
3) Designer metal baffle ceiling shall be greenguard gold certified from UL / Intertek / NABL / reputed test laboratory.
4) To ensure the restriction of hazardous substances; so that the final product does not contaminate the environment and we give a healthy life to our coming generations it is necessary that the metal ceiling system shall be RoHS certified (from UL / Intertek / NABL / reputed test laboratory).
5) It is well known that metal is resistant to fire as compared to wood & fabric. However, from a fire and safety point of view, to ensure that the used material is not subjected to any kind of surface treatment which provokes fire. The proposed ceiling tiles shall be class A certified as per ASTM e84 (from UL / Intertek / NABL / reputed test laboratory) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire.
6) Specifications (Finish and component details)
7) Ceiling Baffle tile: minimum 0.7mm thick CRCA Powder Coated sheet .
8) Carrier made of 0.60 mm CRCA steel sheet, powder coated to matching baffle colour or black as directed by the Customer. Ceiling to have the arrangement to fix, hang and lock the baffles of required sizes and at required intervals. the size of the punched carrier would be a 35x20x35mm bent channel with holes for suspension and fixing secondary channel.
9) The baffles top edge will have a flange of 5mm to fix in the carrier profile. 10) Mother C Channel: minimum 0.8mm thick CRCA steel Sheet with Laser cut profiles.
11) Suspension: The carriers would be placed at every 1200mm (maximum) and suspended by means of a secondary angle, channel fixed to the carrier at every 900 to 1200 mm and this secondary member, in turn, would be suspended by an 8mm rod fixed to the slab by means of 8mm diameter, dash fastener.
12) Top Clamp: 1mm thick CRCA steel Sheet for holding the threaded rod.
13) End Cap: minimum 0.75mm thick CRCA Powder Coated sheet. Endcap similar to main ceiling baffle.
14) The entire structure will be in powder coated CRCA sheet.
15) Metal Strip where baffle planks will be hung should be sleek & sturdy.
16) Colour: As per approval.
17) The ceiling shall have an additional acoustical sheet between adjacent baffles to conceal the above ceiling services (HVAC & firefighting services) and enhance the aesthetic appeal.
Detailed specifications and mode of execution is mentioned in technical Specification of RFP. | 51 | Sq. Mtr. | 15,520.04 ₹9,33,996.15 | 15,068 ₹9,06,792.24 Lowest |
| 10.00 | SITC of Designer Acoustic Metal Ceiling of size 550X1150mm
1. Providing & fixing of Designer metal ceiling of powder coated tiles of minimum size 550X1150mm.
2. Tiles Perforation – To achieve acoustics without deteriorating the aesthetical appeal of the interior it is necessary that the at-least twenty five percent of the ceiling tiles have micro-perforations (less than 1.6mm diameter each) all over the surface with a density of 5000 holes per square feet. The ceiling tile to have clean perforations and provides a smooth finish on the front fascia of tiles.
3. The proposed ceiling metal tiles shall be Class A certified/tested as per ASTM e84 (from UL / Intertek) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire.
4. To ensure restriction of hazardous substances; so that the final product does not contaminate the environment and we give a healthy life to our coming generations it is necessary that the modular metal ceiling system shall be RoHS certified (from UL / Intertek).
6. The structure shall be made from a heavy-duty powder-coated CRCA steel sheet (minimum sheet thickness 0.8 to 1.6mm). It shall be securely grouted from the roof with help of an anchor fastener and GI self-threaded rods. Detailed specifications and mode of execution is mentioned in technical Specification of RFP. | 729 | Sq. Mtr. | 7,471.8 ₹64,27,388.88 | 7,116 ₹61,21,325.52 Lowest |
Tender Value
₹7.3 Cr
EMD Value
₹14.7 L
Closing Date
1 Dec 2022, 11:00 amClosed
Commissioner DOITC
Yojana Bhawan Jaipur
RFP for Interior works and MEP works of Makeshift Digital Fintech Institute at JNVU campus Jodhpur
2022_DoIT_304285_1
F11(67)/DOITC/Prj/2022/07527
Open Tender
Miscellaneous Works
Item Rate
90 days
Jodhpur
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,000
Yes
Commissioner DOITC
₹14.7 L
Conference hall DoITC Yojana Bhawan
12 Dec 2022
10 Nov 2022
1 Dec 2022
10 Nov 2022
1 Dec 2022
10 Nov 2022
22 Nov 2022
Amount
Interior Work
SITC of Acoustic Metal Partition 1) The material of construction and technical specification shall remain the same as per acoustic metal panelling (Sr No. 1 acoustic metal panelling) however in partition the cladding shall be done on both sides of the section/grid work. 2) Factory-made removable type self-inter-lockable metal panels with a front sheet of preformed textured hot-dip galvanized sheet with rigid polyvinylchloride (PVC) film on one side and on the other side a coating to avoid rust (sheet thickness 0.6mm & PVC Coating at least 0.11mm). The back cover of the panel shall be made up of a 0.6mm thick CRCA/GI sheet of approved colour. The panelling design shall comprise of a specially designed combination of perforated and non-perforated panels through CNC laser cutting, bending & punching. The panelling/partition shall be Greenguard gold certified from UL / Intertek / NABL / reputed test laboratory. The necessary certificate / test report valid on the bid date and to be submitted along with the technical bid. Panels shall be designed to achieve shape and design as per the design consultant and shall be fixed using GI/CRCA hook fitting on the structure. Overall system thickness for panelling shall be 60mm to 90mm and for partition shall be 70mm to 120mm. 3) Tiles Perforation – To achieve acoustics without deteriorating the aesthetical appeal of the office interior it is necessary that the at-least twenty-five per cent of the wall panelling tiles have micro-perforations (less than 1.6mm dia. each) all over the surface with a density of 5000 holes per square feet. This feature shall be audit certified (from UL/Intertek/NABL/ reputed test laboratory) on modular wall panelling tile to have clean perforations and provide a smooth finish on the front fascia of tiles. The tile shall have 5000 holes per square foot on the front side of the tile. 4) To provide an acoustically superior environment and ensure proper attenuation of airborne sound, it is necessary that the sound transmission class (STC) value of wall panelling and the partition should be 35 (According to IS: 9901 (Part III) – 1981, DIN 52210 Part IV- 1984, ISO: 140(Part III) -1995, as per the test report from UL / Intertek / NABL/ reputed test laboratory. 5) Seismic safety of users & equipment is a prime concern area. The metal panelling/partition must sustain the seismic vibrations as per design spectrum IS 1893 for zone 4 vibrations. The test must be carried out by an authorized agency i.e., from UL / Intertek / NABL / reputed test laboratory. 6) The wall panelling should be robust & strong enough to sustain the routine loads/minor impacts of a typical office environment. The wall panelling/partition structure shall have audit certified design feature (from UL / Intertek / NABL/ reputed test laboratory) of Load-bearing capacity of 300 Kgs to hold any display unit on clamp having a minimum length of 750mm.
SITC of Printed Panelling 1) The printed panelling shall have the same technical specifications as that of acoustic metal panelling (Wall Finishing - Sr No. 1 acoustic metal panelling). However, in addition to it, the front tile shall be digitally printed. Graphics shall be approved by the Customer. 2) Digital printing shall be done on modular metal Panelling. Pasting stickers/flex/vinyl on metal tile shall be deemed unacceptable. 3) The structure shall be made from a modular, heavy-duty powder-coated CRCA frame (minimum sheet thickness 1mm) and shall allow an uninterrupted flow of wires/cable/tubes of maximum diameter 25mm. 4) The structure shall be securely connected from the wall, roof and floor. It shall be made up of a minimum of 1mm thick vertical slotted rolled C sections (Upright) and horizontal rolled ‘C’ connectors. Grid of the desired dimension shall be formed by Vertical and horizontal sections having 20 to 50mm pitch. 5) For Structure: - Powder coated CRCA steel sheet. (Sheet thickness minimum 1.0mm with powder coating). Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Acoustic Modular metal acoustic batten panelling 1. Modular acoustic metal batten paneling of 1”x1” made up of extruded aluminum with “T-groove for click-on system”. Extruded Aluminum must be finished with PVC free material and Textured wooden finish shall be provided. Sublimation/Heat transfer method shall not be used to achieve better scratch resistance. 2. Die casted click on joinery shall be used with spring system for fixing to be used for improved rigidity. 3. The structure system shall have grooves to insert polyethylene terephthalate acoustic board. 4. The paneling shall have superior acoustics and shall adhere to the highest health and safety standards. Same system can be installed on curvilinear wall as per the design requirements. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Modular glass partition with metal wire-raceway/skirting on top & bottom Glass partitions made of 12mm toughened glass installed over 100mm modular metal wire-raceway/skirting on the top & 450mm at the bottom. The modular metal wire-raceway/skirting shall have the same material as that of modular metal panelling/partition. The proper structure shall be made to ensure fixing of glass from RCC slab above the false ceiling and support on partition structure below. Straight & vertical structural members shall not be visible. Glass shall be fitted on anodized extrusion with tool-less technology and having a provision for replacing the glass with perforated sheet/acoustic tile by removing the glass. NOTE: - The nature of installation shall be replaceable, expandable, and flexible to cater to the future expansion/technical up-gradation. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of 12mm thick frameless tempered clear glass door. 1) 12mm thick frameless tempered clear glass door 2) With door spring and locking arrangements and both way handle and patch fittings. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Metallic Door (with OR without Vision Panel) With door hinges and locking arrangements and both way handle. Prepare with rigid thermo fused film metal panels. Specification: 0.6mm thick Metal panel sheets, internal cavity filled with adequate quantity of honeycomb. Material of the partition and that of metal door will remain the same. Material of the partition and that of metal door will remain the same. The door thickness shall be minimum 45mm and frame thickness shall be minimum 115mm. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Designer Metal Baffle ceiling 1) The baffles shall be made up of a CRCA Powder Coated sheet. These baffle planks shall be bent through CNC to have dimensions as 80X50mm or as per the design approval or as per EIC approval. 2) Centre to centre distance shall be a minimum 150mm. 3) Designer metal baffle ceiling shall be greenguard gold certified from UL / Intertek / NABL / reputed test laboratory. 4) To ensure the restriction of hazardous substances; so that the final product does not contaminate the environment and we give a healthy life to our coming generations it is necessary that the metal ceiling system shall be RoHS certified (from UL / Intertek / NABL / reputed test laboratory). 5) It is well known that metal is resistant to fire as compared to wood & fabric. However, from a fire and safety point of view, to ensure that the used material is not subjected to any kind of surface treatment which provokes fire. The proposed ceiling tiles shall be class A certified as per ASTM e84 (from UL / Intertek / NABL / reputed test laboratory) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire. 6) Specifications (Finish and component details) 7) Ceiling Baffle tile: minimum 0.7mm thick CRCA Powder Coated sheet . 8) Carrier made of 0.60 mm CRCA steel sheet, powder coated to matching baffle colour or black as directed by the Customer. Ceiling to have the arrangement to fix, hang and lock the baffles of required sizes and at required intervals. the size of the punched carrier would be a 35x20x35mm bent channel with holes for suspension and fixing secondary channel. 9) The baffles top edge will have a flange of 5mm to fix in the carrier profile. 10) Mother C Channel: minimum 0.8mm thick CRCA steel Sheet with Laser cut profiles. 11) Suspension: The carriers would be placed at every 1200mm (maximum) and suspended by means of a secondary angle, channel fixed to the carrier at every 900 to 1200 mm and this secondary member, in turn, would be suspended by an 8mm rod fixed to the slab by means of 8mm diameter, dash fastener. 12) Top Clamp: 1mm thick CRCA steel Sheet for holding the threaded rod. 13) End Cap: minimum 0.75mm thick CRCA Powder Coated sheet. Endcap similar to main ceiling baffle. 14) The entire structure will be in powder coated CRCA sheet. 15) Metal Strip where baffle planks will be hung should be sleek & sturdy. 16) Colour: As per approval. 17) The ceiling shall have an additional acoustical sheet between adjacent baffles to conceal the above ceiling services (HVAC & firefighting services) and enhance the aesthetic appeal. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Designer Acoustic Metal Ceiling of size 550X1150mm 1. Providing & fixing of Designer metal ceiling of powder coated tiles of minimum size 550X1150mm. 2. Tiles Perforation – To achieve acoustics without deteriorating the aesthetical appeal of the interior it is necessary that the at-least twenty five percent of the ceiling tiles have micro-perforations (less than 1.6mm diameter each) all over the surface with a density of 5000 holes per square feet. The ceiling tile to have clean perforations and provides a smooth finish on the front fascia of tiles. 3. The proposed ceiling metal tiles shall be Class A certified/tested as per ASTM e84 (from UL / Intertek) for surface spread of flame and smoke generation. This is mandatory to ensure that the materials used in the interiors do not provoke fire. 4. To ensure restriction of hazardous substances; so that the final product does not contaminate the environment and we give a healthy life to our coming generations it is necessary that the modular metal ceiling system shall be RoHS certified (from UL / Intertek). 6. The structure shall be made from a heavy-duty powder-coated CRCA steel sheet (minimum sheet thickness 0.8 to 1.6mm). It shall be securely grouted from the roof with help of an anchor fastener and GI self-threaded rods. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Acoustic Laminate flooring To avoid distraction of users because of unwanted noise generated from movement of chairs/people in the room it is necessary that the proposed flooring shall damp such impact noises. Acoustic flooring (shall reduce impact sound by 14dB (ISO 717-2)). It shall be twin-layer linoleum built up from minimum 2mm acoustic laminate and a 2mm corkment backing. Flooring shall be decorative type of approved shade, pattern, texture, and design and of approved manufacturer. Dimensions shall be as per the final approved design and site requirement. Flooring shall be laid over concrete floor with laying compound strictly as per manufacturer’s specification. The designer acoustic flooring shall be Greenguard gold tested / certified. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Designer Privacy film for glass partitions & glass door The film to be installed on clear glass to provide the look of sandblasted glass. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Fixed window with aluminium frame Aluminium framed fixed window with “z” frame, powder coated, 16-gauge frame/sub frame, 5.5mm thick float glass & EDPM beading. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Laser Cut Alphabets made up of 316 grade Stainless Steel.
SITC of Curtains for windows: Roll down curtains Supply and installation of manual roller blinds having aluminium roller tube along with fabric pasted on it with glue having control unit for manual operations and bottom bar aluminium powder coated for weight pupose,including fabric fitting and accessories of approved make and colour etc complete.
Furniture
SITC of Reception Counter (Type 1) 1) The furniture work surface shall be straight in shape to maintain grand aesthetic appeal. It shall be made of minimum 25mm thick MDF finish. 2) The structure shall be made up of powder coated steel / Extruded Aluminum Alloy / MDF / board finish. 3) The working side edge: - Audit certified design (from UL/Intertek) feature on front modular polyurethane (PU) edge. High density polyurethane foam molded on industrial grade aluminum core to form minimum 50mm deep tapered edge to be installed on worktop. The edge shall be mechanically replaceable within 30 minutes in case of damage or wear without opening or removing the top. 4) Accesorires : Flap with provision and SITC of 2 nos 16 Amp modular Switch and 3 nos 6/16 amp modular Socket with cat-6 LAN point and wire flow can be made as per requirement of Engineer in charge 5) Design as per engineer in charge approval. Approximate minimum Dimensions – 3000mm(W) X 750mm(D) X 750mm(H). Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of 3-Seater Sofa The top shall be of Upholstery with PU Finish. The sofas are made of solid wood base, reinforced with supportive addendum in the seat. Engineered wood panels form/support the overall design structure, they synergize with the solid wood to offer unparalleled life to the product. Foam padding of multi-density and varying thicknesses provide cushion for the sofa. PU foam used is made Hennecke foam plants using German Technology capable of producing the high-quality flexible polyurethane foam. It provides unparalleled comfort, ease of use and durability. The foam used is 32 Density for seating areas and 28 Density for backrest. The super soft foam used is in seating areas in 32-35 Density High-resilience (HR) foam which is unique and rarely used by manufacturers. Webbing: Interwoven high tensile elastic bands for optimum comfort and endurance. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Center unit for sofa Centre unit for sofa, Toughened Glass, 12mm Thick, Chrome Plated Pipe Frame. Approximate minimum Dimensions – 1200mm(W) X 600mm(D) X 450mm(H) Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Workstation Desk 1) Linear shape tabletop shall be of 25 mm thick MDF board. 2) The working side edge: - Audit certified design feature on front modular Polyurethane (PU) Edge. High density Poly Urethane Foam moulded on industrial grade aluminum core to form minimum 50mm deep tapered edge to be installed on worktop. The edge shall be mechanically replaceable within 30 minutes in case of damage or wear without opening or removing the top. 3) Legs: Ergonomically designed and matching with the open office concept. The leg is made out of sheet metal. 4) The screen shall be made of minimum 8mm thick frosted acrylic or fabric panel. 5) Under structure pipe shall be made up of minimum 1.6mm thick CRCA Laser cut components, powder coated with the matching shade/color/finish. 6) Cable tray: Shall be made up of 1mm thick CRCA sheet, Cable tray is used for running the wires between the desk. Powder coating as per RAL shade incompliance with IS standard (CRCA sheet: IS 513, Powder Coating ISI 01). Provision of switch socket and wire flow can be made as per requirement of Engineer in charge. 7) Accesorires : Flap with provision and SITC of 2 nos 16 Amp modular Switch and 3 nos 6/16 amp modular Socket with cat-6 LAN IO point and wire flow can be made as per requirement of Engineer in charge 8) The desk shall be Greenguard gold tested/certified (from UL / Intertek). Approximate minimum Dimensions – 1200mm (W) X 600mm(D) X 750mm(H) Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Metal Storage Versatile 3-drawer office storage system solution shall be made up of 0.8mm ‐ 1mm CRCA sheets with powder coated finish. The drawers are meant to store stationary items like pens, calculators, staplers, files, folders, documents etc. It comes with sliding drawers and single lock operation along with caster wheels for 360‐degree movement. The storage shall be greenguard gold tested/certified (from UL / Intertek). Approximate minimum Dimensions – 420mm(W) X 450mm(D) X 550mm(H) Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Medium Height Storage Flat pack made up of minimum 0.6mm CRCA powder coated finish with hinged doors and adjustable shelves for different file heights. The storage shall be greenguard gold tested/certified. Approximate minimum Dimensions – 900mm(W) X 450mm(D) X 1200mm(H) . Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Classroom/Training Table 1) Tabletop shall be of 25 mm thick MDF board. 2) The working side edge: - Audit certified design feature (from UL / Intertek / NABL / reputed test laboratory) on front modular Polyurethane (PU) Edge. High density Poly Urethane Foam moulded on industrial grade aluminum core to form minimum 50mm deep tapered edge to be installed on worktop. The edge shall be mechanically replaceable within 30 minutes in case of damage or wear without opening or removing the top. 3) Legs: The leg is made out of metal sheet. 4) Accesorires : Switch Board with provision and SITC of 2 nos 16 Amp modular Switch and 2 nos 6/16 amp modular Socket with cat-6 LAN socket point and wire flow can be made as per requirement of Engineer in charge 5) Under structure pipe shall be made up of minimum 1.6mm thick CRCA Laser cut components, powder coated with the matching shade/color/finish. 6) The manufacture shall be FSC certified. 7) The table shall be Greenguard gold tested/certified (from UL / Intertek / NABL / reputed test laboratory). Approximate minimum Dimensions – 1050mm (W) X 750mm (D) X 750mm(H) Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Cabin Desk (Type 3) 1) The furniture top shall be made up of minimum 25mm thick MDF board. 2) The working side edge: - Audit certified design (from UL/Intertek) feature on front modular Polyurethane (PU) Edge. High density Poly Urethane Foam moulded on industrial grade aluminum core to form minimum 50mm deep tapered edge to be installed on worktop. The edge shall be mechanically replaceable within 30 minutes in case of damage or wear without opening or removing the top. 3) The under structure and complete structure shall be made up of 18mm thick MDF board. 4) The furniture is equipped with handles for easy opening along with soft closing drawers. The Construction shall be of high quality MDF board. 5) The furniture top shall have power box with access flap for wire management. The design shall be as per attached image and as per the Engineer in charge approval. 6) The desk shall be Greenguard gold tested/certified (from UL / Intertek). 7) Accesorires : Switch Board with provision and SITC of 2 nos 16 Amp modular Switch and 3 nos 6/16 amp modular Socket with cat-6 LAN IO socket point and wire flow can be made as per requirement of Engineer in charge Table – 2100mm(W) X 750mm (D) X 750mm(H) Side Runner – 900mm(W) X 450mm(D) X 750mm(H) Back Runner – 2100mm(W) X 450mm(D) X 750mm(H).
SITC of Chair Type 1 Single Lever Adjustment, Tension Control, Tilt Lock, Automatic Lumbar Support, Synchro-Tilt Mechanism Seat Height Adjustment, Waterfall Seat, Back Height Adjustment, Seat Depth Adjustment, Arm Height, Depth & Swivel Adjustment Headrest with Height and Angle Adjustment, All parts of the chair are replaceable and kept in stock for longer life-Cycle 97% Recyclability, Greenguard Certified, Meets EN5459, EN 1335-2: 2009 and EN 1335-3:2009, ANSI/BIFMA X5.1 Certified Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Chair Type 3 Medium Back, Mesh Back, Silver Epoxy Backbone, Synchronized Mechanism, 3-Way Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong nylon Base, Seat - Fabric and mesh backrest, Greenguard Certified, ANSI/BIFMA X5.1 certified. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of Chair Type 4 Low back visitor model ABS for seat, Mesh back with extra lumber Support with fine tuning for depth adjustment, with fixed armrest, silver epoxy cantilever base Upholstery: Black Fabric Seat & mesh backrest. Detailed specifications and mode of execution is mentioned in technical Specification of RFP.
SITC of 3 door locker (Size 380mm(W) X 457mm(D) X 1830mm(H) 1) Material: Cold rolled closed annealed (CRCA) sheet, 2) Thickness: 0.8 mm, 3) Finish: Epoxy powder coat comply, 4) Fixed Shelves, 5) Construction: Revited joints for easy construction and finish & side panel, 6) slotted profile for shelf adjustment, 7) Hinges: Spring Hinges / Soft closing hinges 8) Foot leveling: M6 Threaded top groove Rod with ABS molded. 9) PVC Handle: PVC Molded handle with groove for finger grip 10) Double Layered door with number combination lock with 1 fix and 1 adjustable shelve in each compartment.
SITC of Dustbins/Recycling Units Recycling Unit shall be made with hinged doors and two holes for collection of different waste. Shall be made of 0.6-0.8 mm thick Steel. All edges shall be Double leafed. Dimension: 1000 mm (W) X 1170 mm (H) X 450 mm (D)
Cost of submission of working drawings of interior, civil and MEP works, as built drawings after completion of interior, civil and MEP works is in the scope of Bidder
Description of Work / Item(s)
Amount
Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work in M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) & minimum cement content to be 250 kg per Cu.mt
Terrace Water Proofing Providing and laying water proofing treatment on roofs of slabs by applying cement slurry mixed with water proofing cement compound consisting of applying : a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proffing cement compound @ 0.253 kg/sqm. b) laying second layer of Fiber glass cloth when the first layer is still green . Overlaps of joints of fiber cloth should not be less than 10 cm . c) Third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proffing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30cm on parapet wall and tucked into groove in parapet all around d) fourth and final layer of brick tiling „with cement mortar or any other approved protective coarse. (which will be paid for separately) For the purpose of measurement the entire treated surface will be measured
Brick work with common burnt clay bricks of class designation 7.5 in superstructure above plinth level upto all floor in all shapes and sizes in : Cement mortar 1 : 4 (1 cement : 4 coarse sand) (the rate is inclusive of work upto all floor level including scaffolding & double scafloding )
Half brick masonry in Superstructure , above plinth level upto all level using bricks of designation 75 Cement mortar 1 : 4 (1 cement : 4 coarse sand) and providing and placing in position 2 Nos. ,6mm Ø M.S. bar at every third course of half brick masonry .(the rate is inclusive of work upto all floor level including scaffolding & double scafloding )
Providing and fixing steel gate, grating, and grills made of angles, tees, square bars, flats,or black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. The rate shall include the cost of primer and enamel paint on all structural steel work.
Plaster on new surface on walls in cement sand mortar 1:4 including racking of joints etc. complete fine finish : 12 mm thk. (the rate is inclusive of work upto all floor level including scaffolding & double scafloding )
Providing and fixing Chicken mesh jali (22 gauge) at the junction of 2 different surfaces of different material component at the time of plastering to prevent cracking in plaster surface as and where directed at all floors with all leads and lifts etc.complete.
Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding: Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect.
Finishing walls with Acrylic Smooth exterior paint of required shade including all scaffolding. New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm).
Providing and applying white cement based putty over plastered surface to prepare the surface even and smooth complete.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : One or more coats on old work.
Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 grams per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement , all complete as per direction of Engineer-in-charge.
Drilling or Core cutting, horizontal, vertical or inclined holes in reinforced cement concrete and / or hard rock & filling the gape with suitable materials.
Diameters above 32 mm but up to 100 mm for a depth / length upto 450 mm
Diameters above 100 mm upto 200 mm for a depth / length upto 450 mm
Providing and fixing concertina coil fencing with required dia 610 mm (having 15 nos. round per 6 metre length) up to 3m height of wall with existing angle iron 'Y' shaped placed 2.4 m apart and with 9 horizontal R.B.T. stud tied with GI staples and GI clips to retain horizontal including necessary bolts or GI barbed wire tied to angle iron all complete as per direction of Engineer In Charge with reinforced barbed tape (R.B.T.)/Spring core(2.5 mm thick) wire of high tensile strength of 165 kg/sq.mm with tape (0.52 mm thick) and weight 43.478 gm/metre (Cost of MS angle, CC block shall be paid extra) RBT Reinforced Barbed Tape BTOBarbed Tape Obstacle 30 having Blade length ,Blade width ,Blade space ,Core wire dia All as per given specification of RFP
Clearing grass and removal of the rubbish upto a distance of 5 km outside the periphery of the area cleared.
Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 5 km outside the periphery of the area cleared.
Dismatling and Demolishing Work
Demolishing stone rubble masonry in cement mortor manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 5 km lead as per direction of Engineer-in-charge
Demolishing CC/R.C.C. work by mechanical power driven means and stockpiling at designated locations and disposal of dismentled material up to to lead of 5 km, stacking serviceable and unserviceable material seperately including cutting reinforcement bars
Demolishing Brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 5 km lead as per direction of Engineer-in-charge: In cement mortar.
Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. complete and stacking within 50 meters lead:
Of area 3 square meter and below.
Of area exceeding 3 square meter.
Demolishing mud phuska/ Lime dhar/ Kharanja in terracing and disposal of unserviceable material within 5 km lead.
Dismantling tile work in floors and roofs laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 5 km lead: For thickness of tiles 25mm to 40mm.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 5 km lead.
Providing and fixing of water cooler of capacity 300 liters including reverse oasis and UF/UV tratement for drinking as per detail drawing.
SITC of Sign board Providing and fixing Name plate for individual cabin and rest of the area. Signage's are made up of laser cut Anti-Corrosive high grade AISI 316 Stainless Steel of 2mm thick sheet with laser cut method for impression and with satin finish. Approx. Dimensions: 300 mm X 170 mm X 2 mm.Design and detailing provided by as per engineer in charge
Supply & Installation of Sensor Operated Sliding Glass Door - 12mm thick , 3000mm wide, Height shall be 2400mm as per detailed Specifications, Preferred MAKE & View in RFP
Providing and fixing wall poster on wall/paneling of acrylic sheet with UV print in mirror impression on back side of 3 mm thick acrylic sheet with white layer, pasted on wall using 3m Tape. (Size-2'x3')
Providing and fixing wall poster on wall/paneling of Cotton Canvas Cloth with multicolour UV printing mounted on wooden framing.
Providing and fixing 3mm thick black acrylic sheet with golden letters (Inaugral Plage)
Supplying and placement of potted plants FRP POTS of Rou Compe S1, S2, S3 (CREDO or similar) including cocopit, manure, plants and complete in all respects
Supplying and planting following PALMS
Arica palm (Height- 3 Feet)
Raphis palm (Height- 3 Feet)
Gulmohar (Height- 3 Feet)
Golden bamboo (bamboo can plam) (Height- 3 Feet)
Providing & Fixing PVC Storage Tank ISI Marked (IS : 12701) indicating the BIS license No), of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:1000 litres capacity.
Providing & Fixing Bevelled edge Mirror of special glass of approved make (Atul, Modi Guard, Saint Gobin or equivalent) complete with 6mm thick asbestos cement sheet ground fixed to wooden screws & washers.
P&F Soap dispenser (Heavy Traffic) of approved quality/ make. Makes EURONiCS ES09
Providing & fixing of uPVC SWR pipes (Type-A) conforming to IS 13592 along with all required fittings like tees, bends, crosses with or without access doors jointed with approved solvent cement fixed to walls with clamps complete including angle supports, brick work (slab/beam/wall) and making good the floors and walls with cement mortar where required complete of outer diameter.
110mm outer dia.
Providing and fixing uPVC pipes of 6 Kg./cm2 conforming to IS: 4985 including all fittings with or without access door i.e bends, junctions, cowls, offsets, etc., and jointing with solvent cement, including cutting holes in walls and floors, wherever required and making good the same, complete as directed by the Engineer-in-Charge.
Providing and fixing uPVC Floor TRAP of required size complete in all respects.
Providing and fixing uPVC Floor Drain with PVC grating 75 mm dia. or 75 x 75 mm square with frame complete in all respects. (Floor drain)
Providing and fixing CPVC (Chlorinated Poly Vinyl Chloride) grade CTS SDR 11 pipes, conforming to I.S.15778 : 2007, having thermal stability for hot & cold water supply including suitable male / female plain and brass threaded CPVC fittings (Tees, Elbows, Couplers, Unions, Reducers, etc.), transition fittings connection between CPVC & metal pipe/G.I i.e. Brass Adaptors (Both male & Female threaded) conforming to ASTM D-2846 with only CPVC solvent cement conforming to ASTM F-493, fixing the pipe with clamps at 1.00 m spacing, testing of joints and termination of all faucet installation points with brass termination fittings complete. (Exposed Pipes in shafts & Internal pipes for Dom &Flushing water)
20 mm dia.
25 mm dia.
32 mm dia.
40 mm dia.
50 mm dia.
Providing and fixing BRASS ball valve with cenemnt solvant complete in all respect..
25 mm dia. nominal bore
40 mm dia. nominal bore
50 mm dia. nominal bore
P & F Inlet Connection (Angle Valves) Superior quality, of approved make, for Water cooler etc. C.P. Inlet connection 15mm.Brass (IS : 8931 marked)
Constructing brick masonry rectangular type manhole of size given below and depth as per the drawing in cement mortar 1:4 (1 cement : 4 coarse sand), in side cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a floating coat of neat cement and outside rough cement plaster 15 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), foundation concrete 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size), and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement all complete as per standard design.
Description of Work / Item(s)
Amount
Ac Work
Removal /dismantling of following AC units from their existing locations, complete with disconnection and shifting the unit to the new location for complete installation with testing and commissioning.
1.8/2.0 TR hi Wall/split AC
Supplying and charging of fresh refrigerant and testing of performance of air conditioner of following capacity including capillary and strainer/ filter.
2.0 TR Window/ Split A.C.
Servicing of 1.5/2.0 TR capacity Split/ Window type air conditioner
Supply , Installation, Testing and Comissioning of Inverter type Air Cooled Hi Wall split type Air conditioners with latest star rating system as per BEE amended upto date complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 5 Mtr (IDU to ODU), copper power cable upto 8.5 Mtr (IDU to ODU), R-32/R-410 Green Refrigerant, wireless Remote control, suitable for working between 230V +/- 10% with low & high voltage cutoff and 50 hz , single phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
Inverter Type
1.8 TR ISEER not less then 4.6
Supply , Installation, Testing and Comissioning of Air Cooled Cassette type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 8 Mtr (IDU to ODU), copper power cable upto 10 Mtr (IDU to ODU), R-32/R410A Green Refrigerant, wireless Remote, inbuilt drain pump, suitable for 400/230V, +/- 10% 50 Hz ,1 /3 phase AC supply, capable of performing cooling, dehumidification, Air circulation, filteration & ventilation of following capacity with Scroll /rotary/twin rotary compressor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
Inverter Type
2.0 TR ISEER not less then 3.5
Supply & Laying of interconnecting copper refrigerant pipe work with Y joints duly insulated with tubular elastomeric nitrile rubber insulation of thickness as specified, between indoor & outdoor units as per specifications. All piping inside the room shall be properly supported on galvenised perforated trays and all external piping shall run in galvenised covered perforated tray.
Set of Refrigerant Piping for 1, 1.2 and 1.5 TR size (1/4" + 1/2") outer Diameter of pipe 1/4=6.4mm, 1/2=12.7mm wall thickness in mm 0.8mm
Set of Refrigerant Piping for 2 TR size (3/8" + 5/8") outer Diameter of pipe 3/8=9.5mm, 5/8=15.9mm wall thickness in mm 0.8mm
Drain Piping
Supply, installation , testing and commissioning of drain piping complete with fittings, supports, valve and PVC with 6 mm thick closed nitrile rubber foam insualtion / UPVC drain without insualtion as per specifications & drawings.
WIRING
Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it's ISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thick Hot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws, making connections, testing etc. as required. For specification of copper Conductor, Phenolic Laminated sheet's & Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additional technical parameters of product / work refer Annexure 'A' attached with Eelctrical Rajasthan PWD BSR 2022
Short point (up to 3 mtr.)
Medium point (up to 6 mtr.)
Long point (up to 10 mtr.)
Wiring for Twin controlled Light point with 2 x 1.5 Sqmm FRLS PVC insulated, copper conductor Multistrand Flexible wires in surface/ recessed Medium duty PVC conduit & its accessories including the cost of cutting/ making good chases in brick work and including the cost of Supplying and fixing of 2 nos MS boxes & fixing of 2 nos 6 Amp Two way Modular type switch, grid plate, modular cover plate & and also include cost of loop earthing with 1.0 Sqmm FRLS PVC insulated, Copper conductor multistrand Flexible wires Complete as required (up to 10 mtr.)
Wiring of 3 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) of approved make in surface / recessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & it's accessories, 18 SWG 175 mm x 100 mm x 60 mm M.S. box with earth terminal, 6 A switch, 6 A socket, 3.0 mm thick ISI marked phenolic laminated sheet, zinc plated / brass screws, cup washers, making connections, testing etc. as required.
On board
Supplying and fixing of power plug point with Modular accessories as per specification for electrical Works, on hot dipped galvanized modular box of 18 SWG with earthing terminal/connector on surface or in recessed with suitable size of modular face place with grid plate and cover plate including cost of ISI marked modular 16 amp. Switch (IS :3854) and 3/5 pin 16 amp. socket outlet (IS:1293) , making connection , testing , etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along with ISI marked (IS:3419-1988) accessories as required in recess including cutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure 'A' attached with Eelctrical Rajasthan PWD BSR 2022
Supply and fixing following size of Hot dipped Galvanized (275 GSM) floor raceways / Under floor trunking with/ without partion, including with base and cover, junction boxes and floor outlet boxes as required, extension pieces, couplers, end plates, earthing including mechanically cutting chases in floor/ wall etc & making the same good with fixing alluminium profile cover . The race way shall be surface / Concealed type to brick wall / flooring with necessary fixing accessories .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
GI Raceways
75 mm x 38 mm x 1.5 mm
100 mm x 38 mm x 1.5 mm
Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss , oxygen free ( <10 ppm) for less chances of oxidization and higher silver content for gives better conductivity , insulation PVC type A ,flame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, , in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge,making connections, etc. as required. as per recommended makes of RFP.
3x 1.5 sq.mm
2 x 2.5 sq. mm. + 1x1.5sqmm
2 x 4.0 sq. mm. + 1 x 2.5 sq. mm.
4 x 10.0 sq. mm. + 1 x 6.0 sq. mm. (DB supply)
4 x 16.0 sq. mm. + 1 x 6.0 sq. mm. (VTPN supply)
Supplying and drawing flexible / stranded bare copper conductor, PVC / XLPE insulated, overall aluminium mylar tape shielded ATC drain wire and outer PVC sheathed industrial Instrumentation (shielded)cables voltage grade 300/500 V as per BS /EN 50288-7 in existing surface or recessed PVC/ MS conduit/casing capping / Cable tray / Open Duct making connections, testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for cables. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
Armoured(For AC supply)
4 core x 2.5 Sq.mm
DISTRIBUTION BOARDS
Providing & Fixing of 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/ C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per specification for electrical Works with ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductorline load reversibility, label holding facility , IP 20 contact protection and fitted with existing distribution board/sheets, min. operation 20,000 upto 32 A rating and 10,000 upto 63 A, 5000 for 80 A rating including making connections, testing etc. as required. . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
Single pole MCB
6 A to 32 A rating
Double pole MCB
6 A to 32 A rating
Triple pole MCB
40 A 63 A rating
Four pole MCB
40 A rating
50-63 A rating
Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock, min. operation 10,000 upto 63 A rating and 5000 for 100 A rating and minimum phase termination capacity of 35 sq.mm. rigid wire , IP 20 contact protection with existing distribution board / sheet including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure 'A' attached with Eelctrical Rajasthan PWD BSR 2022
Two pole 100/300mA sensitivity
40 A rating
Four pole 100/300 mA sensitivity
40 A rating
63 A rating
P&F Recessed/ Surface mounting heavy duty horizontal type prewired sheet steel Distribution board phophatised / powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link and din bar,masking sheet, loose wire box, terminal block , duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks conforming to IS:13032 & IS:8623 including making internal DB terminations with copper lugs , testing etc. as required.
Metal door (Three phase) Per phase isolation, Horizontal IK-09 and IP-43 with Metal end box
8Way(Incomer 8,Sub Incomer2+2+2)
12 Way(Incomer 8,Sub Incomer2+2+2)
P&F recessed/ surface mounting heavy duty Vertical type 16 SWG sheet steel Distribution board with provision of incomer suitable for MCCB and SP / TP MCB as outgoing , phophatised ,powder painted complete with insulated suitable rating copper bus bar , neutral link, earth link and din bar, masking sheet & conforming to IS13032 & IS8623 including making internal DB terminations with copper lugs , testing etc. as required.
Double door IP-43 & IK-09 with Provision of Incomer MCCB 100/ 125 A Rating with Metal end box
100 Amp, FP, 25 KA, MCCB, having Thermal Magnetic trip unit with adjustable overload , short circuit & earth fault protection
Providing & Fixing of modular type lockable feature socket duly ISI marked (IS :1293) as per specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle (PUSH PART) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
6 A 3 pin shuttered socket
Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) as per specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle (PUSH PART) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
6 A one way switch
Providing & Fixing of following modular accessories as per specification for electrical Works, made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tip with IP-20 rating , minimum width of 1 module switch toggle( PUSH PART ) should not less then 20mm, including all as per pre approved by Engineer in charge,making connections, testing etc. as required. All as per pre approved by Engineer in charge. as per recommended makes of RFP.
Blanking plate
Providing & Fixing of following size mounting grid plates with cover plates as per specification for electrical Works, made from fire retardent UV established high performance engineering plastic suitable for all universal metal boxes for front installation & removal direct fit type complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
1/2 Module
Providing & Fixing of following size hot dip galvanized M.S. box of 18 SWG as per specification for electrical Works, with earthing terminal in recess/ surface suitable for modular accessories as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
1-2 Module
Providing & Fixing of ISO certified company made vergin material PVC trunking system as per specification for electrical Works, with double lock feature for cable management including finishing accessories like corners, tee, adjustable angles, junction etc. as required . The trunking system shall have adaptable system for modular type RJ 45 data socket/ wiring accessories/ power sockets and shall be covered with peal off plastic cover. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
100/105mm x 50mm
32mm x 20 mm
Lighting
Providing & Fixing of Suspended mounting IP66 IK08 rated Integrated High power LED Wellglass light fixture made from Pressure Die Cast Aluminium housing, potted driver, Eye bolt for mounting, PC clear / Opal Diffuser, system lumen efficacy ≥120 lm/Watt output , THD < 10% ,p.f.≥0.95,CRI >70 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. surge protection 4 KV . OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge and shown in 3D diagram . For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 . (Minimum lumen output 3500 lm)
Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid Power LED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. As per approved make of RFP
Recessed Mounting
Minimum lumen output 1950 lm
Providing & Fixing of of ventilating fans Capacitor start, copper wounded, single phase with PVC impeller, ABS body, automatic openable louver shutter in existing opening including making connection, testing etc. as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR .
200 mm sweep
EARTHINGS
Plate Earthing as per PWD specification for electrical Works as per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying 3 to 4 mtr. below the ground level with 20 mm dia. G.I. 'B' class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" Rajasthan PWD BSR 2021.
P & F of Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300 mm. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" Rajasthan PWD BSR 2021.
S & Laying following size earth wire/strip in horizontal or vertical run in ground/surface/recess on SMC insulator including riveting, soldering, saddles, making connection etc. as required.
8 SWG Cu wire
32mm x 6mm copper strip duly PVC sleeved
CABLING WORK
P/Laying P.V.C. insulated & P.V.C. sheathed armoured cable of 1.1 KV grade with aluminium conductor of IS:1554 P-I on cable tray, including cable termination, cable luges, cable gland, making connection, testing etc. as per specification, drawing & recommended make.
4 core 16 sqmm
3.5 core 35 sqmm
3.5 core 50 sqmm
Fabricating & installing following sizes of perforated GI cable trays including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with M.S. suspenders and including painting
150mm x 50mm x 1.6mm
300mm x 50mm x 2mm
Supply, Installation, testing and commissioning of 60 KVA UPS with 3 phase input and 3 phase output with isolation transformer and as per the Technical specifications. Quoted rate shall be inclusive of required batteries of 15 minutes back up at full load, battery shall be with connecting cables, Battery rack, also include copper cable of required size for input supply from main panel and output supply to panel /VTPN DB and all complete as per drawings, technical specifications as per attached in RFP, SLD, relevant standards, and direction of Engineer in charge.
LAN Services:
DATA ,CCTV & TELEPHON WORK
SITC of 5 MP IR Fixed Dome Network Camera -1/2.7 inch Progressive Scan CMOS, 2592 × 1944 at 25fps, 2.8 mm Fixed lens, 0.003 Lux at F1.4, 0 Lux with IR on, ICR, ONVIF (PROFILE S, PROFILE G, PROFILE T), support H.265, H.264, MJPEG, 120db WDR, 3D Digital Noise Reduction, BLC, HLC, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, Support on-board storage up to 256 GB (SD card not included), IP67, IK10, Edge Analytics- Line crossing detection, Intrusion detection, Motion detection, Region entrance detection, Region exiting detection, Scene change detection, Face capture, Video tampering, audio exception detection, False alarm reduction through human and vehicle target classification based on deep learning UL, CE, FCC For additional technical parameters of products/ work as per recommended makes of RFP. For additional technical parameters of products/ work as per recommended makes of RFP.
SITC of 32 Ch Smart Network Video Recorder : Connect Up to 32 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, 2 HDMI at least 1 HDMI 4K, 2 VGA atleast 1 VGA 2MP Output , Support H.265, MJPEG, Incoming Bandwidth 320Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB 2.0 at least 1 USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified.
8TB Surveillance Hard Disk
Supply, Installation & Commissioning of Workstation latest Intel® i7 4th Generation, 21" monitor screen, processor, Intel Chipset motherboard, 16 GB DDR3 RAM, 500 GB SATA HDD at 7200 rpm, Graphic card with 1 GB dedicated RAM with display ports/DVI/ HDMI port, DVD writer, Giga LAN Card, Keyboard, optical Mouse
Supply & Installation of IP-20 & IK-08 , UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with 'U'Marking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19" angles with wall mounting provision on wall. Accessories like: 1 No of 19" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
15 U Rack with Width 600 mm & Depth 400 mm + 100 mm
Supply & Installation of IP-20 & IK-08 , UL Listed Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet,Vertical Mounting Rail 1.6 MM with 'U'Marking, front sturdy sheet steel frame folded from one piece and welded with 5mm toughened glass door, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, Set of 75 mm height 4 castors, 2 of which have brakes, Accessories like: 5 Nos of 19" 1U Horizontal Cable manager, 2 Nos of vertical cable managers, 1 no. Keyboard Tray, 4 Nos of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 2 No of 19" 1U, mountable socket strips with 6 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
36 U Rack with Width 600 mm & Depth 800 mm
Supply, Installation, & Testing of 19" 1U Rack Mounted/ surface mounted aluminum/ CRCA 1.2mm powder coated, multimode glass Fiber Optic Cable Patch panel/LIU loaded with flangless/screwable adapters for ST/E-2000/SC/LC/MT-RJ/PC type, It should have easy removable Top plate with push buttons, there should be a splice tray installed in the Patch panel/LIU which can handle the fiber cores, splice tray should be PC+ABS material, it should include accessories like mounting hardware, gormetts, heat shrink tubes/sleevs, screws, nuts to install the panel for rack/wallmount applications as per requirement complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
Multi Mode LIU 6 Ports
SITC of LC to LC, Bend-Insensitive, Multi Mode(OM4) Fiber Patch Cord, 1.6 mm Duplex, LSZH Sheath as per IEC 60332-3, 10 Feet
Supply, Installation, OTDR Testing & Fusion Splicing of Fiber Multimode Pigtail (50/125 µm) made of glass fiber optic, should be fitted at one end with any one type of single ST/E-2000/SC/LC/MT-RJ/PC type connector in acc. with IEC 61754-20, as per latest ammendments of TIA/EIA 569 Standard Specification as per requirments complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
Supply, Drawing and Testing, of stranded Multi mode (50/125 µm) glass optic fiber cable, as per latest ammendments of TIA/EIA 568/ISO/IEC 11801:2011/ IEC 60794-1-2 E1, E3,E11, F1/ EN 50173-1/ EN 187 000/ IEC 60974-2, 2-20, 2-21/ ITU G.652D, construction of LSZH outer sheath cable, cable should be used for LAN and WAN back bones, . With its LSZH sheathing these cables should be ideal for indoor/outdoor installations in existing MS/PVC /HDPE Conduits/ slotted channels with ferruling at both ends for identification complete in all respect. All as per pre approved by Engineer in charge. as per recommended makes of RFP. (10 -G Cable)
6 core 10G glass optic fiber Cable)
Supply , Installation and Testing of 4 pair, 100 Ohm impedance, Cat 6/6A patch cords should be constructed of minimum 23/24 AWG, stranded bare Copper cable with FRPVC/LSZH Jacket, with an enhanced performance by factory moulded RJ45 connectors as per ANSI/TIA/EIA 568 suitable for Cat 6/6A application complying to latest ammendments Category 6/6A Standards, According. to TIA568, minimum requirement for 1G BASE-T/ 10G BASE-T performance. Patch cords shall be straight thru cable compatible with both T568-A and T568-B wiring schemes, Minimum 750 to 1000 mating cycles in plug contacts for long durability complete in all respect. All as per pre approved by Engineer in charge. as per recommended makes of RFP.
Cat 6, UTP (Un-sheilded Twisted Pair) Patch Cord
Supply, Installation, Testing and Comissioning of Rack mounted 19" 1U, Cat6 24 Port loaded, 1.5-1.6 MM CRS chasis, powder coated, sheet steel, made of plastic (ABS), Modular Patch Panels with Rear Cable management system and mounting hardware to mount the patch panel. Should have port identification numbers printed/engraved on front of the panel. Etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
Modular Patch Panel Loaded with Cat -6 I/O
Supply , Installation, Testing and Comissioning of Managed Layer-2 Intelligent 10/100 Ethernet Switch providing 24 x 10/100/1000 MBPS Giga Ethernet ports / with min 2 SFP Giga Ports (provision for Fiber Giga connectivity) with related LAN Base Software including making connections etc as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
SITC of Intelligent Ethernet POE Switches providing 24 x 10/100/1000 Fast Ethernet POE ports- 370W or better and 4 dual purpose uplink (provision for Copper / Fiber Giga connectivity) with provision of minimum Stacking of 06 Switches with related LAN Base Software . For additional technical parameters of products/ work as per recommended makes of RFP.
Supply, Installation, Testing and Comissioning of Rack mounted , 48 x 10/100/1000 Ethernet ports Gigabit Switch with 4 mini Gigabit Interface Converter slots(shared with 4 Ethernet ports) for Gigabit Ethernet expansion , Switching capacity 96 Gbps nonblocking , . As per recommended makes of RFP.
Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
Supply and Installation of unsheilded/ sheilded Information outlets made of high impact plastic body with ABS, FR Grade with provision for protection against dust in jack/ FP, suitable for Cat 6/6A application complying to latest ammendments, According. to Cat. 6/6A channel, It should support channel as well as components requirements of Cat.6/6A standards at frequencies of up to 250 to 500 Mhz. Cat 6/6A unshielded/shielded Jack should be suitable to terminate 4 pair, 23/24 AWG solid/stranded wire diameters, using 100 Ohm unshielded/shielded balance twisted pair cable, the jack should have tooless/impact punch termination on reliable copper tin plated Insulation displacement contact, It complied with ANSI/TIA/EIA 568 standard. In existing modular/MS Boxes along with necessory connections as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work as per recommended makes of RFP.
Cat 6, Un-sheilded Information Outlet
Supply & fixing of square Faceplate for Flush / Surface Mount Information Outlets Single/Dual or Quad Aperture , material should be PC+ABS body, Suitable for RJ45 unshielded/shielded connection modules. Should match with I. O. OEM. Dimensions should be 86mm X 86mm as required complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with Eelctrical Rajasthan PWD BSR 2022 .
Single Aperture
Supply , Installation , Testing and commissioning of 86", 4K, Android 8.0, 4-core A73 × 2 + A53 × 2, 1.5 GHz, memory 3GB, build-in 32GB storage, build in Zoom, 20 points infrared touch contorl, industrial screen protection. Built-in Wi-Fi realizes wireless screen mirroring without any cable connection. Built-in interactive whiteboard system allows annotating and sharing. as per detail specifications and Preferred makes enclosed in rfp
Opex Part
All in All maintence of the items mentioned in CAPEX part as per the manufacturer guidelines and as installed at site including consumables if any as per details given in RFP
All in All operation of the items mentioned in CAPEX part and as installed at siteas per the manufacturer guidelines like Airconditioner , Electrical instalaltion , UPS , Interactive screens etc by employing 2 Electricians from 9 am to 7PM six days a week / working days as given in RFP
Pyrotech Workspace Solutions Pvt. Ltd.
Eminent Colonizers Private Limited
Pyrotech Workspace Solutions Pvt. Ltd.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.81 MB
RFP.pdf
Tender Documents • 3.83 MB
BOQ_539698.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .