| 1 | L1₹31.0 LAccepted-AOC NOT AVAILABLE | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹35.2 L+₹3.4 L (10.6%)Rejected-Finance E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹41.8 L+₹9.9 L (31.2%)Rejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹44.7 L+₹12.8 L (40.3%)Rejected-Finance 1 14 SUJAL MANSION B BLOCK BHANGWADI KALBADEVI ROAD MUMBAI 400 002 | MUMBAI | MAHARASHTRA | 400002 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹48.6 L+₹16.7 L (52.4%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
4 Sept 2024, 6:00 pmClosed
GE NW NAVY NAGAR COLABA MUMBAI
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINT OF SERVICE CABLE SUBMAIN WIRING ELECTRIC PANEL AT SAILOR MARRIED ACCOMMODATION AND LIFT MACHINE ROOM OF LOW RISE BUILDING OF OLD AND NEW NAVY NAGAR UNDER GE NW NAVY NAGAR
2024_MES_665306_1
8429/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹90,000
Yes
19 Sept 2024
11 Jul 2024
6 Sept 2024
11 Jul 2024
4 Sept 2024
25 Jul 2024
11 Jul 2024 - 31 Jul 2024
Amount
Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 200 Amps rated copper bus bar(All in equal size), top and bottom cable entry with proper size glands including disconnecting cable connections and electronic meters from old meter cabin panel and fixing & connecting in new installed panel with provisions of thimble/lugs and making provisions of vision glasses for meter readings, one spare MCCB compartment, and including PCC on 1:2:4 type B-1 for fixing meter cabin at old meter cabin place complete all as specified and as directed comprising of the following :- Make:- Legrand/Standard/L&T (a) MCCB 100A, 4 pole, 415 volt, thermal magnatic release type, Ics=100% Icu, 25 kA - 01 Nos, Cat No-4200 55 of Make-Legrand/Siemens/L&T/Schneider. (b) MCCB 63A, 4 pole, 415 volt, thermal magnatic release type, Ics=100% Icu, 25 kA-02 Nos, Cat No-4200 53 of Make-Legrand/Siemens/L&T/Schneider. (c) Supply & fix of single phase smart meter , tamper proof, static meter of class 1.0, 240V, 50Hz, 10-60A anti temper feature as per IS 16444. - 10 Nos. Make L&T/Elmeasure/Panasonic (Anchor)/Siemens (d) MCB SPN 32 Amps- 10 Nos Make-Legrand Cat No-4086 17 or eqivalent to L&T/Schnider/ABB. (e) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V, A, F, PF, KW, kVAR, kWH etc of make :- L&T, Cat Ref -WL441010OOOO-01 set or equivalent in Legrand/Schnieder/ABB. (f) Phase indicator lamp R,Y & B - (01 Set of three). (g) Copper Bus bar, 200 Amps Rated - R,Y,B & N - (01Set of four). (h) Reconnecting of submain cable 2 core 4/ 6 Sqmm copper conductor with outgoing of energy meter. (i) Making good the disturbed surface of meter cabin room if any damages occures during shifting of panel. Note :- Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
All as per Item No 1.00 above but comprising of the following :- (a) MCCB 63A, 4 pole, 415 volt, thermal magnatic release type, Ics=100% Icu, 25 kA-02 Nos, Cat No-4200 53 of Make-Legrand/Siemens/L&T/Schneider (b) MCB SPN 32 Amps- 10 Nos Make-Legrand Cat No-4086 17 or eqivalent to L&T/Schnider/ABB (c) Supply & fix of single phase smart meter , tamper proof, static meter of class 1.0, 240V, 50Hz, 10-60A anti temper feature as per IS 16444. - 10 Nos. Make L&T/Elmeasure/Panasonic (Anchor)/Siemens (d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V, A, F, PF, KW, kVAR, kWH etc of make :- L&T, Cat Ref -WL441010OOOO-01 set or equivalent in Legrand/Schnieder/ABB. (e) Phase indicator lamp R,Y & B - (01 Set of three). (f) Copper Bus bar, 100 Amps Rated - R,Y,B & N - (01Set of four). (g) Reconnecting of submain cable 2 core 4/ 6 Sqmm copper conductor with outgoing of energy meter. (h) Making good the disturbed surface of meter cabin room if any damages occures during shifting of panel. Note :- Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
Taking out old u/s and Supply, installing, testing and commissioning of LT feeder pillar box factory made cubical outdoor type, fabricated out of 3.15 mm thick CRCA sheet with angle iron base frame made of 40x40x6mm, 45cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415V 3 phase 4 wire weather proof with IP-66 protection, with separate hinge door for each compartment for incoming and out going MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer after under going a rigorous metal treatment process involving alkaline degreasing, descaling in dilute sulphuric acid or any other acid and phosphate and with copper busbar (TPN), suitable double compression copper cable glands complete in all respect for bay work station and including provn of the following:- Make:- Legrand/Standard/L&T
S&F MCCB 100 Amps, 4 Pole, 25 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
S&F MCCB 63 Amps, 4 Pole, 16 kA, thermal magnetic release, Ics=100% Icu - 01 Nos,
S&F RCBO's 63 Amps, 4 Pole 300mA - 01 Nos,
S&F MCB SPN 40 Amps, 10 kA, - 01 Nos,
Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V,A,F,PF,KW,kVAR,kWH etc of
Phase indicator lamp R,Y & B (Set of 3)- 01 Set
S&F Copper Bus bar 250 Amps of suitable size, all are in equal size - Set 1(R, Y, B, N)
Note: All existing cable connections will be disconnected from old Panel carefully and re-connected with new Panel by providing glands and thimble all as directed by Engr-in-Charge.
Supply and installation of Smart Single Phase Meter with the following specifications: (i) AC Single phase Two Wire, Tamper Proof, Static Meter of Class 1.0, 240 V, 50 Hz, 10 A-60 A conforming to IS-16444 and relevant IEC standards with inbuilt 865-867 MHz Radio Frequency communication facility with self-healing Mesh network with defalult and on demand display, biling date generation facility, anti-tamper features. Microprocessor and LED/LCD based circuitry. (ii) Meter should support the following data : 30 min instaneous data for voltage, current, power factor, power, cumulative energy and frequency, 30 load survey date for energy, mopntly billing survey for cumulative energy and Max Demand. (iii) Meter should have connect/disconnect functionality operable from prepaid billing software. (iv) The meter should support open communication protocol DLMS with the software. MAKE: Secure, L&T, Havells,Elmeasure. Note: (a) The contractor would be responsible from removing the existing meter, noting down the reading and depositing it with the MES. (b) It would be possible to run the meter in both prepaid and postpaid mode. (c) The meters would carry 5 year warranty.
S & F cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified.
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected toExisting earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion.
M&L of aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductors above ground.
M&L of test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw
M&L scrapping old worn out paint from complete indoor type meter cabin panels and painting with one coats of synthetic enamel paint (incl front door in side and indl compartment outer side etc also) over a coat of primer and spray painting complete including fixing sticker danger sign board suitable for LT panel board and replacement of brocken glass of any size all as specified and as directed by engr-in-charge.
M & L in replacement for snap-on trunking system including cover, angles bends and all accessories and fitting of size 50x80 mm fixing on wall complete all specified and directed.
shree arihant constrution (BID ID -3076944)
Shree Ayyappa Engineering (BID ID -3083477)
Chakshu Enterprise (BID ID -3081866)
SHRI SAI ENTERPRISES (BID ID -3076553)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .