Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹6.5 Cr IIND FLOOR PLOT NO 17 SANJAY NAGAR DISTRICT CENTER GHAZIABAD UP 201001 E MAIL VISHAL GAUR LABNATIONINDIA COM E MAIL INFO LABNATION1 GMAIL COM | ₹6.5 Cr |
Tender Value
₹6.5 Cr
Closing Date
25 Nov 2021, 11:00 amClosed
Re- Tender for Supply, Installation, Testing and Commissioning of various Equipment for and on behalf of RLBCAU, Jhansi
NBCC/SBGDelhill/RLBCAU/Equipment/2021/51dated11/11/2021
NBCC/SBGDelhill/RLBCAU/Equipment/2021/51dated11/11/2021
Open Tender-Domestic
Electronics Equipment
Jhansi, Uttar Pradesh
₹11,800
Exempted
24 Jul 2026
11 Nov 2021
25 Nov 2021
25 Nov 2021
11 Jan 2022
Bill of Quantity
Sl No. Description of Items unit Quantity Rate Total Amount
Sl No. Description of Items unit Quantity Rate Total Amount
1 Supply, Installation, Testing and Commissioning of high-speed Nano-spectrophotometer that uses each 1 10,84,702.50 10,84,702.50
traditional UV/VIS spectrometry to provide accelerated micro-volume DNA, RNA, and protein
quantification and quality control. (Detailed specification appended separately in technical specification
of tender documents)
2 Supply, Installation, Testing and Commissioning of Double Beam UV-VIS Spectrophotometer of each 1 5,82,582.00 5,82,582.00
Wavelength range: 190 – 1100 nm, Selectable wavelength: 0.1 nm increments, scan speed: Approx
30000 nm/min, Light source change: Auto change from 300 to 360 nm wavelength range at 0.1 nm
adjustments. (Detailed specification appended separately in technical specification of tender documents)
3 Supply, Installation, Testing and Commissioning of Gel Documentation System of Image resolution each 1 12,38,714.98 12,38,714.98
should be minimum 4 megapixels, System should have Trans UV excitation source and CCD based
detector, Pixel Size should be minimum 4.6 x 4.6 µm. (Detailed specification appended separately in
technical specification of tender documents)
4 Supply, Installation, Testing and Commissioning of Thermal Cycler (Gradient) with Peltier heating and each 2 6,55,404.75 13,10,809.50
cooling based system. System Should have gradient enabled block for 96 well, System Should have a
maximum ramp rate of approx 5 degree C/sec and average ramp rate of approx. 3 degreeC/sec., system
should have the capability to program 8 different annealing temperatures using gradient with dynamic
ramping. (Detailed specification appended separately in technical specification of tender documents)
5 Supply, Installation, Testing and Commissioning of Real time-PCR with HRM analysis system. System each 1 15,68,490.00 15,68,490.00
shall be capable of performing advanced applications like high resolution melt (HRM) analysis and
capable of handling SYBR Green dye based and probe based chemistries, system should have block of 96
x 0.2ml tubes or plate to run typical 0.2 ml tubes, strips and plates, an integrated system for both Real-
Time PCR & post-PCR (end-Point) analysis using in-built peltier based PCR Machine. (Detailed
specification appended separately in technical specification of tender documents)
6 Supply, Installation, Testing and Commissioning of Atomic Absorption Spectrophotometer each 1 26,48,100.00 26,48,100.00
1. Atomizer System
A space-saving compact a true double beam atomic absorption spectrometer.
2. Flame Atomizer, the system should have software controlled automatic vertical and horizontal
alignment of the flame burner head for optimum light transmission. (Detailed specification appended
separately in technical specification of tender documents)
Digitally signed by ARTI
GUPTA 15:40:17 IST
7 Supply, Installation, Testing and Commissioning of Inverted Tissue Culture Microscope With Image each 1 5,29,620.00 5,29,620.00
Analysis System, Optical System : CFI60 Infinity Optical System, Observation method : Bright Field,
Apodized Phase Contrast Phase Contrast, Emboss Contrast Illumination : High luminescent white LED
illuminator Diascopic illumination (Eco-illumination), Built-in Fly eye lens
(Detailed specification appended separately in technical specification of tender documents)
8 Supply, Installation, Testing and Commissioning of Trinocular Stereozoom Microscope With Digital each 1 6,21,285.00 6,21,285.00
Camera And Image Analysis System And Polarizer & Analyzer Attachment
Optical System : Parallel-optics type zooming system
Total Magnification : 5x - 480x (depending on eyepiece & objective
Zooming Ratio : 8:1
Eyepiece tube inclination : upto 20 degrees
Interpupillary Distance Adj : 48mm - 75mm
(Detailed specification appended separately in technical specification of tender documents)
9 Supply, Installation, Testing and Commissioning of Upright Trinocular Advance Research Microscope each 1 14,56,455.00 14,56,455.00
For Bright Field, Phase Contrast & Epi-Fluorescence Application With Image Analysis System
MICROSCOPE MAIN BODY; FOR MAGNIFICATION 40X-1000X, INFINITY CORRECTED
OPTICAL SYSTEM ANTI FUNGUS TYPE. ALONGWITH FOLLOWING FEATURES:-
EYEPIECE TUBE TRINOCULAR TUBE INCLINED AT 25 degree OR BETTER, F.O.V. 22 MM OR
BETTER, TWO WAYLIGHT PATH DISTRIBUTION i.e 100/0, 0/100.
EYEPIECE LENS 10X (2PCS) WITH DIOPTER ADJUSTMENT (F.O.V. 25MM)
OBJECTIVES: SUITABLE FOR BRIGHT FIELD, PHASE CONTRAST, DIC, FLUORESCENCE
MICROSCOPY APPLICATION. (Detailed specification appended separately in technical specification
of tender documents)
10 Supply, Installation, Testing and Commissioning of Freeze Drier (Lyophilizer), microprocessor each 1 10,61,277.00 10,61,277.00
controlled compact benchtop design with small foot print, Should have 3.5 liter capacity Ice Condenser
and Cooling coil should be made of corrosion resistant SS 316L, system should be capable of removing
2 liters or more water in 24 hours, it should have minimum 1/2 Hp or more, CFC /HCFC Free
refrigeration system to cool collector – 55 Deg C or below at room tem of 25 Deg C. (Detailed
specification appended separately in technical specification of tender documents)
11 Supply, Installation, Testing and Commissioning of Gas Chromatography Microprocessor control GC each 1 26,94,441.75 26,94,441.75
system with one capillary column injection ports and one packed column injection port with flow line
controller and separately two Flame Ionized Detectors (FID) of high sensitivity (detection limit should be
3 pgC/s or better; with temperature range 400 degree C) with separate inlets for both injection ports.
(Detailed specification appended separately in technical specification of tender documents)
12 Supply, Installation, Testing and Commissioning of pH cum Conductivity Meter of Economical, user- each 2 72,822.75 1,45,645.50
friendly and accurate, for routine applications in laboratories For pH and electrical conductivity
measurements, Large, easy-to-read display, Ready indicator let you know when readings are stable
(Detailed specification appended separately in technical specification of tender documents)
13 Supply, Installation, Testing and Commissioning of Liquid Nitrogen cylinders set 1 2,18,468.25 2,18,468.25
(combination of cylinders of 5, 15, 35, 50 L capacity) • Different capacity of liquid nitrogen cylinders, 5 (
2 nos.), 15 ( 2 Nos.), 35 (2 Nos.), 50 L (one), Durable aluminium construction Heavy duty lockable
enclosure offers excellent security, Temperature data-logging monitoring available (Detailed specification
appended separately in technical specification of tender documents)
14 Supply, Installation, Testing and Commissioning of Refrigerated Centrifuge (Bench top) Compact each 2 5,60,175.00 11,20,350.00
design, CE Certified Microprocessor controlled centrifuge
Compatibility : PCR tubes and PCR strips, 1.5/ 2ml tubes, capillary tubes.
Should have both fixed angle (30 ml), plate (96 well plate) and swingout rotor for 1.5/2ml tubes.
Drive: maintenance free brushless drive, Speed Range: ≥ 200 to 15000 RPM. (Detailed specification
appended separately in technical specification of tender documents)
15 Supply, Installation, Testing and Commissioning of Compact design International standarad CE Certified each 2 3,49,549.20 6,99,098.40
Microprocessor controlled centrifuge
Compatibility : PCR tubes and PCR strips, 1.5/ 2ml tubes, capillary tubes.
Should have both fixed angle and swingout rotor for 2ml tubes. Drive: maintenance free brushless drive,
Speed Range: ≥ 200 to 14800 RPM.
(Detailed specification appended separately in technical specification of tender documents)
16 Supply, Installation, Testing and Commissioning of Electrophoresis Vertical And Horizontal with Power each 1 6,99,098.40 6,99,098.40
Supply and electro bolt, Should have a single molded tank with lid and UV Transparent tray with a safety
lid, Should have UV transparent tray of approx. 7 x 10 cm & 7 x 7 cm with at least two slots of combs of
varying thickness (0.75,1.0, 1.5 mm), Gel Tray should have UV Fluorescent ruler for easy viewing of gels
on gel doc, Should have a sample through put of up to 30 samples, at least two combs should be provided,
one each of 8 and 15 wells
(Detailed specification appended separately in technical specification of tender documents)
17 Supply, Installation, Testing and Commissioning of Electronic Balances with different sensitivity each 1 1,45,645.50 1,45,645.50
Automatic internal calibration with built in weight, Easy to read LCD Display with back light
Standard RS 232 C Interface, Based on E.M.F.C. Technology, S.S. Weighing Pan, Level Indicator,
Adjustable Fit, Full tare range up to max. Capacity of the Balance
1. Max Capacity: 220 g, Readability: 0.1mg, Tare range: Full, Repeatability: ±0.1mg
(Detailed specification appended separately in technical specification of tender documents)
18 Supply, Installation, Testing and Commissioning of Zeta sizer cum Zeta potential (Dynamic Light each 1 43,69,365.00 43,69,365.00
Scattering System) PC controlled system with cuvette compatible for the measurement of Size, Zeta
Potential and Molecular weight of dispersed particles/biomolecules in polar and non-polar solvents.
2. Optics must be fully pre-aligned with no user adjustment is required.
3. Should use digital correlator with minimum as low as 25 ns sampling time with minimum 750 physical
channels or better.
(Detailed specification appended separately in technical specification of tender documents)
19 Supply, Installation, Testing and Commissioning of HPLC For analytical as well as semi-preparatory each 1 50,00,000.00 50,00,000.00
purpose with different detection system Analytical cum Semi Prep Binary High Pressure Liquid
Chromatography System,
Solvent System (Integrated Binary Pump)
Flow rate 0.001 to 20.000 mL/min. in 0.001mL/min. increment.
Flow precision: 0.1% RSD
Flow accuracy: +1%
Max operating pressure: 6000psi
(Detailed specification appended separately in technical specification of tender documents)
20 Supply, Installation, Testing and Commissioning of Power Back-up each 4 1,00,000.00 4,00,000.00
(ONLINE UPS--of 5kva ) True On-Line Double Conversion UPS, High Frequency, IGBT Based
Technology, System should have Microprocessor Based Design, Constant Voltage Constant Frequency,
Constant Voltage Constant Charger, LCD Panel / Digital Display, Total Isolation Transformer with
Isolated Pure Sine Wave Output, Wide Input Range, Real Economic Mode / Transfer From Mains, To
Inverter Without Break, Silent Operation Mode Noise <60dBA
(Detailed specification appended separately in technical specification of tender documents)
21 Supply, Installation, Testing and Commissioning of Microwave digester System must be advance, based each 1 26,94,441.75 26,94,441.75
on continuous microwave heating technology and must have provision to control temperature and
pressure simultaneously inside the vessels. The cavity chamber should be made of corrosion resistant
Stainless steel with multilayer fluoropolymer coating for physical protection as well as chemical
resistance and should be less than 8 liters in volume.
(Detailed specification appended separately in technical specification of tender documents)
22 Supply, Installation, Testing and Commissioning of Microtome SEMI AUTOMATIC MICROTOME each 1 10,18,500.00 10,18,500.00
Should be New generation microtome with maintenance free cross roller guide ways which provides
greater stability during sectioning and motorized feed drive.
Should be provided with a imported motor and drives which ensure accurate specimen advance, LCD
screen displays section and trimming thickness number of sections cut
Trimming thickness, sectioning thickness, fast forward and fast backward movement must be controlled
through feather touch keypad.
(Detailed specification appended separately in technical specification of tender documents)
23 Supply, Installation, Testing and Commissioning of Autoclave Semi-automated Microprocessor based each 2 5,77,500.00 11,55,000.00
vertical type, Capacity: 80Lit.
Temp. Range &Accuracy: Room Temp: Approx+50C to 1300C,± 0.50C at121 degree C
Pressure & Gauge: 1.2kgf/cm2 at 121 degree C/2.0kgf/cm2 at 132 degree C, 0~3kgf/cm2
Sterilization mode: Solid-or Liquid-mode
Heating Power/Consumption: 3KW
Timer & Alarm: 60min, Errorstatus & Timer-end
(Detailed specification appended separately in technical specification of tender documents)
24 Supply, Installation, Testing and Commissioning of Horizontal Laminar Flow Cabinet (4x2x2’) (2N0.) set 1 16,80,000.00 16,80,000.00
Horizontal Laminar Flow Cabinet (6x2x2’) (2N0.) total 04 numbers of cabinet 1. Nominal Size approx.: 4
Feet width x 2 feet Height x 2 feet Depth (2 Nos)
2. Nominal Size approx : 6 Feet width x 2 feet Height x 2 feet Depth (2 Nos)
Average Airflow Velocity: Approx 0.5m/s at initial setpoint
Air Volume : Approx 800m³/hr ULPA Filter Typical Efficiency > 99.999% at particle size between 0.1 to
Fluorescent Lamp Intensity at Zero Ambient Approx 1000-1100Lux
(Detailed specification appended separately in technical specification of tender documents)
25 Supply, Installation, Testing and Commissioning of Incubator Shaker (Internal 850x600x450 mm, rpm each 2 5,04,000.00 10,08,000.00
25-400, 5-80 degree C)) x2 No Specification of Stackable Incubator Shaker:
• Compact Size Incubator shaker, should be Stackable and could be used under the bench or on the table.
• Bottom should be shaker with different size of assorted clamp (100ml, 250 ml, 500ml, 1L flask
capacity); on the top there should be two shelves for keeping the petri plates
(Detailed specification appended separately in technical specification of tender documents)
26 Supply, Installation, Testing and Commissioning of Microprocessor based BOD Incubator (240 L, 0-100 each 1 3,36,000.00 3,36,000.00
degree C) Volume : 200-240 Lt., With 4 shelves and maximum capacity for 8 as provision.
Temperature Range : 0 to 100 degree C; Forced Convection Pre-Heat Technology, UV light disinfection.
PID Microprocessor Control , PIN code safe multi-user, Two Temp. display-Actual Temp. Inside and Set
Electro-galvanised steel with white oven-baked epoxy antimicrobial powder-coated finish.
(Detailed specification appended separately in technical specification of tender documents)
27 Supply, Installation, Testing and Commissioning of Ultrasonic Water bath Capacity – 22-25Ltrs; each 1 1,62,750.00 1,62,750.00
Equipped with a timer which can be set for 15 minutes. It can also be set to manual operation up to 1 hour
Main line voltage 230/240V~50/60Hz
Main input power/consumption 180 W
Main input power with heating 355 W
Peak HF Ultrasound Power 360 W
US frequency 40 Khz ± 5% with SWEEP SYSTEM Technology
Liquid drain tube 10x8mm
(Detailed specification appended separately in technical specification of tender documents)
28 Supply, Installation, Testing and Commissioning of Shaking & Heating Bath, each 1 2,43,243.00 2,43,243.00
Bath volume (L / cu ft): 25 / 0.9
Working temperature range (℃ / ℉): Amb. +5 to 100 / Amb. +9 to 212
Temperature stability 1) (±℃ / ℉): 0.2 / 0.36
Shaking system: Motion / Speed range (rpm) Reciprocating / 20 to 180
(Detailed specification appended separately in technical specification of tender documents)
29 Supply, Installation, Testing and Commissioning of Vacuum oven, 316 stainless steel inner chamber each 1 3,33,633.30 3,33,633.30
,easy to clean and maintain, PID Controller with over temperature alarm and timing function .It ensures
precise and reliable control ,also saves more than 40% of heating time, A big dual layer tempered glass
on the door provides good observation, Door adjustment system with silicon door gasket ensures better
vacuity,K F25 Vacuum port, LED Lights on the Door (Detailed specification appended separately in
technical specification of tender documents)
30 Supply, Installation, Testing and Commissioning of Water bath , • Large colorful LCD display. each 1 97,597.50 97,597.50
• Water level sensor shuts down further heating to the tank upon low water volumes.
• Audible and Visual Alarm indicators when water level reaches critical levels.
• 304 stainless steel molded tank.
(Detailed specification appended separately in technical specification of tender documents)
31 Supply, Installation, Testing and Commissioning of Circulating chillers • Microprocessor temperature each 1 2,02,702.50 2,02,702.50
• Audible and visible alarm for temperature and water level.
• R134a refrigerant, compressor.
• With interface to external water bath.
• RS485 connector is option which can connect computer to record the parameters and the variations of
temperature.(option) (Detailed specification appended separately in technical specification of tender
32 Supply, Installation, Testing and Commissioning of Drying Oven, Polished stainless-steel chamber, each 1 2,16,216.00 2,16,216.00
Semicircular arcs at corners for easy cleaning, and the space between the shelves in the chamber is
adjustable, Auto-controller of fan speed to prevent damage to the samples, Large LCD screen to display
more data at same time. Self-check function easy to identify problems.
(Detailed specification appended separately in technical specification of tender documents)
33 Supply, Installation, Testing and Commissioning of Heating Incubator, Polished stainless-steel chamber, each 1 2,16,216.00 2,16,216.00
semicircular arcs at corners for easy cleaning, and the space between the shelves in the Chamber is
Auto-controller of fan speed to prevent damage to the samples, Large LCD screen to display more data at
same time, Self-check function easy to identify problems. (Detailed specification appended separately in
technical specification of tender documents)
34 Supply, Installation, Testing and Commissioning of Orbital Shakers , Colourful LCD display. each 1 2,15,465.25 2,15,465.25
PID microprocessor controls shaking speed, and timing. Smooth start and stop system prevents liquid
spillage. Stainless-steel and easy to clean platform. DC brushless motor provides long term reliability.
Safety alarm and shutdown feature for speeds 10% over set speed.
(Detailed specification appended separately in technical specification of tender documents)
35 Supply, Installation, Testing and Commissioning of Deep freezer each 2 4,20,000.00 8,40,000.00
-20 degC Should be High-efficiency and energy saving Industrial grade energy-saving compressor and
optimized cooling system reduce more than 55% power consumption to achieve -20 °C compared with
Hydrocarbon refrigerant compressor, hydrocarbon refrigerant, completely green and environmental
friendly refrigeration system;
(Detailed specification appended separately in technical specification of tender documents)
36 Supply, Installation, Testing and Commissioning of Refrigerator (Pharma application), each 2 6,51,651.00 13,03,302.00
2-8 deg C, Approx. 400 L, Comes with a microprocessor-based controller
Temperature control ranges between +2 C to +8ºC that can be set freely
Temperature control is precise to 1C
Accurate temperature display precisely to 0.1C decimal level Combined with two exact sensors and an
auto defrost function
(Detailed specification appended separately in technical specification of tender documents)
37 Supply, Installation, Testing and Commissioning of Ultra Low Deep freezer each 1 5,51,250.00 5,51,250.00
-86°C Ultra Low Deep Freezer Cabinet should be upright type model.
Cabinet exterior body should be made with the Galvanized steel with powder coating and interior made
with the stainless steel body. High performance VIP insulation panels to minimize cabinet heat gain and
to improve temperature stability (Detailed specification appended separately in technical specification of
tender documents)
38 Supply, Installation, Testing and Commissioning of Probe sonicator, Power-700 to 750 Watt or More, each 1 6,56,250.00 6,56,250.00
Frequency-20 KHz
Liquid Processing Capacity of System-250 ul to 1 liters or Better
Ultrasonicator should have Automatic tuning and Frequency Control.
(Detailed specification appended separately in technical specification of tender documents)
39 Supply, Installation, Testing and Commissioning of Ice flaking machine Crispy ice flake Microprocessor each 1 4,51,500.00 4,51,500.00
thermostat controlled, High-quality stainless steel shells, anti-corrosive and durable, all-in-one
independent structure.
Storage bin is rust proof with good insulation to protect ice from ambient temperature.
System automatically stops when the bin is full and resumes when ice level reduces below certain level.
Air cooled Refrigeration/condenser system with internal protection against over voltage and over current.
Internal bladders are of fluorine-free bacterial inhibitory-type.
(Detailed specification appended separately in technical specification of tender documents)
40 Supply, Installation, Testing and Commissioning of Flame photometer. The flame photometer should be each 1 4,20,420.00 4,20,420.00
able to detect and display 5 elements simultaneously Na, K, Li, Ca and Barium. The system should come
with built-in filters for all the above 5 elements. The Flame photometer should have Auto ignition feature.
Also, there should be a flame detector installed in the system to monitor to see if the flame has lighted
within a set period, if not, the system should turn off the fuel and sound alarm. (Detailed specification
appended separately in technical specification of tender documents)
41 Supply, Installation, Testing and Commissioning of Magnetic stirrer• Temperature: 20-100°C with each 2 1,41,750.00 2,83,500.00
accuracy of ±5°C
• Heating plate should have ceramic/Kera disc coating.
• Temperature Control: Microcontroller
• Speed range RPM: 100-1400rpm
• Speed Acuuracy :±2
• Stirring capacity,(H2O) : Up to 20 L
• Heating Power: 800 W or better
• External Temperature Sensor: Pt1000
(Detailed specification appended separately in technical specification of tender documents)
42 Supply, Installation, Testing and Commissioning of Plant growth chamber, Volume: Approx. Volume is each 1 10,51,050.00 10,51,050.00
1100 to 1300 liters. Lighting: Four tier of shelves lighted (each tier lightIntensity programmable
minimum 100-150 μmoles/m2/s measured @ 6" from Light Bank. Programming and control of the
lighting is done via single real time controller .
(Detailed specification appended separately in technical specification of tender documents)
43 Supply, Installation, Testing and Commissioning of Automated Kjeldahl Analysis system Micro-Kjeldahl each 1 24,00,000.00 24,00,000.00
The automated nitrogen analyzer should consist of Distillation unit with built in colorimetric titration;
Digester and Scrubber units. The detailed required specification is as under:
A. Digester System
• Tube holding capacity: ≥ Minimum 12 Sample
• Temperature: ambient to 650˚C with Infrared technology.
• Temperature Stability: ± 1°C
• Should have programmable time & temperature ramping and audible alarms.
•Bidder must supply exhaust unit, rack, stand, lid, 24 nos. of digestion tubes ≥ 250 ml. and all other
required accessories for standalone operation of the digester.
(Detailed specification appended separately in technical specification of tender documents)
44 Supply, Installation, Testing and Commissioning of Water Purification System. Water Filtration plant for each 1 9,60,960.00 9,60,960.00
nuclease free water on molecular Grade
For generating ultra pure water Type 1 grade water) from portable tap water, suitable for applications like
Molecular biology ,Chemical Anaylsis ,Pathological ,Chromotographic & General lab applications.
(Detailed specification appended separately in technical specification of tender documents)
45 Supply, Installation, Testing and Commissioning of Portable Photosynthesis System (Infra Red Gas each 1 49,50,000.00 49,50,000.00
Analyzer System)
CO2 Gas Analyzer
• Measurement Range: maximum upto 3000µmol mol-1or better
• Precision: within 0.1 µmol mol-1 at ambient level (Averaging at 400 µmol mol-1).
• Accuracy: Within 1% of reading
H2O Gas Analyzer
• Measurement Range: Maximum upto 75 mmol mol-1 or bettter
• Precision: within 0.01 mmol mol-1 (averaging at 10 mmol mol-1)
• Accuracy: Within 1.5% of reading
(Detailed specification appended separately in technical specification of tender documents)
46 Supply, Installation, Testing and Commissioning of Chlorophyll Fluorometer. each 1 5,25,525.00 5,25,525.00
Saturation intensity:Approx500- 6000 μmols set from 10% to 100%
Saturation light source: Array of red LEDs 660 nm.
Modulated light source: Red about 0.2 to 1.0 μmols.
Detection method: Pulse modulated
Detector and Filter: Pin photodiode withapprox 700-750 nm band pass filter
Test duration:About 0.1 seconds to 1.5 seconds. (Detailed specification appended separately in technical
specification of tender documents)
47 Supply, Installation, Testing and Commissioning of Homogenizer/Tissue Lyser along with accessories. each 1 4,50,450.00 4,50,450.00
The system should offer processing of a wide variety of samples, including animal and plant tissues, hard
tissues like bones, which can he used to disrupted samples to release high-quality DNA, RNA and protein
for subsequent purification and analysis.
(Detailed specification appended separately in technical specification of tender documents)
48 Supply, Installation, Testing and Commissioning of Rotory Vacuum Concentrator • Microprocessor each 1 10,51,050.00 10,51,050.00
based Small foot print light weight vacuum concentrator ( basic system ≤ width 25cm x depth 36cm) with
SS rotor Chamber DNA/RNA, proteins and other biological samples application.
• Availibility of 6x 50 ml tubes matelic rotor and capability to run upto 72 tubes or more 1.5/2ml tube.
(Detailed specification appended separately in technical specification of tender documents)
49 Supply, Installation, Testing and Commissioning of Multi-mode Microplate (ELISA) Reader each 1 4,65,465.00 4,65,465.00
1. Should have minimum wavelength range of 400–750 nm and photometric range of 0.0–3.5 OD
50 Supply, Installation, Testing and Commissioning of Instant Proximate Analysis System each 1 30,03,000.00 30,03,000.00
Instant Analyser based on the Near infra Red Technology with diffuse reflectance for Analysis of
Parameters like Moisture, Protein, Oil, Crude Fibre, Starch, Gluten etc in Oil Seeds – Sunflower,
Soyaseed, Mustard, Mahuva, Til, Copra, Til, Grain – Wheat, Sorghum, Maize, Millet and other
Products. The system should be capable of measuring products Like cereals, Pulses, Milk Powder, Semi
Solid material and Edible Oil. (Detailed specification appended separately in technical specification of
tender documents)
51 Supply, Installation, Testing and Commissioning of Rotary Vaccum Evaporator each 1 17,65,050.00 17,65,050.00
Power supply: 100-240 V
Power consumption: 80—100 W
Frequency : 50-60 Hz
Immersion angle: 10-50 deg.C
Rotation speed: 10-300 RPM
Rotor lift: Motored
Display: LCD or touch screen
Maximum flask capacity : 3 liter
Power consumption of Heating bath and its base: 1200-1500W
Temperature range of heating bath up to 200 deg.C
Heating bath capacity – 4-5 liter
(Detailed specification appended separately in technical specification of tender documents)
52 Supply, Installation, Testing and Commissioning of MS Field Distillation Unit capacity 2000 l each 1 6,27,900.00 6,27,900.00
Flange Type unit consist of MS grid, MS Swing system, MS Chimney with condenser-shell and tube
type, shell made of MS fitted with SS 304 tube Receiver made of SS304Components-condenser unit,
condenser, condenser stand, receivers. The unit with all installation along with masonry and plumbing
53 Oil expeller of following minimum specification a. Capacity 6-6 tons per 24 hours each 1 4,50,450.00 4,50,450.00
b. Single stage cooker c. Horizentally fitted chamber
d. Case hardened worm assembly e. Expeller motor capacity 20HP
f. Mild steel helical gear g. Double reduction gearbox
h. Steel fabrication chabmer i. Cast iron body
Minimum overall dimension 2900x960x2150 mm
54 Supply, Installation, Testing and Commissioning of Ride on Sweeping cum Mopping machine each 1 8,94,066.11 8,94,066.11
(Detailed specification appended separately in technical specification of tender documents)
55 Supply, Installation, Testing and Commissioning of Hydraulic tractor linked Broom (Sweeper) driven by set 1 1,78,500.00 1,78,500.00
Hydraulic Motor (Excluding cost of tractor)
(Detailed specification appended separately in technical specification of tender documents)
56 Supply, Installation, Testing and Commissioning of Manual floor cleaning machine (Detailed set 1 1,32,518.01 1,32,518.01
specification appended separately in technical specification of tender documents)
57 Supply of Aluminium Self Supported sliding Extension Ladder of 36 foot height set 1 25,576.49 25,576.49
58 Supply of Aluminium Wall Supported Extension Ladder set 2 7,163.14 14,326.27
59 Supply of Tower ladder ofAluminium D type locking system from 45 degree to 90 degree both sides set 1 3,95,937.20 3,95,937.20
tower ladder (ladder and scaffolding)
60 Integrated Library RFID System for Library with 2 year warranty includes: Job 1 41,12,514.00 41,12,514.00
a. RFID tags for books and RLBCAU logo: 3000 nos
b. Electromagnetic (EM) security strips: 3000 nos
c. Staff workstation hybrid with branded desktop 01 nos
d. Hybrid self check in and check out Kisok (The unit should work for RFID, EM and Barcode) 01 nos
e. Library EM Security Gate 01 nos
f. Shelf management system/portable handheld RFID Reader with Antenna
g.Smart card printer 01 set
h. RFID member smart cards: 1000 nos
i. Server system (for KOHA, UBUNTU certified
j. Installation and configuration of KOHA latest version with Linux operating system (Multiple user and
Branch library handling) and SIP2 protocol integration and making system and hardware functional in all
Item include 2 years warranty and maintenance cost complete as per specification and direction of
Engineer-in-charge/RLBCAU
Total cost 651,34,474.15
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NITreequipment.pdf
Tender Document
LOMequipment.pdf
Tender Document
IPequipment.pdf
Tender Document
SCCreequipment.pdf
Tender Document
Technicalspecequipment.pdf
Tender Document
BOQequipment.pdf
Tender Document
GCCContracting2019withAmendment1to9.pdf
Tender Document
corrigendum-365-Corrigendum01.pdf
pdf • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .