GEMC-511687705514991
Awarded to SUN INDIA FIRE SAFETY SYSTEMS
₹14.0 L
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| fire proximity suit | PYROTEK 1879028 | - | 28 NOS | ₹49,830 | 1,395,240 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14.0 LQualified Make: pyrotek
Model: PYROTEK 1879028 211 SANGAM APPARTMENT SECTOR 24 POCKET 24 ROHINI NORTH WEST DELHI DELHI 110085 | NORTH WEST DELHI | DELHI | 110085 | Make: pyrotek
Model: PYROTEK 1879028 | ₹14.0 L | L1 | Qualified |
| 2 | L2₹14.4 L+₹47,320 (3.39%)Qualified Make: System 5S
Model: System 5S Protecsafe Large size 105 NYNIAPPA NAICKEN STREET FLOWER BAZZAR CHENNAI 600003 CHENNAI TAMIL NADU 600003 | CHENNAI | TAMIL NADU | 600003 | Make: System 5S
Model: System 5S Protecsafe Large size | ₹14.4 L+₹47,320 (3.39%) | L2 | Qualified |
| 3 | Disqualified Make: NA
Model: FIRE FIGHTING PROXIMITY SUIT 203 MONT VERT VIVANT CHS TLD SHANKAE KALATE ROAD WAKAD PUNE MAHARASHTRA 411057 | PUNE | MAHARASHTRA | 411057 | Make: NA
Model: FIRE FIGHTING PROXIMITY SUIT | - | - | Disqualified |
| 4 | Disqualified Make: NOMEX
Model: System 5 S & Protecsafe H 77 UPSIDC M G ROAD INDUSTRIAL AREA MASSORI HAPUR UTTAR PRADESH 201001 H 77 UPSIDC INDUSTRIAL AREA GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | Make: NOMEX
Model: System 5 S & Protecsafe | - | - | Disqualified |
| 5 | Disqualified Make: System 5S
Model: System 5 S & Protecsafe C 24 GROUND FLOOR PATPARGANJ INDUSTRIAL AREA PATPARGANJ NEAR HDFC BANK EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: System 5S
Model: System 5 S & Protecsafe | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
14 Aug 2018, 3:00 pmClosed
fire proximity suit Fire Proximity Suit ( 28 ) Technical Specifications Specification Specification Name Values Allowed Values Genric Conformity to EN Standard fire proximity suit coat trouser to en 469 2005 fireman helmet to en 443 2008 type b fireman gloves to en 659 2008 fireman boots to en 15090 2012 and antiflash hood to en 13911 2004 also with ce marking for all items EN 13911:2004 for Antiflash Hood
en 15090 2012 for fireman boots
en 443 2008 type b for fireman helmet
en 469 2005 level 2 with latest amendments for fire proximity suit coat and trouser suitable for class iii fire defined as radiant heat and pocket of flames
en 659 2008 for fireman gloves
fire proximity suit coat trouser to en 469 2005 fireman helmet to en 443 2008 type b fireman gloves to en 659 2008 fireman boots to en 15090 2012 and antiflash hood to en 13911 2004 also with ce marking for all items Item Descriptions complete set cosisting fire proximity suit coat trouser fireman helmet type b fireman gloves fireman boots antiflash complete set cosisting fire proximity suit coat trouser fireman helmet type b fireman gloves fireman boots antiflash 1/6 hood hood Educational Instructions (Supplier Has To Educate to End user) "The items are to be used at a close proximity to the Fire never exceeding a closeness of more than 1 meter from the Fire. They are NEVER to BE USED for FIRE ENTRY Purpose. How to use the fire suit about wearing and removing. How maintain the fire suit. Limitation of use of fire suit according to the user manual provided along with the fire suit Fire suit needs to be Inspected every time after use to identify if it suitable for deployment. The reason is that after Exposure to every Fire Accident the Fire Fighting suit may get damaged and hence
this may be render the Fire Proximity suit unsutiable for deployment till it is repaired . Wash care maintenance of Fire suit is strongly recommended. Ideally after every six months the Fire Suits should be sent back to the manufacture for Wash Care and Maintenance. This will ensure that the Fire Proximity suits are Clean and suitable for deployment after exposure to previous Fire Fighting activity. The Fire Fighting suits normally are recommended with a shelf life of 5 years from the date of manufacture and ideally should be replaced after this period. " - Constructional Fire Proximity suit Large (L) ( Suitable for - 2/6 (Coat and Trouser) size person of height 164-176 cm
Chest Girth 96-104 cm
Waist Girth 92-100 cm) Suit colour Navy Blue - Suit Fabric the fabric namely nomex kevlar or equivalent shall be used for manufacture of the suit the garment manufactures have to furnish the genuinity certificate test certificates issued by m s du pont or the manufacturer of the fibre for the fabric - Generic Fibre of suit outer shell layer contains fibre composition of para aramide meta aramide 2 antistatic etc gsm 190 minimum or para amarmide polybenzimdiazole 2 anti static gsm 190 minimum middle layer contains fibre composition of meta aramide para aramide ptfe - Fireman Helmet (Type B) sizes shall be as per clause 5 of Helment Adjustment of EN:443-2008
Bicomponent membrane
Lining Fabric contains fibre composition of:-Blend of Meta aramide ( or ) Blend of Modarylic yes - Fireman Gloves size NA - Fireman boot size NA - Firehood shall be manufactured in various sizes or be sufficiently elastic to be compitable with various head sizes and shape Sufficiently elastic to be compitable with various head sizes and shape - Labelling Each set must be having LABLE attached and Instruction on the - 3/6 label. Improper process could modify the clothing features and protective levels
Keep clothing dry and clean in suitable place at ambient temperature and humidity
Do not expose it to heat or cold surface and to repair the clothing we recommend to use only materials like the ones used for the manufacturing of the clothing . No other materials must be used and repairs must be carried out only by an experienced staff or directly by the manufacturer .The clothing has been planned with high quality components . In spite of this protective features can be subject to degradation in the long run as a result of the condition of working place. Therefore it is not possible to fix the durability of the clothing but in any case
following exposure to a risk that might damage whatever components
the time frame is undecided. Certification Approval All the Items (components) should be approved to relevant EN standards and should be supported with both "EC Type Examination Certificate"as per Article 10 & "EC Quality System certificate" as per Article 11 A or 11B as per EEC guidelines individually. - Technical manual comprising of servicing Yes - 4/6 details shall be supplied with system The firm shall furnish manufacturers ™ test certificate for the fabric
major components and main item on the basis of the test performed on the representative samples Yes - Availability of complete & satisfactory test Report from Central govt/NABL/ILAC accredited laboratory for individual components (as applicable) conforming to relevant EN standard Yes - Test report No. - - Test Report date - - Name of lab where test conducted BTTG UK - Availabiility of CE certificate for individual item (component) genuinity of which to be verified from the certification agency Yes - Copy of test report and certifications to be furnished to the buyer on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Joginder Kaur Walia 160017
Municipal Corporation
New Deluxe Building
Sector 17 Chandigarh 28 60
382232
GEM/2018/B/54119
GeM Contract
fire proximity suit
GeM Contract
60 days
Chandigarh; Chandigarh
PRODUCT
Awarded to SUN INDIA FIRE SAFETY SYSTEMS
₹14.0 L
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| fire proximity suit | PYROTEK 1879028 | - | 28 NOS | ₹49,830 | 1,395,240 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| fire proximity suit Fire Proximity Suit ( 28 ) Technical Specifications Specification Specification Name Values Allowed Values Genric Conformity to EN Standard fire proximity suit coat trouser to en 469 2005 fireman helmet to en 443 2008 type b fireman gloves to en 659 2008 fireman boots to en 15090 2012 and antiflash hood to en 13911 2004 also with ce marking for all items EN 13911:2004 for Antiflash Hood | - | - | - |
| en 15090 2012 for fireman boots | - | - | - |
| en 443 2008 type b for fireman helmet | - | - | - |
| en 469 2005 level 2 with latest amendments for fire proximity suit coat and trouser suitable for class iii fire defined as radiant heat and pocket of flames | - | - | - |
| en 659 2008 for fireman gloves | - | - | - |
| fire proximity suit coat trouser to en 469 2005 fireman helmet to en 443 2008 type b fireman gloves to en 659 2008 fireman boots to en 15090 2012 and antiflash hood to en 13911 2004 also with ce marking for all items Item Descriptions complete set cosisting fire proximity suit coat trouser fireman helmet type b fireman gloves fireman boots antiflash complete set cosisting fire proximity suit coat trouser fireman helmet type b fireman gloves fireman boots antiflash 1/6 hood hood Educational Instructions (Supplier Has To Educate to End user) "The items are to be used at a close proximity to the Fire never exceeding a closeness of more than 1 meter from the Fire. They are NEVER to BE USED for FIRE ENTRY Purpose. How to use the fire suit about wearing and removing. How maintain the fire suit. Limitation of use of fire suit according to the user manual provided along with the fire suit Fire suit needs to be Inspected every time after use to identify if it suitable for deployment. The reason is that after Exposure to every Fire Accident the Fire Fighting suit may get damaged and hence | - | - | - |
| this may be render the Fire Proximity suit unsutiable for deployment till it is repaired . Wash care maintenance of Fire suit is strongly recommended. Ideally after every six months the Fire Suits should be sent back to the manufacture for Wash Care and Maintenance. This will ensure that the Fire Proximity suits are Clean and suitable for deployment after exposure to previous Fire Fighting activity. The Fire Fighting suits normally are recommended with a shelf life of 5 years from the date of manufacture and ideally should be replaced after this period. " - Constructional Fire Proximity suit Large (L) ( Suitable for - 2/6 (Coat and Trouser) size person of height 164-176 cm | - | - | - |
| Chest Girth 96-104 cm | - | - | - |
| Waist Girth 92-100 cm) Suit colour Navy Blue - Suit Fabric the fabric namely nomex kevlar or equivalent shall be used for manufacture of the suit the garment manufactures have to furnish the genuinity certificate test certificates issued by m s du pont or the manufacturer of the fibre for the fabric - Generic Fibre of suit outer shell layer contains fibre composition of para aramide meta aramide 2 antistatic etc gsm 190 minimum or para amarmide polybenzimdiazole 2 anti static gsm 190 minimum middle layer contains fibre composition of meta aramide para aramide ptfe - Fireman Helmet (Type B) sizes shall be as per clause 5 of Helment Adjustment of EN:443-2008 | - | - | - |
| Bicomponent membrane | - | - | - |
| Lining Fabric contains fibre composition of:-Blend of Meta aramide ( or ) Blend of Modarylic yes - Fireman Gloves size NA - Fireman boot size NA - Firehood shall be manufactured in various sizes or be sufficiently elastic to be compitable with various head sizes and shape Sufficiently elastic to be compitable with various head sizes and shape - Labelling Each set must be having LABLE attached and Instruction on the - 3/6 label. Improper process could modify the clothing features and protective levels | - | - | - |
| Keep clothing dry and clean in suitable place at ambient temperature and humidity | - | - | - |
| Do not expose it to heat or cold surface and to repair the clothing we recommend to use only materials like the ones used for the manufacturing of the clothing . No other materials must be used and repairs must be carried out only by an experienced staff or directly by the manufacturer .The clothing has been planned with high quality components . In spite of this protective features can be subject to degradation in the long run as a result of the condition of working place. Therefore it is not possible to fix the durability of the clothing but in any case | - | - | - |
| following exposure to a risk that might damage whatever components | - | - | - |
| the time frame is undecided. Certification Approval All the Items (components) should be approved to relevant EN standards and should be supported with both "EC Type Examination Certificate"as per Article 10 & "EC Quality System certificate" as per Article 11 A or 11B as per EEC guidelines individually. - Technical manual comprising of servicing Yes - 4/6 details shall be supplied with system The firm shall furnish manufacturers ™ test certificate for the fabric | - | - | - |
| major components and main item on the basis of the test performed on the representative samples Yes - Availability of complete & satisfactory test Report from Central govt/NABL/ILAC accredited laboratory for individual components (as applicable) conforming to relevant EN standard Yes - Test report No. - - Test Report date - - Name of lab where test conducted BTTG UK - Availabiility of CE certificate for individual item (component) genuinity of which to be verified from the certification agency Yes - Copy of test report and certifications to be furnished to the buyer on demand Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Joginder Kaur Walia 160017 | - | - | - |
| Municipal Corporation | - | - | - |
| New Deluxe Building | - | - | - |
| Sector 17 Chandigarh 28 60 | - | - | - |
Exempted
27 Sept 2018
25 Jul 2018
contract_GEMC-511687705514991.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_382232.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .