| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAccepted-AOC AZARA BHARALIPARA NEAR AZARA PUBLIC HALL GUWAHATI 781017 ASSAM | KAMRUP METRO | ASSAM | 781017 | ₹1.4 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.4 Cr+₹1.9 L (1.39%)Rejected-AOC NO 3 WD BUILDING JP AGARWALLA ROAD BHARALUMUKH KAMRUP ASSAM 781009 UDYAM AS 03 0009483 | KAMRUP METRO | ASSAM | 781009 | ₹1.4 Cr+₹1.9 L (1.39%) | L2 | Rejected-AOC L2 |
| 3 | L3₹1.4 Cr+₹6.8 L (5.00%)Rejected-AOC | ₹1.4 Cr+₹6.8 L (5.00%) | L3 | Rejected-AOC L3 |
| 4 | L4₹1.6 Cr+₹22.7 L (16.6%)Rejected-AOC OPP BSF GATE NO 3 AZARA GUWAHATI 17 ASSAM | ₹1.6 Cr+₹22.7 L (16.6%) | L4 | Rejected-AOC L4 |
| 5 | L5₹1.7 Cr+₹28.3 L (20.7%)Rejected-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | ₹1.7 Cr+₹28.3 L (20.7%) | L5 | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
19 Sept 2023, 6:00 pmClosed
CWE (AF) Borjhar
HQ CWE (AF) Borjhar, Military Engineer Services, PO - Borjhar Airport, Guwahati (Assam) - 781015 Tele 0361 2841626
PROVN OF COMMERCIAL POWER SUPPLY FOR AF STN BORJHAR UNDER GE (AF) BORJHAR (3rd CALL)
2023_MES_595029_3
CWE(AF)/BOR/TOKEN-02 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Borjhar
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (AF) Borjhar
₹2.2 L
Yes
11 Oct 2023
29 Aug 2023
21 Sept 2023
29 Aug 2023
19 Sept 2023
1 Sept 2023
Amount
Surface dreesing in soft/loose soil n.exc 15cm deep complete all as specified and directed.
Excavating over areas in soft/loose soil n. exc 1.5 m deep and getting out in foundation complete all as specified and directed.
Excavating over areas in soft/loose soil exc 1.5m and n exc 3 m deep and getting out in foundation complete all as specified and directed.
M&L for PCC 1:4:8 type D-2, using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
Mild steel bars (TMT bars) 10 mm and above dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
Mild steel bars (TMT bars) 6 mm to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
All as per item No 06 above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
M&L for Formwork to flat sides of concrete foundations, footings, bases of columns, sides and soffits (if any) of foundation and plinth beams and similar work, vertical or to batter with fair finished surface complete all specified and directed.
M&L for formwork to sides of pillars, posts, struts, piers, columns of shape square, rectangular or polygonal with fair finished surfaces complete all specified and directed.
M&L for Formwork to edges of concrete flats, breaks in floors, window cills, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizon?tal or sloping and similar work exc 10cm but n exc 20cm wide with fair finished surfaces complete all specified and directed.
All as per item No 10 above but exc 5cm and n exc 10cm wide with fair finished surfaces complete all as specified and directed.
M&L for Formwork to flat soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) with fair finished surfaces complete all as specified and directed.
M&L for Formwork to flat sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. with fair finished surfaces complete all as specified and directed.
M&L for Formwork to flat soffit surfaces of chajjas, troughs and similar items in?cluding edges With fair finished surfaces complete all as specified and directed.
M&L for RCC M-25 design mix (using 20mm graded aggegate) as in Foundations, including rafts, footings, plinth beams; etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M&L RCC M-25 design mix (using 20mm graded aggegate) nominal mix as in Columns, pillars etc complete all as specified and directed.
M&L RCC M-25 design mix (using 20mm graded aggegate) nominal mix as in Slabs supported on walls, beams and columns in floors, roofs, etc. complete all as specified and directed.
M&L RCC 1:2:4, type B1 (using 20mm graded aggegate) nominal mix as Beams, cantilevers, lintels over 1.5m span etc. complete all as specified and directed.
M&L RCC 1:2:4, type B1 (using 20mm graded aggegate) nominal mix as chajjas complete all as specified and directed by.
Returning, filling in, soft/loose soil in layers not excceding 25 cm thick, watering and well ramming complete all as specified and directed.
Removing excavated materials (soils) to a distance not exc 50 m and depositing where directed at a level not exc 1.50 m above the starting point, complete all as specified and as directed.
M&L for Treating the bottom and sides of excavation @ 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for Treating the backfill in contact with foundation @ 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) and treating junction of wall and floor complete all as specified and directed.
M&L for Treating the top surface of filled earth @ 5 litres of emulsion per square metre of surface complete all as specified and directed .
M&L for Treating the soil under plinth protection @ 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for Treating the soil along with external perimeter of building @ 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for PCC 1:5:10 type E-2, using 40 mm graded stone aggregate as in foundation of Brick wall complete all as specified and directed.
M&L for brickwork with subclass 'B' Bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L for soil filling including raising (or lowering) earth, spreading in layers n exc 300mm thick watering, ramming and finishing to required size, shape, etc n exc 1.5m high from base complete all as specified & directed. Note- Approved soil to be bring to the site from outside MOD Land and cost for the same shall be deemed to be inclusive of quoted unit rate.
M&L for approved earth filling under floors or in foundations including watering and consolidation complete all as specified and directed. (Note: Compacted thickness shall be measured and paid)
M&L for 150 micron Polythene film, Black, laid in floors complete all as specified and directed.
M&L 75mm thick PCC 1:4:8, type D-2, (using 40mm graded aggregate), as in sub-floors, sub-bases, etc. finishing surfaces of concrete even and rough to receive the topping layer complete all as specified and directed.
ML for 25mm thick PCC type B-1, 1:2:4 (using 20mm graded aggregate) as in floor, subbase etc. complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1:4 to other than fair faces of brick or concrete surfaces with WPC (as per manufacturer instruction) finished even and smooth without using extra cement complete all as specified and directed. Note: WPC shall be measured and paid separately. 10mm groove shall be provided at the junction of brick and RCC work as directed.
M&L for rendering 10 mm thick in cement mortar 1:6 to fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. Note: 10mm groove shall be provided at the junction of brick and RCC work as directed.
Supply only WPC (ISI Marked) complete all as specified and directed.
M&L for rendering 5mm thick on concrete surfaces in CM 1:3 on ceiling, finished even and smooth complete all as specified and directed.
M&L for Steel rolling shutters with 1mm thick laths, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as directed, push pull gear operated type with bevel gear box and crank handle complete all as specified and directed.
S&F for Safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed.
S&F for Steel windows with side hung shutters including projecting type hinges with chromium plated steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S&F for Mild Steel works as in bands straps, hold fasts etc, conforming to IS-2062-2006 (Fe-290), embedded portion duly painted with bituminious paint and sanded, complete all as specified and directed.
M&L for Preparing surface of iron and treating small articles such as stop, covers, gully grating, holdfasts, end of posts, area exc 0.1 Sqm each complete all as specified and directed.
M & L for PCC type B1 (1:2:4) using 20mm grades aggregate as in copings, bed plates, fixing of hold fasts and other similar works and the like incl weathering, slightly rounded or chamfered angles and throating as directed incl use and waste of necessary form work complete all as specified and directed.
S&F of 3 mm thick sheet glass of ordinary quality and glazing with oil putty or steel frame in square n exe .5 sqm each pane complete all as specified and directed.
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staplesfor complete all as specifed and directed.
M&L for Machine cut kota stone slab flooring 18-20 mm thick over and including 20mm thick cement screed bed in CM (1:6) laid for floor finishes and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for Kota stone slab 18-20 mm thick in riser of steps, skirting, dado and pillar laid over and including 12 mm thick cement screed bed in CM (1:4) and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for non skid ceramic coloured tile 7 to 8mm thick (square/rectangular) area of each tiles exceeing 0.06 sqm but not exceeding 0.11 sqm in floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed in CM 1:6 complete all as specified and directed
M&L for Glazed ceramic coloured tiles in verticle surface of size 350x250x7 / 450x200x7mm thick over and including 10 mm thick rendering in CM (1:4) and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed. Note - Rates includes necessary scafolding required for execution of work
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. Note - Rates includes necessary scafolding required for execution of work.
M & L for preparation of new undecorated plastered/concrete surface of wall/roof and applying of two coat of weather proof Acrylic emulsion paint (exterior grade) in camoflauge pattern over a coat of weather coat primer including nesessary scafolding all as specified and as directed.
M & L for cleaning of all loose dirt & dust from roof surfaces and applying roof treatment as under:- (a) 10 mm thick plastering in CM (1:4) using 100% coarse sand on roof/ parapet walls with WPC @ 3% BY WEIGHT OF CEMENT (b) Applying coat of bituminous primer @ 0.40 litre/ Sqm on prepared surfaces and allow to dry (c) Applying a coat of hot blown bitumen 85/25 grade @ 1.20 Kgs/ Sqm over primer (d) Supply and laying of 3mm thick (minimum) polymeric water proofing membrance weighting not less than 3.6 kg/ Sqm, Black, finish reinforced with non woven polyster matt with help of torching with proplane or abutance gas using toech with minimum 75 mm side overlap and 100 mm end overlap as per manufacturar instruction (e) Applying a tack coat of hot blown bitumin of grade 85/25 @ 10.20 Kgs / Sqm (f) Alluminium paint over treated surface applied as per manufacturer instruction complete all as specified and as directed.
M&L for 50mm thick PCC Type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection, over and including 100mm thick hardcore of broken stone of gauge n.exc 63mm, spread, levelled in layers n.exc 15 cm thick watered and rammed over rammed earth complete all as specified and directed.
M&L for painting two coats with synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10cm width or girth including preparation of surfaces complete all as specified and directed.
S&F 110 mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to wall/floor with and including clamps complete all as specified and directed.
S&F 110 mm bore PVC (SWR) bends any radius, provided with access door complete all as specified and directed.
S & F PVC (SWR) junction single (single T) equal or unequal 110mm bore, provided with access door complete all as specified and directed.
S&F CPVC pipes of 16mm outer dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors etc. is jointed with CPVC solvent cement only (Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc) including all fitting and fixtures complete all as specified and directed
All as per item No 60 above but 20 mm outer dia complete all as specified and as directed.
S&F Vitreous China wash basin, white, flat back, size 550mm x 400 mm with & including a pair of cast iron brakets embedded in PCC (1:3:6) type C-1 (using 20mm graded stone aggregate) blocks of size 10x7.5x15cm, and 32 mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed, ( excluding tap ) including PVC Waste coupling of PTMT 32mm dia (half or full threaded) Minimum weight 45gms, washers and Brass chromium plated bottle traps for wash basins with inlet and outlet screwed for pipe or connections including necessary packing, union and cap and fixed complete as specified and directed.
S&F Bib taps (15mm dia of bore), cast copper alloy with capstan heads, fancy type chromium plated ,screwed down, screwed for iron pipe or for brass ferrule and fixed includng neccesary fittings complete all as specified and directed.
S&F Pillar taps (15mm dia of bore) , cast copper alloy, with capstan heads, fancy type chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed brass chromium Concealed angle stop cock with wall flange of 15mm dia capastan head including neccesary fittings complete all specified and directed .
S&F Stop valves( 15 mm dia of bore), cast copper alloy, fancy type Chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified and directed.
S&F 10 ltr capacity PVC low level flushing cistern, valveless, duel symphonic action type, white, with inlet ball valve, float and handle including brackeet and 32mm dia flush pipe of polyethylene of low or high density for low level cistern complete all as specified and directed.
S&F viterous china wash down water closet pan (pedestal pattern) white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap conncetion to drain , flush pipe ,anti sypohonage pipe and fixing arrangement with fixing bolts,etc including making good to the disturbed portion of floor in cm (1:2:4) type B-0 (using 12.5mm graded stone aggregate) with plastic wc seat cover (white)for closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device of complete all as specified and directed.
S&F CP Health Faucet 8 mm dia with 1 meter long Easy flex tube and wall hook with NRV (black flow preventor) make - Jaguar Cat No: ALD CHR - 583) complete all as specified and directed.
M&L for concrete bed to drain pipes for 150mm bore SGSW/PVC SWR drain pipe in cement concrete 1:4:8 type D-2, using 40 mm graded stone aggregate including packing under and haunching against the sides of pipes in foul smell condition complete all as specifed and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5 mm wood grain printed PVC sheet reinforced with MS square tube and edgeswill be painted to match will printed sheet fixed in opening as per specification & drawings complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing complete, all as specified & directed.
S & F 500 liters rotaional moulded polyethylene water storage tank, double layered (cylindrical vertical with closed top cover) as per IS-12701-1996 and PTMT 20mm ball valves/ float valve high pressure with epoxy aluminium rod and high density plastic ball screwed for iron pipe and fixed (minimum weight 20mm - 210 gms), hoisted and fixed in position including necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc, complete as specified in SSR Part-I complete all as directed.
S&F in repairs 20 mm dia gun metal, globe or gate valve, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F MS Plates (plain or chequered), channels for ducts, Fe-290 (Gde E?165), square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and directed.
S&F Mild Steel Butt hinges, heavy weight, cold rolled, of size 75 mm complete all as specified and directed.
S&F Aluminium handle, cast type anodized size of handle 100 mm complete all as specified and as directed.
S&F Aluminium anodized, barrel tower bolt of extruded section, length of bolt 100 mm complete all as specified and as directed.
M&L for point wiring for light point with 1.5 Sqmm PVC FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable in and including in medium grade PVC concealed conduit of size not less than 25 sqmm dia suitable as per site reqmt, ISI marked with all accessories such as tee, bend, joint cover etc round / square blocks at junctions etc, screws, gutti / roul plugs PVC all as per site requirements including plastic terminal boxes for mounting of switches/ sockets/regulator etc and PVC FRLS insulated & unsheathed 1100 volt grade copper conductor, stranded 1.5 sqmm. cable as continuous earth lead connected to common earth dolly complete all as specified and colour coding of cables such as Phase - Red, Neutral – Black, and Earth – Green.
All as per item No. 80 above but with One socket outlet 5 Amps controlled by one switch on independent board complete all as specified and as directed.
All as per item No. 80 above but 3 pin 15 Amp socket outlet with 4 sqmm PVC insulated copper cable and 2.5 sqmm PVC insulated copper cable for continuous earth continity conductorall as specified and directed.
S & F Switch piano flush type single pole one way 5 amps complete all as specified and as directed.
Supply and fixing Socket outlet 5 pin 5 Amps flush type complete all as specified and as directed.
S &F Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal complete all as specified and as directed.
Supply and fixing ceiling rose surface bakelite 3 terminals complete all as specified and as directed.
S&F surface mounted batten type LED luminaires 20 W, 220V AC, 50 Hz IP 20 with aluminium extruded housing, polycorbonate diffuser & end Caps, minimum efficacy 100 lumens/watt with 120 degree angle, CCT 6500, CRI > 80 power factor >0.9, IP 20 surge protection 4.0 KV, THD< 20% integal electronic driver with short circuit protection and open circuit protection, surg voltage protection complete all as specified and directed.
S&F surface mounted batten type LED luminaires 10 W ,220 V AC ,50 Hz IP 20 with aluminium extruded housing ,polycorbonae diffuser & end Caps ,minimum efficacy 100 lumens/watt with 120 degree angle ,CCT 6500, CRI > 80 power factor >0.9 ,IP 20 surge protection 4.0 KV, THD< 20% integal electronic driver with short circuit protection and open circuit protection ,surg voltage protection complete all as specified and directed.
S &F LED street light fitting 25 Watt 230 volt AC outdoor type with high pressur die cast aluminium hosing and heat resistant complete with driver ,lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protectioncomplete including ,epoxy black powder coated sheet steel housing body with complete epoxy white powder coated CRCA sheet steel gear tray,clear acrylic cover AL reflector & assocessaries complete all as specified and as directed.
Fabricate, supply & fix 40mm dia GI pipe bracket, 1.5m long including 2 set of clamps made out of 30x5mm MS flat & fixed with anchor bolt suitable for 1x25 W security light fitting complete all as specified and as directed.
Supply & fix Exhaust fan IP-55 & ISI marked steel body AC Single phase 230 volt of size 300 mm sweep heavy duty with copper windings complete including blades and frame and louvers / flip cover complete including making hole in existing wall and finshing with cement mortar (1:4) of 15 mm thick plaster work on brick surface /concrete surface /stone surface all as specified and directed. Note : Louvers/flip cover of exhaust fan made with 0.5 mm thick sheet in square /round shape (Fan should be )
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator step type (Anchor Penta ,colour-Ivory) and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete all as specified and as directed.
Supply and fix sheet metal enclosure MCB SPN distribution board, 8 way, Double door with IP-43 protection single phase 240 volts, including suitable size copper bus bar and neutral link fixed flush concealed in wall including taking out old DB's and chases wall for fixing DB and making good distributed wall/surfaces to match with existing specification complete all as specified and as directed.
Supply and fix 'B' series MCB SPN 32 amps, 230 volts, 50Hz complete all as specified and as directed.
Supply and fix 'B' series MCB SP 6 to32 amps, 230 volts, 50Hz complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mm dia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm aluminium flat including earthing pit, charcoal common salt, Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe, G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate, PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-2010 (part-I)
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 m depth and getting out in soft /loose soil complete all as directed.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr depth not more than 3 Mtr and getting out in soft/loose soil for lying of cable etc complete all as specified and directed.
Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cm in depth complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed.
Supply and laying old size sub class 'B' bricks well burnt, best quality locally available laid flat with width equal to length of the brick in trenches over sand cushioning for UG cable protection complete all as specified and directed
M&L for tubes 80 mm bore light grade galvnized with all fittings laid in trenches/wall/ pole through MS flat (25x3 mm) nut bolts &washers(where ever required) of proper sizes for protection cabls complete all as specified and directed by Engr-in-charge.
M&L for tubes 50 mm bore light grade galvnized with all fittings laid in trenches/wall/ pole through MS flat (25x3 mm) nut bolts &washers(where ever required) of proper sizes for protection cabls complete all as specified and directed by Engr-in-charge.
M&L for boring under roads without disturbing the top surface of the road for throughing the cable complete all as specified and directed.
Supply, laying, jointing and testing of electric power cable (HT), heavy duty 11KV (E) grade, XLPE insulated, screened, bedded, galvanised steel strip or wire armoured with aluminium conductor of cross sectional area of 95 sqmm, 3 core, laid in trenches/cable duct complete all as specified and directed. Note: Total quantity of cable shall be in single drum.
Supply and laying heavy duty armoured LT underground cable 1100 V grade XLPE insulated,PVC sheathed multi stranded aluminium cable of sizes 150 Sqmm 3.5 core in pipe/trenches/cable duct/ fixed on wall by proper size of shaped GI clamps with nut bolts etc and making good the disturbed surfaces by cement mortor/painting to match the existing, connecting with all accessories lugs and glands, complete all as specified and directed.
All as per item No 107 above but of cable size 120 sqmm 3.5 core complete all as specified and directed.
All as per item No 107 above but of cable size 35 sqmm 3.5 core complete all as specified and directed.
All as per item No 107 above but of cable size 6 sqmm 2 core complete all as specified and directed.
Supply and installation of 160 KVA Isolation transformer ,three phase, 50 Hz,indoor type, copper wound,oil cooled,class of insulation A, metallic body duly powder coated designed for input Voltage range 415, +5% and output voltage range 415 +5%,and the rate of correction of voltage shall not be less than 6 V/S between phase and neutralratio1:1,Vector groop:Dyn 11, Delta, star with first filling of transformer oil of requisite dielectric strength up to level efficiency more than 95%, separate netutral bushing shall be brought for earthing, Potential deference between neutral to earth less than one volt with all standard fittings like digital temperature meter ,adequate number of cooling radiatores, lifting hooks one set, Earthing terminal two nos complete with Over load/short circuit protection .Testing as per BIS 9815 and 2026. Note:- Contractor should arrange factory inspection of Isolation Transformer and precommissioning testing at site. Cost for arrangement of inspection and on site testing are deemed to be included in the quoted rate.
Supply and installation of 75 KVA Isolation transformer ,three phase, 50 Hz, indoor type, copper wound, oil cooled, class of insulation A, metallic body duly powder coated designed for input Voltage range 415, +5% and output voltage range 415, +5% and the rate of correction of voltage shall not be less than 6 V/S between phase and neutral, ratio1:1,Vector groop:Dyn 11, Delta, star with first filling of transformer oil of requisite dielectric strength up to level efficiency more than 95%, separate netutral bushing shall be brought for earthing, Potential deference between neutral to earth less than one volt with all standard fittings like digital temperature meter ,adequate number of cooling radiatores, lifting hooksone set, Earthing terminal two nos complete with Over load/short circuit protection .Testing as per BIS 9815 and 2026. Note:- Contractor should arrange factory inspection of Isolation Transformer and precommissioning testing at site. Cost for arrangement of inspection and on site testing are deemed to be included in the quoted rate.
Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size up to 95 sqmm complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size up to 95 sqmm complete all as specified and directed.
Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size up to 95 sqmm complete all as specified and directed.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron earth strip of size 32x6 mm as earthing lead as shown in Electrical Plate No 4 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI med grade water pipe, 50 mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate no-4 of SSR part No1 all as directed.
M & L for earthing complete with copper plate electrode 600x600x3.15 mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less 1.5 mtr deep below normal ground level connected to coopper strip 20x3mm dia by means of brass nut, bolts, check nut , bolt, washer & protection pipe for earth wire from the earthing plate to the DB/main switch/panel,(40mm bore, light grade,) watering pipe from plate to earthing pit (20mm bore, medium grade) funnel wire mesh. The earthing pit made up of PCC 1:3:6 type CI and pit cover made up of 40 mm thik precast RCC 1:2:4 type BI reinforced with 6 mm dia TMT rod and suitable handle of 8 mm dia TMT rod incl necessary earth work as shown in SSR Part-I plate no.5 as specified and directed. Note;- i) The copper strip and protection pipe beyond 7.5 Mtr length shall be measured and paid separately. However earthwork for the same is deemed to be included in this rate . ii) The desired value of earth resistance is less than 5 Ohm on testing after completion if the desired earth rsistance is not obtained the earthing will be redone at no extra cost, otherwise it will not be measued and paid to the contractor . iii) Form work of size .9mx.9mx.6m for pouring charcoal and salt is deemed to be included in this rates . v) During earth work if surface water found at site, the cost for dewatering through pumpset is deemed to be included in this rate.
Supply and fixed of Distribution Transformer step down transformer, outdoor type, plinth mounted HT 11 KV, 3 phase 433 volts, 4 wire, 50 Hz, delta/star connected, vector group DYN -11 double copper wound, ONAN, manual type continuous rating of capacity 160 KVA including bushing on HT end cable box on LT side. The transformer shall be complete with all standard fittings and accessories, gauges, first fill of transformer oil, etc, and conforming to level 2 of IS 1180:2014, BEE certified, duly mounted on 1.2 mtr high plinth and all as specified and as directed. (a) Oil conservator with filling hole, cap and drain plug (b) Silica gel breather with oil seal and first fills of dehydrating agent (c) Adequate Nos of thermometer pockets incl one No for accomodating bulb type thermometer (d) Drain cum bottom filter valve (e) Top filter valve (f) Prisomatic oil level gauge (g) Inspection cover (h) Cover fitting lugs (j) Jacking and fitting lugs (k) Separate neutral bushing brought out for earthing on LV side (l) Earthing terminal (m) Tapping Range & Tapping metod : As per IS 1180-2014, Off load =5.00% to -- 10.00% in vsteps of 2.50% for variationof HV, (n) Temperature Rise in oil -40 deg Centigrade (o) Temperature Rise in Windings -45 deg centigrade Note:- Contractor should arrange factory inspection of Transformer and precommissioning testing at site. Cost for arrangement of inspection in factory and on site testing are deemed to be included in the quoted rate.
Supply, install, testing and commissioning of servo controlled voltage stablizer indoor type (Confirming to BIS:9815:(Second Revision) (reaffirmed 2019) 3- Phase, 50 Hz, Naturally oil cooled, Indoor, Unbalanced Type, Copper wound, Digital Display Type, Relay Smooth and Silent Operation with first filiing Transformer oil (IS335: 1993 reaffirmed 2005) of capacity 200 KVA for unbalanced load with input voltage avriation from 300V-480 V between phase to phase with alarm/protection and by pass facility input voltage & current etc. and comprised of digital multi function meter complete including platform as per manufacturer's norms with the undermentioned features as mentioned below. 1) Input voltage variation from 300V-480 V 2) Output voltage stablized at any designed/desired voltage 415 +- 1% (Adjustable) 3) Rated frequency 50 Hz. 4) No distoration in wave form. 5) Response time not to exceed 10 mille second. 6) Sensitivity (+-) 1%. 7) Rate of correction 8 volts/second for single phase and 20 volt/second for phase to phase. 8) No Load losses less than 0.5%. 9) Fill load losses than 2.5%. 10) Duty cycle - continuous 24 x 7. 11) Efficiency more than 98% 12) Type of load :3 Phase ,unbalanced type. 13) Digital display Voltmeter /Ampmeter.1 14) Capacity :- 200 KVA PROTECTIONS:- 1. Over load/short circuit protections 2. High/Low voltage cut off. 3. By Pass arrangement in case of emergency. 4. Single phase sequence change protection. OPTIONAL PROTECTION:- Ingress Protection (IP) up to IP42//IP 45 a) Physical examination b) Insulation resistance c) High voltage test d) Leakage current test e) Provision for earthing f) Output voltage g) No load current h) Mesurement of no load losses j) Inducted voltage test. Note:- Contractor should arrange factory inspection of Servo Controlled Voltage Stabiliser and precommissioning testing at site. Cost for arrangement of inspection in factory and on site testing are deemed to be included in the quoted rate.
M&L for HT 11 KV, outdoor type gang operated air break switch for horizontal or vertical mounting fix type, Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps complete all as specified and directed.
Supply and fix double compression copper stain less steel gland for fixing armoured cable in panel of size 2 core 6 Sq mm to 35 Sqmm size complete all as specified and directed.
Supply and fix double compression copper stain less steel gland for fixing armoured cable in panel of size 3 core 120 Sq mm to 150 Sqmm size complete all as specified and directed.
M&L for Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-55 (11 Metre long) including painting with two coats of sky blue enamel paint (1.5m from PCC foundation) and aluminium paint (rest of portion) over a coat of red oxide primer complete all as specified and directed.
Supply and fixing of pin type porcelain, vitreous, white, brown or green insulators including galvanized mild steel spindle, two galvanised iron washers and one galvanized iron nuts, 150 mm height 150 mm dia for 11000 volts grade including taking down old unserviceable ones complete all as specified and directed.
M&L for cross arms ,bracing supports, clamps,and backplates fabricated from structural steel sections including nuts ,bolts ,washers ,welding ,bending cold or hot drilling holes for foles for bolts ,in any shape or size as indicated or directed inclusive of one primer coat ,one under coat and one finishing coat of paint.all as specified and directed.
M&L for fixing of triple pole ,mechanically operated ,mounted on nine insulator and steel frame ,with operating mechanissm worked from ground level for current rating 400A ,11000V all as specified and directed.
M&L for fixing of drop out fuse unit assembly complete with MS Base frame & Expulsion fuse ,with operating mechanism worked from ground level,for current rating 400A,11000V complete all as specified and direccted.
M&L for fixing of lightning arrestor expulsion type complete with all fittings ,transmission class, discharge class 65 KA ,11000V including all clamps ,nuts,bolts washer and connecting with existing earth GI Strip of any size Vcomplete all as specified and direccted.
S&F overhead ACSR jumpers weasel type,11KV and transformer leads for connection of GOD at two Pole structure ,length as required at site .incl provision of end lugs, nuts, bolts and washer of suitable size for fixing /conections complete all as specified and direccted.
S&F D.O fuse elements 11KV 10-25 Amps complete all as specified and directed.
S&F Fiber tube with metal fitting on both ends of 11000V grade for drop out fuse assy complete all as specified and direccted.
Material & Labour for PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate for planting cable route indicator /foundation or any other works including necessary formwork (as reqd) complete all as specified and direccted.
Material & Labour for PCC 1:4:8 type D2 using 40mm graded stone aggregate for planting of poles/foundation or any other works including necessary formwork (as reqd) complete all as specified and directed.
Supply and laying in trenches reinforced precast cable cover, class HVP type with peak of size 300x180x40 mm, embosed at "MES HT Cable" for under ground cable protection in trenches with gap between adjacent precast concrete cover not exceeding 10 mm complete all as specified and directed by Engr in Charge.
Supply, erecting, testing and commissioning complete of manufacturer or OEM manufactured, silent type Diesel Engine Driven Generating Set capable of delivering 160 KVA, water cooled, 415 Volts (AC Three phase, 4 Wire system of supply) 50 HZ at power factor 0.8 minimum. The DG Set shall consists of diesel engine coupled to a matching alternator, through flexible coupling and mounted on common base frame and complete with engine control panel and AMF panel , fuel tank with mounting arrangements and exhaust pipe complete and for conditions prevalent at AF Station Borjhar including PCC foundation( of suitable size leaving at least 1.00 M all around for ease of movement and 1.5 M height), anti-vibration pads, including all features to comply with latest CPCB guidelines and Comprising of followings:- (i) ENGINE(Prime Mover): Diesel Engine 1500 RPM , direct injection ,6 cylinders ,four stroke, confirming to ISO3046/BS 5514, water cooled,turbo charged BHP to drive Alternator capable of delivering 160 KVA at outdoor atmospheric conditions at AF station Borjhar asking all derating factor into consideration),12/24 Volt (as per manufacturer's recommendations) electric battery start including Battery as recomended by OEM complete with fly wheel all standard fittings/fixtures as per manufacturer recommendation and including suitable panel with tachometer, lub oil temperature, pressure gauge and frequency meters and also including self starter system, dynamo, fuel electric control panel with electronic governor and Engine protection system shut down, high water temperature, low lub oil, oil pressure, over speed etc) fuel tank and first fill of lub oil and other consumables etc. Engine should conformly latest CPCB norms for ,emmission control ie (i) Nox+HC <04.0 (ii) CO< 3.5 (iii) PM,0.2 (iv) Smoke limit (light absorption co-efficient,m-1<0.7 (ii) Alternator: Brushless AC alternator, 3 Phase, 415 Volt, 4 wire, rated for output of 160 KVA, Minimum power factor 0.8, 1500 RPM, IP 23 Protection class enclosure, insulation Class "H", salient pole, revolving field, single bearing automatic voltage regulator coupled through flexible coupling with and to match the above engine.Applicable standards IS 4722/BS 5000. (iiI) BASE PLATE: Made out of structural steel as per manufacturers recommended design/specifications. (iv) ACOUSTIC ENCLOSURE: Sheet metal fabricated cope type silent enclosure manufactured on CNC machines as per CPCB norms and powder coated after seven tank process, the enclosure shall be designed for reducing the sound level to 75 DB (A) at a distance of 1 M at 75 % load under field condition and ox, 70DB at 3 M from Gen set when DG set is working at full load along with testing conformance, labeling certification etc as laid down in GSR No 371(E) dt 17 May 2002.. (v) Foundation/Plinth/Base: Shall be provided as per manufacturers recommendations, however minimum 1.0 m Space should be available all around the DG Set. (vi) Diesel storage tank of capacity adequate for storage of diesel for 12 hours operation og Gen Set. (vii) MISC: Tool kit, Operation and Maintenance catalogue, spare part list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices. (viii) AMF Panel: Refer Annexure 'A' of BOQ
S & F Modular /combinable Outdoor Floor Mounting polycarbonate insulated panel which should be shock proof ,safe ,IP 54 according to IEC 60 529, weather proof ,rust proof,UV resistant ,halogen free, silica free,,corrosion proof; protection class II totally insulated , having internally embeded gasket , flame retardant , self - extingushing with glow wire test at 960 C according to IEC 60 695-2-11: chemical resistance towards acid , lye , bezene and mineral oil Impact strenth IK 08(5 Joule) in caccordance with DIN EN 50102. The OEM of the Thermoplastic enclosure and the Panel manufacturer should be same and they should confirms the Panel is in accosdance with IEC 61439-1&2 and Routine Test Certificate should be from OEm only and submit according to IEC 61 439-1&2 along with Panel. The OEM of board/Panel SHALL submit a copy of TYPE TEST REPORT(ASTA certification" by CRI) of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following test performed and passed out satisfactrolly:Temperature Ries,Dielectic Properties, Short circuit withstand current - Rated peak & short time withsatnd current and Rated Conditional Short circuit .Current ,Degree of Protection,Clearance & Creepage Distance,Mechanical Operation THe Panel Should have pad lock facility. Panel type -Outdoor Floor Mouning Polycorbonate insulated panel Size-(2150x1585x629)mm Incomer-200A(160A-200A) FP 25KA MCCB-01 No's Digital Ammeter-01 No's Digital Voltmeter -01 No's Digital Frequency Meter-01 No's with R/Y/B indication lamp. Outgoing 32A DP 10 KA MCB -06 No's 80A(63A-80A) FP 25 KA MCB-02 No's 125A FP 15/10KA MCB-02 No's 125A 5Pin IP67 Interlocking Socket with Plug-02 No's Make - Hensel/Spelsbarg/OBO Note-Drawing of Panel should be approved from GE before procurement.
S & F Modular /combinable Outdoor Floor Mounting polycarbonate insulated panel which should be shock proof ,safe ,IP 54 according to IEC 60 529, weather proof ,rust proof,UV resistant ,halogen free, silica free,,corrosion proof; protection class II totally insulated , having internally embeded gasket , flame retardant , self - extingushing with glow wire test at 960 C according to IEC 60 695-2-11: chemical resistance towards acid , lye , bezene and mineral oil Impact strenth IK 08(5 Joule) in caccordance with DIN EN 50102. The OEM of the Thermoplastic enclosure and the Panel manufacturer should be same and they should confirms the Panel is in accosdance with IEC 61439-1&2 and Routine Test Certificate should be from OEm only and submit according to IEC 61 439-1&2 along with Panel. The OEM of board/Panel SHALL submit a copy of TYPE TEST REPORT(ASTA certification" by CRI) of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following test performed and passed out satisfactrolly:Temperature Ries,Dielectic Properties, Short circuit withstand current - Rated peak & short time withsatnd current and Rated Conditional Short circuit .Current ,Degree of Protection,Clearance & Creepage Distance,Mechanical Operation THe Panel Should have pad lock facility. Panel type -Outdoor Floor Mouning Polycorbonate insulated panel Size-(2150x1585x629)mm Incomer- 250A FP 25 KA MCCB -01 No's Digital Ammeter -01 No's, Digital Voltmeter -01 No's, Digital Frequency Meter -01 No'swith R/Y/B indication Lamp. Outgoing 100A FP 25 KA MCCB-04 No;s 32A DP 10 KA MCB-06 No's 63A DP 10 KA MCB -02 No's 63A3 Pin (2P+E IP67 Interlocking Socket with Plug -02 No's 125A 4P 25 KA MCCB-01 No's Make- Hensel/Spelsbarg/OBO Note-Drawing of Panel should be approved from GE before procurement.
Supply ' install ' testing ' commissing LT Cubicle type distribution panel; IP-54 (manfactured from CPRI type tested manfacturere), indoor type made out of 2.00 mm thick CRCA sheet supported on structual frame ' angle or chanel' factory made ' fixed on the ground by galvanised nut & bolts ' PCC works (1:2:4 Type B-1)' The LT cubicle type distribution panel should have enamelled danger notice plate of 1.6 mm thick duly painted with powder coated paint of shade RAL 7032 ( internally & Externally) complete all as specified and directed by Engr-in-charge . The LT distribution panel must have stainless steel hinges , with special type of heavy duty stainless steel front & back door opening , locking arrangements . The Panel should have provision / accommdation of the following electrical items.Make- Legrand/L&T/BHEL or equalent. INDICATING DEVICES (a) High precision energy parameters monitoring meter with rogwski coil for measureing THD ,voltage unbalance ,positive /negative zero sequence component , maximum demand etc.Class-0.5 S Make- Secure(Type -Elite 500)/Schneider /ABB/L&T /Elmeasure=01 No's. (b)LED Type Panel indicator lamp Make-L&T/Schneider /ABB=03 No's BUS BAR (c) Aluminium bus bar 4 strips ( covered with PVC insulated sleeves as per colour code) 600 Amps capacity, including connection etc complete-01 set. INCOMING (d) Moulded case circuit breaker 250-320 Amps 415 Volts ( Vertically Palced), 4 Pole 36 KA breaking capacity .Ics =100% Icu , adjustable overhead settings 0.8-1.0 x in , adjustable short circuit settings 6-10 x in Make- Siemens /ABB/=02 No's OUTGOING (e) On- Load Manual change over Switch ( Open Execution type) 250 Amps 425 Volts, 4 poles Make-L&T/ Siemens/ABB=01 No's (f) Moulded case circuit breaker 160-200 Amps 415 Volts ( Vertically Placed) 4 Pole 25 KA breaking capacity , Ics=100% Icu, adjastable overload settings 0.8-1.0x in , adjustable short circuit settings 6-10 x In make- Siemens/ABB/Legrand =02 No's (g) Moulded case circuit breaker 125-160 Amps 415 Volts ( Vertically Placed) 4 Pole 25 KA breaking capacity , Ics=100% Icu, adjastable overload settings 0.8-1.0x in , adjustable short circuit settings 6-10 x In make- Siemens/ABB/Legrand =02 No's (h) Moulded case circuit breaker 100 Amps 415 Volts ( Vertically Placed) 4 Pole 25 KA breaking capacity , Ics=100% Icu, adjastable overload settings 0.8-1.0x in , adjustable short circuit settings 6-10 x In make- Siemens/ABB/Legrand =01 No's (j)Moulded case circuit breaker 40-50 Amps 415 Volts ( Vertically Placed) 4 Pole 25 KA breaking capacity , Ics=100% Icu, adjastable overload settings 0.8-1.0x in , adjustable short circuit settings 6-10 x In make- Siemens/ABB/Legrand =02 No's Note- The connection between the MCCB and bus bar should be done by aluminium bar of suitable rating all as specified and directed
PURBANCHAL BUILDERS
M/s Nice Traders
M/s Dhani Enterprise
M/s PRABIR ENTERPRISE
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .