Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹35.3 L+₹2.0 L (6.06%)Rejected-Finance | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹38.1 L+₹4.8 L (14.4%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹39.1 L+₹5.8 L (17.3%)Rejected-Finance | L4 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | RAHUL ENTERPRISES L1 | devan enterprises L3 | B5BUILDING SOLUTIONS L4 | SRINIDHI DIESELS & ELECTRICALS L2 |
|---|---|---|---|---|---|---|---|
| 1.00A CHECK : Material and labour for monthly Inspection, maintenance and servicing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintenance complete all as specified and as directed. | |||||||
| 1.01MONTHLY SERVICE : (a) Checking engine oil level and topping up as and when required . Note : Oil shall be measured and paid separately (b) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid separately (c) Checking of oil bath air cleaner level (d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank (f) Cleaning of air cleaner element (g) Checking engine alternator coupling, mounting bolts and alignment (h) Tighting all nuts, bolts, in alternator terminal block | |||||||
| 1.02(j) Checking of alternator carbon brush and connections in alternator (k) Checking and tighting of all connection in DC control wiring. (l) Checking of all radiator rubber hose and replacement if required. Note : Hose pipe shall be measured and paid separately (m) Checking and recording oil pressure, water and oil temperature (n) Checking anti vibration mounting and replacement if required. Note : Anti vibration pad shall be measured and paid separately (o) Checking throttle linkage (p) Checking battery for cell test, electrolyte level, gravity and topping up to required level (q) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. (r) Checking of AMF panel, all electrical connections etc. (s) Checking of earthing resistance (t) Cleaning of vegetation around the DG set up to 1.5 mtr area. | |||||||
| 1.03 | 500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : CASDIC-03 Nos, GTRE 7A bldg, GTRE ICE lab, CABS near AEW&C bldg, STIR-02 Nos (Total 08 Nos) | 56 | PER MONTH | 900 ₹50,400 Lowest | 3,000 ₹1,68,000 | 3,500 ₹1,96,000 | 2,414 ₹1,35,184 |
| 1.04 | 500 KVA Capacity, Make : Greaves, Model I2VI4TAG23, Location : GTRE GTX-2 & P-147 (02 Nos) | 14 | PER MONTH | 900 ₹12,600 Lowest | 3,000 ₹42,000 | 3,500 ₹49,000 | 2,414 ₹33,796 |
| 1.05 | 500 KVA Capacity, Make : Kirloskar, Model DV10TAG-1, Location : CEMILAC | 7 | PER MONTH | 900 ₹6,300 Lowest | 3,000 ₹21,000 | 3,500 ₹24,500 | 2,414 ₹16,898 |
| 1.06 | 320 KVA Capacity, Make : Cummins, Model KT-1150-G TA, Location : C type Sub stn | 7 | PER MONTH | 900 ₹6,300 Lowest | 3,000 ₹21,000 | 3,000 ₹21,000 | 2,200 ₹15,400 |
| 1.07 | 320 KVA Capacity, Make :Greaves Model TBD2V12MKII, Location : GTRE New Assembly Hanger | 7 | PER MONTH | 900 ₹6,300 Lowest | 3,000 ₹21,000 | 3,000 ₹21,000 | 2,200 ₹15,400 |
| 1.08 | 250 KVA Capacity, Make : Kirloskar, Model 6SL8800TA, Location : Pump House 'E' type | 7 | PER MONTH | 750 ₹5,250 Lowest | 2,800 ₹19,600 | 2,900 ₹20,300 | 1,921 ₹13,447 |
| 1.09 | 250 KVA Capacity, Make : Greaves, Model D3V6TAG21 , Location : GTRE Testing cell & GTRE (Project Bldg) - (02 Nos) | 14 | PER MONTH | 750 ₹10,500 Lowest | 1,550 ₹21,700 | 2,850 ₹39,900 | 1,921 ₹26,894 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
7 Jul 2025, 6:00 pmClosed
GE I RnD East Bangalore
DRDO Complex, CV Raman Nagar PO, Bangalore 560 093
REPAIR MAINTENANCE OF DG SETS AMF PANELS CONTROL PANELS AND CONNECTED ALLIED WORKS AT GTRE AND CERTAIN LABS UNDER GE I RnD EAST BANGALORE
2025_MES_708652_1
8608/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
BANGALORE
Class D Category b(i)
8 documents required · 8 mandatory
₹500
Yes
GE I RnD East Bangalore
₹96,000
Yes
13 Aug 2025
10 Jun 2025
12 Jul 2025
10 Jun 2025
7 Jul 2025
24 Jun 2025
11 Jun 2025 - 23 Jun 2025
Amount
A CHECK : Material and labour for monthly Inspection, maintenance and servicing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintenance complete all as specified and as directed.
MONTHLY SERVICE : (a) Checking engine oil level and topping up as and when required . Note : Oil shall be measured and paid separately (b) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid separately (c) Checking of oil bath air cleaner level (d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank (f) Cleaning of air cleaner element (g) Checking engine alternator coupling, mounting bolts and alignment (h) Tighting all nuts, bolts, in alternator terminal block
(j) Checking of alternator carbon brush and connections in alternator (k) Checking and tighting of all connection in DC control wiring. (l) Checking of all radiator rubber hose and replacement if required. Note : Hose pipe shall be measured and paid separately (m) Checking and recording oil pressure, water and oil temperature (n) Checking anti vibration mounting and replacement if required. Note : Anti vibration pad shall be measured and paid separately (o) Checking throttle linkage (p) Checking battery for cell test, electrolyte level, gravity and topping up to required level (q) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. (r) Checking of AMF panel, all electrical connections etc. (s) Checking of earthing resistance (t) Cleaning of vegetation around the DG set up to 1.5 mtr area.
500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : CASDIC-03 Nos, GTRE 7A bldg, GTRE ICE lab, CABS near AEW&C bldg, STIR-02 Nos (Total 08 Nos)
500 KVA Capacity, Make : Greaves, Model I2VI4TAG23, Location : GTRE GTX-2 & P-147 (02 Nos)
500 KVA Capacity, Make : Kirloskar, Model DV10TAG-1, Location : CEMILAC
320 KVA Capacity, Make : Cummins, Model KT-1150-G TA, Location : C type Sub stn
320 KVA Capacity, Make :Greaves Model TBD2V12MKII, Location : GTRE New Assembly Hanger
250 KVA Capacity, Make : Kirloskar, Model 6SL8800TA, Location : Pump House 'E' type
250 KVA Capacity, Make : Greaves, Model D3V6TAG21 , Location : GTRE Testing cell & GTRE (Project Bldg) - (02 Nos)
200 KVA Capacity, Make : Cummins, Model NTA-743-G, Location : MES Sub Stn 'E' type (02 Nos) & RTC (Total 03 Nos)
180 KVA capacity, Make : Kirloskar, Model AT00036074 , Location : CEMILAC
125 KVA Capacity, Make : Kirloskar, Model 6R 1080 TA, Location : Pump House 'E' type & CDA bldg (02 Nos)
100 KVA Capacity, Make : Kirloskar, Model 6R1080 T, Location : GTRE PMO bldg & STIR bldg (02 Nos)
75 KVA Capacity, Make : Ashok Layland Model AL4CTIDG3, Location : GTRE MLCP bldg
62.5 KVA Capacity, Make : Kirloskar, Model 4AB225S1, Location : GTRE Wet Canteen, MRS III, CABS near security bldg (03 Nos)
50 KVA Capacity, Make : Cummins, Model- 4BTAA303-G11, Location : CABS near security bldg
50 KVA Capacity, Make : Kirloskar, Model 94AH 162480, Location : GE Office
40 KVA Capacity, Make : Greaves, Model 3G11TAG25, Location : GTRE GTX-9
30 KVA Capacity, Make : Greaves, Model 4PWII-PII-30X, Location : CABS Pump house
B' Check once in Six month OR 250 Hrs running of DG set whichever is Earlier
Material and labour for required for inspection, maintenance, servicing of DG sets of following capacities, including items covered in B check of DG set for smooth functioning and carrying out maintenance complete as per OEM instruction and as directed :- (a) Repeat the activities of 'A' Check (b) Replacement of lubricant oil. (Note:- Lub Oil are Paid separately.) (c) Replacing lubricant oil filter element with 'O' ring (d) Replacing fuel filter element (e) Replacing coolant. (f) Replacing Governor oil
NOTE : B Check kit, coolant and Lubricant oil shall be measured and paid separately under relevant items of Sch 'A'
500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : CASDIC-03 Nos, GTRE 7A bldg, GTRE ICE lab, CABS near AEW&C bldg, STIR-02 Nos (Total 08 Nos)
500 KVA Capacity, Make : Greaves, Model I2VI4TAG23, Location : GTRE GTX-2 & P-147 (02 Nos)
500 KVA Capacity, Make : Kirloskar, Model DV10TAG-1, Location : CEMILAC
320 KVA Capacity, Make : Cummins, Model KT-1150-G TA, Location : C type Sub stn
320 KVA Capacity, Make :Greaves Model TBD2V12MKII, Location : GTRE New Assembly Hanger
250 KVA Capacity, Make : Kirloskar, Model 6SL8800TA, Location : Pump House 'E' type
250 KVA Capacity, Make : Greaves, Model D3V6TAG21 , Location : GTRE Testing cell & GTRE (Project Bldg) - (02 Nos)
200 KVA Capacity, Make : Cummins, Model NTA-743-G, Location : MES Sub Stn 'E' type (02 Nos) & RTC (Total 03 Nos)
180 KVA capacity, Make : Kirloskar, Model AT00036074 , Location : CEMILAC
125 KVA Capacity, Make : Kirloskar, Model 6R 1080 TA, Location : Pump House 'E' type & CDA bldg (02 Nos)
100 KVA Capacity, Make : Kirloskar, Model 6R1080 T, Location : GTRE PMO bldg & STIR bldg (02 Nos)
75 KVA Capacity, Make : Ashok Layland Model AL4CTIDG3, Location : GTRE MLCP bldg
62.5 KVA Capacity, Make : Kirloskar, Model 4AB225S1, Location : GTRE Wet Canteen, MRS III, CABS near security bldg (03 Nos)
50 KVA Capacity, Make : Cummins, Model- 4BTAA303-G11, Location : CABS near security bldg
50 KVA Capacity, Make : Kirloskar, Model 94AH 162480, Location : GE Office
40 KVA Capacity, Make : Greaves, Model 3G11TAG25, Location : GTRE GTX-9
30 KVA Capacity, Make : Greaves, Model 4PWII-PII-30X, Location : CABS Pump house
Supply only B check kit for DG set of following capacities :- NOTE : It Includes to Oil filter (1.00 Ltr/0.5 ltr), Diesel filter , by pass element.
500 KVA Capacity, Make : Cummins, Model KTA-19-G9, Location : CASDIC-03 Nos, GTRE 7A bldg, GTRE ICE lab, CABS near AEW&C bldg, STIR-02 Nos (Total 08 Nos)
500 KVA Capacity, Make : Greaves, Model I2VI4TAG23, Location : GTRE GTX-2 & P-147 (02 Nos)
500 KVA Capacity, Make : Kirloskar, Model DV10TAG-1, Location : CEMILAC
320 KVA Capacity, Make : Cummins, Model KT-1150-G TA, Location : C type Sub stn
320 KVA Capacity, Make :Greaves Model TBD2V12MKII, Location : GTRE New Assembly Hanger
250 KVA Capacity, Make : Kirloskar, Model 6SL8800TA, Location : Pump House 'E' type
250 KVA Capacity, Make : Greaves, Model D3V6TAG21 , Location : GTRE Testing cell & GTRE (Project Bldg) - (02 Nos)
200 KVA Capacity, Make : Cummins, Model NTA-743-G, Location : MES Sub Stn 'E' type (02 Nos) & RTC (Total 03 Nos)
180 KVA capacity, Make : Kirloskar, Model AT00036074 , Location : CEMILAC
125 KVA Capacity, Make : Kirloskar, Model 6R 1080 TA, Location : Pump House 'E' type & CDA bldg (02 Nos)
100 KVA Capacity, Make : Kirloskar, Model 6R1080 T, Location : GTRE PMO bldg & STIR bldg (02 Nos)
75 KVA Capacity, Make : Ashok Layland Model AL4CTIDG3, Location : GTRE MLCP bldg
62.5 KVA Capacity, Make : Kirloskar, Model 4AB225S1, Location : GTRE Wet Canteen, MRS III, CABS near security bldg (03 Nos)
50 KVA Capacity, Make : Cummins, Model- 4BTAA303-G11, Location : CABS near security bldg
50 KVA Capacity, Make : Kirloskar, Model 94AH 162480, Location : GE Office
40 KVA Capacity, Make : Greaves, Model 3G11TAG25, Location : GTRE GTX-9
30 KVA Capacity, Make : Greaves, Model 4PWII-PII-30X, Location : CABS Pump house
Supply only coolant, K cool super plus 50-50 Premix
Supply only Battery water with electrolyte mix
Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil
Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged complete all as specified and as directed. MAKE : EXIDE / AMARON
Material and labour for replacement of unserviceable battery 12 V, 150 AH with maintenance free battery 12 Volt initially charged complete all as specified and as directed. MAKE : EXIDE / AMARON
Material and labour for replacement of unserviceable battery 12 V, 90 AH with maintenance free battery 12 Volt initially charged complete all as specified and as directed. MAKE : EXIDE / AMARON
Supply and fix single phase preventer SPPR type SDz5, SPPR + Timer, 415 volts, 50 Hz, suitable for 3 phase DG Panel complete all as specified and as directed. MAKE : L&T Cat No XM81809OOOO or SEIMENS / BCH
Supply and fix Electronic timers type ST100 , 415 volts, 50 Hz, suitable for 3 phase DG Panel complete all as specified and as directed. MAKE : L&T Cat No ST80328OOOO
Supply and fix DG Set 320/365/500 KVA Controller Dia, AVR, Start Stop Relay, wiring & Modification complete testing complete all as specified and as directed.
Material and labour for repair/replacement of rusted, damaged sound proof canopy for DG set 200 KVA capacity duly fabricated out of 1.6mm thick CRC sheet. The canopy meets noise 70 to 75 DB one meter distances as per norms sound proofing of the enclosure is dun with sound proof accousting rock wool 96/m3 density and thckness 100mm complete all as specified and as directed.
Dismantling, radiator assembly from the engine of following capacity of DG Set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing, removing blockages arresting leakages, assembling back incl necessary welding brazing as required , refixing , reconnecting and testing for proper functioning complete all as specified and as directed.:
(a) 30 / 40 /50 KVA Capacity
(b) 62.5/75 KVA Capacity
(c) 100 /125 KVA Capacity
(d) 180/200/250 KVA Capacity
(e) 320 KVA Capacity
(f) 500 KVA Capacity
Dismantling, removing the alternator /dynamo of from the engine of following capacity of DG Sets , opening up over hauling servicing, replacement of carbon brushes with holders, assembling back , refixing and testing for proper function complete all as specified and as directed.
(a) 30 / 40 /50 KVA Capacity
(b) 62.5/75 KVA Capacity
(c) 100 /125 KVA Capacity
(d) 180/200/250 KVA Capacity
(e) 320 KVA Capacity
(f) 500 KVA Capacity
Dismantling , removing the self startor from the engine of following capacity DG Sets , opening up , over hauling/ servicing, replacement of carbon brushes with holders assembling back, refixing and testing for proper function complete all as specified and as directed.
(a) 30 / 40 KVA Capacity
(b) 50/ 62.5 KVA Capacity
(c) 75/100 /125 KVA Capacity
(d) 180/200/250 KVA Capacity
(e) 320 KVA Capacity
(f) 500 KVA Capacity
Dismantling of fuel injector assembly complete from the engine of following capacity of DG Sets, reconditioning/ serving, replacement of pim spiral, washers, Cup injector,retainer, Cup screw etc assembling calibration, setting for proper function refixing and testing for complete all as specified and as directed.:
(a) 30 / 40 KVA Capacity
(b) 50/ 62.5 KVA Capacity
(c) 75/100 /125 KVA Capacity
(d) 180/200/250 KVA Capacity
(e) 320 KVA Capacity
(f) 500 KVA Capacity
Disconnecting all the connections from alternator of DG Set of following Capacity removing the alternator from foundations , transporting to workshop, dismantling completely including starter, roter, removing rotor and bearing clening all the parts with thinner and varnishing completely with F class varnishing, applying epoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and realignment within tolerance limit , connecting the alternator with all connections and testing on load completely complete all as specified and as directed.
(a) 30 / 40 KVA Capacity
(b) 50/ 62.5 KVA Capacity
(c) 75/100 /125 KVA Capacity
(d) 180/200/250 KVA Capacity
(e) 320 KVA Capacity
(f) 500 KVA Capacity
Material and labour for replacement of defective spare parts of DG Sets of capacity 500 KVA, MAKE : CUMMINS, Model KTA-19-G9 / MAKE : GREAVES, Model I2VI4TAG23 / MAKE : KIRLOSKAR, Model DV 10TAG-1 including connecting and testing complete all as specified and as directed.
(a) Radiator Hose Pipe Set
(b) Air filter (inner & Outer)
(c) Water Pump assembly
(d) Turbocharger repair Kit
Material and labour for replacement of defective spare parts of DG Sets of capacity 320KVA, MAKE : CUMMINS, Model KT-1150-G TA including connecting and testing complete all as specified and as directed.
(a) Fuel Pipe
(b) Air filter (inner & Outer)
(c) V Belt
(d) Water Pump Kit
Material and labour for replacement of defective spare parts of DG Sets of capacity 320 KVA, MAKE : GREAVES Model TBD2V12MKII including connecting and testing complete all as specified and as directed.
(a) Air filter
(b) V belt
(c) Fuel Pipe
(d) Battery terminals
Material and labour for replacement of defective spare parts of DG Sets of capacity 250KVA, MAKE : KIRLOSKAR, Model 6SL8800TA and MAKE : GREAVES, Model D3V6TAG21 including connecting and testing complete all as specified and as directed.
(a) Air filter inner
(b) Air filter assembly
(c) V Belt
(d) Oil Seal
Material and labour for replacement of defective spare parts of DG Sets of capacity 200 KVA / 180 KVA including connecting and testing complete all as specified and as directed.
(a) Air filter Inner
(b) Turbo charger repair Kit
(c )Water Pump Assembly
Material and labour for replacement of defective spare parts of DG Sets of capacity 100/125 KVA, including connecting and testing complete all as specified and as directed.
(a) Air Filter
(b) V Belt
(c) Hose Pipe Set
Material and labour for replacement of defective spare parts of DG Sets of capacity 75 KVA / 62.5 KVA including connecting and testing complete all as specified and as directed.
(a) Air filter
(b) V Belt
(c) Hose Pipe Set
Material and labour for replacement of defective spare parts of DG Sets of capacity 50 KVA /40 KVA including connecting and testing complete all as specified and as directed.
(a) Air filter
(b) V Belt
Material and labour for replacement of defective spare parts of DG Sets of capacity 30 KVA including connecting and testing complete all as specified and as directed.
(a) Air filter
(b) V Belt
(c) Hose Pipe Set
Material and labour for replacement of Door Hinges of various capacity of DG Set
Supply and fixing battery lead with negative & Positive brass terminals of suitable size with 3 m length of each lead complete all as specified and as directed.
Material and labour for complete checking of AMF panel,finding the fault, servicing complete including replacement of unserviceable spares and testing complete for manual & Auto operations complete all as specified and as directed. NOTE : Supply only of new items required for replacement will be measured and paid separately under respective item of schedule.
Repair to AMF Panels any capacity of DG set dismantling/taking down of all electrical connection from unserviceable AMF panel to carry out following repairs :- (a) Replacement of unserviceable microprocessor auto main failure relay 400 volt AC 3 phase 4 wire system having following parameter :- (i) Display of RYB phase voltage. (ii) Display of generating voltage. (iii) Display of generator frequency. (iv) Display of main frequency. (v) Display of battery voltage. (vi) Display of single phase current. (vii) Display of generator run hours Make:- C&S/Hitech or equivalent. (b) Replacement of digital multifunctional meter of size 96x96mm having following parameter: (i) Voltage, ampere and frequency (c) Replacement of digital energy meter 3 phase of size 96X96mm. (d) Replacement of safety control relay for cranking-01 Nos. (e) Replacement of burnt out control wiring for panel with suitable size of lugs. (f ) Replacement of auto/manual switch
Material and labour for replacement of unserviceable contactor AC operated 4 pole 415 volts suitable for the following capacity of DG set complete all as specified and as directed.
(a) DG set 320 KVA
(b) DG set 250 KVA
(c) DG set 200 KVA
(d) DG set 160 KVA
(e) DG set 100 KVA
(f) DG set 75 KVA
(g) DG set 50/40 KVA
Material and labour for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 320 KVA /250 KVA/ 200 KVA complete all as specified and as directed.
Material and labour for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 100 /125 KVA complete all as specified and as directed.
Supply and fix in replacement of window glass of canopy of capacity 500 KVA/320KVA complete all as specified and as directed.
Supply and fix in replacement of window glass of canopy of capacity 250KVA/200KVA complete all as specified and as directed.
Taking out old unserviceable battery charger from the following DG sets replacement with the following battery charger of suitable capacity and checking the terminals including petroleum jelly and spray cleaning for the following capacities of DG sets complete all as specified and as directed.
(a) Battery charger 24 volts 20 Amps capacity panel mounted suitable for 500 KVA DG set complete all as specified and as directed.
(b) Battery charger 24 volts 10 Amps capacity panel mounted suitable for 200/250/320 KVA DG set complete all as specified and as directed.
(c) Battery charger 12 volts 20 Amps capacity panel mounted suitable for 100/125 KVA DG set complete all as specified and as directed.
(d) Battery charger 12 volts 10 Amps capacity panel mounted suitable for 30/40/50/62.5 KVA DG set complete all as specified and as directed.
SRINIDHI DIESELS & ELECTRICALS (BID ID -3348101)
devan enterprises (BID ID -3341690)
B5BUILDING SOLUTIONS (BID ID -3346950)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .