Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 CrAccepted-AOC HOUSE NO 3000 SECTOR 15 HOUSING BOARD COLONY SONIPAT 131001 | SONIPAT | SONIPAT | HARYANA | 131001 | ₹5.9 Cr | L1 | Accepted-AOC Awarded |
| 2 | L2₹6.0 Cr+₹11.3 L (1.92%)Rejected-AOC | ₹6.0 Cr+₹11.3 L (1.92%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹6.1 Cr+₹19.7 L (3.34%)Rejected-AOC H NO 1100 SECTOR 3 124001 | ROHTAK | HARYANA | 124001 | ₹6.1 Cr+₹19.7 L (3.34%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹6.5 Cr+₹64.8 L (11.0%)Rejected-AOC | ₹6.5 Cr+₹64.8 L (11.0%) | L4 | Rejected-AOC Rejected |
Tender Value
₹6.5 Cr
EMD Value
₹13.0 L
Closing Date
16 Jun 2023, 4:00 pmClosed
Tarun Garg
EE PHE Division No. 2 Rohtak
Const. of Raw Water Pumping Station, Repair of Existing Structures, Laying of Distribution pipe line, Prov. FHTC, Proop. structures at 1st water works Const. 2 Nos. Filter beds, Streng. of 1 existing SandS Tank and Prop. structures at 2nd WW Const
2023_HRY_286936_1
2023CAFA630E 455C 498A 9C4C 36341FDEB683577PUH
Open Tender
Civil Works
Works
365 days
KHARKARA BHIKLAN
2 documents required · 2 mandatory
₹20,000
Yes
₹13.0 L
Yes
21 Sept 2023
1 Jun 2023
16 Jun 2023
1 Jun 2023
16 Jun 2023
1 Jun 2023
Amount
`Copper conductor: Supply, erection, testing and commissioning of IS marked 3 core copper wire with accessories like thimble lugs etc for motors in trenches or underground in PVC and flexible pipes as per entire satisfaction of Engineer-in-charge complete in all respect. ` 25mm2 3core
`Copper conductor: Supply, erection, testing and commissioning of IS marked 3 core copper wire with accessories like thimble lugs etc for motors in trenches or underground in PVC and flexible pipes as per entire satisfaction of Engineer-in-charge complete in all respect. ` 35mm2 3core
H.T. Meter: Supply and erection of HT metering panle including suitable size 11 KV HT XLPE alluminium armored cable network from G.O. Switch to H.T. Metering equipment and from H.T. Metering to Transformer Main to L.T. Panel earthling, safety equipment, fenced enclosure for transformer, and any other contingent thereto complete in all respect as per approved make and directions of Engineer-in charge and getting it passed from Chief Electrical Officer.
WTP: Design, construction, testing and commissioning of 0.50 MLD capacity Water treatment plant including inlet channel, Alum dozing, Flash mixing, Clarifloculator, filter box, over head Reservoir for back wash, waste water tank, all civil work, pumping machineries and electric cabling, control panels, suitable size entire piping network DI pipe from raw water pump to inlet box of WTP, WTP to CWT and CWT to C/W Suction Well including DI specials, suitable size Sluice valves, Hodies, manhole covers, air scour equipment, chemical house including chlorination equipment and arrangement of flow measurement and sand bed complete in all respects as per NIT (Sluice valves of make IVC/VAG) . 0.50 MLD Capacity
Supply, erection, testing and commissioning of Horizontal centrifugal split casing raw water pumping set having head as per the indicated requirement of discharge in LPM and power capacity in BHP complete in all respect. Make KSB , CRI, Kirlosker, Crompton , Greeve, Lubi) 500 LPM Head 15 mtr. 5 BHP ISI Make
Supply, erection , testing and commissioning of Horizontal centrifugal split casing raw water pumping set complete in all respect. 4400 LPM 30 Mtr head 50 BHP
PANEL BOARD FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) 4400 LPM 30 M Head
PANEL BOARD FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) 500 LPM 15 M
10 HP PANEL BOARD FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCAsheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. ofapproved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) 950 LPM 25 M Head
PANEL BOARD FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) 1200 LPM 40 M Head
25 HP PANEL BOARD FOR MOTORS: Supply, erection, testing and commissioning of wall mounted electrical LT Panel board, fabricated from 16 SWG CRCA sheet duly stouten with suitable angle iron frame work and completely powder coated of suitable size deep having following items for Main switch suitable ampere 1 No. (LandT Siemens, ABB) b) CT 100/3 = 1 Nos. (AE/ KAPPA/ LandT) c) Digital Multi function meter = 1 No. d) SPP = 1 No. of approved make e) Motor starter, star delta 1 No (LandT Siemens, ABB) f) VSS 1 No. and ASS 1 Nos. of approved make. g) Capacitor KVAR as per site requirement = 1 No. h) Indicating Lamp = One Set i) Change over switch of suitable Amp = 1 No. (Each) 1500 LPM 40 M Head
(ii) Operation and Maintenance during 1st year after defect liability period.
(iii) Operation and Maintenance during 2nd year.
(iv) Operation and Maintenance during 3rd year.
(v) Operation and Maintenance during 4th year.
(vi) Operation and Maintenance during 5th year.
Operation and Maintenance for complete scope of work mentioned in the DNIT including existing Boosting Station (Disinfection material supplied by PHED) as per schedule-IV for a period of 5 year after 12 month during defect liability period and 03 Months trial run will be charged to the A/Mtc. estimate complete in all respect as per approved NIT 1 Operation and Maintenance during defect liability period (Operation only) after 3 month trial run.
Bidder Name
Amount
Kulbir Singh Contractor(GSTN-06ATZPS6352H1ZW)
RAVI PARKASH CONTRACTOR(GSTN-06AJMPP2964K1ZN)
Jaiveer Singh Contractor(GSTN-06ATQPS8420H1Z8)
VINAY KUMAR CONTRACTOR(GSTN-NA)
Jaiveer Singh Contractor
Kulbir Singh Contractor
RAVI PARKASH CONTRACTOR
Kulbir Singh Contractor
RAVI PARKASH CONTRACTOR
VINAY KUMAR CONTRACTOR
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .