Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹3.1 LAccepted-AOC | 1 | Accepted-AOC Lowest awarded | |
| 2 | 2₹1.4 L+₹7,976.80 (1.74%)Accepted-AOC | 2 | Accepted-AOC L2 awarded | |
| 3 | 3₹5.7 L+₹1.1 L (25.1%)Rejected-Finance 106A S B KAMAL AND SONS ACHARYA PRAFULLA CHANDRA ROAD SUKIYA STREET KOLKATA WEST BENGAL 700009 | KOLKATA | WEST BENGAL | 700009 | 3 | Rejected-Finance Not Agree L1 Rate |
Tender Value
₹5.8 L
EMD Value
₹11,576
Closing Date
19 Apr 2025, 3:00 pmClosed
Executive Engineer(E), ED KGP
OFFICE OF THE EXECUTIVE ENGINEER (E),BSNL ELECTRICAL DIVISION, KHARAGPUR,OLD DTO Building., Bogda, Kharagpur-721301
SITC of 1.5TR Inverter type split AC units, repairing of existing split AC units and DG sets at various sites for readiness of infra for Amended Bharat Net Project in Kharagpur BA, SH Repairing of 1.5 TR Air Conditioners at District MEDINIPUR EA
2025_BSNL_232351_1
02/ BSNL/ED-KGP/2025-26
Open Tender
Electrical Works
Item Rate
60 days
West and East Medinipur, Jhargram District
Eligibility Criteria as per NIT
2 documents required · 2 mandatory
₹590
Yes
Account Officer Cash,Office of the GMT Kharagpur
₹11,576
Yes
24 May 2025
12 Apr 2025
22 Apr 2025
12 Apr 2025
19 Apr 2025
12 Apr 2025
12 Apr 2025 - 19 Apr 2025
Replacement and fixing of following spares parts / accessories for 1.5 TR Split AC i/c connections, testing, dismantling the damaged ones, etc. complete as required: -
Running Capacitor.
Motor Capacitor.
Starting Relay.
Starting Capacitor.
Indoor Unit Motor (New).
Outdoor Unit Motor (New).
Outdoor Unit Fan Blade.
Indoor Unit Fan Blade.
Replacement of faulty /defective 1.5 TR capacity compressor with new Sealed compressor i/c dismantling of faulty compressor, cutting refrigerant piping, brazing & making necessary addition/alteration i/c proper mounting on base plate, connection of suction and discharge lines, Leak test , supplying & charging required qty. refrigerant gas i/c testing commissioning etc as reqd.(M/s Emerson/Tecumseh/SS make) (Note - The firm shall submit test certificate or documentary proof towards purchase of New compressor.) The defective compressor shall be the property of agency & firm should consider suitable price rebate for the same while quoting. The material under replacement shall be similar to existing defective material or as per product directory)
25 A DP MCB with S. S enclosure.
Capillary Tube.
Strainer.
Carrying out Wet Servicing of 1.5TR / 2TR Window / Split AC unit i/c removing, cleaning all components and filters, de-dusting by high pressure air blower, washing condenser and evaporator Coil with high pressure wate jet by arrange canopy for indoor unit i/c chemical cleaning, refixing, tightening electrical connections, minor repairs, if required, testing of AC unit, recording all parameters in service report etc as reqd.
For Split A.C (1.5 TR)
Topping up of refrigerent (R-22) in existing SAC unit by charging manifold, leak testing by soap solution, pressure testing, etc. complete as required.
For Split A.C (1.5 TR)
Supplying and charging of refrigerant (R-22) in the existing SAC unit by charging manifold, leak testing , self vaccuming, pressure testing, etc. complete as required.
For Split A.C (1.5 TR)
Supplying and charging of refrigerant (R-410 A) in the existing SAC unit by charging manifold, leak testing , self vaccuming, pressure testing, etc. complete as required.
For Split A.C (1.5 TR)
Rewinding of cooling unit fan motor of 1.5 TR SAC Indoor unit after dismantling from existing position, rewinding by super enamelled copper wire, heat varnishing, fixing in original position after rewinding, testing, commisioning, etc. complete as required.
Rewinding of condenser unit fan motor of 1.5 TR SAC Outdoor unit after dismantling from existing position, rewinding by super enamelled copper wire, heat varnishing, fixing in original position after rewinding, testing, commisioning, etc. complete as required.
Repairing of control Card of inverter type SAC unit i/c replacement of faulty spare parts and fitting, fixing, connecting, testing, checking etc. as reqd.
ELECTRO CARE (BID ID -842686)
S B KAMAL AND SONS (BID ID -841796)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .