16 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Note: In case, date of tender inviting is on or after date of statutory deadline for audit of balance sheet of previous FY (i.e. 30th Sept or as further extended for this FY), audited balance sheet of 4th previous year shall not be considered unless concerned CA certifies that balance sheet is not audited yet as on date of invitation of this tender.
The contractor should have valid Electrical Contractor License issued by Govt. and submit along with tender document. If valid Electrical Contractor License is not submitted along with tender document, then offer will be summarily rejected.
16 conditions · 3 needing a document upload
The tenderer shall submit all relevant documents as detailed in para 14 & 18.10 of Tender Form (Second Sheet) of Part I of GCC work-2022.
The tenderer shall submit copy regarding status of firm i.e. sole proprietorship, partnership, Company, Society/Trust etc. and also submit a power of attorney and other relevant documents as detailed in Para no. 15 of Tender Form (Second Sheet) of Part- I of attached GCC-2022.
The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. Following documents shall be submitted by the tenderer:
a) Sole Proprietorship Firm: (i) All documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(b) HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF. (ii) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC- 2022.
(c) Partnership Firm: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract. (iv) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(e) Company registered under Companies Act 2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(f) LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm / LLP or JV in which they were / are partners / members. Concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract. (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
(g) Registered Society & Registered Trust: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society (v) All other documents in terms of Para 10 of the Tender Form (Second Sheet) of GCC-2022.
The tenderer whether sole proprietor / a company or a partnership firm / joint venture (JV) / registered society / registered trust / HUF / LLP etc if they want to act through agent or individual partner(s), should submit along with the tender, a copy of power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, specifically authorizing him / them to sign the tender, submit the tender and further to deal with the Tender / Contract up to the stage of signing the agreement except in case where such specific person is authorized for above purposes through a provision made in the partnership deed / Memorandum of Understanding / Article of Association / Board resolution, failing which tender shall be summarily rejected. A separate power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he / they be partner(s) of the firm or any other person, shall be submitted after award of work, specifically authorizing him/them to deal with all other contractual activities subsequent to signing of agreement, if required. Note: A Power of Attorney executed and issued overseas, the document will also have to be legalized by the Indian Embassy and notarized in the jurisdiction where the Power of Attorney is being issued. However, the Power of Attorney provided by Bidders from countries that have signed the Hague Legislation Convention 1961 are not required to be legalized by the Indian Embassy if it carries a conforming Apostille certificate.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should quote only the above/below percentage on estimated value, in the space provided at web portal for the purpose & nowhere else. Financial & Technical conditions quoted at any place other than prescribed space shall not be entertained while evaluating the offer.
Tenderer are required to go through the documents attached along with the tender and submit their bids accordingly.
Electrical work in c/w Development of infrastructure/maintenance facilities for trains at Suratgarh Station, Work for shifting ARF at other location in Suratgarh Yard to facilitate coaching terminal at Suratgarh Junction and Upgradation/ Augmentation/Creation of Disaster management Rolling Stock maintenance facility at Suratgarh over BKN Div.
06-EL-BKN-E-Tender-26-27R~NWR
06-EL-BKN-E-Tender-26-27R
Open
Works - General
18 Months
Bikaner, Rajasthan
₹0
₹10.1 L
21 Aug 2026
21 Aug 2026
31 Aug 2026
545 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,14,88,412 | ||
| — | 2.00 | — | — | ||
| Supply / Preparing of drawing in Auto CAD (Original + 2 copies) on Jet Matt paper of 85/90 GSM showing over all electrical installation at site as per requirement and as per specification. | — | — | — | 7,112 | |
| — | 1.00 | — | — | ||
| A) Supply, installation, testing & commissioning of complete uni pack CSS-1 of with 01 no. 11 kV 500 kVA dry type transformer, HT switchgear with 03 VCB arrangement (01 I/C + 02 O/G), GI enclosure and LT distribution board with tie-feeder as per specification. B) Supply, installation, testing & commissioning of complete uni pack CSS-2 of with 01 no. 11 kV 500KVA dry type transformer, HT received from CSS-1, GI enclosure and LT distribution board with tie-feeder and 150 KVAR APFC panel as per specification. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 52,68,565 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of 11 kV, 630A, 21kA / 3 sec, outdoor type, extensible type Ring Main Unit (RMU) with suitable RCC foundation with 2 Nos. Load Break Switch (LBS) & 1 No. Vacuum Circuit Breaker (VCB) as per Specification. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 7,55,288 | |
| — | 1.00 | — | — | ||
| Supply of material, fabrication & erection of 'H' pole (Double pole) with I section M.S. beam ISHB 150, size 150mm x 150mm of length 10.0 Mtrs. with required foundation and painting etc. as per specification. | — | — | — | 46,785 | |
| — | 1.00 | — | — | ||
| Supply, fixing, connecting and charging of off load type Gang operated 3 pole switch suitable for 400 Amp 11 KV 3 phase central post rotating double break isolator complete with MS hardware copper moving and fixed contact, assembly of 9 nos. pin insulator, GI pipe of suitable length of operation including 3 nos. vertical mounted 11 kV horn gap fuse set/dropout 11 kV barrel drop out fuses mounted on 6 no. pin insulator as per standard spec. on existing H pole. | — | — | — | 16,207 | |
| — | 1.00 | — | — | ||
| Design, Supply, install, testing & commissioning of LT panel with 2X800Amp ACB as incomer & 4X400Amp, 4-Pole MCCB, 2X250Amp, 4 Pole MCCB and 4x100, 4-Pole MCCB, as outgoing with suitable capacity CT, Digital Ammeter, Voltmeter, Energy meter & selector Switches as per specification. (Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 4,49,649 | |
| — | 2.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of LT panel, medium voltage made by 2 mm CRCA sheet with- (a) Incoming 1 x 400 amps.4 pole MCCB with adj .overload and adj. short circuit trip unit and breaking cap 50 kA (Ics = 100% Icu). (b) Outgoing 2 x 200 and 2 x 160 amps. 4 pole MCCB with adjustable overload and adj. short circuit trip unit and 2 x 125 amps. 4 pole MCCB with adjustable overload and fixed short circuit trip unit breaking cap. 36kA (Ics = 100% Icu) with proper foundation work as per technical specification. (Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 2,92,140 | |
| — | 2.00 | — | — | ||
| Design, supply, fixing & commissioning of LT panel made by 2 mm CRCA sheet with 1 no. Incomer 250A MCCB, 36kA and Outgoing - 2 no. 4 pole MCCB 125A,16kA.,2 nos. 4 pole MCCB 63A,16kA and 2 nos. 4 pole MCCB 40A,16kA All MCCB should be adjustable over load 80% to 100% & Adjustable short circuit, Ics = 100% Ics with meter & indication LED, copper bus bar etc. with foundation as per spec. (Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 2,33,544 | |
| — | 7.00 | — | — | ||
| Supply fixing, testing commissioning of 15 kVA 415/48 Volt 3 phase copper wound VPI dry type transformer with proper enclosure as per requirements.(Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 4,48,742 | |
| — | 2.00 | — | — | ||
| Supply, install, testing and commissioning of 2 kVA copper wound single phase step down transformer 230V/40-72 Volts outdoor type as per specification. | — | — | — | 15,718 | |
| — | 120.00 | — | — | ||
| Supply & erection of 5 m high with double arm model no. BOP-5030 of Bajaj or similar, pole shaft material S355J0 or equivalent as per IS, hot dip galvanized steel octagonal pole with galvanized base plate of 200x200x12 mm, junction box with 6 Amp. MCB and stud terminals (for mounting inside the base compartment of pole), foundation bolt size 4x16mm dia. 600 mm in length including excavation and making foundation as per spec. and drawing. It shall be galvanized internally and externally by single dipping method. The pole and foundation shall be made as per specification and attached drawing. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 9,73,680 | |
| — | 20.00 | — | — | ||
| Supply and fixing of 250 Watt LED Flood light with required fixing arrangement outdoor type, Aluminum dia cast housing instant start Input operating Voltage range and frequency 90 to 300 Volts AC at 50 Hz+/-2 Hz, IP 65, Minimum Lumen 13500 IN 5700 or more color temperature with CRI more than 85, Power Factor 0.95, Working life for LED (Minimum 50,000 burning hours at L70 lumen maintenance, THD should be less than 20 , make PHILIPS / EDISON / OREVA / PYROTECH / SURYA /CG / OSRAM / BAJAJ / HAVELLS / HALONIX or similar same as per tech spec. | — | — | — | 48,300 | |
| — | 760.00 | — | — | ||
| PIT LIGHTING: Design, fabrication, supply, erection, testing & commissioning of LED based luminaire having input voltage 40V-72V AC, frequency 50/60 Hz, Input Power 16 watt with IP- 67 enclosure & Impact protection IK-10 with High brightness, high intensity with efficiency of 130 lumens/watt & with proper ON/OFF and locking arrangements. The luminaries shall be designed such a way to illuminate the under frame of the coach and path lighting of pit line. The cubicle shall be fabricated with MS sheet / Poly carbonate body with high built of epoxy coating, heat resistive up to 70 degree centigrade complete with weather proof and rust proof. Fixture shall be as per specifications. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 30,23,280 | |
| — | 760.00 | — | — | ||
| Cat walk lights: Design, fabrication, supply, erection, testing &commissioning of LED based Cat walk lighting luminaires complete, with input wattage of 22W suitable to work on 40V-72V AC supply with all connected accessories & proper ON/OFF and locking arrangements. Luminaries should be Ingress protection IP- 67 & Impact protection IK10. The cubicle shall be fabricated with MS sheet / Poly carbonate body with high built of epoxy coating, heat resistive up to 70 degree centigrade complete with weather proof and rust proof. Fixture shall be IRGOLD-B1 of M/s Goldwyn Limited or equivalent. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 34,75,480 | |
| — | 50.00 | — | — | ||
| Supply, installation, testing and commissioning (with foundation/supporting structure) of 200 W LED circular highbay with toughened glass fitting with glass cover suspended type [IP-66] with additional safety chain, luminaries has efficacy upto 130 lm/W with10kV SPD as similar to cat no. CIP-325-200-57-60D-HL5-LM-NSG of Crompton or equivalent with suitable junction box for looping. Make shall be as per specification and as per site requirements. Make PHILIPS / EDISON / OREVA / PYROTECH / SURYA /CG / OSRAM / BAJAJ / HAVELLS / HALONIX or similar same as per tech spec. (Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 4,72,500 | |
| — | 70.00 | — | — | ||
| Supplying, fixing and commissioning of street light fitting accessories e.g. GI pipe of bore 25mm or as suitable for street light, clamps, nuts, bolts, cable, etc. as per instruction of site engineer. | — | — | — | 9,240 | |
| — | 320.00 | — | — | ||
| Fixing of LED Street light / HM flood light outdoor type with all its accessories as per site requirement and instructions of Railway supervisor. | — | — | — | 35,520 | |
| — | 2000.00 | — | — | ||
| Supplying and drawing FR PVC insulated & unsheathed flexible 3 Core X 1.5sqmm PVC Unarmored copper cable ISI marked (IS:694) of 1.1 kV grade in existing surface or recessed conduit/casing capping including making connections etc. as required. | — | — | — | 1,02,000 | |
| — | 4000.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4x16 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe with transportation as per spec. | — | — | — | 32,000 | |
| — | 3000.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4x50 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe with transportation as per spec | — | — | — | 24,000 | |
| — | 2000.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4x70 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe with transportation as per spec. | — | — | — | 32,000 | |
| — | 3500.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4x120 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe with transportation as per spec. | — | — | — | 70,000 | |
| — | 2000.00 | — | — | ||
| Laying, connecting, testing and commissioning of 2x120 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe with transportation as per spec. | — | — | — | 26,000 | |
| — | 2500.00 | — | — | ||
| Laying, connecting, testing and commissioning of 4x185 sqmm, 1.1KV grade, LT PVC insulated PVC outer sheathed aluminium conductor armoured cable in trench/pipe with transportation as per spec. | — | — | — | 47,500 | |
| — | 500.00 | — | — | ||
| Laying, testing & commissioning of 11KV / 33 KV XLPE cable in air / ground / in trench / spun / HDPE pipe, with transportation from main depot to required site, and as per specification enclosed. Note: - HT cable will be issued / provided by Railways. The contractor will be responsible for collection of cables from the Elect Maintenance / Works Depot including loading, unloading, transportation and return of un-used cables back at Depot. Cost of these provisions is deemed to be included in this item. | — | — | — | 68,500 | |
| — | 2500.00 | — | — | ||
| Transportation, Laying, testing and commissioning of LT XLPE cable 4c/1c x400/630 Sqmm all as per detailed specifications and as directed. .Note:- LT UG cable will be issued by Railways. The contractor will be responsible for collection of cables from the Elect Maintenance / Works Depot including loading, unloading, transportation and return of un-used cables back at Depot. Cost of these provisions is deemed to be included in the quoted rate for this item. | — | — | — | 97,500 | |
| — | 20.00 | — | — | ||
| Supply and fixing of crimped sockets/lugs bimetallic / Aluminium for 4C/1C x 400/630 Sqmm cable all as specified and as directed. | — | — | — | 5,040 | |
| — | 7700.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness 3 mm, PN 6, PE 80 as per requirement. (Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 4,85,100 | |
| — | 7700.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 50 mm dia, wall thickness 3 mm, under the road. The work involves laying of HDPE pipe along with transportation. | — | — | — | 61,600 | |
| — | 2200.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, PN 6, PE 80 as per requirement. (Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 1,91,400 | |
| — | 2200.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 75/80 mm dia, under the road. The work involves laying of HDPE pipe with transportation. | — | — | — | 24,200 | |
| — | 2400.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 110 mm dia, PN-6, PE-80, as per requirement. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 8,20,800 | |
| — | 2400.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 110 mm dia, PN-6, PE-80, under the road. The work involves laying of HDPE pipe with transportation. | — | — | — | 31,200 | |
| — | 500.00 | — | — | ||
| Supply of HDPE pipe conforming to IS 4984:2016, 160 mm dia, wall, PN 6, PE 80, as per requirement. (Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 2,40,500 | |
| — | 500.00 | — | — | ||
| Laying of HDPE pipe conforming to IS 4984:2016, 160 mm dia, under the road. The work involves laying of HDPE pipe along with transportation. | — | — | — | 4,000 | |
| — | 14800.00 | — | — | ||
| Digging and filling of trench size 0.4 x 0.8 mtr as per spec. (trench work may be on Kachha/ Pakka land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer. | — | — | — | 5,62,400 | |
| — | 450.00 | — | — | ||
| Digging and filling of trench size 0.4 x 1.2 mtr as per spec. (trench work may be on Kachha/ Pakka land and all type of soil as per site requirement and without protective layer of brick) Surface of trench shall be made good in all respect and satisfaction of site engineer | — | — | — | 23,400 | |
| — | 50.00 | — | — | ||
| Cutting of cement concrete floors (PCC / RCC), any type / depth as required for laying of UG cables in trenches and disposing off the excavated material as directed including refilling the trenches in layers and consolidating complete all as specified and directed. Note:- Providing barricading and danger lighting around the excavated areas safety precaution is a mandatory requirement and cost of this provision, wherever required, is deemed to be included in the quoted rate of this item | — | — | — | 55,800 | |
| — | 300.00 | — | — | ||
| Supply & providing of cable marker. The cable marker shall be made of MS Sheet 1.5mm thick size 150X100mm welded with 12mm dia MS rod 85 cm long. The lower end of rod should be turned in hooks shape and attached with the cable at the time of laying. | — | — | — | 48,600 | |
| — | 500.00 | — | — | ||
| Drilling of horizontal bore below Track/Road by pushing method (trenchless technology) for laying of RCC/HDPE/DWC pipe of various sizes up to 200 mm dia. in presence of Railway representative taking all necessary safety precautions related track and movement of trains. Horizontal boring will be done at minimum 1.5 Mtr. Below from ground level at railway track portion. | — | — | — | 5,76,500 | |
| — | 100.00 | — | — | ||
| Supply of material and laying of perforated GI cable tray of size 200mm X 50 mm size & 2mm thick, with cover and all fixing arrangements as per specification and as per site requirement. | — | — | — | 50,100 | |
| — | 1500.00 | — | — | ||
| Supply, erection and commissioning of cable tray made from MS angle 35x35x5mm and MS flat 35x5mm as per technical specification. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 6,57,000 | |
| — | 18.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 38 mm dia. Pipe should be of reputed make and as per tech. spec. | — | — | — | 2,358 | |
| — | 18.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 50 mm dia. Pipe should be of reputed make and as per tech. spec. | — | — | — | 3,456 | |
| — | 18.00 | — | — | ||
| Supply, laying and fixing of GI pipe medium "B" class (Blue) confirming to IS 1239 part-I for passing incoming and outgoing cable from ground through it size 100 mm dia. Pipe should be of reputed make and as per tech. spec. | — | — | — | 10,710 | |
| — | 550.00 | — | — | ||
| Supply of material and wiring of LP/TP/FP/Ex.Fan point with 1.5 sqmm PVC single core multi-stranded copper wire insulated concealed in stone/brick masonry wall in 19/20 mm PVC conduit with 1.5sqmm PVC wire insulated copper for earth wire 1-way/2-way switch 5/6A as required and good quality ceiling rose including connection (with modular switch, celling rose, PVC conduit & chase work) as per spec. | — | — | — | 2,02,950 | |
| — | 200.00 | — | — | ||
| Supply and fixing 5/6A Socket, modular 3/5-pin 230V including modular switch and with modular board and wiring with 2.5sqmm PVC CU cable as per spec. | — | — | — | 47,800 | |
| — | 70.00 | — | — | ||
| Supply and fixing 15/16A Socket, modular 5/6-pin 230V including modular switch and with modular board and wiring with 4.0 sqmm PVC CU cable as per spec. | — | — | — | 18,830 | |
| — | 50.00 | — | — | ||
| Supply and fixing 2 modular switch board plate for fixing of modular switches -Socket with sheet metal box of good quality concealed fixing of MS/PVC as per site spec | — | — | — | 5,550 | |
| — | 70.00 | — | — | ||
| Supply and fixing 4 module switch board plate for fixing of modular switches -Socket with sheet metal box of good quality concealed fixing of MS /PVC as per site spec | — | — | — | 11,690 | |
| — | 80.00 | — | — | ||
| Supply and fixing 8 module switch board plate for fixing of modular switches -Socket with sheet metal box of good quality concealed fixing of MS /PVC as per site spec | — | — | — | 22,160 | |
| — | 50.00 | — | — | ||
| Supply and fixing 12 module switch board plate for fixing of modular switches -Socket with sheet metal box of good quality concealed fixing of MS /PVC as per site spec | — | — | — | 15,300 | |
| — | 2000.00 | — | — | ||
| Wiring of sub-main with 2x2.5sqmm PVC insulated, single core,multi-stranded copper wire in PVC conduit concealed and 2.5sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec.This item includes PVC conduit (25 MM) and chase as per requirement. | — | — | — | 1,34,000 | |
| — | 2500.00 | — | — | ||
| Wiring of sub-main with 2x4sqmm PVC insulated, single core,multi-stranded copper wire in PVC conduit concealed and 4.0sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec. This item includes PVC conduit (25 MM) and chase as per requirement. | — | — | — | 2,87,500 | |
| — | 2000.00 | — | — | ||
| Wiring of sub-main with 2x6sqmm PVC insulated, single core,multi-stranded copper wire in PVC conduit concealed and 6.0sqmm PVC insulated, single core, multi-stranded copper wire for earth wire as per spec.This item includes PVC conduit (25 MM) and chase as per requirement. | — | — | — | 2,50,000 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing and commissioning of SPN DB 12 Way with suitable IP protection having 1 No. RCBO 40 A Cap., sensitivity 30 mA in the incoming and in outgoing 06 Nos. 10-32 Amp. SP MCB, 10 kA, 'C' curve, 10KA as required with bus bar, neutral bar and necessary wire sets as per specification. | — | — | — | 33,285 | |
| — | 150.00 | — | — | ||
| Supply & wiring of light/fan point in covered shed with 1.5sq.mm multistrand copper, PVC insulated, single core wire in PVC 19/20 mm ISI PVC conduit pipe mounted on structure/ shed with ceiling rose 5 Amp. mounted on wooden block/PVC junction box as per specification. | — | — | — | 28,050 | |
| — | 4000.00 | — | — | ||
| Supplying and drawing 6.0 sq. mm PVC insulated multistrand copper conductor cable as submain and 1.5 sq. mm PVC insulated multistrand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing capping. Wire should be of reputed make. | — | — | — | 2,20,000 | |
| — | 500.00 | — | — | ||
| Supply and fixing of PVC conduit/casing capping (as per instruction of site supervisor) and its accessories, size 25 mm, thickness 1.6 mm as per IS:9537 Pt-III. | — | — | — | 20,000 | |
| — | 700.00 | — | — | ||
| Supply and fixing of Rigid PVC conduit size 25 mm, thickness 2.0mm and its accessories, as per IS:9537 High mechanical stress (HMS) type including fixing accessories. Anchor or similar of reputed make. | — | — | — | 60,900 | |
| — | 200.00 | — | — | ||
| Making and filling of chase for 25 mm dia PVC/MS conduit. Surface of chase shall be made good in all respect and satisfaction of engineer incharge. | — | — | — | 1,600 | |
| — | 4000.00 | — | — | ||
| Supplying and drawing 4.0 sq. mm PVC insulated multistrand copper conductor cable as submain and 1.5 sq. mm PVC insulated multistrand earth copper cable voltage grade 1.1 kV as earthing wire conforming to IS: 694-1990 in existing conduit/casing capping. Wire should be of reputed make. | — | — | — | 1,64,000 | |
| — | 2600.00 | — | — | ||
| Supply and fixing of HOT DIP GALVANISED RIGID STEEL CONDUIT PIPES (HIGH PROTECTION) and its complete accessories, size 25 mm dia, thickness 1.6 mm as per IS 9537 part II and with galvanized clamps & GI junction boxes as per requirement. The box should have IP-67 protection.(Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 4,81,000 | |
| — | 400.00 | — | — | ||
| Fixing of LED four feet fitting complete with tube. | — | — | — | 12,000 | |
| — | 40.00 | — | — | ||
| Supply and fixing, testing and commissioning of LED Panel Light, 36 watt size 2'x2', IP 54 protection to avoid ingress of dust and insects. LED panel light shall be of reputed make. | — | — | — | 49,920 | |
| — | 120.00 | — | — | ||
| Supply of material and fixing of modular BLDC fan regulator 4-step and above (2- module) used for concealed modular wiring. The regulator is made of high-grade, UV-stabilized polycarbonate material, specifically designed to support all brands BLDC fans. | — | — | — | 55,560 | |
| — | 20.00 | — | — | ||
| Supply and fixing of blank plates (1-Module) used in concealed modular wiring. | — | — | — | 500 | |
| — | 120.00 | — | — | ||
| Supply and fixing of PVC Electric Ceiling Fan Box Optimum Quality used in Fan Installation as per site requirement. | — | — | — | 13,200 | |
| — | 120.00 | — | — | ||
| Fixing and commissioning of ceiling fan with nut bolt ensuring all safety aspects. Contractor is responsible for falling of fan within a period of 12 month. | — | — | — | 2,880 | |
| — | 10.00 | — | — | ||
| Supply and fixing of Ceiling rose complete. Ceiling rose should be of reputed make and as per tech. spec. | — | — | — | 250 | |
| — | 10.00 | — | — | ||
| Supplying, fixing and commissioning of Air circulator fan 24' of reputed make. It includes installation of fan along with required accessories as per site requirements. | — | — | — | 89,990 | |
| — | 10.00 | — | — | ||
| Supply and fixing of single phase Double Door MCB DB SP (4+2) way, with DP MCB 40 amp 'C' series one number & SP MCB 32/25 amp. 'C' series four number. Breaking capacity not less than 10 KA. MCB and DB should be as per tech spec. and of same make. | — | — | — | 26,870 | |
| — | 3.00 | — | — | ||
| Supply and fixing of TPN MCCB double door DB 12+2 way with 4P 100A (25 kA) MCCB-1 no., 2P 63A, 100 mA RCCB-3 no. and 2P 25A 'C' series 10 kA MCB-18 nos. MCCB, MCB, RCCB and DB should be as per tech spec. and of same make. | — | — | — | 78,312 | |
| — | 10.00 | — | — | ||
| Supply and fixing of Double Door MCB TPN DB SP (8+12 module), neutral and earth link, 4 way with one no four pole MCB 63 amp, one no Four Pole RCCB 63 amp 30 mA and twelve no SP MCB 32/25/16/10/6 amp. 'C' series. Breaking capacity not less than 10 kA. MCB, RCCB and DB should be as per tech spec. and of same make. | — | — | — | 90,650 | |
| — | 25.00 | — | — | ||
| Supply and fixing of junction box size 390x305x170mm comprising of SMP/FRP material with rubber gasket, locking arrangement, zinc passivated earth bolt, etc. similar to Sintax model no. GSJB 3525 or similar with 4 no. aluminum busbar cap 200 Amp. Suitable for 415 volt supply requirement. The box shall be fixed robustly with clamps at pole / wall as per requirement. All the material should be of good quality and as per tech. spec. | — | — | — | 50,700 | |
| — | 10.00 | — | — | ||
| Supply and fixing of junction box size 500x450x100mm comprising of sheet steel 2mm thick, 60 micron powder coating/two coats of primer and finished by enamel paint - grey shade, gland plates, neoprene EDPM/rubber gasket, locking arrangement, zinc passivated earth bolt, canopy etc. 4 no. aluminum busbar cap 200 Amp., suitable for 415 volt supply requirement. The box shall be robust clamps at pole / wall as per requirement. | — | — | — | 34,280 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of fabricated feeder pillar distribution box made of MS sheet 1.6 mm thick size 600mmX300mmX600mm with suitable MS stand copper bus bar of 200 Amp. Capacity and 2X63 Amp MCB four pole as per technical specification. | — | — | — | 11,566 | |
| — | 55.00 | — | — | ||
| Supply, fixing and commissioning of Battery charging board/box emergency terminal box two ways outdoor type as per RDSO Drg. No. SKE-3929 as per specifications. | — | — | — | 54,780 | |
| — | 55.00 | — | — | ||
| Design, manufacturing, supplying and fixing of three phase 440 V pre-cooling points complete with 3P 80A MCCB, 63 A 5 pin coupler (male + female) and accessories as per specification and drawing. MCCB and coupler should be of reputed make and as per tech. spec. This item shall be approved by Railway before installation (Inspection Clause : By RITES at factory Premises ) | — | — | — | 5,25,470 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing and commissioning of Battery charger rectifier set for input of 415 V 3 Phase, 50 Hz, AC and output of 110V-150V DC at 200 Amps. As per RDSOs latest specifications. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 12,58,600 | |
| — | 55.00 | — | — | ||
| Supply, installation, testing & commissioning of (5 pin) plug & socket 63A, 415V, (3P + N + E) with 63A MCB for ON/OFF for welding with enclosure as per site requirements and specification. This item shall be approved by Railway before installation. | — | — | — | 2,05,205 | |
| — | 1.00 | — | — | ||
| Design, manufacturing, supply, testing, erection and commissioning of 6 way MCCB incomer & MCCB outgoing DB panel , fabricated from 1.6mm thick CRCA sheet, powder coated with IP 42 degree of protection, complete with 250 amp copper busbar, (Legrand cat part no. SD 2025 or similar), having provision for incomer 160 Amp, 4 pole 36kA MCCB - 1 no. and Outgoing - 63 amp 4 pole 16kA MCCB - 4 nos. Panel shall be manufactured from CPRI tested firm or should be of reputed switchgear manufacturer's make with foundation work and as per tech. spec. | — | — | — | 45,037 | |
| — | 1.00 | — | — | ||
| Supply, fixing and commissioning of 250 amps. 4 pole MCCB with adjustable thermal & fix magnetic trip unit, breaking cap 36 kA (min.) as incoming for DB above. | — | — | — | 13,899 | |
| — | 2.00 | — | — | ||
| Supply, fixing and commissioning of 4 pole 125 amp. MCCB adjustable thermal magnetic trip unit, breaking cap. 16 kA (min.) (Legrand cat. no. 625327 or similar of reputed make) as outgoing for DB. MCCB should be of reputed make and as per tech. spec. | — | — | — | 10,904 | |
| — | 2.00 | — | — | ||
| Supply, fixing and commissioning of 4 pole 100 amp. MCCB adjustable thermal magnetic trip unit, breaking cap. 16 kA (min.) (Legrand cat. no. 625327 or similar of reputed make) as outgoing for DB. MCCB should be of reputed make and as per tech. spec. | — | — | — | 8,356 | |
| — | 3.00 | — | — | ||
| Supply, erection, testing and commissioning of 16 Mtrs high mast shaft totally hot dip galvanized and suitable for wind velocity as per IS 875 part-3, design and casting of suitable foundation with M-20 concrete for the 16mtr high mast having the safe soil bearing capacity at site as 10T/sqmtr. at 2 meter depth including supply of foundation bolts manufactured from special steel along with nuts, washers and anchor plates and templates. Are required make: Bajaj/Philips or similar. The mast shall have one longitudinal weld and single dipping (hot dip galvanized) per section (as per specification attached). (Inspection Clause : By RITES at factory Premises ) | — | — | — | 5,98,488 | |
| — | 3.00 | — | — | ||
| Supply, fixing and commissioning of Switching Panel with electromechanical time switch with two daily dial / electronic time switch & two suitably rated contactors for operating 6 / 8 X 150 / 250 / 400 W LED flood lamps, suitable control gear for operation of lowering and lifting mechanism of 16 mtr mast necessary cable etc. for commissioning of the Mast. All the accessories should be of reputed make and the switch also incorporates electronic over current trip and latch mechanism. The panel shall be of appropriate size with sufficient clearance for working during maintenance and it should be properly installed near high mast with proper foundation. Height of panel shall be kept minimum 500mm above the ground. | — | — | — | 27,657 | |
| — | 48.00 | — | — | ||
| Supply and fixing of 400W Flood light for high mast Input operating Voltage range and frequency 90 to 300 Volts AC at 50 Hz+/-2 Hz, Lumen/watt>/= 100 Lm/Watt, Power Factor 0.95, Working life for LED (Minimum 50,000 burning hours, Colour temperature=6000K(+/-500K). make PHILIPS / EDISON / OREVA / PYROTECH / SURYA /CG / OSRAM / BAJAJ / HAVELLS / HALONIX or similar same as per tech spec. (Inspection Clause : By Railway Representative at factory Premises) | — | — | — | 3,50,928 | |
| — | 6.00 | — | — | ||
| Supply and fixing of twin LED aviation light luminaires make Bajaj or similar comprising of aluminum housing with polycarbonate enclosure, (1 fitting per mast is necessary). | — | — | — | 23,784 | |
| — | 3.00 | — | — | ||
| Dismantling, relocating, re-fixing, erection, testing & commissioning of 12.5/16 meter high mast system along with all accessories as per site requirement to the satisfaction of Rly. representative. It includes design / casting of shallow foundation for high mast with M-20 concrete considering safe soil bearing capacity at site as 10T/sq.mtrs. at 2 mtrs. depth including supply of foundation bolts manufactured from spl. steel along with nuts, washers, anchor plates, templates. | — | — | — | 2,14,770 | |
| — | 3.00 | — | — | ||
| Supply and fixing or replacement of the hot dip galvanized head frame as capping unit for high mast shall be with close fitting guides and sleeves, three stops with PVC buffer for docking the luminaries carriage, cast aluminum pulley with stainless steel axle large enough to accommodate the stainless steel wire ropes and electric cable, canopy to cover the pulley's and with a provision to mount lighting finial. | — | — | — | 53,904 | |
| — | 3.00 | — | — | ||
| Supply and fixing/replacement of 1HP 3ph motor reversible, high powered power tool with operating mechanism, to be mounted in the base compartment of the high mast, coupled to the winch shall be supplied for raising and lowering of the luminaries carriage as optional item. | — | — | — | 31,107 | |
| — | 3.00 | — | — | ||
| Supply and fixing/replacement of double drum winch, suitable to operate by motor or handle, self-lubricating type by means of an oil bath, with grooved drum incorporating distortion free end termination shall be completely self-sustaining type, without the need for brake shoe, springs or clutches and shall have a ratio of 53:1 / 50:1 and minimum safe working load shall be not less than 250 Kg. | — | — | — | 99,102 | |
| — | 210.00 | — | — | ||
| Supply and fixing/replacement of stainless-steel wire ropes with 316/304 grade or similar shall be of 7/19 construction and diameter of 6 mm. The end construction of the ropes to the winch drum shall be fitted with talurit end thimbles shall be secured on ropes by compression splices and bulldog grips as required. | — | — | — | 45,150 | |
| — | 60.00 | — | — | ||
| Supply and fixing of ERP PVC sheathed copper cable 5/6 core 2.5 sqmm for high mast. | — | — | — | 24,120 | |
| — | 3.00 | — | — | ||
| Supply and replacement of junction box for top of high mast size and other items should be same as exiting junction box. | — | — | — | 4,092 | |
| — | 3.00 | — | — | ||
| Repairing of lowring and lifting mechanism of high mast. | — | — | — | 7,374 | |
| — | 3.00 | — | — | ||
| Supply, fixing and commissioning of Switching Panel with electromechanical time switch with two daily dial & two suitably rated contactors for operating 6/8/12 X400 W LED flood lamps, suitable control gear for operation of lowering and lifting mechanism of 12.5 mtr mast necessary cable etc. for commissioning of the Mast as per detailed specification and panal should be commission on proper foundation. All the accessories should be of reputed make and as per technical specification. | — | — | — | 28,275 | |
| — | 796.00 | — | — | ||
| Providing SH rail post 1.5 / 2.5 mtrs. Long for safety of highmast. Work includes cutting of 50@47<47K47@90 lbs capacity rails in pieces of desired length (1.5/2.5 mtrs.), digging of pit and erection of rail pole (Rails will be supplied by railway and is to be collected by contractor from concerned SSE). The rail pole shall be erected over a cement concrete bed (1:3:6) of 15 cm thickness and back filling of pit with excavated earth soil. The depth of the pit shall be 0.5 mtrs. or as directed by Site Engineer. These rail poles should be grouted properly | — | — | — | 8,23,860 | |
| — | 80.00 | — | — | ||
| Supply, installing, testing and commissioning earth electrode complete in all respect with perforated GI pipe medium "B" class (Blue) confirming to IS 1239 part-I length of 4 mtr., bore 50mm with all accessories like nut bolt, reducer nipple, wire meshed funnel and CC finished chamber covered by CI/RCC frame etc. Digging pit and refilling it with charcoal and salt in successive layers and connection with 25x3 mm GI strip as per IS:3043 and drawing and testing of earth resistance as reqd | — | — | — | 1,51,920 | |
| — | 100.00 | — | — | ||
| Supply, laying and fixing of 25 x 5 mm GI earth strip at 0.5 meter below ground level or on walls/poles / along pipes etc., including connection / termination with GI nut, bolt, washer etc. as required (jointing shall be done by overlapping and with 2 sets of GI nut bolt & spring washer spaced at 50 mm). Note:- Suitable GI saddles with screws shall be provided to secure earth strips run on walls /floors etc. | — | — | — | 14,900 | |
| — | 20.00 | — | — | ||
| Supply of unit maintenance free earth material as per latest specification. | — | — | — | 1,79,620 | |
| — | 20.00 | — | — | ||
| Installation of unit maintenance free earth as per latest specification. | — | — | — | 75,660 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 25A, double pole, four module, 30mA with Earth leakage, overload and short circuit protection as per relevant IS or IEC 61009 as per specification. | — | — | — | 7,137 | |
| — | 3.00 | — | — | ||
| Supply and fixing of double hinge type FRP outdoor box with transparent lid to accommodate DP/TP "C" series, MCBs of reputed make. | — | — | — | 2,913 | |
| — | 3.00 | — | — | ||
| Transportation installation testing and commissioning of water cooler including with water connection angle valve as per spec. | — | — | — | 7,746 | |
| — | 300.00 | — | — | ||
| Supply fabrication and fixing of MS cage made of suitable size1" 1 MS angle and MS jali to provide protection of Water cooler /electrical equipment with two nos of key locks & 2 nos hinges including one coat of red oxide and two coats of enamel paint along with fixing arrangement on existing wall/rail /pipe/foundation by nutbolt /clamp /washer etc. as specification | — | — | — | 20,700 | |
| — | 3.00 | — | — | ||
| Provision of suitable foundation of appropriate height with concrete and cement (size 1M x 1M) for water cooler as per site requirement and instructions of railway site supervisor. | — | — | — | 6,222 | |
| — | 8.00 | — | — | ||
| Supply of material, fabrication, installation and commissioning of Rolling in Examination lighting MS box of suitable dimension comprising of sheet steel 1.6mm thick, 60 micron powder coating - grey shade, gland plates, neoprene EDPM/rubber gasket, padlock arrangement, zinc passivated earth bolt, canopy etc. All material of should be of good quality. | — | — | — | 39,320 | |
| — | 16.00 | — | — | ||
| Supply and Fixing LED flood lights 30 W, outdoor type, Aluminum die cast housing, Instant Start, operating voltage 90 V-300 V AC IP 65, color temperature with CRI more than 85 and PF more than .95 , life of complete fixture has to be minimum 50,000 burning hours at L70 lumen maintenance. THD should be less than 20 as per make Oreva, Pyrotech, Philips, Surya, CG, Osram, Gear, Bajaj and Havells or similar. | — | — | — | 26,560 | |
| — | 3.00 | — | — | ||
| Installation of 1.5 ton AC with rating and all accessories including MS stand as per site requirement and instructions of railway representative. | — | — | — | 6,093 | |
| — | 3.00 | — | — | ||
| Supply and fixing of 20A SP C Type Mini Modular MCB 'C' series 3kA or more product is fitted in robust designed assembly plates smug fit on the wall dust Free Glossy Finish with Silver graphite/brass contacts, FR Grade nylon glass filled housing, Tripping characteristic C Curve, Voltage 240 V , 50 Hz AC. The MCBs conform to Standards: IEC 60898-1995 and IS/IEC 60898-1:2002 | — | — | — | 1,281 | |
| — | 319.00 | — | — | ||
| Supply and fixing CPVC Pipe SDR 11 Class1 20 mm size having thermal stability for hot and cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipes with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Rly supervisor with all accessories required for ac water drainage. Concealed work, including cutting chases and making good the walls etc. | — | — | — | 6,380 | |
| — | 2.00 | — | — | ||
| Supply & testing of 5 star rated submersible pump cap 20 HP discharge head 210 m, 360 LPM BEE approved. Make CG/KSB/Kirloskar/CRI/ Texmo/Duke/sabar. | — | — | — | 1,39,800 | |
| — | 30.00 | — | — | ||
| 3 meter Medium Carbon Steel Riser Pipe for submersible Pumps Nominal Bore of steel tubes 50mm to 70mm Category of steel tubes is Medium Hot dip Galvanized zinc coating on the tubes in accordance with IS4736 latest" with all its accessories. | — | — | — | 60,000 | |
| — | 2.00 | — | — | ||
| Supply, erecting, testing & commissioning of digital soft starter 18 kW ISI marked of reputed. | — | — | — | 93,206 | |
| — | 2.00 | — | — | ||
| Supplying, fixing ,testing & commissioning Automatic operation street light timing switch box having lighting control (on-off) through astronomical calculation and pre-wired with suitable size of contactors, copper conductor etc. at specified locations as per specification attached and similar to model no 04764 of LEGRAND make or Siemens / ABB with suitable enclosure | — | — | — | 43,150 | |
| — | 5.00 | — | — | ||
| Supply, install, test & commissioning of MCCB 4P, 40 A, 16kA Adjustable thermal adjustable magnetic trip unit as per specification. | — | — | — | 23,455 | |
| — | 5.00 | — | — | ||
| Supply and fixing of Metal enclosure for MCCBs of reputed make | — | — | — | 2,675 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of RCBO 32A, double pole, four module, 30mA with Earth leakage, overload and short circuit protection as per relevant IS or IEC 61009 as per spec | — | — | — | 12,410 | |
| — | 5.00 | — | — | ||
| Supply and fixing of 2/4/8 module metal enclosure for fixing of RCBO as per IEC 61439-3, Suitable for flush mounting and surface mounting with door for IP 54, similar to Legrand or any reputed make. | — | — | — | 3,080 | |
| — | 5.00 | — | — | ||
| Removal of existing Rail/Swage poles with overhead wire and all accessories from station area. Rail are to be cut 0.5m below the ground level & making the ground level good by suitable cement concrete and transportation of rail pole and all accessories with fitting etc. complete from site to place located at that station by concern SSE/Elect. | — | — | — | 2,825 | |
| — | 15.00 | — | — | ||
| Removal of existing Octagonal pole. & making the ground level good by suitable cement concrete and transportation of rail/swage/octagonal pole and all accessories with fitting etc. complete from the site to place located at the station by concern SSE/Elect. | — | — | — | 2,340 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of 100 kVAR 750 V Real Time Thyristor Switched Power Factor Correction System with7 % Harmonic Block Reactor as per specification. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 10,39,191 | |
| — | 1.00 | — | — | ||
| Design, fabrication, Supply, installation, testing and commissioning of outdoor type package substation(Compact Substation) with HT 11KV RMU comprising of 2 Nos of LBS of rating 630 A and 1 No of VCB of rating 630 A, motorized switchgears and SCADA compatibility, directly connected with 11kV/750 V, 1000 KVA copper wound dry type power distribution transformer and LT outgoing 1 No of 1000 A ACB (operating voltage750 V) Motorized, 50 KA, EDO type Microprocessor release, Shunt release, Under voltage release and E/F relay complete, with LT side SCADA compatibility and subject to approval from competent authority and as per detailed technical specifications of tender documents. The final commissioning of substation includes submission of all technical documents, literature, test certificates etc., as required including necessary arrangements for EIG inspection all as specified and directed. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 71,50,900 | |
| — | 80.00 | — | — | ||
| Material and labour for Construction of concrete masonry plinth below ground level with M10 concrete for compact substation with provision for HT and LT cable incoming/outgoing including excavation and refilling as required. Note: (i) The foundations drawings shall be submitted and got approved from Railways prior to commencement of work at site. (ii) Necessary form work, shuttering and finishing of surfaces are included in the scope of work and the quoted rates are deemed to be inclusive of this provision. | — | — | — | 4,66,160 | |
| — | 80.00 | — | — | ||
| Material and labour for Construction of concrete M20 masonry plinth above ground level with plastering for compact substation with provision for HT and LT cable incoming / outgoing all as specified. Note: (i) The foundations drawings shall be submitted and got approved from Railways prior to commencement of work at site. (ii) Necessary form work, shuttering and finishing of surfaces are included in the scope of work and the quoted rates are deemed to be inclusive of this provision. | — | — | — | 4,99,440 | |
| — | 1.00 | — | — | ||
| Fabrication, supply, fixing, testing and commissioning of HT Metering Panel 3 CT & 3 PT, for 3 phase 4wire metering with transparent cover TTB with 30 x 8 mm Copper Bus bars (HT metering Box fabricated out of 3 mm MS sheet duly epoxy powder coated) with load break switch (3 phase 4 wire DLMS compatible) CT 11 KV, ratio10/1 A (or as directed), 0.2 s class accuracy, 2.5 VA burden including necessary foundation all as specified and as per DISCOM approved specifications and drawings. | — | — | — | 2,62,940 | |
| — | 4.00 | — | — | ||
| Provision of 750 V, 3Phase Feeder Contactor for isolation of IV coupler input and ACB output as per RDSO specification. (Inspection Clause : By RITES at factory Premises ) | — | — | — | 9,00,900 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of LHB type socket assembly 500 amps, 750 Volts housed in stainless steel housing of size 3 feet x 2 feet x 2 feet, with one contactor AC series 630 Amp,750 Volt AC coil to ON/OFF set with fixing stand, thermal relay, LED RYB indicators, ON & OFF push buttons, ON & OFF indicators supported with appropriate DMC/SMC barriers to be fixed in cement concrete foundation. of material & excavation of the cable trench as per standard specification.conf. to RDSO spec no.RDSO/PE/Spec/AC/0177 (rev-(0)2013- or latest | — | — | — | 4,81,222 | |
| — | 100.00 | — | — | ||
| Supply and drawing of E Beam irradiated flexible cable single core size 120 sqmm with copper conductor working voltage above 750 V & up to 1.8kV/3.0 kV grade. As per RDSO spec ELRS/SPEC/ELC/0019 REV 3 of Feb. 2017 or latest, Make - RDSO approved only. | — | — | — | 1,18,300 | |
| — | 6.00 | — | — | ||
| Supply of UIC coupler plug as pe SCHALTBAU part no. - UIC ST 13P EO D2 or equivalent of M/S Harting suitable for HOG LHB power car as per RDSO/PE/MS/AC0051-2011 Rev-2 or latest accepted make - CHALTBAU or similar. | — | — | — | 72,480 | |
| — | 1.00 | — | — | ||
| Provision of 110 V 5 Amp. SMPS -550 Watt Input Voltage: AC 100 - 264V 50 / 60Hz Output Voltage: 110V DC, 5A Output voltage: Adjustment Range: ±20%, Protections: Overload / Over Voltage / Short Circuit, Auto-Recovery After Protection | — | — | — | 15,600 | |
| — | 100.00 | — | — | ||
| Supply of 16 core X 1 Sqmm Teflon insulated copper cable (PTFE) with PVC sheathed round type each core should be different colour, suitable for UIC control cable of HOG power car as per RDSO/PE/MS/AC/0051-2011 rev. 2 or latest Make - Geecore par no. HOR002422 JSSS1034 (PTFE/SCR/FRLS) or equivalent. | — | — | — | 43,500 | |
| — | 1.00 | — | — | ||
| Design & manufacturing of hand trolley made of Iron size 30"X30"X24" suitable for carrying coupler etc. | — | — | — | 9,750 | |
| — | 20.00 | — | — | ||
| Supply, installing, testing and commissioning of copper plate earthing with connection complete in all respect with copper plate size 60 x 60 x 0.315 cm. Digging pit and refilling it with charcoal and salt and connection by copper flat. Masonry enclosure of 40 x 40 x 30 cm.(inner), 12.5 cm. should be provided at the top of the pit as per drawing attached at annexure-IV and IS:3043. | — | — | — | 92,900 | |
| — | 100.00 | — | — | ||
| Supply, laying, connecting and testing of copper flat size 40 x 3.15 mm for connecting earth with equipment. | — | — | — | 44,400 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing, commissioning of heat shrinkable type cable boxes suitable for 3 core 11kV XLPE cable size of 120 to 185 mm sq. - indoor type. Item should be of reputed make and as per tech. spec. | — | — | — | 21,018 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing, commissioning of heat shrinkable type cable boxes suitable for 3 core 11kV XLPE cable size of 120 to 185 mm sq. - outdoor type. Item should be of reputed make and as per tech. spec. | — | — | — | 21,526 | |
| — | 4.00 | — | — | ||
| Supply & fixing of straight joint of LT cable size 6-16 sqmm of reputed make. | — | — | — | 5,444 | |
| — | 4.00 | — | — | ||
| Supply & fixing of straight joint of LT cable size 25-50 sqmm of reputed make. | — | — | — | 7,788 | |
| — | 4.00 | — | — | ||
| Supply & fixing of straight joint of LT cable size 70-150 sqmm of reputed make. | — | — | — | 8,544 | |
| — | 10.00 | — | — | ||
| Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia6 mm thick G.I. base plate including holes etc. complete as required. | — | — | — | 5,800 | |
| — | 15.00 | — | — | ||
| Jointing copper / G.I. tape (with another copper/ G I tape, base of the finial or any other metallic object) by riveting / nut bolting/sweating and soldering etc as required. | — | — | — | 1,905 | |
| — | 300.00 | — | — | ||
| Providing and fixing G.I. tape 20mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run) | — | — | — | 42,300 | |
| — | 200.00 | — | — | ||
| Providing and fixing G.I. tape 20mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run) | — | — | — | 44,200 | |
| — | 1.00 | — | — | ||
| — | 15.00 | — | — | ||
| — | 15.00 | — | — | ||
| — | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
06of26-27R.pdf
ATTACHMENT
UpdatedGCCACSupto11.pdf
ATTACHMENT
JPOforprotectionofSTCables.pdf JPO for Protection of Cables
ATTACHMENT
RBSIGNAGESPOLICYPART-1.pdf RB Signage Policy Part 1
ATTACHMENT
RBSIGNAGESPOLICYPART-2.pdf RB Signage Policy Part 2
ATTACHMENT
JPOforprotectionofSTCables.pdf
ATTACHMENT
RBSIGNAGESPOLICYPART-1.pdf
ATTACHMENT
RBSIGNAGESPOLICYPART-2.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].