| 1 | L1₹35.9 LAccepted-AOC | L1 | Accepted-AOC QUOTED RATES LOWEST | |
| 2 | L2₹37.0 L+₹7,250 (0.20%)Rejected-Finance FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | L2 | Rejected-Finance Quoted amount neither lowest nor competitive | |
| 3 | L3₹37.9 L+₹96,990 (2.63%)Rejected-Finance | L3 | Rejected-Finance Quoted amount neither lowest nor competitive | |
| 4 | L4₹37.9 L+₹1.1 L (2.86%)Rejected-Finance FLAT NO 330 PKT 1 SECTOR 1 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L4 | Rejected-Finance Quoted amount neither lowest nor competitive | |
| 5 | L5₹40.9 L+₹4.0 L (10.8%)Rejected-Finance | L5 | Rejected-Finance Quoted amount neither lowest nor competitive |
Tender Value
₹58.4 L
EMD Value
₹1.1 L
Closing Date
23 Jul 2020, 5:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT-10
SPECIAL REPAIR TO EXISTING WIRING INFRASTRUCTURE FOR STREET LIGHT AND SECURITY LIGHTS AT HIRANKUDANA UNDER GE NORTH DELHI CANTT 10
2020_MES_355610_1
CWE/D-15/2020-21
Open Tender
Civil Works
Item Rate
180 days
Delhi Cantt
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE NORTH DELHI CANTT
₹1.1 L
Yes
19 Aug 2020
25 Jun 2020
24 Jul 2020
25 Jun 2020
23 Jul 2020
18 Jul 2020
Amount
Excavation in trenches in soft/Loose soil, not exceeding 1.5m depth and not exceeding 1.5m wide and getting out complete all as specified and directed
Returning & filling including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil complete all as specified and directed
Removal of excavated material not exceeding 50 meters and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed
M&L in repair LED street light fittings 60 watt, made up of of pressure die cast aluminium housing with high power LED as lighting in alunimium PDC housing with heat resistant thughened galss with IP 66 protection and connectioncomplete all as specified and directed
M&L for steel tubular electric pole swaged type, 410-SP-55 (11 metre long) with cast iron base plate, final taper plug, bolts, nuts & screws including painting of pole with two coats of aluminium paint over a coat of red oxide primer including painting of 30 cm wide yellow and black bands 3 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block and making hole for drawing of street light wire complete all as specified & directed (Note : Excavation, PCC for foundation, coping shall be measured and paid seperately) complete all as specified and directed
Supplying & laying cable XLPE (LT) insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor incl making connection with provision of glands/thimbles etc complete all as specified and directed of following size :-
50 Sqmm x 3.5 core
35 Sqmm x 3.5 Core
25 Sqmm x 3.5 core
16 Sqmm x 4 core
10 Sqmm x 4 Core
M&L for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed
Supply and laying sub class 'B' bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed
M&L in repair of LED flood light 150 watt/160 watt, rectangular with high luminous efficiency with front toughened galss, protected to IP-66 complete and fitted on existing pole having height almost 11 to 13 mtr and connection complete all as specified and directed
Supply and installation of LT panel board, 415 volt, AC, 3 phase, 50 Hz, factory made, outdoor type, floor mounted, double door, front and rear opening, with conopy roof extended on all four faces, locking arrangement, made out of 3 mm thick CRCA sheet for main frame, doors, and cable entry plate with 2mm thick plate of mountings, bottom support by MS channel 75 MC fixed in PCC (1:2:4) height 450mm from ground level, cable entry from boltom side, with powder coated painted, LT panel should have proper spacing to accomdoate and comprising the following accessories with internal wiring, glands to be provided at cable entriescomplete all as specified and directed :- (a) 4 Nos bus bars of high conductivity aluminium alloy, 3 Nos for phase (R,Y,B) rating 300 amp rating and 1 No for neutral rating 150 amp, mounted on DMC support with heat shrink sleeve - 01 set. (b) MCCB 4 pole 125 amp, 415 volts, 25 KA - 01 No (Incoming) (c) MCCB 4 pole 125 amp, 415 volts, 25 KA - 02 No (Outgoing) (d) MCCB 4 pole 63 amp, 415 volts, 16 KA - 01 No (Outgoing) (e) Street light timer switch comprising of 40 amp MCB TPN 'C' series, 10 KA, 3 pole contactor 63 amp and time switch (Make-L&T/Legrand)- 01 Set. (f) Indication lamp (R,Y,B), LED type - One set of three (g) Grouting of panel including PCC 1:2:4 type B1 & earth work complete Note :- (i) Layout design of LT panel shall be submitted to GE through Engineer-in-charge for approval before procurement. (ii) The contractor will submit test certificate and purchase voucher of the LT panel to Engr-in-charge before installation of panel at site. (iii) Make of LT Panel : L&T / ABB / Universal Switch Gear / Schneider / Simens / Crompton Greaves (iv) Make of MCCB / MCB :- L&T/ ABB / Legrand / Schneider
M&L for dismantling old unsv rusted pole any size complete all as directed
M&L for painting of existing steel tubular poles 9mtr to 11 mtr long including clamps, cross arms etc with two coat of aluminium paint and two coat of synthetic enamelled paint in yellow & black bands 30 cm up to 1.5 mtr above the ground level including preparation of steel surfaces complete all as specified and directed
M&L for PCC (1;3;6) type C-2 using 40 mm graded stone aggregate as in the foundatins or coping of electric poles stays assembly including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed
M&L for PCC (1;3;6) type C-1 using 20 mm graded stone aggregate as in the foundatins or coping of electric poles stays assembly including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed
M&L for heavy duty HDPE double wall corrugated flexible pipe, 50mm dia, for drawing LT XLPE cable in coping/ foundation of pole complete all as specified and directed
M&L for loop junction box, outdoor type, size 30cmx20cmX15cm, made out of engineering plastic one piece moulding type, bus bar rating 63 amps 4 strips aluminium with bus bar mounting colour R, Y, B, N on DMC unbreakable insulator with cable entry main supply from bottom side and pole light connection from back side, simens grey colout, shock proof, rust proof, fire retardant, having front opening and locking arrangement with MCB SP 10 amps - 01 No, box duly fixed on the pole with flat iron clamp of size 25 mmX3mm with nuts& bolts complete all as specified and directed (Note : Cost of incoming& outgoing cable lugs & glands of suitable size deemed to be included in the quoted rate)complete all as specified and directed
M&L for earthing with Galvanised Steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground vertically at a depth not less than 2.25metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using Galvanised strip of size 25x4mm as earthing lead (upto the body of the equipment) by means of bolts, nuts, check nuts and washers made of galvanised iron and thimbles and protected by light grade 40mm dia GI pipe connected to main switch board or main control board and GI pipe medium grade 20mm bore for watering and including funnel , wire mesh , RCC pit cover and PCC chamber pit with PCC (1:3:6) type C-2 using 40mm graded stone aggregate, including excavation and earth work in any type of soil, returning, filling in soil and disposal of surplus soil to a distance not exceeding 50m all as specified and shown in electrical plate No 3 of SSR (Part-I) complete all as specified and directed
M&L earth continuity conductor or main earthing lead fixed to wall or buried in ground or drawn in conduit or fixed to pole for loop earthing etc. of GI earth strip size 25x4mm complete all as specified and directed
M&L for flexible three core copper conductor cable 1.5 Sqmm from Junction box to street light/flood light fitting complete all as specified and directed0
M &L for making hole below the road by drilling machine or hand drill without damaging road for inserting pipe upto 80 mm dia complete all as specified and directed(Note: GI pipe shall be measured & paid separately)
S & F GI tubing 80 mm, light grade, complete all as specified and directed
S & F GI pipe 50 mm light grade, complete all as specified and directed
S & F bracket for street light fitting, made out of GI Pipe, light grade, 40 mm bore, 1.2 mtr length, bending an angle 45 degree on pole incl 2 nos of MS clamps made out of 30 x 5 mm flat iron with nut bolt and washer complete all as specified and directed
NEERU ELECTRICALS
GULSHAN SINGH GHAI AND SON
The new hut furnitures
M/S Parshant Associates
M/S MG GROUP
M/s GANJOO AND CO
GAUTAM ELECTRIC WORKS
M/s Dhapola Elevator and Engineering
Saini Enterprises
M/S ANIL KUMAR
Surjit and Sons
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .