| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 CrAccepted-AOC 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹6.7 Cr Quoted ₹7.0 Cr | L1 | Accepted-AOC Being lowest tender |
| 2 | L2₹7.1 Cr+₹15.8 L (2.26%)Rejected-Finance | ₹7.1 Cr+₹15.8 L (2.26%) | L2 | Rejected-Finance Higher than lowest tender |
| 3 | L3₹7.8 Cr+₹82.4 L (11.8%)Rejected-Finance | ₹7.8 Cr+₹82.4 L (11.8%) | L3 | Rejected-Finance Higher than lowest tender |
| 4 | L4₹7.9 Cr+₹88.2 L (12.6%)Rejected-Finance | ₹7.9 Cr+₹88.2 L (12.6%) | L4 | Rejected-Finance Higher than lowest tender |
Tender Value
₹7.3 Cr
EMD Value
₹6.9 L
Closing Date
14 Mar 2022, 6:00 pmClosed
Brig Ajai Singh Chonker Chief Engineer
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD, KOLKATA-700019
ADDN ALTN AND REPLACEMENT OF BER LIFTS AT KOLKATA MIL STN
2022_MES_509778_1
89049/E8
Open Tender
Civil Works
Item Rate
365 days
GE ALIPORE KOLKATA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
GE ALIPORE KOLKATA
₹6.9 L
Yes
24 Mar 2022
22 Feb 2022
17 Mar 2022
22 Feb 2022
14 Mar 2022
1 Mar 2022
Amount
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises upto 4 storey complete all as specified and as directed.
All as per item No 1.00 above but 5 storey to 8 storey.
All as per item No 1.00 above but 9 storey to 12 storey.
M&L for coloured, glazed ceramic tiles size 450x300x 6-7mm thick, in dado/skirting etc, set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match, laid with and including over10 mm thick rendering in CM (1:4) upto 4 storey complete all as specified and directed.
All as per item No 4.00 above but 5 storey to 8 storey.
All as per item No 4.00 above but 9 storey to 12 storey.
M&L for light shade Vitrified ceramic tiles 9-10 mm thick (Sqr/ rectangular) Polished, area of each tiles n.exc. 0.36sqm, in floors etc. set and jointed in neat cement slurry over a bedding layer of scread bed 15 mm thick in CM 1:4 and pointed in white/colour cement to match upto 4 storey complete all as specified and directed.
All as per item No 7.00 above but 5 storey to 8 storey.
All as per item No 7.00 above but 9 storey to 12 storey.
M&L for Granite (of any type) tiles 16-18 mm thick for slab machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone over 15 mm thick screed bed in cement mortar 1:4 including grinding & polishing fixed in slab/steps upto 4 storey complete all as specified and directed. NOTE : Size of Granite slab type and texture shall be approved by GE.
All as per item No 10.00 above but 5 storey to 8 storey.
All as per item No 10.00 above but 9 storey to 12 storey.
M&L for Granite(of any type) tiles 18 mm thick for slab machine cut, bedded & jointed with grey cement slurry & pointed with white cement with admixture of pigment to match the shade of granite stone over 10 mm thick Plaster in cement mortar 1:4 including grinding & polishing fixed in steps, jambs, skirting, pillars, cooking plateforms, window cills upto 4 storey complete all as specified and directed.
All as per item No 13.00 above but 5 storey to 8 storey.
All as per item No 13.00 above but 9 storey to 12 storey.
M&L for 18-20 mm thck machine cut Kota Stone slab flooring set and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, laid over and including 15 mm thick screed bed in cement mortar (1:4) upto 4 storey complete all as specified and directed.
All as per item No 16.00 above but 5 storey to 8 storey.
All as per item No 16.00 above but 9 storey to 12 storey.
Chipping of unsound/weak concrete materials from slabs, beams, columns, lintel, chajja, fin , facia etc. by any means as directed by Engr-in-Charge including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign matrials, loose concrete/aggregate etc. and disposal of all debris out of MOD land for 25mm average thickness for slabs/Chajja upto 4 storey complete all as specified and directed.
All as per item No 19.00 above but 5 storey to 8 storey.
All as per item No 19.00 above but 9 storey to 12 storey.
All as per Item No 19.00 above but 50mm average thickness for beams/Lintel upto 4 storey.
All as per item No 22.00 but 5 storey to 8 storey.
All as per item No 22.00 but 9 storey to 12 storey.
All as per Item No 19.00 above but 60mm average thickness for Column upto 4 storey.
All as per item No 25.00 above but 5 storey to 8 storey.
All as per item No 25.00 above but 9 storey to 12 storey.
Add or deduct for every 10 mm thickness extra of Sch 'A' item No 19 above upto 4 storey complete all as specified and directed.
All as per item No 28.00 above but 5 storey to 8 storey
All as per item No 28.00 above but 9 storey to 12 storey
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap) by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surface upto 4 storey complete all as specified and directed.
All as per item No 31.00 above but 5 storey to 8 storey
All as per item No 31.00 above but 9 storey to 12 storey
M&L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm upto 4 storey complete all as specified and directed.
All as per item No 34.00 above but 5 storey to 8 storey
All as per item No 34.00 above but 9 storey to 12 storey
Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 upto 4 storey High complete all as specified and directed by Engr-in-charge.
All as per item No 37.00 above but 5 storey to 8 storey
All as per item No 37.00 above but 9 storey to 12 storey
M&L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed by Engr-in-charge. upto 12 mm dia bar upto 4 storey High.
All as per item No 40.00 above but 5 storey to 8 storey
All as per item No 40.00 above but 9 storey to 12 storey
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc. The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as specified and directed by Engr-in-Charge for 60 mm average thickness of Column, upto 4 storey High.
All as per item No 43.00 above but 5 storey to 8 storey
All as per item No 43.00 above but 9 storey to 12 storey
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc. The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as specified and directed by Engr-in-Charge for Add or deduct for every 10 mm thickness extra, upto 4 storey High.
All as per item No 46.00 above but 5 storey to 8 storey
All as per item No 46.00 above but 9 storey to 12 storey
Supply, mixing and application two component structural grade polymer modified reinstatement morter, where local spalling has taken place or shuttering is not possible. The morter can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 complete all as specified and directed by the Engr-in-charge upto 25 mm average thickness and upto 4 storey High. Make :- Sika/Fosroc NOTE :- Cement and sand morter in proportion of 1:2 graded coarse sand with polymer admixed in proportions approved by Engr-in-charge.
All as per item No 49.00 above but 5 storey to 8 storey
All as per item No 49.00 above but 9 storey to 12 storey
M&L for applying curing compound over concrete surfaces as per manufactures instruction complete all as specified and directed by Engr-in-charge upto 4 storey High.
All as per item No 52.00 above but 5 storey to 8 storey
All as per item No 52.00 above but 9 storey to 12 storey
M&L for hoisting, assembly and fixing of double layer steel scaffolding to external perimeter of building duly cross braced and properly aligned for the functional aspect and safety of the building including dismantling, shifting & removal from site upto 4 storey High complete all as specified and as directed by the Engineer-in-Charge. Note: - Elevational area of the scaffolding facing the building shall be measured for payment.
All as per item No 55.00 above but 5 storey to 8 storey
All as per item No 55.00 above but 9 storey to 12 storey
Supply and Application Cementitious Grouting Admixture with the Cement slurry at a dosage 225 ml per bag of cement and injecting with high pressure by a Pressure grouting Pump through non return PVC nozzles Prefix with rapid setting cementitious Plugging Mortar to fill all possible pores and gaps left within the old concrete mass. When the flow of grout stops or shows refusal or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick-setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surface upto 4 storey complete all as specified and as directed by the Engr-in-Charge.
All as per item No 58.00 above but 5 storey to 8 storey
All as per item No 58.00 above but 9 storey to 12 storey
Supply only Integral Liquid water proofing compound (ISI Mark) upto 4 storey High complete all as specified and directed.
All as per item No 61.00 above but 5 storey to 8 storey
All as per item No 61.00 above but 9 storey to 12 storey
M&L for cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregates) as in roof kerbs or mud stops, rounded or chamfered on edges mixed with integral water proofing compound upto 4 storey High complete all as specified and as directed by Engineer-in-charge.
Demolition of RCC of any description and in any position not otherwise specifically provided for upto 4 storey High complete all as directed.
All as per item No 65.00 above but 5 storey to 8 storey
All as per item No 65.00 above but 9 storey to 12 storey
M&L for providing PCC (1:3:6) type C2 (using 40mm graded stone aggrgates) as in foundation, fillings and mass concrete as in post or struts upto 4 storey High complete all as specified and directed.
All as per item No 68.00 above but 5 storey to 8 storey
All as per item No 68.00 above but 9 storey to 12 storey
M&L for RCC Type A-1, 1:1.5:3 (20 mm graded stone aggregates) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses and mass concrete upto 4 storey High complete all as specified and directed.
All as per item No 71.00 above but 5 storey to 8 storey
All as per item No 71.00 above but 9 storey to 12 storey
M&L for RCC Type A-1, 1:1.5:3 (20 mm graded stone aggregates) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete upto 4 storey High complete all as specified and directed.
All as per item No 74.00 above but 5 storey to 8 storey
All as per item No 74.00 above but 9 storey to 12 storey
M&L for RCC Type A1 1:1.5:3 (20 mm graded stone aggregates) in Columns, pillars, piers, posts and struts upto 4 storey High complete all as specified and directed.
All as per item No 77.00 above but 5 storey to 8 storey
All as per item No 77.00 above but 9 storey to 12 storey
M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips upto 4 storey High complete all as specified and as directed.
All as per item No 80.00 above but 5 storey to 8 storey
All as per item No 80.00 above but 9 storey to 12 storey
All as per item No 80.00 above but 6 to 8mm dia as in stirrups, spacers and binders upto 4 storey high complete all as specified and as directed.
All as per item No 83.00 above but 5 storey to 8 storey
All as per item No 83.00 above but 9 storey to 12 storey
M&L for use and waste of Formwork in flat square, rectangular or plougonal fair finished surfaces to sides of pillars, posts, struts, piers, columns and stanchions upto 4 storey high complete all as specified and as directed.
All as per item No 86.00 above but 5 storey to 8 storey
All as per item No 86.00 above but 9 storey to 12 storey
S&F for mild steel work conforming to Fe 410-W(Gde E-250) quality Joist, channel, angle, or tee sections, fixed independently, without connection plate, etc. upto 4 storey high complete all as specified and as directed.
All as per item No 89.00 above but 5 storey to 8 storey
All as per item No 89.00 above but 9 storey to 12 storey
S&F for Plates (plain or chequered) channels. Square cut or notched (ordinary and counter sunk) forming holes, without any attachment upto 4 storey high complete all as specified and as directed.
All as per item No 92.00 above but 5 storey to 8 storey
All as per item No 92.00 above but 9 storey to 12 storey
Cutting opening in cement concrete walls (any description) with or without reinforcement for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc. upto 4 storey high complete all as specified and as directed.
All as per item No 95.00 above but 5 storey to 8 storey
All as per item No 95.00 above but 9 storey to 12 storey
Cutting opening in cement concrete walls (any description) with cuting reinforcements for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering, etc. upto 4 storey high complete all as specified and as directed.
All as per item No 98.00 above but 5 storey to 8 storey.
All as per item No 98.00 above but 9 storey to 12 storey.
Demolition of brickwork or stone boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars,etc. but excluding ashlar facings, dressed stonework and precast concrete articles upto 4 storey complete all as specified and directed.
All as per item No 101.00 above but 5 storey to 8 storey.
All as per item No 101.00 above but 9 storey to 12 storey.
M&L for brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) upto 4 storey complete all as specified and directed.
All as per item No 104.00 above but 5 storey to 8 storey.
All as per item No 104.00 above but 9 storey to 12 storey.
M&L for brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick walling built in cement mortar 1:4 upto 4 storey complete all as specified and directed.
All as per item No 107.00 above but 5 storey to 8 storey.
All as per item No 107.00 above but 9 storey to 12 storey.
Demolition of PCC flooring not exc 15 cm thickness above ground level upto 4 storey complete all as specified and directed.
All as per item No 110.00 above but 5 storey to 8 storey.
All as per item No 110.00 above but 9 storey to 12 storey.
M&L for 100 mm thick PCC (1:3:6) type C2 (20 mm graded stone agg) as in flooring, finished even and smooth with using extra cement upto 4 storey complete all as specified and directed.
All as per item No 113.00 above but 5 storey to 8 storey.
All as per item No 113.00 above but 9 storey to 12 storey.
Taking down cement plaster on brick or stone wall surfaces including glazed tiles wherever exists including raking out joints, hacking for key and scrubbing down with water upto 4 storey complete all as specified and directed.
All as per item No 116.00 above but 5 storey to 8 storey
All as per item No 116.00 above but 9 storey to 12 storey
M&L for 10mm thick plastering on ceiling surfaces in CM (1:4) & surface finished even and smooth upto 4 storey complete all as specified and directed.
All as per item No 119.00 above but 5 storey to 8 storey
All as per item No 119.00 above but 9 storey to 12 storey
M&L for 15mm thick plastering on fair faces of brick wall and concrete surfaces in CM (1:4) & surface finished even and smooth upto 4 storey complete all as specified and directed.
All as per item No 122.00 above but 5 storey to 8 storey
All as per item No 122.00 above but 9 storey to 12 storey
M&L complete removel of existing tratmenton old decorated plastered or unplastered surfaces of wall, pillasters, cornices etc and applying two coats of acrylic distemper over a coat of primer and wall care putty upto 4 storey complete all as specified and directed.
All as per item No 125.00 above but 5 storey to 8 storey
All as per item No 125.00 above but 9 storey to 12 storey
M&L for one coat of white wash on old decorated surface of internal walls incl preparation upto 4 storey complete all as specified and directed.
All as per item No 128.00 above but 5 storey to 8 storey
All as per item No 128.00 above but 9 storey to 12 storey
M&L for one coat of white wash on old decorated surface of ceiling incl preparation upto 4 storey complete all as specified and directed.
All as per item No 131.00 above but 5 storey to 8 storey.
All as per item No 131.00 above but 9 storey to 12 storey.
M&L for Two coat of white wash on new decorated surface of internal wallsover a coat of Chalk whiting priming including preparation of surfaces upto 4 storey complete all as specified and directed.
All as per item No 134.00 above but 5 storey to 8 storey.
All as per item No 134.00 above but 9 storey to 12 storey.
M&L for Two coat of white wash on new decorated surface of ceiling over a coat of Chalk whiting priming including preparation of surfaces upto 4 storey complete all as specified and directed.
All as per item No 137.00 above but 5 storey to 8 storey.
All as per item No 137.00 above but 9 storey to 12 storey.
Stripping of old tar felt incl layer of plastic or mortar of any type of roof treatment carefully from roof surfaces (without damaging roof) and incl roughening of surface of old concrete roofing by picking, sweeping, cleaning and washing down with water to remove dust complete all as specified and as directed for 5 to 8 storey high bldg.
All as per item No 140.00 above but 9 storey to 12 storey.
M&L for 25mm thick PCC 1:2:4 type 'B-0' using 12.5 mm graded crushed stone aggregate finished with even and smooth without using extra cement for padding concrete with minimum thickness of 25 mm with a slope of 1:40 complete all as specified and as directed for 5 to 8 storey high bldg.
All as per item No 142.00 above but 9 storey to 12 storey.
M&L for 10 mm thick screed bed in cement mortar 1:4 mixed with Water Proofing Compound as per manufacture's instructions and top surface finished even and smooth to recieve water proofing treatment complete all as specified and as directed for 5 to 8 storey high bldg. Note : Water Proofing Compound shall be measured and paid separately.
All as per item No 144.00 above but 9 storey to 12 storey.
M&L cutting out cracks to "V" section in existing roofs of terracing cleaning out, wetting, grouting, with cement sand slurry 1:3 complete all as specified and as directed for 5 to 8 storey high bldg.
All as per item No 146.00 above but 9 storey to 12 storey.
M&L for providing PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in filling in depression on roof slab complete all as specified and as directed for 5 to 8 storey high bldg.
All as per item No 148.00 above but 9 storey to 12 storey.
M&L for covering/filleting of sectional area exc. 25 sqcm but not exc. 50 sqcm in any position and to any shape in PCC 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) incl all mitres, stops etc complete all as specified and as directed for 5 to 8 storey high bldg.
All as per item No 150.00 above but 9 storey to 12 storey.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid over and including primed surface by forced application complete all as specified and directed upto 12 storey high of bldg.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) area exc 1.5 sqm but not exc 4 sqm each complete all as specified and directed for 5 to 8 storey high bldg.
All as per item No 153.00 above but 9 storey to 12 storey.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type complete all as specified and directed for 5 to 8 storey high bldg.
All as per item No 155.00 above but 9 storey to 12 storey.
S&F Steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete Gauzed with glazing bars, dovetailed or welded complete including taking down old steel window all as specified and directed for 5 to 8 storey high bldg.
All as per item No 157.00 above but 9 storey to 12 storey.
S&F in repair framed work such as grills, gratings, etc. with ends of bars shouldered and /or riveted or forged into spikes, framed guard bars barred iron doors; ladders framed alusters; wald ways; railings; framework of water tanks and similar work confrming to Fe-290 Gde -E 165 complete all as specified and directed for 5 to 8 storey high bldg.
All as per item No 159.00 above but 9 storey to 12 storey.
S&F 100 mm long butt hinge, stainless steel complete all as specifiedd and directed for 5 to 8 storey high bldg.
All as per item No 161.00 above but 9 storey to 12 storey.
S&F aluminium anodised handles cast type, anodised 150mm long complete all as spd and directed for 5 to 8 storey high bldg.
All as per item No 163.00 above but 9 storey to 12 storey.
S&F aluminium anodised tower bolt cast type, anodised 200 mm long complete all as spd and directed for 5 to 8 storey high bldg.
All as per item No 165.00 above but 9 storey to 12 storey.
S&F 300mm long sliding door bolts with hasp stapple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bots and sliding bolts of extruded or cast aluminium alloy for 5 to 8 storey high bldg.
All as per item No 167.00 above but 9 storey to 12 storey.
S&F second class hard wood (sal) plain, solid, straight chowkhats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed for 5 to 8 storey high bldg.
All as per item No 169.00 but 9 storey to 12 storey.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel/aluminium frames glazed with putty or fixed with beads complete for 5 to 8 storey high bldg.
All as per item No 171.00 above but 9 storey to 12 storey.
S&F 4.8 mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area of glass not exc 0.5 sqm each pane for 5 to 8 storey high bldg all as specified and directed.
All as per item No 173.00 above but 9 storey to 12 storey.
S&F in repair 0.56 mm thick plain aluminium sheeting,alloy 31000 H4 in stepped flashing (measured as the minimum rectangle from which the pieces can be cut) complete all as specified and dirrected for 5 to 8 storey high bldg.
All as per item No 175.00 above but 9 storey to 12 storey.
S&F in repair stainless steel wire cloth, 0.63 mm dia of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanized wire staples complete all as specified and directed for 5 to 8 storey high bldg.
All as per item No 177.00 above but 9 storey to 12 storey.
Taking down eaves gutters and rain water pipes, cast iron pipes(any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) upto 4 storey complete all as specified and as directed.
All as per item No 179.00 above but 5 storey to 8 storey.
All as per item No 179.00 above but 9 storey to 12 storey.
S&F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints and laid in trenches or in floor of following size upto 4 storey upto 4 storey complete all as specified and as directed.
All as per item No 182.00 above but 5 storey to 8 storey.
All as per item No 182.00 above but 9 storey to 12 storey.
S&F PVC (SWR)110 mm bore pipes single socketed in any length with rubber ring joints and fixed to wall of following size upto 4 storey complete all as specified and as directed.
All as per item No 185.00 above but 5 storey to 8 storey.
All as per item No 185.00 above but 9 storey to 12 storey.
S&F 110 mm bore PVC (SWR) bends any radius including necessary cutting in brick wall and making good to match with existing surface of following size upto 4 storey complete all as specified and as directed.
All as per item No 188.00 above but 5 storey to 8 storey.
All as per item No 188.00 above but 9 storey to 12 storey.
S&F 110 mm bore PVC (SWR) junction single, (single T) equal or unequal of following size upto 4 storey complete all as specified and as directed.
All as per item No 191.00 above but 5 storey to 8 storey.
All as per item No 191.00 above but 9 storey to 12 storey.
S&F in repair 50 mm bore (Outer dia) UPVC pipes of SCH-40 and plain UPVC SDR 11 fitting fixed on wall or floor, ceiling or laying in floors upto 4 storey complete all as specified and as directed.
All as per item No 194.00 above but 5 storey to 8 storey.
All as per item No 194.00 above but 9 storey to 12 storey.
Demolation of cement concrete (reinforced) in pre cast slab not exceeding 15 cm thick complete all as specified and directed.
M&L for RCC (1:2:4) (Nominal Mix), Type-B1 (using 20mm graded stone aggregates) as in pre cast slabs supported on walls complete all as specified and directed.
Dismantling of existing Expansion joint system and M & L applying TPO/FPO based joints sealing membrane, Sikadur Combiflex SG (150x2mm) with epoxy adhesive, Sikadur 31 C ( the joint shall be packed withing polystyrene board before application of Combiflex ). Then providing Sika pllystrene sealant into the gap after proper surface prepration after filling the gap with polyurethene backer rod, followed by precast RCC slab (1:2:4 ) 50 mm thick placed over the joint with minimum 150 mm projection on either side with proper drip course of size (length) n.exc. 1.2 mtr each and sealing the joints of precast RCC slab with exterior grade silicone sealant of size i.e. 10 mmx 10 mm balance with polystrene board complete all as specified and as directed by the Engr -in-Charge.
Supply only Integral water proofing compound (ISI Mark) complete all as specified and as directed.
M&L for preparation of new steel or iron surfaces of any description area exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and zinc chrome primer complete all as specified and dirrected for 5 to 8 storey high bldg.
All as per item No 201.00 above but 9 storey to 12 storey.
M&L for preparation of new wooden surfaces of any description area exc 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and dirrected for 5 to 8 storey high bldg.
All as per item No 203.00 above but 9 storey to 12 storey.
Dismanteling and taking down carefully all electrical and mechanical components, assemblies, sub-systems such as drives, machine, controls panels, lift car, ropes, guides, counter weights, rails, beams and doors, electrical wirings, control wirings etc complete of exising beyond economical repairs (BER) lifts including taking down all steel work and components from machine room, lift shaft , lift pit and stacking neatly all retrieved components for perusal of BOO and making good the disturebed surface in Machine room at all landing and in lift door facias, to match with the existing surfaces complete all as directed at site by Engineer-in Charge for following lifts :- NOTE : Making good to disturbed surfaces will be paid under relevent items listed in B&R works here-in-above.
Dismantling of the old 08 passengers lift machine (G + 7) and all connected accessories all as per specified and directed.
Dismantling of the old 13 passengers lift machine (G + 7) and all connected accessories all as per specified and directed.
Dismantling of the old 08 passengers lift machine (G + 10) and all connected accessories all as per specified and directed.
Dismantling of the old 08 passengers lift machine (G + 6) and all connected accessories all as per specified and directed.
Dismantling of the old 13 passengers lift machine (G + 6) and all connected accessories all as per specified and directed.
Dismantling of the old 13 passengers lift machine (G + 5) and all connected accessories all as per specified and directed.
Dismantling of the old 8 passengers lift machine (G + 8) and all connected accessories all as per specified and directed.
Dismantling of the old 13 passengers lift machine (G +8) and all connected accessories all as per specified and directed.
Dismantling of the old 13 passengers lift machine (G +9) and all connected accessories all as per specified and directed.
Dismantling of the old 8 passengers lift machine (G + 11) and all connected accessories all as per specified and directed.
Dismantling of the old Goods lift machine (G + 10) and all connected accessories all as per specified and directed.
Dismantling of the old 13 passengers lift machine (G +10) and all connected accessories all as per specified and directed.
Dismantling of the old 13 passengers lift machine (G +11) and all connected accessories all as per specified and directed.
Dismantling of the old 13 passengers lift machine (G +12) and all connected accessories all as per specified and directed.
NOTES FOR ITEM NO. 205.01 to 205.14 (i) In case any of the lift as above is working on Duplex/Triplex full collective control operation mode with other lifts in the same Block/Buiding, as a first step before dismanteling the control modalalities af all lifts shall be suitably modified, so that the operation of other existing lifts is not effected.
Garrison Engineer Alipur Kolkata Area Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+7 upper floors with AC Variable Frequency Regenerative (Cosed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below complete all as specified and directed:- Location of lift : P-118 II Lines-02 Nos, P-119 II lines-1 No.
(a) Type & capacity : 8 Passenger, 544Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control. (e) Location of Machine Room : Top of Building (As existing). (f) Machine : Gearless Machine. (g) Travel : As per existing site to serve G+7 floor. (h) Serving : G+ 7 upper floors- (8 Stops, 8 landings, 8 openings) (j) Existing Well size : As existing at site. (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code. (r) Flooring : Aluminum chequred plate with Vinyle flooring. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6,7 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator (ag) Micro- Stroke push buttons shall be provided. (ah) All landing door shall be one hour fire rated.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply, install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+7 upper floors with AC Variable frequency Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given below complete all as specified and directed :- Location of lift : Lift No-1 CH(EC), Sky View.
(a) Type & capacity : 13 Passenger, 884 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (As existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+7 floor (h) Serving : G+ 7 upper floors- (8 Stops, 8 landings, 8 openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code. (r) Flooring : Aluminum chequred plate with Vinyle flooring. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6,7 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided. (ah) All landing door shall be one hour fire rated.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+6 upper floors with AC Variable frequency Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below, complete all as specified and directed :- Location of lift : P-161 II line, Gokhale road.
(a) Type & capacity : 8 Passenger, 544 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+6 floor (h) Serving : G+ 6 upper floors- (7 Stops, 7 landings, 7 openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code. (r) Flooring : Aluminum chequred plate with Vinyle flooring. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs
(y) Roping : Lift rope/Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided. (ah) All landing door shall be one hour fire rated.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Suitable hand rail as per recommendation of manufacturer/ relevant IS shall be provided for use of lift by handicapped as directed. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel # 4 (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+8 upper floors with AC Variable frequency Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below complete all as specified and directed :- Location of lift : lift No-5 CH(EH), Gokhale road.
(a) Type & capacity : 8 Passenger, 544 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : F Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+8 floor (h) Serving : G+ 8 upper floors- (9 Stops, 9 landings, 9 openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code. (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6,7,8 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided. (ah) All landing door shall be one hour fire rated.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Suitable hand rail as per recommendation of manufacturer/ relevant IS shall be provided for use of lift by handicapped as directed. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel # 4 (Hairline). (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with AC Variable frequency Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator, announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door), Battery operated emergency light & alarm complete all as specified for 8 passenger as per the details given below complete all as specified and directed :- Location of lift : P-127 II Lines, P-128 II lines, P-129 II lines , Grand View-1 -02 Nos.
(a) Type & capacity : 8 Passenger, 544 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : F Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+10 floor (h) Serving : G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code. (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6,7,8 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided. (ah) All landing door shall be one hour fire rated.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Suitable hand rail as per recommendation of manufacturer/ relevant IS shall be provided for use of lift by handicapped as directed. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install, testing & commissioning of Passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+10 upper floors with AC Variable frequency Regenerative (Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3D infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door),Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given below complete all as specified and directed :- Location of lift : P-151 II lines.
(a) Type & capacity : 13 Passenger, 884 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : F Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+10 floor (h) Serving : G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code. (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6,7,8,9,10 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided. (ah) All landing door shall be one hour fire rated.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Suitable hand rail as per recommendation of manufacturer/ relevant IS shall be provided for use of lift by handicapped as directed. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install testing & commissioning of passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+12 upper floors with AC Variable frequency Regenerative(Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3d infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door), Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given below., complete all as specified and directed. Location of Lift : Turf view p-19/1,Turf view P-19/2.
(a) Type & capacity : 13 Passenger, 844 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+12 floor (h) Serving : G+ 12 upper floors- (13 Stops, 13 landings, 13 Openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured Vinyle designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6,7,8,9,10,11,12 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design, supply, install, testing & commissioning GOODS lift 2000 kg , speed 1.0 metre/sec with single speed motor, 415 volts, 3 phase AC 50 Hz supply, conforming to IS-14665 and as amended, suitable to serve G+10 upper floors with AC Variable Voltage & Variable Frequency Drive (VVVF drive) Or Variable Frequency Regenerative Drive complete with all standard accessories, simplex utomatic & manual dual controlled operation without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, Machine room & near Ground floor landing door) Battery operated emergency light & alarm complete all as specified for 2000 Kg weight as per the details given below and including dismantling of existing BER electric driven goods lift with machine, lift car, rope, guides, counter weight , rail, beam & door etc., complete all as specified and directed :- Location of lift : P-152 II Lines, P-153 II lines.
(a) Type & capacity : 2000 Kgs - Gearless (b) Speed : 1.0 M/Sec (c) Type of Drive : VVVF Or VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+10 floor (h) Serving : G+ 10 upper floors- (11 Stops, 11 landings, 11 openings) (j) Existing Well size : As per site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, anti skid coloured designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code. (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6,7,8,9,10 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided. (ah) All landing door shall be one hour fire rated.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Suitable hand rail as per recommendation of manufacturer/ relevant IS shall be provided for use of lift by handicapped as directed. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Garrison Engineer (Central) Area Design supply , install testing & commissioning of passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+6 upper floors with AC Variable frequency Regenerative(Closed loop) drive (ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3d infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door), Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given below., complete all as specified and directed Location of lift : P-127 BMC Offrs Married Accn.
(a) Type & capacity : 13 Passenger, 844 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+6 floor (h) Serving : G+ 6 upper floors- (7 Stops, 7 landings, 7 Openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured Vinyle designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install testing & commissioning of passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+8 upper floors with AC Variable frequency Regenerative(Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3d infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door), Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given below., complete all as specified and directed . Location of lift : BMC OR Married Accn NP-1/1.
(a) Type & capacity : 13 Passenger, 844 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+8 floor (h) Serving : G+ 8 upper floors- (9 Stops, 9 landings, 9 Openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured Vinyle designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,7,8 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install testing & commissioning of passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+5 upper floors with AC Variable frequency Regenerative(Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3d infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door), Battery operated emergency light & alarm complete all as specified for 13 passenger as per the details given below., complete all as specified and directed Location of lift : BMC HQ CEKZ P-62/1
(a) Type & capacity : 13 Passenger, 844 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+5 floor (h) Serving : G+ 5 upper floors- (6 Stops, 6 landings, 6 Openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured Vinyle designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install testing & commissioning of passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+9 upper floors with AC Variable frequency Regenerative(Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3d infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door), Battery operated emergency light & alarm for 13 passenger as per the details given below, complete all as specified and directed. Location of Lift : BMC JCO Md accn NP-4/1.
(a) Type & capacity : 13 Passenger, 844 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+9 floor (h) Serving : G+ 9 upper floors- (10 Stops, 10 landings, 10 Openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured Vinyle designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6,7,8,9 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply, install testing & commissioning of passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+11 upper floors with AC Variable frequency Regenerative(Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3d infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door), Battery operated emergency light & alarm for 08 passenger as per the details given below complete all as specified and directed. Location of Lift : BMC SF Md Accn P-138/P-160.
(a) Type & capacity : 08 Passenger, 544 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+11 floor (h) Serving : G+ 11 upper floors- (12 Stops, 12 landings, 12 Openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : 1600 mm . (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured Vinyle designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6,7,8,9,10,11 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install testing & commissioning of passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+11 upper floors with AC Variable frequency Regenerative(Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3d infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door), Battery operated emergency light & alarm for 13 passenger as per the details given below complete all as specified and directed. Location of lift : BMC OR Md accn-NP-3/1.
(a) Type & capacity : 13 Passenger, 844 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+11 floor (h) Serving : G+ 11 upper floors- (12 Stops, 12 landings, 12 Openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured Vinyle designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : 0,1,2,3,4,5,6,7,8,9,10,11 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Design supply , install testing & commissioning of passengers lift electrically operated, microprocessor controlled, speed 1.5 meter/sec, lift with single speed motor 415 volts, 3 phase, AC 50Hz supply conforming to IS-14665, suitable to serve G+12 upper floors with AC Variable frequency Regenerative(Closed loop) drive ( ACD3-MR drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendent, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, emergency automatic rescue device (ARD) system with standby power supply by using suitable capacity maintenance free battery, 3d infra red sensor in full height of door & built in voice announcement system in the car to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator,announcing system without hand set ( 03 Nos, one each in car, Machine room & near ground floor landing door), Battery operated emergency light & alarm for 13 passengers as per the details given below complete all as specified and directed Location of Lift : P-161 BMC offrs Marrid Accn, HV/2 Hasting Offrs Married Accn.
(a) Type & capacity : 13 Passenger, 844 Kgs - Gearless (b) Speed : 1.5 M/Sec (c) Type of Drive : VF Regenerative (Closed Loop) (d) Type of control : Microprocessor based Simplex full Collective control (e) Location of Machine Room : Top of Building (as existing) (f) Machine : Gearless Machine (g) Travel : As per existing site to serve G+12 floor (h) Serving : G+ 12 upper floors- (13 Stops, 13 landings, 13 Openings) (j) Existing Well size : As existing at site (k) Existing Pit depth : (Existing Pit Depth is meeting the requirements of NBC , IS Codes and West Bengal Lift Rules. However if any modification is still required as per manufacturers recommendation the same shall be carriried out by Contractor without any extra cost to the Department) . Pit depth and overhead shall be such as to conform to the requirements of bottom clearance and top clearance as specified in IS: 14665. (l) Head Room : As per existing site. (m) Power supply : 415 volts Three-Phase, 50 Cycles AC. The entire lift equipment shall be suitable for operation at +10% to - 20% of rated supply voltage.
(n) Auxiliary supply : 220 volts Single-Phase, 50 Cycles AC. (o) Earth connection : All new Earthing Points and Earth Contunity strips, connections Conductors shall be provided as per NBC, National Electrical Code and Code of Practices for Earhing. The quoted rates shall be deemed to be inclusive of all earthing provisions. (p) Car Enclosure : Stainless Steel, mirror finish body of car incl recessed LED light, Blower type fan of suitable size, false ceiling, anti skid coloured Vinyle designer flooring as per NBC or other relevant BIS code. (q) Car Size : As per NBC 2016 or other relevant BIS code (r) Flooring : As per NBC 2016 or other relevant BIS code. (s) No of Entrance : One location - Front. (t) Car Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (u) Landing Entrance : Automatic power operated centre opening, Stainless Steel, mirror finish Door. (v) Clear opening for door : As per existing site. (w) Floor Designation : G,1,2,3,4,5,6,7,8,9,10,11,12 (x) Indicators : Car & Landings : Direction & Position Indicator/ call registration LEDs.
(y) Roping : Lift rope/ Lift belt shall be provided as per NBC-2016 and IS 14665 - 2001 (upto date) of tensile strength not less than 12.5 tonnes/cm square and factor of safety shall be 8.6 (z) Battery operated emergency Alarm & Light shall be provided. (aa) Full height Infra-red Light Curtain Door Safety shall be provided. (ab) Press & Speak Phone shall be provided for intercom system. (ac) Fireman switch shall be provided. (ad) Emergency Automatic Rescue Device (ARD) with suitable capacity maintenance free battery shall be provided for elevation of passengers trapped in lift car during power failure between floors .The ARD shall work for 3 phase and single phase failure. (ae) Overload Protection Device, Load Weighing Device(LWD)/OSG (overspeed governors) Electronic switch shall be provided. (af) Voice announcement system in the car shall be provided to announce the position of the elevator in the hoistway as the car passes or, stops at a floor served by the elevator. (ag) Micro- Stroke push buttons shall be provided.
(aj) Car door lock shall be provided. (ak) Auto drive recall, Automatic Fan & light switching off arrangements shall be provided. (al) Hand Rails : Stainless steel mirror finish handrails on rear sides in car panels. Full height and full width mirror to be provided on rear side above hand rails. (am) MS Pit Ladder shall be provided. (an) Door Operator : DC Door Operator (ao) Car operating panel : Square flush painted buttons in stainless steel. (ap) Car position indicator : Dot matrix (Red LED) scrolling display. (aq) Hall fixtures : 16 segment display hall button. (ar) Hall fixtures face plate : Stainless steel. (as) Hall button arrangement : Hall button with FPI. (at) Standard Features : Anti nuisance car cell protection, overload device, nudging, independent service belt inspection device. Emergency Fireman's service. Emergency car light unit, Infrared curtain protection, door time protection, emergency alarm button, extra door time of lobby and parking, door open/close button, manual rescue operation, belt inspection drive and auto fan cut off. (au) Machine room ladder, where applicable shall be provided by the contractor. (av) Host way wiring, where required shall be provided by the contractor.
Note for Item No 202.00 to 216.00.05 (i) The system (Lift) shall be guaranteed against maintenance and repair including spares for a period of Two years from the certified date of completion of this contract and the cost of these shall be deemed to be included in the unit rates quoted against the lifts . The lump sum cost of above lift shall be deemed to include cost of comprehensive maintenance in defect liability period of all the lifts provided by the contractor under this contract for a period of one year from the certified date of completion of the work. For this a sum of Rs. 4,00,000.00 (Rupees Four Lakhs only) shall be retained from the final bill of this contract till satisfactory completion of said comprehensive maintenance period of lifts as certified by the GE. The amount so retained shall be released by the GE after expiry of satisfactory comprehensive maintenance in defect liability period. (ii) The bidder/ tenderer is be advised to visit existing lifts, lifts well, machine room at site, before quoting his offer and nothing will be paid on this account. Irrespective of the fact if the Bidder has visited the site or not, it shall be assumed that he has visted the site and nothing extra shall be payable on account of any variation in site conditions than those specified in tender.
(iii) The quoted rate shall deemed to include the cost of minor civil works, MS Beam, MS rail with fixing arrangement including making good to the disturbed surface to match with the existing. (iv) The lifts shall comprise of all latest fail safe measures as specified in relevant IS Codes (IS-14665 of 2015: Part-I, IS-14665 of 2009: Part -V, IS-4591 of 2012, IS-15785 of 2007) and National Building Code – 2016 Section-5 part-8 as revised from time to time. (v) The wiring of lift shall be with copper conductor, stranded, ISI marked of suitable size. The wiring in the lift well shall be in MS conduit, ISI marked medium grade of suitable size. Suitable sockets/lights shall be provided as directed in the lift shaft. (vi) If anything missed above but is technically required for efficient working of the lift is deemed to be included in the quoted rate. (vii) Instruction shall be provided by the manufacturer inside and outside the car. The instructions shall be written on a metallic sheet with embossed letters matching with car decor/outside decor all as directed. (viii) A board depicting manual rescue procedure to be provided at location as directed. (ix) The comprehensive maintenance of lift shall be executed through OEMs or their accredited/ authorized agencies.
(x) The contractor shall submit MOU with the OEMs or their accredited/ authorized agencies for comprehensive maintenance of defect liability period after one month of date of commencement. (xi) The quoted rate is deemed to include the above provisions as specified above. (xii) After errection of lift it must be tested from State Govt lincense Inspector or their authorised vendors. (xiii) In case of any specific capacity of passenger are not manufactured by the any above OEM, the contractor shall provide nearby higher capacity of passenger by OEM without any extra cost to the department. (xiv) GA drawings shall be submitted by the contractor prior to execution of work for approval of GE.
Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised strip of size 25 x 4mm by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.
Supply and fixing in repair for earth continuity conductor or main earthing lead fixed to wall on porcelain insulator or recess or chases or buried in ground or drawn in conduit/ pipe or fixed to poles or any other indicated situation for wall/ roof etc. as required by 32x6mm galvanised iron strip complete all as specified and directed.
M/S N.K BUILDERS
DNS CONSTRUCTION COMPANY
M P KHAITAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .