Loading…
Loading…
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
31 Aug 2026, 3:00 pm3d left
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
TENDER ELG
15 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.(In this connection scanned copy of Annexure VIB duly filled up must be attached with offer).
The tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works costing not less than the amount equal to 40% of advertised value of the tender, or One similar work costing not less than the amount equal to 60% of advertised value of the tender .Other terms and conditions shall follow of GCC, April 2022. Definition of Similar nature of work has given below (1.1)
Defination of Similar Work :- As per CEE's letter No. EL/112/0, dated 16.09.2025 Item Sl. No. 8 ( i ) under "Lifts and Escalators "Supply, Installation , Testing and Commissioning of Lift/Escalator with or without AMC/CAMC AND Item Sl. No.2.(ii) under "LT Electrical Works" Execution of any HT or LT Electrical work.
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
16 conditions · 6 needing a document upload
The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Scanned copy of valid GST (Goods & Service Tax)Registration Certificate.
The following documents should be attached with the tender ( Annexure-V (A) certificate is to be given by attorney/authorized signatory/each member of Partnership firm/Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. & Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder
Partnership deeds, power of Attorney etc. (if any) : The tender shall clearly specify whether the tender is submitted on his own or on behalf of a partnership concern. If the tender is submitted on behalf of partnership concern he should submit the certified copy of the partnership deed along with the tender authorisation to sign the documents on behalf of the partnership firm. If these documents are not enclosed along with the tender document, the tender will be treated as hearing lease submitted by the individual signing the tender documents. The Railway will not consider any power of Attorney granted by the tender or any changes in the composition of the firm made subsequent to the execution of the contract. It may however recognize such power of Attorney and change after obtaining proper legal advice, the cost of which will be chargeable to the contract.(Scanned copy POA/Partnership deed is to be uploaded Duly filled up by the bidder. As per clause no. 14(e) of GCC'22, the following documents to be uploaded in terms of Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company. (iv) All other documents in terms Para 10 of the Tender Form (Second Sheet) above.
Option for receiving payment through Letter of Credit . (Please attach scannedcopy of ANNEXURE 1 LC & ANNEXURE 2 LC duly filled up by the firm if optedfor)
The following documents should be attached with the tender: (i)Scanned copy of Pan Card. (ii)Scanned Copy of EFTMANDATE FORM Duly filled up by the bidder(iii)Tender Document (duly digitally signed by the bidder)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Scanned copy of valid Trade license or Propitorship Certificate.
Railway Officers Associated with tenderer:RAILWAY OFFICERS ASSOCIATED WITH TENDERER 1. ExRailway Officer as tenderer: Should tenderer be a retired Gazetted Officer working before his retirement on any of the Railways owned and administered by the President of India, or should the tenderer being partnership firm have as one of its partners a retired Gazetted Officer as aforesaid, or should the tenderer being an incorporated company have any such retired Officer as one of its Directors, or should the tenderer have in his employment any retired Gazetted Officer as aforesaid, full information of such person shall be submitted along with his tender in the format given in annexure-VI to this chapter of this tender document. (Authority: ACS No.3 to GCC July,2014vide Boards letter No.2014/CEI/CT/O/9/RET dt.22.01.2015)(please attach scanned copy of Annexure-VI duly filled up by the firm).
List of the Works completed in the last three financial years giving description of work. Organization for whom executed, approximate value of contract at the time of award, date of award and date of scheduled completion of work. Date of actual start, actual completion and date of payment and final value of contract should also be given. (Supportive documents/ certificates from the organization with whom worked/are working should be enclosed) (Please attach scanned copy of Annexure-I duly filled up).
List of works in hand indicating Supportive documents/certificates from the organization with whom worked/are working should be enclosed) description of work, contract value, approximate value of balance work yet to be done and date of award. (Supportive documents/certificates form the organization with whom worked/are working should be enclosed).(Please attach scanned copy of Annexure-IV duly filled up)
Submission of Documents in support of Eligibility Criteria : All documents in support of fulfillment of eligibility criteria with respect to completion of 'Similar Nature of work for technical Eligibility criteria 'and 'Total Contract value for Financial Eligibility Criteria' should be uploaded online in the website with scanned copy at the time of tender bidding with the details. No post - tender communication , in any form will be made or entertained , after opening of tenders in this regard .Railways may however call for the originals of the credentials for verification or any clarifications/Confirmations on the contents of the documents submitted .Eligibility of tenderers shall be decided solely on the basis of the documents submitted alongwith the tender offers and any subsequent document whatsoever submitted in this connection would not be given any cognizance on any account.
The Contractor/(firm) must go through the entire tender document along with all attachment for any kind of guidance regarding execution of the job & payment there after. In case any thing is left out or not clear then they should consult the General Condition of Contract & standard Specification as attached (uploaded ).The bidders are also advised to preserve a copy of entire tender document/ (Set) for their convenience.
Electrical (General) work in connection with Construction of Type-V qtrs, 12 units at Rail Sadan, Howrah.
EL-HWH-25-21-3661~ER
EL-HWH-25-21-3661
Open
Works - General
180 Days
Howrah, West Bengal
₹0
₹2.2 L
10 Aug 2026
10 Aug 2026
17 Aug 2026
139 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 1,09,16,293 | ||
| — | — | — | Above/ 122640.00 Below/P | ||
| Wiring of Light / Fan / Call Bell / Glow Sign point by 2 nos.single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phaseand neutral in PVC conduit / casing along with 1 no. singlecore HRFR / FRLS grade, PVC insulated, copper conductorcable of size 1.5 sq.mm, 1100V grade for Earth ContinuityConductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 420.00 | — | — | |
| — | — | — | Above/ 37164.00 Below/P | ||
| Wiring of 6A / 3 pin Plug board consisting with one plug socketand one 6A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 1.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 228.00 | — | — | |
| — | — | — | Above/ 92400.00 Below/P | ||
| Wiring of 6/16A 3 pin Plug board consisting with one 16/6A 3 pin plug socket and one 16A switch by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 2.5 sq.mm, 1100V grade for phase and neutral in PVC conduit / casingalong with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 1.5 sq.mm, 1100V grade forEarth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 240.00 | — | — | |
| — | — | — | Above/ 68940.00 Below/P | ||
| Wiring of AC Machine ( Window / Split ) / Water Cooler point by2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core, HRFR / FRLS grade, PVC insulated, copper conductor cable ofsize 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC ) and each switch board comprising with one power unit which includes one double pole MCB, one single phase starter and one 6/16A 3 pin socket and plug with indicating light andall other associated work( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 60.00 | — | — | |
| — | — | — | Above/ 163200.00 Below/P | ||
| Wiring of Submain by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated,copper conductor cable of size 2.5 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 2400.00 | — | — | |
| — | — | — | Above/ 148800.00 Below/P | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 6.0 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1200.00 | — | — | |
| — | — | — | Above/ 278400.00 Below/P | ||
| Wiring of Mainline by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 10 sq.mm, 1100V grade for phase and neutral in PVC conduit / casing along with 1 no. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 4.0 sq.mm, 1100V grade for Earth Continuity Conductor ( ECC )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1200.00 | — | — | |
| — | — | — | Above/ 54168.00 Below/P | ||
| Extra cost for conceal wiring in respect to PVC conduit / casingfor light, fan, plug, power plug, multi-plug point etc. includingmake good of wall surface as its original condition | — | 888.00 | — | — | |
| — | — | — | Above/ 91200.00 Below/P | ||
| Extra cost for conceal wiring for main / submain with respect to PVC conduit / casing including make good of wall surface as its original condition | — | 4800.00 | — | — | |
| — | — | — | Above/ 135240.00 Below/P | ||
| Extra cost involvement for modular switch, bell push, plug socket,fan regulator, USB point, TV socket etc. with other accessories( Make of Modular switch, socket, box, cover plate etc. - ABB /Anchor ( Panasonic ) / Havells ( Crabtree ) / Legrand / LK (L&T) ) | — | 1380.00 | — | — | |
| — | — | — | Above/ 17808.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of 20-22W LED batten (Type of LED - Surface Mounting Device ) tube with industrial grade constant current Driver ( Efficiency - Greater than 85% ) with short circuit protection, extruded aluminium housing and milky polycarbonate diffuser ( LEDchip make - Nichia, Osram, Seoul, Philips, Lumileds, Everlight, Avago,Cree, Lednium, APT Electronics & BridgeLux ), LED luminaire system efficacy - Greater than 120 Lumens per Watt @ 350mA drive current,Colour Temperature - 6500K (Cool white), CRI>80, SDCM<5, Driver Operating Voltage - 140-270 Volt AC, Surge Protection minimum 4KV, THD<10%, Driver HV Cut off @ 325V/440V (P2P) protection for8 hrs., Life span of LED chip Greater than 50000 burning hours, The Luminaire & Driver both should be of same make / brand and indivi- dually BIS approved with 60 months warranty including fixing withGI clamps made of GI flat of suitable size & GI nut-bolts.( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 84.00 | — | — | |
| — | — | — | Above/ 292800.00 Below/P | ||
| Supply of Bracket Light complete with all accessories. | — | 120.00 | — | — | |
| — | — | — | Above/ 30000.00 Below/P | ||
| Fixing, connection and commissioning of Bracket lightfittings with suitable arrangement. | — | 120.00 | — | — | |
| — | — | — | Above/ 50040.00 Below/P | ||
| Supply of diffuse Mirror Light of size 1 feet complete with all accessories. | — | 36.00 | — | — | |
| — | — | — | Above/ 9000.00 Below/P | ||
| Fixing, connection and commissioning of Mirror lightfittings of 1 feet with suitable arrangement. | — | 36.00 | — | — | |
| — | — | — | Above/ 68000.00 Below/P | ||
| Supply of Profile Light complete with all accessories. | — | 80.00 | — | — | |
| — | — | — | Above/ 8000.00 Below/P | ||
| Fixing, connection and commissioning of Profile lightwith suitable arrangement. | — | 80.00 | — | — | |
| — | — | — | Above/ 6696.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of Self Ballasted 12W LED Lamps suitable for operation in 230V, 50 Hz, 1Ph supply with minimum 36 months warranty with suitable arrangement. | — | 36.00 | — | — | |
| — | — | — | Above/ 42210.00 Below/P | ||
| Supply of LED 3W step / foot light integrated with high efficient LEDs with die-cast aluminium housing and clear glass (Colour temperature 3000K/4000K/6000K) complete with all accessories, operating Voltage and frequency 230V AC, 50Hz ( similar to Legero Model No.- EDGE LSA 3003 or equivalent ). | — | 90.00 | — | — | |
| — | — | — | Above/ 6660.00 Below/P | ||
| Fixing, connection, testing and commissioning of indoor LEDluminaire fittings with suitable arrangement. | — | 90.00 | — | — | |
| — | — | — | Above/ 20840.00 Below/P | ||
| Supply, installation, connection and commissioning of Floodlight 80 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast aluminium housing with Ingress Protection - IP66 or higher ( LED chip make - Nichia, Osram,Seoul, Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics & BridgeLux ), complete with all accessories, LEDluminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current, Impact resistance IK-05 or higher, Colour Temperature - 3000K-5700K, Driver Surge Protection minimum 4KV,Life span of LED chip Greater than 50000 burning hours, The Luminaire& Driver both should be of same make / brand and individually BIS approved with 60 months warranty including fixing with suitable diaheavy gauge GI bend pipe with GI clamps made of GI flat of size 40mm x 6mm and GI nut-bolts on structure / wall.( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 20.00 | — | — | |
| — | — | — | Above/ 11550.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of Street light 90 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast housing with IngressProtection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul,Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics& BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current,Impact resistance IK-05 or higher, Colour Temperature - 3000K/5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greaterthan 50000 burning hours, The Luminaire & Driver both should be ofsame make / brand and individually BIS approved with 60 months warranty including fixing with suitable dia heavy gauge GI bend pipewith GI clamps made of GI flat of size 40mm x 6mm and GI nut-boltson structure / wall.( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 10.00 | — | — | |
| — | — | — | Above/ 22000.00 Below/P | ||
| Designing of mounting layout, supply, installation, connection and commissioning of Street light 90 Watt LED (Type of LED - Surface Mounting Device ) luminaire, pressure die cast housing with IngressProtection - IP66 or higher ( LED chip make - Nichia, Osram, Seoul,Philips, Lumileds, Everlight, Avago, Cree, Lednium, APT Electronics& BridgeLux ), complete with all accessories, LED luminaire system Efficacy minimum - 130 Lumens per Watt @ 350mA drive current,Impact resistance IK-05 or higher, Colour Temperature - 5700K, Driver Surge Protection minimum 4KV, Life span of LED chip Greaterthan 50000 burning hours, The Luminaire & Driver both should be ofsame make / brand and individually BIS approved with 60 months warranty including fixing, connection and commissioning of outdoor Flood light / Street light fitting on High Mast Tower / Pole / Structurewith suitable arrangement.( Make : Philips (Signify) / Havells / Bajaj / Panasonic / Crompton / Jaquar / Lighting Technologies / Halonix ) | — | 20.00 | — | — | |
| — | — | — | Above/ 85080.00 Below/P | ||
| Supply of Bollard light fitting complete with all accessories ( similar to Make - Crompton, Cat. No- LBSR-10-CDL ) or equivalent. | — | 20.00 | — | — | |
| — | — | — | Above/ 18500.00 Below/P | ||
| Installation, connection and commissioning of above bollard fittings with foundation and supply of 4 way terminal box alongwith 1 no. fuse unit. | — | 20.00 | — | — | |
| — | — | — | Above/ 85108.00 Below/P | ||
| Supply of Outdoor Post Top 40W LED luminaire (IP65) complete with 40Watt LED (Type of LED - Surface Mounting Device) with industrial grade constant current driver (Efficiency - Greater than 85%) with short circuit protection, (LED make - Nichia, Osram, Seoul, Philips, Lumileds, Everlight, Avago, Cree & Lednium), LED efficacy - Greater than 100 Lumens/ Watt@ 350mA drive current, Life span of LED chip - Greater than 50000 burning hours including all other accessories. | — | 4.00 | — | — | |
| — | — | — | Above/ 780.00 Below/P | ||
| Fixing, connection and commissioning of out door Post Top LED light etc. fitting on tower/ pole/ wall/ structure/ on cement foundation etc. with suitable arrangement | — | 4.00 | — | — | |
| — | — | — | Above/ 4000.00 Below/P | ||
| Supply of Decorative Globe Light fittings with 9W LED Lamp complete with all other accessories. | — | 4.00 | — | — | |
| — | — | — | Above/ 1600.00 Below/P | ||
| Fixing, connection and commissioning of above decorative Globe light fittings with GI Pipe of 40mm dia, 8" long and suitable size Fastner Bolt including supply of above GI pipe and accessories. | — | 4.00 | — | — | |
| — | — | — | Above/ 149256.00 Below/P | ||
| Supply of BLDC Ceiling Fan of sweep 1200 mm, Air delivery range from 210 cubic metre per minute to 220 cubic metre perminute and input power consumption range from 26W to 32W ( Star Rating - 5 Star, Service Value - 6 & above cubic metre per minute per watt ) with copper winding and remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system ( conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable with BIS certification ) with 60 Months warranty including fixing,connection, testing and commissioning of ceiling fan & regulatorwith suitable clamping arrangement & 'S' hook etc.( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) | — | 72.00 | — | — | |
| — | — | — | Above/ 89280.00 Below/P | ||
| Supply, fixing, testing and commissioning of Modular Exhaust Fan as per IS: 2312 (or latest) Sweep Size-300 mm, White Colour, with Louver Shutter, Plastic Fiber body including fixing with GI clamps made of GI flat of suitable size & GI Nut, Bolts alongwith necessary Masonry works.( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) | — | 48.00 | — | — | |
| — | — | — | Above/ 56640.00 Below/P | ||
| Supply of AC Wall Bracket Fan 400 mm sweep suitable for operation on 1Ph, 220- 240V, 50 Hz supply system includingfixing, connection and commissioning with GI clamps madeof GI flat of suitable size and GI Nut-Bolts on wall / structure. ( Make : Havells / Usha / Orient / Halonix / Atomberg / Crompton / Bajaj ) | — | 24.00 | — | — | |
| — | — | — | Above/ 378480.00 Below/P | ||
| Supply, fixing, testing and commissioning of Storage Water Heater 5 star of capacity 25 Ltrs. suitable on 1Ph, 220-250V, 50 Hz supply system including fixing with GI clamps made of GI flat of suitable size & GI Nut, Bolts along 48with necessary Masonry works.( Make : Bajaj / Venus / Raycold / Havells / Crompton ) | — | 48.00 | — | — | |
| — | — | — | Above/ 154752.00 Below/P | ||
| Supply of Kitchen Chimney with Auto Clean, wall mounted of size 60 cm, 1200 Cu.Mtr./Hr. similar to Make : Kutchina, Model No. : Maple 60 Premium or equivalent including fixing, testing and commissioning with suitable arrangement. | — | 12.00 | — | — | |
| — | — | — | Above/ 9000.00 Below/P | ||
| Supply of MS Long Arm of size 4.5 Ft x 1.5 inch for fixing of LED Street / Flood light fitting including installation testing and commissioning. | — | 20.00 | — | — | |
| — | — | — | Above/ 60060.00 Below/P | ||
| Supply of GI Pipe of dia 4", 3 Mtr. long including installation and commissioning of above 4" dia GI pipe by hole cutting for installation of AC Machine. | — | 42.00 | — | — | |
| — | — | — | Above/ 5880.00 Below/P | ||
| Supply of GI Pipe cover of 5" dia for above 3M long GI pipe for closure of both sides of hole including fixing and commissioning. | — | 42.00 | — | — | |
| — | — | — | Above/ 115212.00 Below/P | ||
| Supply of SPN DB ( Metal Enclosure with Metal Door ), 14 way, 50Hz, complete with 10 nos. SP MCB of current rating from6A to 32A, 10kA, 240V, 50Hz as per requirement of load and1 no. DP RCBO of current rating 63A, 300mA, 10kA, 230V,50Hz ( Make of MCB, RCBO and Metal Distribution Board - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S / Havells ) | — | 12.00 | — | — | |
| — | — | — | Above/ 1452.00 Below/P | ||
| Fixing, connection and commissioning of above SPN MCB DB with suitable arrangement including all incoming and outgoing cable connection with suitable cable termination arrangement. | — | 12.00 | — | — | |
| — | — | — | Above/ 76000.00 Below/P | ||
| Trenching and laying of cable under ground by soil cutting Fixing, connection and commissioning of above (PE-100 grade, PN-10 or higher) alongwith refiling of trench by excavated soil and make good of surface as its original condition. ( Cable will be supplied by Railway ) | — | 500.00 | — | — | |
| — | — | — | Above/ 4250.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable alongwith make good of floor surface as its original condition after laying of cable( Cable will be supplied by Railway ) | — | 50.00 | — | — | |
| — | — | — | Above/ 56240.00 Below/P | ||
| Trenching and laying of cable underground by pucca floor / concrete cutting and commissioning of cable through 80mm dia GI pipe including supply of GI pipe alongwith make goodof floor surface as its original condition after laying of cable( Cable will be supplied by Railway ) | — | 80.00 | — | — | |
| — | — | — | Above/ 21600.00 Below/P | ||
| Drawing of cable on wall / structure with suitable size and shapeGI clamps including supply of suitable size GI Clamp and GI nut-bolts and commissioning of cable( Cable will be supplied by Railway ) | — | 540.00 | — | — | |
| — | — | — | Above/ 24720.00 Below/P | ||
| Trenching, laying under road / track through 50 mm dia GIpipe ( medium gauge ) including supply of GI pipe and commi-ssioning of cable including back filling of trench with excavatedsoil after laying of cable ( Cable will be supplied by Railway ) | — | 120.00 | — | — | |
| — | — | — | Above/ 2595.00 Below/P | ||
| Drawing of cable through one no. 2" dia, 3.0 Mtrs. longGI pipe ( Make - Tata / Jindal / Bansal ) for protectionof cable on pole with proper GI clamps and GI nuts & boltsincluding supply of GI pipe( Cable will be supplied by Railway ) | — | 3.00 | — | — | |
| — | — | — | Above/ 77520.00 Below/P | ||
| Supply of Single phase Two wire ( GPRS / RF ) Smart EnergyMeter as per IS-16444 (Part 1), Current Rating : 10-60A, Accuracy Class : 1.0, similar to Make - L&T EAIC (SEIPL), Model : Aurora or equivalent.( Please refer to detail Technical Specification ) | — | 12.00 | — | — | |
| — | — | — | Above/ 2676.00 Below/P | ||
| Installation of Single Phase Two wire ( GPRS / RF ) Smart Energy Meter as per IS- 16444 (Part 1), Current Rating : 10-60A,Accuracy Class : 1.0, similar to Make - L&T EAIC (SEIPL),Model : Aurora or equivalent including transparent poly-carbonate box with OPEC base cover. ( Please refer to detail Technical Specification ) | — | 12.00 | — | — | |
| — | — | — | Above/ 12696.00 Below/P | ||
| Implementation of cloud hosted Head End System and meterdata management web- based software per meter - One Timewith 2 years of Defect Liability Period ( DLP ).( Please refer to detail Technical Specification ) | — | 12.00 | — | — | |
| — | — | — | Above/ 18720.00 Below/P | ||
| Annual Maintenance Charges for 1 year( after 2 years of DLP ) inclusive ofa) Monthly SIM Charges for Meters / Gateway.b) License charges of HES & MDM.c) Software support.( 1st day count from the date of Go-Live )( 1 year x 1 No. = 1 Set )( Please refer to detail Technical Specification ) | — | 36.00 | — | — | |
| — | — | — | Above/ 15382.00 Below/P | ||
| Supply of Dust and vermin proof metal Busbar Chamber made of 16 SWG ( 1.6mm ) MS sheet duly powder coated consisting of 4 nos. tinned copper busbar of each bar ofcapacity 100 Amp, 4 way, suitable for 415V, 50Hz supplysystem including all accessories alongwith fixing, connection, testing and commissioning of incoming and outgoing cablesglanding, cable socketing and connection with all suitable arrangement.( Make - Havells / Standard / HPL / C&S / LK (L&T) / Indoasian ) | — | 2.00 | — | — | |
| — | — | — | Above/ 11850.00 Below/P | ||
| Supply of MCCB with Thermal - Magnetic Release of breakingcapacity 36 kA at 415V AC, 50Hz of capacity 25-32A / 32-40A / 40-50A, 4 Pole complete with metal enclosure with spreader terminals including fixing, connection, testing and commissioning.( Make - LK (L&T) /Siemens / ABB / Hager / Legrand /Schneider / C&S ) | — | 2.00 | — | — | |
| — | — | — | Above/ 27328.00 Below/P | ||
| Supply of energy efficient bore well submersible pump-motorset of pump discharge capacity approx.1.00 LPS ( approx. 850 GPH ) and discharge head 54 mtrs. ( approx. 177 feet ) complete with water cooled and water lubricated copper wire wound squirrel cage induction motor suitable for 1 Phase, 240 Volt, 50 Hz power supply system with stainless steel coupling and all other accessories such as suitable length 3 core flat copper conductor cable of size 2.5 sq.mm, 1100 Volt grade ( motor to starter panel ), total 60 mtrs. length 40 mm. dia heavy gauge GI column pipe, one non-return valve,two pairs erection clamps etc. alongwith one control panel consisting with MCB, single phase DOL starter, voltmeter, ammeter, water level indicator, LED indications etc. includinginstallation, testing and commissioning of above bore wellsubmersible pump-motor set.( Make of pump-motor set - KSB / Texmo / CRI / Kirloskar / Crompton / Calama )( Make of GI column pipe - Tata / Jindal / Bansal )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1.00 | — | — | |
| — | — | — | Above/ 25766.00 Below/P | ||
| Supply of energy efficient bore well submersible pump-motorset of pump discharge capacity approx.1.00 LPS ( approx. 850 GPH ) and discharge head 54 mtrs. ( approx. 177 feet ) complete with water cooled and water lubricated copper wire wound squirrel cage induction motor suitable for 1 Phase, 240 Volt, 50 Hz power supply system with stainless steel coupling and all other accessories such as suitable length 3 core flat copper conductor cable of size 2.5 sq.mm, 1100 Volt grade ( motor to starter panel ), total 60 mtrs. length 40 mm. dia heavy gauge GI column pipe, one non-return valve,two pairs erection clamps etc. alongwith one control panel consisting with MCB, single phase DOL starter, voltmeter, ammeter, water level indicator, LED indications etc.( Make of pump-motor set - KSB / Texmo / CRI / Kirloskar / Crompton / Calama )( Make of GI column pipe - Tata / Jindal / Bansal )( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 1.00 | — | — | |
| — | — | — | Above/ 1554216.00 Below/P | ||
| "Supply of LT Wall Mounted / Floor Mounted Double Door Cubical Outdoor type Distribution Panel Board made of 14 SWG ( 2mm ) MS sheet duly powder coated comprising with the following items for 250KVA to 300 KVA Load : a) MCCB, 4 Pole, ( 160 - 400 )Amp, 415V, 50Hz, 36kA, Microprocessor based release for O/L, S/C, E/F & Neutral protection Model : LK (L&T) DN3-400D160- 400 A, MTX2.0, CAT No. -CM93003OOOOAG or equivalent - 2 nos. b) MCCB, 4 Pole, ( 100 -250 )Amp, 415V, 50Hz, 36kA, Microprocessor based release for O/L, S/C, E/F & Neutral protection Model :- LK (L&T) DN2-250D 100-250A, MTX2.0, CAT No. -CM92151OOOOAG or equivalent - 2 nos. c) MCCB, 4 Pole, ( 40 - 160)Amp, 415V, 50Hz, 36kA, Microprocessor based release for O/L, S/C, E/F & Neutral protection Model : LK (L&T) DZ1-160D 40-160 A, iTRP3, CAT No. - DZ1F0160DXH1A or equivalent - 2 nos. d) MCCB, 4 Pole, ( 25 - 100 )Amp, 415V, 50Hz, 36kA, Microprocessor based release for O/L, S/C, E/F & Neutral protection Model : LK (L&T) DZ1-160D25-100 A, iTRP3, CAT No. -DZ1F0100DXH1A or equivalent - 6 nos. e) MCCB, 4 Pole, 400 Amp, 415V, 50Hz, 36kA, without protection release, used as buscoupler isolation. Model : LK (L&T) DN3B-400SD - 400 A, CAT No. -CM98412OOROOG or equivalent - 1 no. f) RCBO, 4 Pole, 32 Amp, 415V, 50Hz, 10kA, Sensitivities -300mA, Suitable for AC +Pulsating DC (Type A) +Harmonics - 4 nos.g) RCBO, 4 Pole, 63 Amp, 415V, 50Hz, 10kA, Sensitivities - 300mA, Suitable for AC + Pulsating DC (Type A) +Harmonics - 6 nos. h) Tinned Copper Busbar (4 Bar) each of capacity 600 Amps., 415V, 50Hz. - 1 set. i) Static Multifunction panel mounting Energy Meter suitable for operation on 3Ph, 415V, 50Hz supply, Accuracy CL1 and RS485 Communication port Model : LK (L&T) MFM 4410, CAT No.-WL441011OOOO or equivalent - 12 nos. j) CT of suitable ratio for MFM - 36 nos. k) LED indication lamp for 3-Phases for incoming feeders and ""ON, OFF & TRIP"" indication for all incoming and outgoing feeders - 64 nos. l) Petty Store for control cable, MCBs, gland, socket, fuse, push button,TNC switch, selector switch, rotary handle operating mechanism, spreader terminals, interlocking arrangement, auxiliary contacts, shunt release, terminal blocks & NO/NC relays etc.- 1 job m) Fabrication work for above panel - 1 job. complete with internal wiring by single core FRLS grade copper conductor cable of suitable size and 1100V grade."( Make - LK (L&T) / Siemens / ABB / Hager / Legrand / Schneider / C&S ) ( Make for Energy Meter - ABB / Schneider / Secure / Legrand / LK (L&T) / Genus / Conzerv /Elmeasure / Stelmec / HPL / Socomec / Anchor / C&S ) | — | 2.00 | — | — | |
| — | — | — | Above/ 77712.00 Below/P | ||
| Fixing, connection, testing and commissioning of above panelincluding all incoming and outgoing cables glanding, cable socketingand connection and construction of concrete foundation orsuitable wall hanging arrangement as per site condition withall associated accessories | — | 2.00 | — | — | |
| — | — | — | Above/ 86540.00 Below/P | ||
| Supply of GI ( minimum coating thickness 65 microns ) conical / octagonal ( minimum sheet thickness - 3mm ) Pole of overall length 7 M with single / double arm bracket, top cover, base plate including hinged door-inbuilt Junction box complete with copper bar, insulator, Hylam sheet for cable termination and fuse kit-kat / MCB ( Make - Utkarsh / B.P. Projects / Crompton / Bajaj / Surya ) | — | 10.00 | — | — | |
| — | — | — | Above/ 31160.00 Below/P | ||
| RCC foundation, erection and commissioning of above GI polewith construction of cement concrete muffing ( Cement : Stone :Sand = 1 : 2 : 4 ) with foundation accessories including earthingof pole with 1 no. of 50 mm dia, 3 M long GI pipe ( Make - TATA / Jindal / Bansal ) with necessary earth connection frompipe to pole by GI Strip / GI wire | — | 10.00 | — | — | |
| — | — | — | Above/ 3580.00 Below/P | ||
| Wiring of light point by 2 nos. single core HRFR / FRLS grade, PVC insulated, copper conductor cable of size 1.5 sq.mm, 1100V grade for phase and neutral through pole from inbuilt poleJunction Box's porcelain fuse kit-kat / MCB to light fitting alongwith 1 no. single core HRFR / FRLS grade, PVC insulated copper conductor cable of size 1.5 sq.mm, 1100V grade forEarth Continuity Conductor ( ECC ).( Make of Copper conductor cable - Anchor / KDK / Havells /Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 20.00 | — | — | |
| — | — | — | Above/ 91520.00 Below/P | ||
| Supply of Lightning Air Terminal with below specifications :a) Stainless Steel Material 316L which is suitable for corrosive Environmentb) CPRI (Government of India) Laboratory - Tested & Certified for 70kA (8/20 Micro Second)c) Lightning Impulse Current Tested - 100kA (10/350 micro sec) from NFC 17-102 Accredited International Lab.d) Triggering Time (delta T) = delta 60 micro secondse) Mechanical Test, Environment test ( Salt Mist Treatment, Humid Sulphurous atmosphere treatment )f) 20 Year Warrantyg) CE certifiedh) Protection Radius - 79 Metre ( Level IV / Standard )similar to Model - VTR/ESE/RP/79 or equivalentincluding installation, testing and commissioning.( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. ) | — | 1.00 | — | — | |
| — | — | — | Above/ 11730.00 Below/P | ||
| Supply of GI High Mast 5 Meter Long ( 3 Meter + 2 Meter )with below specifications :a) 58 mm outer diab) High Mast Pipe Wall Thickness 3.5 mmc) Base Plate 300mm X 300mm X 8mmincluding installation, testing and commissioningwhich includes necessary Mounting arrangementi.e. Guy Wire, U Clips, Insulators, Nut Bolt andFasteners etc. along with all other accessories.( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. ) | — | 1.00 | — | — | |
| — | — | — | Above/ 21428.00 Below/P | ||
| Supply of Single Core 70 sq.mm insulated Copper FlexibleDown Conductor cable tested by 100 kA impulse test at 10/350 Microsecond for connection from Air Terminal to Earth Pit including laying of cable with necessery metallic / PVC protective covering wherever exposed to human intervention with suitable arrangement, testing and commissioning of cable.( Make of Copper conductor cable - Anchor / KDK / Havells / Finolex / Gloster / KEI / Polycab / RR Kabel / Mescab ) | — | 22.00 | — | — | |
| — | — | — | Above/ 12963.00 Below/P | ||
| Supply of 6 Digit Mechanical Lightning Strike Counter withIP67 enclosure box which will count the number of strike events including installation, testing and commissioning.( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. ) | — | 1.00 | — | — | |
| — | — | — | Above/ 3338.00 Below/P | ||
| Supply of Test Link Box with IP67 enclosure box withaccessories including installation, testing andcommissioning.( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. ) | — | 1.00 | — | — | |
| — | — | — | Above/ 112464.00 Below/P | ||
| Supply of Maintenance Free Copper Bonded Solid EarthingRods with 25 kg Earth Enhance Compound with belowspecifications :a) Certified by CPRI and NABL Accredaited Labb) ROHS certifiedc) Low Carbon High Tensile Rodd) Length of Electrode 3000 mm (3 Meter)e) Rod dia 17.2 mmf) Molecular Copper Plating thickness 254 microns as per UL 467g) Connection terminal size 32 mm x 6 mm with 10 mm hole along with nut bolt and washerincluding installation, testing and commissioning as per RDSOspec. no. RDSO/SPN/197 ver. 1.0 or latest and conforming toRDSO Drg. No. SDO/RDSO/E&B/001 or latest.( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 12.00 | — | — | |
| — | — | — | Above/ 7908.00 Below/P | ||
| Supply of Heavy Duty Fiber Reinforced Polymers Pit Coverwith below specifications :a) Weight Carrying Capacity 5 Tonb) Lockable arrangementc) Top Dia 162 mmd) Bottom Dia 242 mme) Height 230 mmf) As per IEC 62561-5g) M5 Nut Bolts HDG 4.6, 30 mm length with 2 nos. of plain washerh) Tested by NABL Accrediated LABincluding installation, testing and commissioning.( Make : ABB / VTR / Raychem / Veraizen Earthing / Ennob / True Power Ltd. / OBO Bettermann ) | — | 12.00 | — | — | |
| — | — | — | Above/ 9948.00 Below/P | ||
| Earthing with 2 nos.of 50 mm diametre, 3.0 metres long heavy gauge GI pipe ( Make - Tata / Jindal / Bansal ) including construction of earth pit and necessary earth connection from pit by suitable Galvanized Iron ( GI ) strip.( For details not covered in this specifications, IndianStandard Code of Practice for earthing IS : 3043 - 1987,Reaffirmed - 1996 should be followed ) | — | 4.00 | — | — | |
| — | — | — | Above/ 1525424.00 Below/P | ||
| Design, manufacture and supply of Machine Room / Machine Room Less ( MRL ) (As per site condition), Gearless type operation Passenger Lift ( G + 6 ), 7 Stops, 7 Openings ( same side opening ), 08 Passenger capacity ( 544 Kgs with following features:- Load & Speed - about 544 Kg @ 1M/Sec complete with Variable Voltage Variable Frequency (VVVF) drive, Automatic Rescue Device ( ARD ) with battery backup, Electromagnetic type Breaking arrangement with brake liners and DC Voltage energization and spring tension closing, Driving Motor : PMSM (Permanent Magnet Synchronous Motor), Driving Ropes : Ropes with factor of safety 12 or above, Electrical Safety- 3 phase limit switch to protect against over travel, Single phasing preventer with a protection against phase sequence reversal, Full proof gate locks for landing doors, Car gate switch, Over speed Governor, Over speed safety device. Lift car comprises with SS Cabin hair line finish Car enclosure and centre opening hair line finish door, also furnished with UPS based Lithium-Ion Battery operated Emergency Light, LED Lights, Car ventilation automatic ON/OFF Fan, Alarm, Digital floor Indication, Push Button for each floor, On/Off switch, Fan switch, IP based CCTV camera inside lift car along with web based and mobile application for monitoring the footage alongwith all type data transferring facility to IR-Niyantrac platform via RS-485 port including all other associated accessories complying RDSO specification No. RDSO/2013/EM/SPEC/0016 (Rev '2') -2025 dated 25.09.2025 or latest complete with installation, testing and commissioning of above Lift including related civil work and scaffolding. | — | 1.00 | — | — | |
| — | — | — | Above/ 2330986.00 Below/P | ||
| Design, manufacture and supply of Machine Room / Machine Room Less ( MRL ) (As per site condition), Gearless type operation Passenger Lift ( G + 6 ), 7 Stops, 7 Openings ( same side opening ), 20 Passenger capacity ( 1360 Kgs with following features:- Load & Speed - about 1360 Kg @ 1M/Sec complete with Variable Voltage Variable Frequency (VVVF) drive, Automatic Rescue Device ( ARD ) with battery backup, Electromagnetic type Breaking arrangement with brake liners and DC Voltage energization and spring tension closing, Driving Motor : PMSM (Permanent Magnet Synchronous Motor), Driving Ropes : Ropes with factor of safety 12 or above, Electrical Safety- 3 phase limit switch to protect against over travel, Single phasing preventer with a protection against phase sequence reversal, Full proof gate locks for landing doors, Car gate switch, Over speed Governor, Over speed safety device. Lift car comprises with SS Cabin hair line finish Car enclosure and centre opening hair line finish door, also furnished with UPS based Lithium-Ion Battery operated Emergency Light, LED Lights, Car ventilation automatic ON/OFF Fan, Alarm, Digital floor Indication, Push Button for each floor, On/Off switch, Fan switch, IP based CCTV camera inside lift car along with web based and mobile application for monitoring the footage alongwith all type data transferring facility to IR-Niyantrac platform via RS-485 port including all other associated accessories complying RDSO specification No. RDSO/2013/EM/SPEC/0016 (Rev '2') -2025 dated 25.09.2025 or latest complete with installation, testing and commissioning of above Lift including related civil work and scaffolding. | — | 1.00 | — | — | |
| — | — | — | Above/ 1665197.00 Below/P | ||
| Goods & Services Tax ( at present @ 18% ) | Lumpsum | 1.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
3661clause.pdf
ATTACHMENT
Advancecorrectionslipsupto11.pdf
ATTACHMENT
GCC_April-2022.pdf
ATTACHMENT
TenderFormandAnnexuresnew.pdf
ATTACHMENT
HTLTstandardspecification.pdf
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
Annexure-VA.pdf
ATTACHMENT
3661Annexure-A.pdf
ATTACHMENT
3661ANNEXURE-1_1.pdf
ATTACHMENT
finalPassengerElevatorsignedRDSOREV- RDSO Spec
ATTACHMENT
TenderBookletLift.pdf
ATTACHMENT
RDSOSpec.-2025-09-25-finalPassengerElevatorsignedRDSOREV-21.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].