| # | Company | Amount |
|---|---|---|
| 1 | ₹33.6 Cr A 804 BABYLON TOWER VIP CHOWK PO RAVIGRAM RAIPUR CG 492006 MOB 91 9425515230 | ₹33.6 Cr |
Tender Value
₹40.7 Cr
Closing Date
31 Aug 2021, 11:00 amClosed
Upgradation of District Headquarter Hospital with 100 beds ICU & Trauma Care facility at Angul District, Odisha
NBCC/CPG/District-HQ-Hospital/Angul/2021/299
NBCC/CPG/District-HQ-Hospital/Angul/2021/299
Open Tender-Domestic
Civil Works General
Anugul, Odisha
₹59,000
Exempted
11 Aug 2021
11 Aug 2021
31 Aug 2021
31 Aug 2021
17 Sept 2021
SL.No. Description of Item OSR Amount in Rs. Non-Shedule Item Amount in Rs. Total Amount in Rs.
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
1 Earthwork Excavation
Earth work in all kind of soil within 50m. Initial
lead and 1.5m initial lift including rough dressing
and breaking clods to maximum 5cm to 7cm and
laying in layers not exceeding 0.3m in depth and as
(a) per the direction of the Engineer-in-charge. cum 2992.360 195.10 583809.44
Extra lift of 1.5m or part there of over the initial
lift of 1.5m in all kinds of embankments and road
(b) works and ordinary earth work in general. cum 1032.510 212.90 219821.38
2 Sand Filling
Filling in foundation, trenches and plinth with
river sand, well watered and compacted in layers
of 0.3 mtr, with top surface dressed and leveled to
proper gradient including cost of all materials,
conveyance, all taxes and royalties, loading and
unloading, including cost of all labour, sundries ,T
& P etc. All complete as per directions of the
Engineer -in-charge. cum 2141.550 639.80 1370163.69
Providing and laying of Cement Concrete of grade
1: 4 :8 (1cement : 4 sand : 8 graded stone
aggregate 40 mm nominal size ) of approved
quality from quarry mixing in concrete mixer
,lowering and compacting in proper thickness ,
watering & curing for the required period
.including all cost of labour
,material,conveyance,royalties and taxes ,sundries
,T & P etc. but excluding the cost of centering and
shuttering all complete as per the directions of
Engineer-in-charge. cum 218.280 4481.40 978199.99
Providing and laying of Cement Concrete of grade
1: 3 :6 (1cement : 3 sand : 6 graded stone
aggregate 20 mm nominal size ) of approved
quality from quarry mixing in concrete mixer
,lowering and compacting in proper thickness ,
watering & curing for the required period
.including all cost of labour
,material,conveyance,royalties and taxes ,sundries
,T & P etc. & including the cost of centering and
shuttering all complete as per the directions of
Engineer-in-charge. cum 410.280 4864.30 1995725.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
5 Antitermite Treatment
Providing anti-termite treatment using approved
quality of chemical emulsion, spraying the mixture
uniformly by sprayer as preconstructional anti
termite treatment and creating a chemical barrier
under and around the column pits, wall trenches,
top surface of plinth filling, junction of walls &
floors along with external perimeter of the
building, expansion joints, surrounding the pipes
and conduits etc. complete at the rate as directed
by the manufacturer confirming to IS:6313 (Part-
II) and as per direction of Engineer-in-charge
including cost of all materials, labour, taxes,
sundries, T&P etc. complete. (The payments shall
be made on the basis of actual plinth area of the
building at Ground Floor & vertical faces will not
be measured for payment.) Note:- The Contractor
shall have to furnish 10years Guarantee to maintain
the anti-termite treated area / structures free from
6 BACK FILLING
Filling available excavated earth (excluding rock)
in trenches plinth sides of foundation etc. in layers
not exceeding 20 cm in depth , consolidating each
deposited layers by ramming and watering, lead up
to 50m and lift up to 1.5 mt etc. including cost of
all labour, sundries T & P etc complete in all
respect as per the direction of Engineer-In-Charge. cum 3553.340 92.47 328565.51
RCC work M-25 grade as per approved designs
and drawings having a minimum compressive
strength (in work test) 25 N. / Square mm. in 15
cm. cubes at 28 days after mixing and test
conducted in accordance with I.S. 456 and I.S. 516
using 12 mm. to 20 mm. size black hard crusher
broken granite stone chips and screened and
washed sharp sand for mortar of approved quality
from approved quarry, washed and cleaned (20
mm. size chips not to exceed 25 % ) to be mixed
in concrete mixture with approved grade cement
including hoisting, lowering, laying and
compacting concrete by using vibrators, watering
and curing for 28 days and finishing the exposed
surface smooth providing grooves or beads
wherever necessary including cost, conveyance,
loading, unloading, royalties and taxes of all
materials and cost of all labours, sundries, T&P,
required for the work etc. complete in all respect
but excluding cost of centering & shuttering as per
direction of the Engineer in charge.
Foundation and plinth cum 1410.380 5520.80 7786425.90
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Terrace Floor cum 36.900 5934.00 218964.60
8 Reinforcement
Providing, fixing in position TMT Fe-500
reinforcement bars for RCC work of required
diameter of approved quality including
straightening, cutting, bending, binding, welding
and joining (if necessary) and tying the grills and
placing in position as required for R.C.C. work and
providing hoisting, lowering and laying including
cost, conveyance and taxes of tor steel and
binding wires of 18 gauge and labour required for
the work for bending, binding and tying the grills
in all heights as per the specification & direction of
Engineer -in-charge. (Linear measurements will be
taken & quantity will be calculated on standard
weight. Weight of binding wire will not be
considered for measurement.)
Foundation and plinth qntl 2820.760 8149.30 22987219.47
Ground Floor qntl 2130.354 8149.30 17360893.85
Terrace Floor qntl 73.983 8250.00 610355.63
9 Centering and Shuttering
Providing steel centering and shuttering(steel/ ply)
to required shape and size for all kinds of R.C.C.
works centering materials with all necessary
bracing, ties and supports with level centering
covered with 50 micron polythene
sheet/bituminous paper . as per the direction of
the Engineer -in-charge and dismantling and
removing the shuttering after the required interval
from the date of casting, including cost of all
materials with transportation, taxes, loading and
unloading etc. and all labour, sundries, T&P
scaffolding etc. complete.
Plinth Beam sqm 257.240 105.00 27010.20
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
10 Structural steel
Supplying of all types of structural steel confirming
to Fe410 B of IS:2062, fabrication, assembling,
erection / slewing / end launching of steel girders /
truss upto 15M height on substructure incl.
provision of trolly refuges, if required. Complete
as per approved drawing incl. one coat of Zinc
chrome primer to IS-104 & one coat of Zinc
chrome Red Oxide and 2 coat of enamel paint
(Approved colour from Asian, Berger, ICI Dulex)
to IS 2074 and painting as per IRS-B-1 on all
members, (Detailed fabrication and erection
drawings & launching methodology will be
prepared and got approved by the contractor from
TPL / client). Rate include fabrication of all types
of battens, bracing, ties, stiffeners, packing,
diaphrams, shop rivets / welding, T&F bolts, drifs,
shop welds, templates, jigs, fixtures, backup
supports, accessories, transporting various
components from fabrication shop. to site. Kg 59155.00 160.00 9464800.00
11 Galvanised iron profile sheets
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Supply and istallation of precoated galvanised iron
profile sheets (Size, shape and pitch of corrugation
as approved by engineer - in charge) 0.5mm +/-
5% total coated thcikness (TCT) thick zinc coating
120gsm as per IS:277 in 240mpa steel grade, 5-7
microns epoxy primer on both side of the sheet and
polyster top coat 15-18 microns. sheet should have
protective guard film of 25microns minimum to
avoid cratches while transportation and should be
supplied in single length upto 12m or as desired by
Engineer-in-charge. The sheet shall be fixed using
self drilling / self tapping screws of size (5.5mm x
55mm) with EPDM seal or with polymer coated 'J'
or 'L' hooks, bolts and nuts 8mm diameter with
bitumen and G.I limpet washers filled with white
lead complete upto any pitch in horizontal /
vertical or curved surfaces excluding the cost of
purlins, rafters and trusses , including cutting to
size & shape, wherever required. Sqm 536.00 950.00 509200.00
B. SUPERSTRUCTURE
1 Fly Ash Brick Masonary(1:6)(superstructure)
Providing Fly ash bricks masonry work using
(250mmx120mmx80mm size) having crushing
strength not less than 75Kg/Sqcm in cement
mortar (1:6). Immersing the bricks in water before
use in all necessary projection splays cutting,
circular moulding, corbelling etc. Including cost of
conveyance ,taxes & royalties, loading and
unloading of all materials & cost of all labour,
scaffolding ,watering & curing ,sundries, T & P
etc. complete as per the direction of Engineer-in-
Terrace Floor cum 234.480 5513.60 1292828.93
2 Fly Ash Brick Masonary(1:4)(superstructure)
Providing Fly ash bricks masonry work using
(250mmx120mmx80mm size) having crushing
strength not less than 75Kg/Sqcm in cement
mortar (1:4). Immersing the bricks in water before
use in all necessary projection splays cutting,
circular moulding, corbelling etc. Including cost of
conveyance ,taxes & royalties, loading and
unloading of all materials & cost of all labour,
scaffolding ,watering & curing ,sundries, T & P
etc. complete as per the direction of Engineer-in-
Ground Floor cum 70.170 4300.04 301733.71
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Second Floor cum 126.900 4772.70 605655.63
3 16 mm outside Plastering (1:6)
Providing 16mm thick cement plaster to the
surface of brick masonry wall with cement mortar
(1:6) including racking out joints, scraping and
cleaning the surface and finishing the plaster
surface smooth using wooden floats only to proper
plumbs and level and making grooves and beads to
give required ornamental finish as per drawings
including cost of all materials, conveyance, loading
and unloading, all taxes and royalties, all labour,
scaffolding, watering and curing, sundries and
T&P etc all complete as per direction of the
Engineer -in-charge
Ground Floor sqm 2038.340 200.90 409502.51
Second Floor sqm 2003.480 210.70 422133.24
Terrace Floor sqm 1456.788 221.10 322095.83
4 12 mm inside Plastering (1:6)
Providing 12mm thick cement plaster to the
surface of brick masonry wall with cement mortar
(1:6) including racking out joints, scraping and
cleaning the surface and finishing the plaster
surface smooth using wooden floats only to proper
plumbs and level and making grooves and beads to
give required ornamental finish as per drawings
including cost of all materials, conveyance, loading
and unloading, all taxes and royalties, all labour,
scaffolding, watering and curing, sundries and
T&P etc all complete as per direction of the
Engineer -in-charge
Terrace Floor sqm 792.570 155.20 123006.86
5 6 mm Plastering (1:4)
Providing 6mm thick cement plaster with cement
mortar of (1:4) to ceilings of roof slabs, stairs,
landings, chajja, shelves, columns, beams and lofts
etc. including roughening, scraping and cleaning
and finishing the plastered surface smooth using
wooden floats only to proper plumbs and level,
making grooves and beads to give required
ornamental finish as per drawings including cost of
all materials, conveyance, loading and unloading,
all taxes and royalties, all labour, scaffolding,
watering and curing , sundries and T&P etc all
complete as per direction of the Engineer -in-
Ground Floor sqm 3764.980 156.10 587713.38
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Second Floor sqm 3602.500 163.30 588288.25
Terrace Floor sqm 458.070 171.00 78329.97
6 Grading Concrete
Providing average 25mm thick grading Concrete
with (1:2:2) using 6mm black hard granite chips
using 2% water proofing cement compound of
approved quality over top of Roof, Terrace,
including cost of scaffolding, scraping and cleaning
the roof surface, plastering and finishing smooth to
proper slope and gradient including cost of all
materials, conveyance and sundries, T&P etc.
complete as per direction of the Engineer -in-
Terrace Floor sqm 3964.520 301.30 1194509.88
7 Water Proofing Treatment
Providing and laying water proofing treatment in
sunken portion of WCs,bathroom etc., by applying
cement slurry mixed with water proofing
cementcompound consisting of applying :(a) First
layer of slurry of cement @ 0.488 kg/sqm mixed
with water proofing cement compound @ 0.253
kg/ sqm. This layer will be allowed to air cure for
(b) Second layer of slurry of cement @ 0.242
kg/sqm mixed with water proofing cement
compound @ 0.126 kg/sqm. This layer will be
allowed to air cure for 4 hours followed with water
curing for 48 hours. The rate includes preparation
of surface, treatment and sealing of all joints,
corners, junctions of pipes and masonry with
polymer mixed slurry.
Second Floor sqm 693.932 283.10 196452.15
Terrace Floor sqm 3964.520 283.10 1122355.61
8 Vitrified Tile Flooring
Supplying, Fitting, Fixing Double charged
Vetrified Tile (600 x 600) of approved make
confirming to IS 13755 in floors treads or steps
and landing laid on 25mm thickbed of cement
mortar1:4(1cement : 4sand) filling joints with
white cement of approved quality including cost of
all materials labour T & P etc required for the
work all complete as per direction of Engineer in
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
9 Vitrified Tile Skirting
Supplying, Fixing Double charged Vetrified Tiles
(600 x 600)in Dados Skirting & Risers of Steps of
12mm thick cement plaster (1:3) jointed with neat
cement slurry mixed with pigments to match the
shade of the tiles including cost of all materials
labour T & P etc required for the work all
complete as per direction of Engineer in Charge.
Ground Floor sqm 186.411 1340.10 249809.38
Second Floor sqm 166.190 1369.90 227663.68
10 Anti static Flooring & Skirting
Providing and installation of iQ TORO SC Vinyl
Sheet Flooring manufactured by Tarkett with a
nominal thickness of 2mm as per ISO 24340 - EN
429 and width of 2m as per ISO 24341 - EN 426.
iQ TORO SC shall conform to requirement of ISO
10581 - EN 649. iQ TORO SC shall have binder
content of Type I as per ISO 10581, Fire resistance
of 8kW/m2 as per ISO 9239-1 and Class Bfl-S1 as
per EN 13501-1, Indentation of less than .03mm
as per ISO 24343-1 and EN 433, Slip Resistance
of R9 as per DIN 51130, greater than 0.3 as per
EN 13893. The static electrical discharge shall be
less than 2kV as per EN 1815. The electrical
resistance of the product shall be less than 10^8 Ω
as per EN 1081. The product does not contain
Pthalate based plasticizer and emission rate of
VOC is very low, measured after 28 days as per
EN 16516. TVOC and formaldehyde emissions are
below 10µg/m3. It is 100% REACH compliant.
The product is fit to be used in Class 34 in
Commercial and Class
43 in Industrial as per EN ISO 10874.The product
is installed using multi coloured welding rods to
ensure seamless finish. The average seam strength
shall be more than 240N/50mm as per EN 684.
Ground Floor sqm 230.130 2280.00 524696.40
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
11 Tac Tile and laying tactile tile (for vision
impaired persons as per standards) of size
300x300x9.8mm having with water absorption less
than 0.5% and conforming to IS: 15622 of
approved make in all colours and shades in for
outdoor floors such as footpath, court yard, multi
modals location etc., laid on 20mm thick base of
cement mortar 1:4 (1cement : 4 coarse sand) in all
shapes & patterns including grouting the joints
with white cement mixed with matching pigments
etc. complete as per direction(Tactile sample shall
be approved by Engineer-in-charge) Approved
Make: Jhonson Endura , Ultra Tile, Vyara
Ground Floor sqm 104.630 2108.96 220660.48
Second Floor sqm 89.610 2108.96 188983.91
12 Antiskid Flooring
Supplying, Fixing Antiskid Vetrified Tile (600 x
600) of approved make confirming to IS 13755 in
floors treads or steps and landing laid on 25mm
thickbed of cement mortar1:4(1cement : 4sand)
filling joints with white cement of approved quality
including cost of all materials labour T & P etc
required for the work all complete as per direction
of Engineer in Charge. (For New Work Only)
Ground Floor sqm 252.930 1555.50 393432.62
Second Floor sqm 154.000 1575.30 242596.20
13 Granite Flooring
Supplying & Fixing Granite tiles 20mm thick in
floors/ platform trades or steps and landing on 25
mm thick bed of Cement motar 1:1 Jointed with
neat cement slury moxed with pigment to match
the shades of the tiles including rubbing and
polishing including cost of all meterials etc.
Second Floor sqm 195.020 2291.40 446868.83
14 Antiskid Tile flooring
Providing & Fixing Floor tiles in floors, treads or
steps and landing on 25mm thick bed of cement
mortar 1:1 (1 cement : 1 sand) jointed with neat
cement slurry mixed with pigment to match the
shades on the tiles etc. complete.
Ground Floor sqm 175.450 806.20 141447.79
Second Floor sqm 208.280 823.90 171601.89
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
15 Glazed Dado
Providing & Fixing Glazed Tiles in Dados Skirting
&Risers of Steps of 12mm thick cement plaster
(1:3) jointed with neat cement slurry mixed with
pigments to match the shade of the tiles including
rubbing and polishing complete.
Ground Floor sqm 657.762 817.20 537523.11
Second Floor sqm 764.526 843.80 645107.04
16 Gypsum ceiling
Providing & fixing false ceiling at all heights with
GRG (Glass Fibre Reinforced Gypsum) false
ceiling tiles of Size 595x595 mm of approved
texture, design and patterns having moisture
content less than 2%, humidity resistance of 99%,
NRC0.50 to 0.75 as per IS 8225:1987, Non
combustible as per BS 476 (part 4)-1970 and light
reflectance of 85% (minimum) to be laid in true
horizontal level suspended on inter-locking metal
T-Grid of hot dipped galvanised iron section of
0.33mm thick (galvanized @ 120 grams per sqm
including both sides) comprising of main-T
runners of size 15x32 mm of length 3000 mm,
cross - T of size 15x32 mm of length 1200 mm
and secondary intermediate cross-T of size 15x32
mm of length 600mm to form grid module of size
600 x 600 mm, suspended from ceiling using
galvanised mild steel items (galvanizing @ 80
grams per sqm) i.e. 50 mm long, 8 mm outer
diameter M-6 dash fasteners, 6 mm dia fully
threaded hanger rod upto 1000 mm length and L-
shape level adjuster of size 85x25x2 mm.
Galvanised iron perimeter wall angle of size
24x24x0.40 mm of length 3000 mm to be fixed on
periphery wall / partition with the help of plastic
rawl plugs at 450 mm center to center and 40 mm
long dry wall wood screws. The work shall be
carried out as per specifications, drawing and as
per directions of the Engineer-in-Charge.
17 Grid ceiling
Providing fitting and fixing of false ceilling with
Aluminium anodised T Section No. 3215 with 2'-
0" center to center, L section No. 1705 upto 15
micron on 4 walls to be fixed by means of steel
screw and P.V.C plug and the Aluminium grid 2'-
0"x2'-0" suspended from ceiling etc complete
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Fully Glazed Door ( Ref. Hardware Set as per
specification H8, iCLEAN HOLLOW METAL
18 SYSTEMS Pvt. Ltd.)
Supplying and fixing-Fixing of Un-plasticised poly
vinyl chloride (UPVC) (FENESTA/NCL VEKA
LTD.) Casenent Door-60-Series duly
manufactured using UPVC reinforced profiles of
60mm x 55mm x 2.5mm for outer frames 102mm
x 60mm x 2.5mm casement Door Sash profile and
74mm x 60mm x 2.5mm mullion peofile capable
of mounting single glazing system, structurally
reinforced with hot dip galvanised up to 50
microns of minimum thickness of 2.0 mm
prefabricated & welded through fusion welding the
door sash shall be fitted with 12mm thick WPC
Board of Greenply make duly fixed with EPDM
weathering seal resistant accessories like clipping
locking system made of aluminium 1 No. per set of
sashes and th esystem isto be installed at the site
using anchor fasteners, silicon rubber sealant,easy
glazing/deglazing at site etc. including cost and
conveyance of all material, accessories, labour
charges, materials and product conforming to
ASTM D 638-14,EN-447-95 and other applicable
codes and standards. (Ref.-Office of the Engineer-
In-Chife (CIVIL), Odisha Nirman
Soudha,Bhubaneswar. Lt. No-16100)
Fire Door ( Ref. Hardware Set as per specification
H1, iCLEAN HOLLOW METAL SYSTEMS Pvt.
Ground Floor Each 24 51785.59 1242854.16
First Floor Each 25 51785.59 1294639.75
Second Floor Each 29 51785.59 1501782.11
Third Floor Each 19 51785.59 983926.21
Terrace Floor Each 6 51785.59 310713.54
Lead Door ( Ref. Hardware Set as per
specification H9 & H10, iCLEAN HOLLOW
21 METAL SYSTEMS Pvt. Ltd.)
Double Shutter Each 3 58267.00 174801.00
Single Shutter Each 1 37116.00 37116.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
22 Sal wood Choukath for Doors
Supplying, fitting and fixing in position well
seasoned & dressed Sal wood choukhats in doors
free from defects such as dead knots, flows etc. in
all floors including two coats of termite proof
wood preservatives to Rear surface of frames
which is in contact with concrete and masonry
surface fitted with 6 nos. of W.I. Clamps and
required screws of approved quality including
cutting legs to sizes, cutting holes in walls, fixing in
CC 1:2:4 including cost, conveyance, royalties and
taxes of all materials and cost of all labour,
sundries, T & P etc. required for the workall
complete as per the directions of Engineer -in-
Ground Floor cum 0.170 52987.50 9007.88
Supplying fitting and fixing in position 32mm thick
single leaf Grade-1 flush door confirming to
IS:2202 (part 01/1991) with select seasoned
timber and block board core framed with seasoned
hard wood battens and bonded at high pressure
with phonol formaldehyde resin under the cross
banding process, termite resistant and moisture
proof, including cost, conveyance, taxes of all
materials with 1mm thick laminate of approved
make on both side,1no of Aldrop, 3 nos of SS butt
hinges, 2 nos of tower bolt, PVC door stopper,
Buffer & SS handle as per the lay-out drawing and
specification given by the Architect, Including all
cost of labour, material, conveyance, loading,
unloading, T&P and painting the wooden surface
with an approved shade and finish etc all complete
as per directions of Engineer-in-charge.
Ground Floor cum 11.340 4702.05 53321.19
Providing and fixing Fiber Glass Reinforced
plastic (FRP) Door Frames of crosssection 90
mm x 45 mm having single rebate of 32 mm x 15
mm to receive shutter of 30 mm thickness. The
laminate shall be moulded with fire resistant grade
unsaturated polyester resin and chopped mat. Door
frame laminate shall be 2 mm thick and shall be
filled with suitable wooden block in all the three
legs. The frame shall be covered with fiber glass
from all sides. M.S. stay shall be provided at the
24 bottom to steady the frame.
Ground Floor rmt. 188.100 576.08 108361.45
Second Floor rmt. 267.300 576.08 153987.32
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
30 mm thick Fiberglass Reinforced Plastic
(F.R.P.) flush door shutter in different plain and
wood finish made with fire retardant grade
unsaturated polyester resin,moulded to 3 mm thick
FRP laminate all around, with suitable wooden
blocks inside at required places for fixing of
fittings and polyurethane foam (PUF)/Polystyrene
foam to be used as filler material throughout the
hollow panel, casted monolithically with testing
parameters of F.R.P. laminate conforming to table -
3 of IS: 14856,complete as per direction of
25 Engineer-in-charge.
Ground Floor sqm 59.850 3334.41 199564.60
Second Floor sqm 85.050 3334.41 283591.80
Providing and fixing 1mm thick M.S. sheet door
with frame of 40x40x6 mm angle iron and 3 mm
M.S. gusset plates at the junctions and corners, all
necessary fittings complete, including applying a
priming coat of approved steel primer.Using M.S.
angels 40x40x6 mm for diagonal braces
Ground Floor sqm 15.750 4428.15 69743.36
First Floor sqm 13.500 4428.15 59780.03
Second Floor sqm 13.500 4428.15 59780.03
Third Floor sqm 13.500 4428.15 59780.03
Terrace Floor sqm 15.120 4428.15 66953.63
27 UPVC SLIDING WINDOWS
Two track two panels sliding window made of (big
series) frame 67 x 50 mm & sash 46 x 62 mm both
having wall thickness of 2.3 ± 0.2 mm and single
glazing bead / double glazing bead of appropriate
(i) dimension . (Ref.-DSR-Page-549, Item-9.147D.3)
Ground Floor sqm 118.200 5826.15 688650.93
Second Floor sqm 154.560 5826.15 900489.74
Three track three panels sliding window with fly
proof S.S wire mesh (Two nos.glazed & one no.
wire mesh panels) made of (big series) frame 116
x 45 mm & sash 46 x 62 mm both having wall
thickness of 2.3 ± 0.2 mm and single glazing bead
/double glazing bead of appropriate dimension
(ii) (Ref.-DSR-Page-550, Item-9.147D.4)
Ground Floor sqm 25.920 7261.20 188210.30
Second Floor sqm 25.920 7261.20 188210.30
Terrace Floor sqm 12.960 7261.20 94105.15
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Providing and fixing factory made uPVC white
colour fixed glazed windows/ventilators
comprising of uPVC multi-chambered frame and
mullion (where ever required) extruded profiles
duly reinforced with 1.60 ± 0.2 mm thick
galvanized mild steel section made from roll
forming process of required length (shape & size
according to uPVC profile), , uPVC extruded
glazing beads of appropriate dimension, EPDM
gasket, G.I fasteners 100 x 8 mm size for fixing
frame to finished wall, plastic packers, plastic caps
and necessary stainless steel screws etc.Profile of
frame shall be mitred cut and fusion welded at all
corners, mullion (if required) shall be also fusion
welded including drilling of holes for fixing
hardware's and drainage of water etc. After fixing
frame the gap between frame and adjacent finished
wall shall be filled with weather proof silicon
sealant over backer rod of required size and of
approved quality, all complete as per approved
drawing & direction of Engineer-in-Charge.(Ref.-
(iii) DSR-Page-543, Item-9.147B)
Ground Floor sqm 9.000 5399.70 48597.30
First Floor sqm 16.200 5399.70 87475.14
Second Floor sqm 28.800 5399.70 155511.36
28 UPVC VENTILATORS
Supplying and fixing-Fixing of Un-plasticised poly
vinyl chloride (UPVC) (FENESTA/NCL VEKA
LTD.) Ventilators Top Hung-60-Series duly
manufactured using UPVC reinforced profiles of
60mm x 50mm x 2.5mm for outer frames, 75mm
for outer frames. 75mm x 60mm x 2.5mm for
casement window sash profile capable of mounting
single glazing system, structurally reinforced with
hhot dip galvanised up to 50 microns of minimum
thickness of 1.5 mm prefabricated & welded
through fusion welding the window sash shall be
fitted with EPDM weathering seal resistant
accessories like clipping locking system made of
aluminium 1 No. per set of sashes and th esystem
isto be installed at the site using anchor fasteners,
silicon rubber sealant,easy glazing/deglazing at site
etc. including cost and conveyance of all material,
accessories, labour charges, materials and product
conforming to ASTM D 638-14,EN-447-95 and
other applicable codes and standards.(Ref.-Office
of the Engineer-In-Chife (CIVIL), Odisha Nirman
Soudha,Bhubaneswar. Lt. No-16100)
Ground Floor sqm 13.200 7115.00 93918.00
First Floor sqm 11.520 7115.00 81964.80
Second Floor sqm 14.040 7115.00 99894.60
Third Floor sqm 12.360 7115.00 87941.40
Terrace Floor sqm 22.590 7115.00 160727.85
Supplying, fitting, fixing of M.S grills of approved
design and specification by using M.S. flat, angle,
square bar confirming to I.S. No. 1977/95 in
wooden choukath / brick wall with necessary nos
of screws as may be required including cutting
holes for clamps & fixing the grills with C.C.
(1:2:4) by using 12mm size H.G. chips wherever
necessary in all floors and all heights including
watering, curing ,scafolding with cost, conveyance,
taxes of all materials, cost of all labour, labour
cess, T&P etc required for the work complete in all
respect as directed by Engineer-In-Charge.
30 UPVC Window Glass
Coloured toungened glass 6mm thick substrate
with reflective soft coating on face # 2, + 12mm
Airgap + 6mm Heat Strengthened clear Glass of
approved make having properties as visible Light
transmittance (VLT) of 25 to 35 %, Light
reflection internal 10 to 15%, light reflection
external 10 to 20 %, shading coefficient (0.25-
0.28) and U value of 3.0 to 3.3 W/m2 degree K
etc. The properties of performance glass shall be
decided by technical sanctioning authority as per
the site requirement. SQM 766.08 3228.00 2472906.24
31 S.S Railing
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Supplying ,Fitting and fixing of stainless Steel of
304 grade in hand railing using 50mm dia of 2mm
thick circular pipe with Balustrade of size 32mm x
32mm x 2mm @ 0.90mtr C/C and stainless square
pipe bracing of size 32mm x 32mm x 2mm in 3
rows in stair case as per approved design and
specification, buffing, pollishing etc. with cost,
conveyance, taxes of all materials, labour, T&P
etc. required for the complete in all respect.
32 M.S Railing
Supplying ,Fitting and fixing of M.S hand rail of
approved size by welding etc. to steel ladder
railing, balcony railing, staircase railing and similar
works, including applying priming coat of
approved steel primer as per approved design and
specification, buffing, pollishing etc. with cost,
conveyance, taxes of all materials, labour, T&P
etc. required for the complete in all respect as per
the direction of Engineer in charge.
Ground Floor kg 641.376 109.29 70093.18
33 Synthetic Enamel Paint
Painting synthetic enamel paint of approved brand
and manufacture of required colour to give an
even shade with two or more coats on new work
over a coat of suitable shade with primer of
approved brand as per manufacturer's specification
including cost of all materials with taxes and
transportation, all labour, scaffolding, sundries,
T&P etc. All complete as per the direction of the
Engineer -in-charge.
Ground Floor sqm 153.120 187.16 28657.94
Terrace Floor sqm 15.750 207.60 3269.70
34 External Painting
Painting two coats with Water soluble weather
coat paints of approved shade of approved make
or equivalent over out side brick wall over a coat
of primer, by means of brush to outside surface of
new walls after scraping, cleaning the surface
including all cost of materials, scaffolding, labour,
watering & curing T&P etc complete as per
direction of Engineer -in-charge.
Ground Floor sqm 2038.340 127.20 259276.85
Second Floor sqm 2003.480 135.30 271070.84
Terrace Floor sqm 1456.788 143.60 209194.76
35 Internal Painting
Distempering two coats to walls with two coats of
putty and one coat of primer on the plastered
surface by means of rollers to give an even shade
including cost of all materials, labour,
conveyance, taxes, royalties, scaffolding, sundries,
T&P etc, All complete as per the direction of the
Engineer-in-charge
Terrace Floor sqm 1250.640 359.50 449605.08
36 Plinth Protection
Making plinth protection 50mm thick cement
concrete 1:3:6 over 75mm bed of dry brick ballast
40mm nominal size well rammed and consolidated
and grouted with fine sand including finishing the
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Manufacturing, Providing and Installation of
GFRC (Glass Fibre Reinforced Concrete)
Screens/Jalis, Make “SAMUDYAM”, of thickness
30 mm ±5 mm with Pattern, design, and colour of
approved make to be fixed on/between RCC
/Block work Column or structural work with Dry
Fixing method with appropriate frame work, using
fasteners, and necessary hardware etc. in Building
Façade. The element shall be made from '53 grade'
Portland Cement make Birla/ 'JK Cement' or
equivalent, Quartz, Fine Silica Sand, Alkali
Resistant Glass fibre make 'OC' or equivalent,
Super plasticisers / Additives make by 'BASF' or
equivalent, Polymers make 'BASF' or equivalent
and U.V resistant Synthetic inorganic pigments
shall be used for pigmentation make
'BAYFERROX (Germany)' or equivalent. The
material casting shall take place in Synthetic
Rubber / FRP Mould manufactured by Mould /
Tool / Mould Grade Resin of Revex/ 'Reckli' or
Providing & Installation of MS strututcural
(II) Support behind GFRC jalis Kg 10251.36 175.00 1793988.00
38 Structural Glazing
Designing, fabricating, testing, protection,
installing and fixing in position semi (grid) unitized
system of structural glazing (with open joints) for
linear as well as curvilinear portions of the building
for all heights and all levels, including: (a)
Structural analysis & design and preparation of
shop drawings for the specified design loads
conforming to IS 875 part III (the system must
passed the proof test at 1.5 times design wind
pressure without any failure), including functional
design of the aluminum sections for fixing glazing
panels of various thicknesses, aluminium cleats,
sleeves and splice plates etc. gaskets, screws,
toggles, nuts, bolts, clamps etc., structural and
weather silicone sealants, flashings, fire stop
(barrier)-cum-smoke seals, microwave cured
EPDM gaskets for water tightness, pressure
equalisation & drainage and protection against fire
hazard including: (b) Fabricating and supplying
serrated M.S. hot dip
galvanised / Aluminium alloy of 6005 T5 brackets
of required sizes, sections and profiles etc. to
accommodate 3 Dimentional movement for
achieving perfect verticality and fixing structural
glazing system rigidly to the RCC/
masonry/structural steel framework of building
structure using stainless steel anchor fasteners/
bolts, nylon seperator to prevent bimetallic
contacts with nuts and washers etc. of stainless
steel grade 316, of the required capacity and in
required numbers.
6mm Saint Gobain ST 167 toughen with digital
(I) print. on glass. sqm 40.00 7595.00 303800.00
(II) 6mm Saint Gobain ST 167 . sqm 256.00 5100.00 1305600.00
Providing and supplying aluminium extruded
tubular and other aluminium sections as per the
architectural drawings and approved shop
drawings , the aluminium quality as per grade
6063 T5 or T6 as per BS 1474,including super
durable powder coating of 60-80 microns
conforming to AAMA 2604 of required colour
and shade as approved by the Engineer-in-Charge.
( The item includes cost of material such as cleats,
sleeves, screws etc. necessary for fabrication of
extruded aluminium frame work. Nothing extra
(III) shall be paid on this account). Kg 1536.00 370.45 569011.20
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
1. Performance Laboratory Test for Air Leakage
Test (-50pa to - 300pa) & (+50pa to +300pa) as
per ASTM E-283-04 testing method for a range of
testing limit 1 to 200 mVhr 2. Static Water
Penetration Test. (50pa to 1500p) as per ASTME-
331-09 testing method for a range up to 2000 ml.
3. Dynamic Water Penetration (50pa to 1500pa) as
per AAMA 501.01- 05 testing method for a range
upto 2000 ml 4. Structural Performance Deflection
and deformation by static air pressure test (1.5
times design wind pressure without any failure) as
per ASTME-330-10 testing method for a range
upto 50 mm 5. Seismic Movement Test (upto 30
mm) as per AAMA 501.4- 09 testing method for
Qualitative test, Tests to be conducted on site. 6.
Onsite Test for Water Leakage for a pressure range
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Load / Speed: 26 Persons (1768Kgs.) / 1.25 Mtr.
Per Second Drive: MICRO PROCESSOR BASED
VVVF - CLOSED LOOP Travel / PIT /
HEADROOM: 12.6 METER / PIT 1600mm /
HEADROOM 4200 mm Number and Position of
Car Entrances: 1 (ONE), IN FRONT ONLY
Position of Machinery: DIRECTLY ABOVE THE
LIFT WELL -GEARLESS Size of Lift Well: 2400
X 3000 Lift Car Inside Size: 1600 X 2400 X 2200
Clear opening of Gates / Doors / Lintel: 1200 X
2000 Type or Design of Lift Car: STAINLESS
STEEL - HAIRLINE FINISH
Car Ceiling: Car Floor SLEEK (SMALL
CIRCULAR LIGHTS) - SS HAIRLINE FINISH -
ALUMINIUM CHEQ. PLATE FLOORING
Car Fittings: LED LIGHTS & REGULAR
(CIRCULAR) - FAN
Type of Car Front Entrance Protection: POWER
OPERATED SIDE OPENING SLIDING DOOR -
STAINLESS STEEL - HAIRLINE FINISH Land
Entrance Protection &Landing Door Frame: SIDE
OPENING SLIDING DOOR - STAINLESS
STEEL - HAIRLINE FINISH Type of Control
System: MICROPROCESSOR BASED SIMPLEX
SELECTIVE COLLECTIVE CONTROL WITH /
WITHOUT ATTENDENT Electric Supply: AC 3
PHASE, 50 CYCLES, 415 VOLTS ±10%
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
ABSTRACT ESTIMATE FOR EXTERNAL DEVELOPMENTAL WORK FOR UP GRADATION OF DISTRICT HEADQUARTER HOSPITAL WITH 100
BEDS, ICU & TRAUMA CARE FACILITY AT ANGUL DISTRICT, ODISHA.
A. SITE DEVELOPMENT
Cleaning & grubbing road land including
uprooting rank
vegetation,grass,bushes,shurbes,sapling and trees
girth upto 300mm ,removal of stumps of trees cut
earier and disposal of unsevicable materials and
stacking of servicable materials to be used or
auctioned up to lead of 1000 meters including
removal and disposal of top organic soil not
1 exceeding 150mm thickness. sqm 7985.952 5.72 45679.65
Surface dressing of the ground including removing
vegetation and in-equalities not exceeding 15 cm
deep and disposal of rubbish, lead up to 50 m and
lift up to 1.5 m.
:All kinds of soil sqm 11978.928 12.38 148299.13
3 Good Earth Filling
Flling with selected earth brought from borrow
pits, transporting to site, spreading in layers,
watering and compacting to meet requirement as
per direction of the Engineer in charge. sqm 1197.893 468.50 561212.78
4 Tree Cutting
Felling of tree, Arial branch cutting, Arial cross
cutting, posh & pull for higher calss (economical
& un-economical trees).
Under 90cm to 119cm girth nos R.O 1000
Under 150cm to 179cm girth nos R.O 2600
Under 180cm to 209cm girth nos 45 3300 148500.00
Under 240cm to 269cm girth nos R.O 6600
Under 300cm to 329cm girth nos R.O 9500
B. DISMANTLING WORK
1 Dismantling brick
Dismantling brick or stone masonry in lime or
cement mortar under 3m. height including stacking
the useful materials for reuse and removing the
debris within 50m. Lead cum 320.60 994.60 318872.74
2 Dismantling G.C.I. or A.C. sheet roof
Dismantling G.C.I. or A.C. sheet roofing after
carefully removing the bolts and nuts including
stacking of he materials for reuse and removing the
debris within 50m lead sqm 2579.56 68.90 177731.68
3 Dismantling doors, windows
Dismantling and removing doors, windows and
ventilators including removal of frame, hinges,
fastening and stacking the same for reuse and
removing the debris within 50m lead sqm 90.09 303.80 27369.34
ABSTRACT ESTIMATE FOR EXTERNAL & INTERNAL PH WORK FOR UP GRADATION OF DISTRICT HEADQUARTER HOSPITAL WITH 100
BEDS, ICU & TRAUMA CARE FACILITY AT ANGUL DISTRICT, ODISHA.
SL.No. Description of Item Amount
i. INTERNAL PHE WORKS 15520779.98
ii. EXTERNAL WATER SUPPLY & PUMPS 1815443.00
iii. EXTENAL SEWAGE 958326.40
iv. WATER TREATMENT PLANT - 12 CUM/HR 810000.00
SUB TOTAL 19104549.38
Qnty. Shedule Qnty. Non- Rate For Non-
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs.
A. INTERNAL PHE WORKS
Providing all materials, labour, T&P for laying of
following dia CPVC pipes S.D.R - 13.5 as per IS-
15778 with ISI mark including fixing of required
size CPVC fittings like,bend,Tee,elbow,offsets,etc.
and the same fixed on wall or floor with holder bat
clamps screw etc. including testing the joints with
required water presure.The cost inclusive of all
taxes,duties,transportation scaffolding etc. as per
specification and direction of Engineer-in-charge.
Hot water and inside the toitet - Make - Ashirwad,
1 Astral,Supreme
a 20mm diameter
Ground floor Rmt 96 190 18,240.00
Terrace floor Rmt 236 210 49,560.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
b 25mm diameter
Ground floor Rmt 0 261 -
1st Floor Rmt 0 266 -
2nd Floor Rmt 0 271 -
3rd Floor Rmt 0 276 -
Terrace floor Rmt 352 281 98,912.00
c 32mm diameter
Ground floor Rmt 0 372 -
1st Floor Rmt 0 377 -
2nd Floor Rmt 0 383 -
3rd Floor Rmt 0 388 -
Terrace floor Rmt 0 393 -
c 40mm diameter
Ground floor Rmt 0 450 -
1st Floor Rmt 0 455 -
2nd Floor Rmt 0 460 -
3rd Floor Rmt 0 465 -
Terrace floor Rmt 352 470 165,440.00
Providing and fixing to wall or ceiling and floor
pvc pipes conforming to ASTM-D-1785/89 (Sch-
40) and pipe fittings of the following nominal bore
with clamps including making good the wall,
ceiling and floor all complete as per
specification complete. Make - Ashirwad,
2 Astral,Supreme
a 20mm diameter
Ground floor Rmt 327 184 60,168.00
Terrace floor Rmt 208 205 42,640.00
b 25mm diameter
Ground floor Rmt 82 220 18,040.00
Terrace floor Rmt 305 250 76,250.00
c 32mm diameter
Ground floor Rmt 82 312 25,584.00
Terrace floor Rmt 286 332 94,952.00
d 40mm diameter
Ground floor Rmt 0 351 -
1st Floor Rmt 0 356 -
2nd Floor Rmt 0 361 -
3rd Floor Rmt 0 366 -
Terrace floor Rmt 230 371 85,330.00
e 50mm diameter
Ground floor Rmt 0 393 -
1st Floor Rmt 0 398 -
2nd Floor Rmt 0 403 -
3rd Floor Rmt 0 440 -
Terrace floor Rmt 128 445 56,960.00
f 65mm diameter
Ground floor Rmt 0 615 -
1st Floor Rmt 0 620 -
2nd Floor Rmt 0 625 -
3rd Floor Rmt 0 631 -
Terrace floor Rmt 68 636 43,248.00
g 80mm diameter
Ground floor Rmt 0 690 -
1st Floor Rmt 0 695 -
2nd Floor Rmt 0 700 -
3rd Floor Rmt 0 805 -
Terrace floor Rmt 352 710 249,920.00
h 100mm diameter
Ground floor Rmt 0 980 -
1st Floor Rmt 0 985 -
2nd Floor Rmt 0 990 -
3rd Floor Rmt 0 995 -
Terrace floor Rmt 352 1000 352,000.00
Providing and fixing to wall or ceiling and floor
pvc pipes conforming to ASTM-D-1785/89 (Sch-
80) and pipe fittings of the following nominal bore
with clamps including making good the wall,
ceiling and floor all complete as per specification
3 complete. Make - Ashirwad, Astral,Supreme
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
a) 65mm dia pipe
Ground floor Rmt 0 964 -
1st Floor Rmt 0 969 -
2nd Floor Rmt 0 975 -
3rd Floor Rmt 0 980 -
Terrace floor Rmt 0 1012 -
b) 50mm dia pipe
Ground floor Rmt 0 876 -
1st Floor Rmt 0 881 -
2nd Floor Rmt 0 886 -
3rd Floor Rmt 0 891 -
Terrace floor Rmt 164 896 146,944.00
Providing all material, labour,T&P for fitting &
fixing of following water supply fittings of Brass
Ball Valve with jointing materials etc. including
testing the joints with required water pressure. The
cost inclusive of all taxes, duties, transportation,
scaffolding etc. all complete as per
specification & direction of EIC. Make - Zoloto,
a) 65mm dia brass ball valve Nos 0 6729 -
b) 50mm dia brass ball valve Nos 0 3200 -
c) 40mm dia brass ball valve Nos 13 2700 35,100.00
d) 32mm dia brass ball valve Nos 74 1554 114,996.00
e) 25mm dia brass ball valve Nos 67 1250 83,750.00
f) 20mm dia brass ball valve Nos 102 613 62,526.00
Supplying, installing, testing and commissioning
butterfly valves with standard lever confirming to
IS 13039 with necessary connecting fittings like
flanges ,nuts and bolts etc., complete. as per
direction of Engineer- in-Charge. including testing
the joints with required water pressure. The cost
inclusive of all taxes, duties, transportation,
scaffolding etc. all complete as per specification &
5 direction of EIC. Make - Zoloto, Jainsons
Cutting grooves in pucca floors and walls for
taking GI/PVC pipes & making good the damages
6 as per specification complete. Rmt 2280 129 294,120.00
supplying all materials, labour, T&P and cutting
holes through existing brick work including
making good the damages in cement mortar (1:4)
for taking G.I. Pipes and fittings/ P.V.C. pipes
and fittings etc. all Nos 268 36 9,648.00
complete as per P.H. specification and direction of
7 Engineer-in-charge.
Providing all labour ,T&P for cutting holes in
R.C.C floors and roofs for passing G.I / P.V.C
pipes and fittings etc and repairing the holes after
inspection of pipes etc with cement concrete
(1:2:4) including finishing complete so as to make
it leak proof. including cost of all materials, curing,
conveyance, taxes, duties etc. all complete as per
specification Nos 428 110 47,080.00
8 & direction of Engineer-in-charge.
Providing all materials, labour, T&P for fitting and
fixing white glazed vitreous china water closet
(European pattern Coupled Closets) with solid seat
cover ,control plate & Cistern with Lid of standard
quality approved make including supply of sutaible
for EWC bolt & clamp including cost of all taxes
and conveyance as per specification all Nos 142 15540 2,206,680.00
9 complete as per direction of Engineer-in-charge.
JAQUAR- CNS-WHT-963SPP - EWC
JCS-WHT-2400S- CISTERN
JCP-CHR-292415 - CONTROL PLATE
Providing all materials, labour, T&P for fitting and
fixing white glazed vitreous china water closet (PH
toilet - European pattern Coupled Closets) with
solid seat cover ,control plate, grab bar & Cistern
with Lid of standard quality approved make
including supply of sutaible for EWC bolt & clamp
including cost of all taxes and conveyance as per Nos 8 21501 172,008.00
specification all complete as per direction of
10 Engineer-in-charge.
JAQUAR- CNS-WHT-963SPP - EWC
JCS-WHT-2400S- CISTERN
JCP-CHR-292415 - CONTROL PLATE
GRAB BAR 692mm LONG, WHITE -JAGUAR-
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
GRAB BAR VERTICAL SWING , WHITE -
JAGUAR- WAC-WHT-BG0800
Providing all materials and labour for fitting and
fixing of following size white glazed vitreous china
wash hand basin of approved make with supply &
fixing of basin bolts & screw,32mm PVC waste
pipe of approved quality including cutting the
walls & floor and making good the damages with
cement concrete (1:2:4) etc. with all taxes, duties, Nos 106 4811 509,966.00
transportation etc. all complete as per direction of
JAQUAR- OPS-WHT-15801- basin
Jaquar - ALD-CHR-769L250X190 -trap
JAGUAR- ALD-CHR-709 - waste coupling
Suplying all materials, labour. T&P for fitting and
fixing white glazed vitreous china ware porcelain
Orissa pattern water closet 580mm x 440mm x
290mm of approved make, confirming to IS-2556
with top inlet for sinking into floor with 100mm
HCI 'P' trap etc. including supply of necessary
cement concrete for fitting the closet etc. complete
in all respect in all floors including cost,
conveyance and taxes of all materials etc. complete
as per specification and as per direction of
Engineer-in-charge.
Make : HINDWARE/PARRYWARE/CERA
WITH ISI MARK Nos 18 8397 151,146.00
JAQUAR- CNS-WHT-OP01 - IWC
WHC-WHT-184NL - CISTERN
40 MM LONG FLUSH PIPE FOR IWC
Providing all materials and labour for fitting and
fixing of following size white glazed vitreous china
wash hand basin of approved make with supply &
fixing of basin bolts & screw,32mm PVC waste
pipe of approved quality including cutting the
walls & floor and making good the damages with
cement concrete (1:2:4) etc. with all taxes, duties, Nos 72 5952 428,544.00
transportation etc. all complete as per direction of
JAQUAR- CNS-WHT-705- under counter basin
Jaquar - ALD-CHR-769L250X190 -trap
JAQUAR- ALD-CHR-709 - waste coupling
Providing all materials , labour ,T&P and fittings
and fixing of different water supply (CP on Brass)
fitting as per IS specification & approved make of
following sizes and specification with leak proof
threaded joints with threadseal tape or any other
method as required, including all taxes, duties,
transportation etc., testing and rectification of
defects after testing complete as per direction of
13 Engineer-in-charge. Make : Hindware/Jaquar.
15mm dia CP Bib cock (short body)with wall
JAGUAR- CON-CHR-037KN
b) 15mm dia CP Angle stop cock with wall flange Nos 448 730 327,040.00
JAGUAR- CON-CHR-053KN
c) 15mm C.P.Pillar Cock Nos 178 1852 329,656.00
JAGUAR-FLR-CHR- 5031NG
d) CP Soap dish Nos 126 1395 175,770.00
JAGUAR-ACN-CHR-1131N
e) CP square Towel Ring Nos 178 1050 186,900.00
JAGUAR-ACN-CHR-1121N
f) CP Toilet Paper Holder Nos 168 646 108,528.00
JAGUAR- ACN-CHR-1151N
g) CP 20mm dia x 610mm long towel rod Nos 51 1173 59,823.00
JAGUAR- ACN-CHR- 1111SM
h) 15mm dia steel braided connection pipe Nos 448 307 137,536.00
JAGUAR- ALD-805B
i) 15mm dia Sink Cock Nos 9 3993 35,937.00
JAGUAR-FLR-CHR- 5166GD
SINK MIXTURE WALL MOUNT(Flr-5163 of
Overhead shower Round shape Multi Flow (ABS
Body) chrome plated with Gray Face Plate)with
Rubit Cleaning System & Shower Arm casted 190
mm long Flat shape for wall mounted Showers
k) with Flange. . (OHS CHR-1995+SHA-CHR-483) Nos 51 2362 120,462.00
l) Wall MIXTURE(FLR-5273UPR OF JAQUAR) Nos 23 4774 109,802.00
m) Conceld stop cock(CON-CHR-078KN) Nos 28 1378 38,584.00
Two-way Bibcock with wall Flange. (As per Cat
n) no.FLR-5041N of Jaquar) Nos 160 1673.3 267,728.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Health Faucet ABS SS braided hose 1.00m with
CP hook. (As per Cat
o) no.ALD-CHR-585 of Jaquar) Nos 160 1033.5 165,360.00
32 mm CP Double Coat Hook. (As per Cat
p) no.ACN-CHR-1161N of Jaquar) Nos 168 467 78,456.00
Supplying, Installing, testing and commissioning
stainless 'steel sink with single bowl without drain
board 'manufactured from 1mm thick stainless
steel, 18G 'grade indestructible chrome nickel steel
with top quality 'polish, 1no.40mm dia CP waste
coupling, with 1 no. 40mm 'dia CP bottle trap with
extension pipe, 15mm dia CP sink 'cock with
swivel spout wall mounted type and necessary
'wall flanges etc., complete. Size : 610x510mm ( 4
14 LPM @ 3 bar ) Make - Nirali Nos 9 4992 44,928.00
14a Scrub with all complete accessories Nos 6 30000 180,000.00
Supplying, Installing, testing and commissioning
ceramic labortory sink with 1no.40mm dia CP
waste coupling, with 1 no. 40mm 'dia CP bottle
trap with extension pipe, complete. Size :
Jaquar - ALD-CHR-769L250X190 -trap
JAGUAR- ALD-CHR-709 - waste coupling
Providing all materials , labour ,T&P and fittings
and fixing of Following Size on Extension piece
(S.S/CP on Brass) approved make of following
sizes and specification with leak proof threaded
joints with spun yarn and white zinc or any other
method as required including all taxes, duties,
transportation etc., testing and rectification of
defects after Nos 200 46 9,200.00
testing complete as per direction of Engineer-in-
15mmx65mm C.P./S.S Extension piece
Providing all materials, labour & fitting and fixing
100mm PVC multi floor trap with cement mortar
(1:4) with all taxes, duties etc. all complete as per
specification & direction of Engineer-in-charge.
16 Make - Ashirwad, Astral, Supreme Nos 0 258 -
a) 100mm PVC multi floor trap
Supplying, fixing and testing SS frame and
cover(grating) on PVC 'P' trap with fixed on a
bed of cement concrete with (Heavy duty type)
16a etc., complete. Nos 412 498 205,176.00
Providing all materials, labour, T&P for fitting and
fixing of UPVC SWR pipes (Type-B) confirming
to IS-13592/1992 with latest revision & ISI mark
both below & above ground level or fixing on wall
surface upto 3rd floor roof including scaffolding
wherever necessary with requisite testing. The cost
inclusive of all taxes, transportation, loading &
unloading etc. all complete as per specification &
direction of the Engineer-in-charge. Make :
ASTRAL/ORIPLAST/SUPREME/EQUIVALENT
a 75mm diameter
Ground floor Rmt 0 375 -
1st Floor Rmt 0 378 -
2nd Floor Rmt 0 381 -
3rd Floor Rmt 0 386 -
Terrace floor Rmt 720 391 281,520.00
b 110mm diameter
Ground floor Rmt 158 531 83,898.00
Terrace floor Rmt 1602 548 877,896.00
Providing all materials, labour, T&P, fitting and
fixing of following dia UPVC SWR fittings of
approved make confirming to IS 14735/1992 with
ISI mark both below & above ground level or
fixing on wall surface upto 3rd floor roof including
scaffolding wherever necessary with requisite
testing. The cost inclusive of all taxes,
transportation, loading & unloading etc. all
complete as per specification & direction of the
Engineer-in-charge. Make : Ashirwad/
ASTRAL/ORIPLAST/SUPREME/EQUIVALENT
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
c 110mm Cross Tee Nos 678 361 244,758.00
d 110mm Single Tee with door Nos 349 427 149,023.00
e 110mm Single Tee Plain Nos 421 365 153,665.00
f 110mm Plain Bend Nos 348 235 81,780.00
g 110mm Door Bend Nos 497 292 145,124.00
h 110mm Vent Cowl Nos 42 100 4,200.00
i PVC clamp suitable for 110mm dia pipe Nos 975 85 82,875.00
j 110x75 Reducing Y without door Nos 374 387 144,738.00
k 75mm Cross Tee Nos 78 273 21,294.00
l 75mm Single Tee Plain Nos 121 204 24,684.00
m 75mm Plain Bend Nos 58 186 10,788.00
n 75mm Door Bend Nos 87 224 19,488.00
o 75mm Vent Cowl Nos 18 74 1,332.00
p PVC clamp suitable for 75mm dia pipe Nos 725 77 55,825.00
q 75 mm End cap Nos 45 109 4,905.00
s 75 mm threaded cleanout plug Nos 12 163 1,956.00
t 110 mm threaded cleanout plug Nos 54 311 16,794.00
Providing all materials, labour, T&P for fitting and
fixing of UPVC 6 kg/cm2 pressure pipes IS4985
for waste connection from wash basin,kitchen
sinks with latest revision & ISI mark both below &
above ground level or fixing on wall surface upto
8th floor roof including scaffolding wherever
necessary with requisite testing. The cost inclusive
of all taxes, transportation, loading & unloading
etc. all complete as per specification & direction of
the Engineer-in-charge. Make : Ashirwad/
ASTRAL/ORIPLAST/SUPREME/EQUIVALENT
a 40mm dia UPVC pressure pipe
Ground floor Rmt 202 510 103,020.00
b 50mm dia UPVC pressure pipe
Ground floor Rmt 98 570 55,860.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Supplying, fixing and testing PVC rain water
collection kurra with leaf trap grating made out of
UPVC with flange complete.(Roof Corner Outlet
Pasted Type Fitting)Make - Ashirwad, Astral,
Cement Concrete (1:4:8) for Terrace pipes
Providing and fixing , testing and commissioning
of white glazed large flat back urinals with
URINAL WITH FIXING ACCESSORIES SET
with SENSOTRONIC CONCEALED TYPE
FLUSHING VALVE FOR URINAL COMPLETE
SET WITH INSTALLATION BOX WITH
CONTROL COCK & FLOW RESTRICTOR
1.4LPF AT 3 BAR PRESSURE with 32mm dia
CP waste coupling with dome type grating, 32mm
dia CP bottle trap with extension pipe, urinal
spreader, SS bolts and nuts to fix the urinal with
hangers and brackets complete with wall flanges
Urinal set -JAGUAR-URS-WHT13253N
Sensor -JAGUAR-SNR-STL51087G
Fixing 600x450mm bevelled edge mirror of
superior glass mounted on 6mm thick A.C sheet or
plywood sheet and fixed to wooden plugs with
Chromium Plated brass screws and washers
complete as per specification and direction of the
23 Engineer in charge Nos 192 723 138,816.00
Providing & Fixing stone slab with Table rubbed,
edges rounded and polished of size 75x50 cm deep
and 18mm thick, fixed in urinal partitions by
cutting a chase of appropriate width with chase
cutter and embedding the stone in the chase with
epoxy grout or with cement concrete 1:2:4 as per
24 direction of Er-in-charge. Nos 88 1344 118,272.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Supply,installation,testing and commissioning of
package type RO plant complete with pre-
treatment system NGMF-20 comprising of 01 no
of feed water pumps,dosing systems,RO
membrance,RO high pressure pumps,01 No.of
1000 liters SS treated water storage tank
etc.complete. The unit shall have all interiocking
for safe operation of plant. The unit shall have skid
mounted electrical panel complete with required
starters and shally also have all Annuanciation and
controls. The piping shall be heavy duty PVC. The
filter shall be FRP and pumps shall be of SS/CI
construction. The basis of design shall be for feed
water inlet TDS of 1200 PPM. Contractor is
suggested to cary out the feed water chemical
analysis and ensure suitability of RO plant
25 operation. Make-Ion Exchange.Thermax Nos 1.00 185000.00 185,000.00
Supply,installation,testing and commissioning of 3-
phage 50HZ Electric water heater INTEGRA-
26 S,SPLIT HEAT PUMP +Storage tank Nos 2.00 210169.49 420,338.98
Supply,installation,testing and commissioning of
Grundfos magna 3 25-60 circulatory and pressure
27 regulatory pump Nos 1.00 219032.00 219,032.00
B. EXTERNAL WATER SUPPLY & PUMPS
Providing and fixing to wall or ceiling and floor
pvc pipes class conforming to ASTM-D-1785/89
(Sch-40) and pipe fittings of the following nominal
bore with clamps including making good the wall,
ceiling and floor all complete as per
specification complete.Make : Ashirwad/
ASTRAL/ORIPLAST/SUPREME/EQUIVALENT
a 65 mm dia Rmt 0 962 -
b 65 mm dia Rmt 0 248 -
Supplying, fixing and testing Puddle flanges for
inlet, outlet, vent and overflow pipes, fittings with
D.I frame and cover to overhead water tank and
under ground water tank complete with steps as
2 shown on the drawings etc., complete. Lot 1 301943 301,943.00
i) DI manhole frame and cover (medium duty)
(weight=15 KN.) with locking facility - 14 nos -
(ii)150mm dia - 4 nos -
(iii)80 mm dia - 4 nos -
(iii)100 mm dia -2 nos -
(v) 65 mm dia -8 nos -
(vi) 50 mm dia -8 nos -
(vi) 32mm dia -14 nos -
viI) step ladder (Aluminium ladder) -14 nos -
(vii) 250mm dia -2nos -
(viii) 200mm dia -2 nos -
Supplying, installing, testing and commissioning
butterfly valves with standard lever confirming to
IS 13039 with necessary connecting fittings like
flanges ,nuts and bolts etc., complete. as per
direction of Engineer- in-Charge. including testing
the joints with required water pressure. The cost
inclusive of all taxes, duties, transportation,
scaffolding etc. all complete as per specification &
3 direction of EIC. Make - Zoloto/Audco/Jainson -
Supplying, installing and commissioning approved
make CI /CS flanged brass `Y' strainer with
necessary nuts and bolts, neoprene rubber gaskets,
4 flanges, etc.., complete.- Make- Zoloto/Jainson -
Supplying, fixing in position approved make CI
non-return valve conforming to IS codes with
conplete accessories etc., complete.- Make-
5 Zoloto/Jainson -
Supplying, installing, testing and commissioning
approved make water level controller with alarm
for the Underground Sump. The quoted rate shall
include for necessary wiring in PVC conduit
between the control panel, underground sump and
6 overhead tank.(length of cable approx. 60 mts.) nos 6 3926 23,556.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Providing ,fixing , testing and commissioning of
Monoblock type Domestic Water lift pumps set 2
no ’ s (1 Working + 1 Standby) to OHT
Centrifugal End Suction Close Couple pumps of
Water Flow Rate of each pump 40 cum/hr with the
head of 40 MWC adequate the casing shall be cast
iron and impeller shall be Stainless steel the pump
HP capacity shall be provided by manufacturer at
suitable head to work on 3Ph, 50Hz, 400/440V
with necessary unions, flanges, foundation bolts,
RCC footing in 1:2:4 etc. complete. Vendor shall
consider he electrical control panel comprising of
all accessories such as MCB ,isolation valve,non
return valve, pressure switches, pressure
transducers, control wiring & End terminations ,
earth strip of GI 25 x 3 mm,cable tray and any
other necessary imports etc. complete. water
7 supply ( GRUNDFOS) -
1 Working + 1 Stand-by) - Cap : 40Cum/hr @ 40
Pressure switch Nos 2 3000 6,000.00
Pressure guage Nos 2 1000 2,000.00
Control panel Nos 1 50000 50,000.00
Control cable as per OEM Rmt 40 150 6,000.00
Cable tray Rmt 40 750 30,000.00
Providing ,fixing , testing and commissioning of
Monoblock type Flushing Water lift pumps set 2
no ’ s (1 Working + 1 Standby) to OHT
Centrifugal End Suction Close Couple pumps of
Water Flow Rate of each pump 2 cum/hr with the
head of 30 MWC adequate the casing shall be cast
iron and impeller shall be Stainless steel the pump
HP capacity shall be provided by manufacturer at
suitable head to work on 3Ph, 50Hz, 400/440V
with necessary unions, flanges, foundation bolts,
RCC footing in 1:2:4 etc. complete. Vendor shall
consider he electrical control panel comprising of
all accessories such as MCB ,isolation valve,non
return valve, pressure switches, pressure
transducers, control wiring & End terminations ,
earth strip of GI 25 x 3 mm,cable tray and any
other necessary imports etc. complete. (
8 GRUNDFOS) -
(1 Working + 1 Stand-by) - Cap :20 Cum/hr @
Pressure switch Nos 2 3000 6,000.00
Pressure guage Nos 2 1000 2,000.00
Control panel Nos 1 50000 50,000.00
Control cable as per OEM Rmt 40 150 6,000.00
Cable tray Rmt 40 750 30,000.00
Sump pumps (Non-clogging type) in Pump
Supply, installation, testing and commissioning
KIRLOSKAR / GRUNDFOSS / WILO /
XYLEM make open well Submersible type non-
clogging Pump motor set of required drive
(Motor HP), having discharge capacity and
pumping head as described below with all
electrical accessories viz.main switch and starter,
auto on/off system with float arm (with fixed or
flexible arm), over load protection relay, power
cable and control cable from main switch and
starter with auto on-off with dry running protection
to respective motors, earthing having required
M.S. galvanised supporting stay/ clamp etc.
9 complete operational. -
(i) A set of two nos Sump pumps (Non-clogging
type) having discharge capacity of each pump
approx. 10 cum/hr at 15 m. pumping head (1
working, 1 standby) Suction from sumps in
underground pump house, delivery to surface
drain at ground level. Including MCC and allied
works (FIRE & PHE PUMP ROOM) Set of 2 1 200,000 200,000.00
(ii) A set of two nos Sump pumps (Non-clogging
type) having discharge capacity of each pump
approx. 10 cum/hr at 15 m. pumping head (1
working, 1 standby) Suction from sumps in
underground pump house, delivery to surface
drain at ground level. Including MCC and allied
works (STP PUMP ROOM) Set of 2 1 200,000 200,000.00
Supplying, installing and commissioning approved
make brass garden valve necessary nuts and bolts,
neoprene rubber gaskets, flanges, etc.., complete.-
10 Make- Zoloto/Jainson Nos 0 1149 -
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Providing and fixing water meter with direct
reading dial in KL with all integral parts of gun
metal or brass with necessary fitting such as
threaded pieces, unions pressure gauge and
isolation cock,
flanges piece for future removal, flanges/unions
11 complete. Nos 2 8016 16032
Supplying, fitting and fixing G.I. pipes with all
necessary accessories, specials viz. socket, bend,
tee, union, cross, elbo, nipple, longscrew, reducing
socket, reducing tee, short piece etc. fitted with
holder bats clamps, including cutting pipes,
making threads, fitting, fixing etc. complete in all
respect including cost of all necessary fittings as
required,jointing materials and two coats of
painting with approved paint in any position above
ground. (Payment will be made on the centre line
measurements of total pipe line including all
specials. No separate payment will be made for
accesories, specials. Payment for painting will be
12 made seperately) -
100 mm dia SUMP PUMP DISCHARGE LINE Metre 42 1,350 56,700.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
C. EXTENAL SEWAGE
Providing all materials, labour, T&P for fitting and
fixing of UPVC 6 kg/cm2 pressure pipes IS4985
for waste connection with latest revision & ISI
mark both below & above ground level or fixing
on wall surface upto 2nd floor roof including
scaffolding wherever necessary with requisite
testing. The cost inclusive of all taxes,
transportation, loading & unloading etc. all
complete as per specification & direction of the
Engineer-in-charge. Make: Ashirwad/
ASTRAL/ORIPLAST/SUPREME/EQUIVALENT
iii 315 mm dia R/M 0 2242 -
iv 280 mm dia R/M 0 959 -
vi 200 mm dia R/M 0 795 -
viii 110 mm dia R/M 0 374 -
Providing all materials, labour, T&P required for
construction of RCC M-25 man hole chamber of
following sizes having cube strength 250 Kg/cm2
at 28 days confirming to IS-456/2000 & IS-3370
at all locations & height using h.g. stone aggregate
(Crusher broken) of 20mm & down size including
machine mixing, lifting, hoisting, conveying,
placing in position, mechanical consolidation,
curing, de-watering (if required). The minimum
thickness of RCC base slab, all side walls & roof
slab shall be not less than 150mm & 125mm (avg.)
respectively. The cost shall be inclusive of rigid,
levelled & plumbed centering & shuttering to
required slope, allignment & size for all kinds of
RCC work with steel/ ply centering materials with
all bracing, ties, anchorage & supports and
removing the same after required paid & placing
M.S.Reinforcement HYSD bar of required dia
including cutting, bending, straightening of
approved quality as per approved design &
drawing & tying the grills for RCC works &
placing in position using binding wires (18 to 20
2 gauge soft drawn & cold annealed).
PCC 1:3:6 with 40mm size h.g.c.b. metal of
100mm thick, moulding & shaping the channel &
benching with C.C. 1:2:4 with 12mm size h.g.c.b.
chips, 12mm thick cement plaster 1:3 with cement
punning on inner wall surface, earth work
excavation in all types of soil/rock including
cement concrete cutting as per site condition,
filling the foundation base with sand duly watered
& rammed, providing, fitting & fixing of pre-cast
factory made man hole cover with frame (SFRC
medium duty) for clear opening 500mm dia,
providing, fitting & fixing of poly propylene steel
reinforced man hole steps of approved quality &
size in two parallel line of 300mm spacing in
vertical wall with centre to centre 375mm
(staggered) etc.all complete as per specification &
direction of EIC.
Manhole chamber of Inner size 900mmx1200mmx
a) 900mm depth. NOS 0 23332 -
Extra for every additional depth of 0.10mtr. or part
there of manhole size 900mmx1200mm from
b) 900mm depth upto 2500mm depth. NOS 0 12713 -
Manhole chamber of Inner size 900mmx900mmx
c) depth upto 1500 mm NOS 25 25000 625,000.00
Manhole chamber of Inner size 600mmx600mm
d) with heavy duty cover NOS 0 16728 -
Manhole chamber of Inner size450mmx450mmx
e) depth upto 1500 with heavy duty cover NOS 9 5343 48,087.00
Supplying all materials, labour, T&P and
constructing Gully Trap chamber of the following
inside size with 8cm thick R.C.C precast cover
slab in cement concrete (1:2:4) mix using 12mm
size h.g chips, foundation concrete (1:4:8) using
40mm size hard granite metal on bed and around
trap, Fly ash brickwork in c.m (1:6) in F&P and
inside 12mm thick cement plastering (1:3) finished
with a floating coat of neat cement including
fixing 100mmx100mm size HCI gully
trap,150mmx150mm size C.I grating etc all
complete as per approved drawing, specification
2A and direction of the Engineer in charge
Gully trap chamber (250x250MM) wth rcc cover
TOTAL 958326.40
D. WATER TREATMENT PLANT - 12 CUM/HR
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Design, Supplying, installing, testing and
commissioning of water teratment plant (WTP).
1 With below mentioned specifications.
Pressure sand filter of FRP construction with
necessary equipment complete with Frontal piping,
valves, suitable supports for mounting, pressure
guage, orifice plate, filtering media, etc..,complete
as per the detailed specification for the efficient
working of system.
a) Maximum working Pressure shall be
b) Back wash duration - 15 minutes.
c) Pressure Drop across unit. - 1.0kg / sq.cm
1.1 d) Maximum Test pressure - 7.0kg / sq.cm.
Velocity @ 12 m3/hr/m2 - 1200 dia vessel- FRP
Activated carbon filter of FRP construction with
necessary equipment complete with Frontal piping,
valves, suitable supports formounting, pressure
guage, orifice plate, filtering media, etc..,complete
as per the detailed specification for the efficient
working of system.
a) Maximum working Pressure shall be
b) Back wash duration - 15 minutes.
c) Pressure Drop across unit. - 1.0kg / sq.cm
1.2 d) Maximum Test pressure - 7.0kg / sq.cm.
Velocity @ 12 m3/hr /m2 - 800 dia vessel - FRP
Water softener of FRP construction with
necessary Ancillary equipment complete with
piping, valves, ejector, orifice plate, suitable
support for mounting Pressure gauge, Orifice
plate, salt saturator made of corrosion resistant
material and hardness testing kit etc.,Softener also
include initial charge of indion 220NA resin media
to suite the requirement etc., complete as per
detailed specification for the efficient working of
a) Max. working pressure = 3.5Kg / Sqcm.
b) Maximum Test pressure - 7.0kg / sq.cm.
1.3 FRP vessel 800 mm dia with MPV Nos 1 270,000.00 270,000.00
Electronic dosing system for disinfection by
chlorination & with pre set dosage based on the
quantity of water. The dosing system shall consists
1.4 of electronic dosing pump with positive
displacement type with adjustable stroke length
with frequency. The quoted rate shall also include Nos 1 25,000.00 25,000.00
Centrifugal monoblock pumps for filter feed water
inside the pump room. The cost of control panel to
1.5 be included with 2 Nos DOL starter. The pumps
shall run 415V / 50HZ electric supply etc., Set 1 35,000.00 70,000.00
Inter units connection piping with necessary
flanges, bolts, nuts, neoprene gaskets, welding
1.6 wherever necessary, with necessary control valves,
non return valves etc and with one coat of primer
and two coats of approved enamel paint LS 1 145,000.00 145,000.00
ABSTRACT ESTIMATE FOR ELECTRICAL WORK FOR UP GRADATION OF DISTRICT HEADQUARTER HOSPITAL WITH 100 BEDS, ICU &
TRAUMA CARE FACILITY AT ANGUL DISTRICT, ODISHA.
SL.No. Description of Item OSR Amount in Rs. Non-Shedule ItemAmount in Rs. Total Amount in Rs.
SL.No. Description of Item OSR Amount in Rs. Non-Shedule ItemAmount in Rs. Total Amount in Rs.
i. Electrical , Data Networking & Telephone(IP EPBAX) 23595986.00 5647170.00 29243156.00
iii. Nurse Calling System 958250.00 958250.00
iv. Building Management Systems 8948900.00 8948900.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Item Unit
Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Qnty. Shedule Qnty. Non- Rate For Non- Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item OSR Amount in Rs. Amount in Rs.
A. INTERNAL & EXTERNAL ELECTRICAL WORKS WIH DATA N/W, IP EBAX SYSTEM
A. Circuit Cum Wiring
Wiring for light point/ fan/ exhaust fan point/ call
bell point with 1.5 sqmm FRLS PVC insulated
copper conductor single core cable in surface /
recessed 2 mm thick PVC conduit with modular
switch and earthing the point with 1.5 sqmm FRLS
PVC insulated copper conductor single core cable
including providing modular box with cover of
requisite number of modules including providing
1 cover plates as required.
Single light point controlled by one 6A switch or
a) first light point of group control. Each 1106 622.00 687,932.00
b) Subsequent point of group control Each 660 352.00 232,320.00
Wiring for light point/ fan/ exhaust fan point/ call
bell point with 1.5 sqmm FRLS PVC insulated
copper conductor single core cable in surface /
recessed 2 mm thick PVC conduit with modular
switch and earthing the point with 1.5 sqmm FRLS
PVC insulated copper conductor single core cable
including providing modular box with cover of
requisite number of modules including providing
2 cover plates as required.(Excluding rate of MCB)
Single light point controlled by one 6A MCB or
a) first light point of group control. Each 16 666.00 10,656.00
b) Subsequent point of group control Each 12 354.00 4,248.00
Supplying and fixing two module steeped type
electronic fan regulator with proper modular plate
3 switch box including connections etc. as required. Nos 271 475.00 128,725.00
Supplying and fixing 6 Amp plug with 6 Amp
4 switch (Modular Type) on existing board. Nos 124 405.00 50,220.00
Supplying & fixing suitable size GI Box with
modular plate and cover in front on surface or in
recess, including providing and fixing 3pin 5/6
amps modular socket outlet and 5/6 amps modular
5 switch etc. as required. Nos 271 374.00 101,354.00
Supply, installation, testing & commissioning of 6 /
16 Amp Plug Boards consisting of a 16 Amp clip-
in type modular switch with indicator and a 6/16
Amp clip-in type modular shuttered plug socket
fixed on metallic concealed box including
interconnections and making good the damages
caused complete as required and as per direction
6 of Engineer-in-charge. Nos 244 508.00 123,952.00
Supplying, installation, testing & commissioning of
20 Amp AC starter switch with 25 Amp modular
socket outlet with 25 Amp Plug on surface or in
recess, on 2 Nos two module GI box with plate
etc. complete with direction of Engineer-in-charge.
Starter-Crabtree(cat no-ACT0202504) or
Wiring for circuit/ submain wiring along with earth
wire of following size of FRLS heavy gauge PVC
insulated copper conductor single core cable in
heavy duty PVC conduit laid in surface/ recess as
a) 2X2.5 + 1X2.5 sqmm FRLS Cu wire Mtr 7400 96.00 710,400.00
b) 2X4 + 1X4 sqmm FRLS Cu wire Mtr 5570 121.00 673,970.00
c) 2X6 + 1X6 sqmm FRLS Cu wire Mtr 3250 153.00 497,250.00
d) 4X10 + 2X6 sqmm FRLS Cu wire Mtr 2660 413.00 1,098,580.00
B. Fan & indoor Fixtures
Supply, delivery and fixing of Ceiling fan hook
box made out of 18 swg GI sheet and containing
10 mm dia round ms bar projecting atleast 150mm
on either side & duly bent to accommodate ceiling
fan down rod bolt & having earthing arrangement
9 as per direction of Engineer-in-charge. Each 271 120.00 32,520.00
Supplying, installation, testing and commissioning
following type of light fixtures with dummy box
for surface mounted fixtures only, fans and exhaust
fans with all accessories, as required.(The colour
temprature for fixtures shall be between 3500 deg
K & white in colour as per application) ( Use
10 antibacterial UV Light for blood bank rooms.)
Fully diffused type recessed mounted 2'X2' LED
fitting (3000 Lumen/ 25W) similar to PHILIPS
(CAT No:RC380B LED25S -6500 G4 L60 W60
a) PSU OD) / Equivalent of Crompton/ Wipro. Each 970 4,723.00 4,581,310.00
Fully diffused type recessed mounted 1'X1' LED
fitting (2000 Lumen/ 18W) similar to PHILIPS
(CAT No:RC375 LED 15S 18 WATT CW) /
b) Equivalent of Crompton/ Wipro. Each 70 1,587.00 111,090.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Fully diffused type recessed mounted 6"X6" LED
fitting (1800 Lumen/ 18W) similar to PHILIPS
(CAT No:DN177 LED 15S 18 WATT CW ) /
c) Equivalent of Crompton/ Wipro. Each 62 820.00 50,840.00
Commercial Batten type wall mounted 4' LED
fitting (2200 Lumen/ 20W) similar to PHILIPS
(CAT No:BN021C LED20S PSU CW GR S2) /
d) Equivalent of Crompton/ Wipro. Each 162 1,064.00 172,368.00
Retail Down type LED Light surface fitting (1800
Lumen/ 16 W) similar to PHILIPS (CAT
No:SM251C LED16S- 6500 PSU WH) /
e) Equivalent of Crompton/ Wipro. Each 40 2,226.00 89,040.00
10 watt LED Light surface fitting with batten/angel
Holder similar to PHILIPS (CAT No:Base B22) /
f) Equivalent of Crompton/ Wipro. Each 146 414.00 60,444.00
Endura type 700 Lumen/10W LED Bulkhead wall
fitting PHILIPS (CAT No:WT140W LED7S CW
g) PSU S1 PC)/ Equivalent of Crompto/ Wipro. Each 28 1,237.00 34,636.00
5 mtr Blue/white Cove fitting/strips PHILIPS
(CAT No:31308 led strip - blue/white)/ Equivalent
h) of Crompto/ Wipro. Nos 35 1,866.00 65,310.00
Infrared,Surface Mounted PIR occupancy Sensor
on false ceiling, compatible with the existing LED
fixtures ( as per Crabtree Model No. ST46B /
i) Equivalent of Crompton/ Wipro/ Philips Nos 360 2,865.00 1,031,400.00
Supplying and fixing call bell/ buzzer suitable for
j) single phase,230 V, complete as required. Each 30 151.00 4,530.00
Supplying, installation, testing and commissioning
of ceiling fan (5 star rating) including wiring the
down rod, earthing etc as required (Make :
11 Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells).
Supplying, installation, testing and commissioning
of wall mounted fan (5 star rating) including
earthing etc as required (Make : Bajaj/Usha/
12 Crompton/ Orient/ Khaitan/ Havells).
Supplying, installation, testing and commissioning
of Heavy Duty Exhaust fan (5 star rating) including
louvres, Ceiling Rose & Electric Connection as
required. (Make -Bajaj/Usha/ Crompton/ Orient/
13 Khaitan/ Havells)
C. External Light Fittings
Supplying, installation testing and commissioning
following type of light fixtures with all accessories,
14 as required.
60 Watt Outdoor LED Luminaires Street Light
(6500 lumen) PHILIPS (CAT No:Make: Philips
BRP062 LED 65 CW SLA S1 PSU) / Equivalent
of Crompton/ Wipro connected to 32 MM Dia 800
mm GI bend pipe fixed on Wall or column with GI
a) Clamps & hard ware etc. as required. No 15 7,007.00 105,105.00
Gate Light (Make: Bajaj Spigot for BJMPTI 125
MV LPF CAT No: HPMV 125 W or equivalent of
Philips/ Crompton/ Wipro)along with loose wire
box, connectors with one 10A MCB as required
suitable for operation on 240 Volt AC supply as
35 watt integral flood light with driver inside a
PDC housing Led Light (Philips BVP120 LED 35
CW FG S1 PSU GR) / Equivalent of Crompton/
Wipro)along with CC/bricks pedestal & loose wire
box, connectors 50 MM Dia 4 mtr Height GI
Tubular Pole with one 6A MCB for loop in loop
c) out type as required. No 22 10,898.00 239,756.00
Supplying, installation, testing & commissioning of
LED Aviation light luminaries including required
driver/ control box, protections, above the highest
point of terrace level and making good the same. It
should switch ON automatically as required in
night time & OFF in day time including FRLS
copper control wiring etc. complete in all respect
as required & as approved by the Engineer
Incharge. (Cat . No. Bajaj BGAV 302 LED or
d) equivalent from approved makes/ CLIENT). No 1 13,465.00 13,465.00
D. Panels, MDBs, DBs. MCBs
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Supply, installation, testing and commissioning of
cubicle type sectionalised, front operated top entry
dust and vermin proof M.V.Panel Boards suitable
for operation at 415V, 3 phase, 4 wire, 50Hz
distribution system fabricated out of 2.0 mm thick
CRCA sheet, insulated busbar with heat
shrienkable PVC sleeve, base channel, wiring with
space heater, thermostat and control MCBs shall
be provided for all vertical sections of main LT
Panel, all hinged door shall be earthed through 2.5
sq mm tinned braided, the incoming and outgoing
feeders shall be accommodated in a modular
arrangement, detachable gland plates, adequate
size cable alley, Sign writing, Painting, Earthing,
Numbering, Danger plate, including PVC insulated
copper FRLS wires of minimum 1.5 sq.mm & 2.5
sq.mm for CT's etc. with all accessories including
interconnections, earth bus, Surge protection
Device(SPD) etc. as required.(All the incomers of
the panel must be mounting with RS 485
communication port for BMS Compartibility)
LT PANEL(To be installed in Electrical Panel
15 Room) Zone-(Z1&Z2)
Busbar -1600 Amp Al busbar with SC rating of 50
KA suitable for operation at 415 Volt, 50 Hz, 3
One (1)-Incomer feeders from Raw+DG Supply
Panel is consisting of
One (1) - 415V, 1250 A, 50KA, TPN, MDO Type
ACB with microprocessor controlled OL/ SC and
EF releases, shunt trip release, auxilliary contacts
and terminals taken out suitable for bustrunking
termination as required.
One(1)- Multifunction digital meter suitable for
three phase four wire system, unbalanced loading
CL 1.0, flush mounting with RS 485
communication port for reading Voltage, Current,
pf. KW, KWH, KVA, KVAr, KVAh,
KVArHr(BMS Compartibilty)
One set - Indicating lamp for ON/OFF/Trip and
Phase indication with control fuse/ MCB.
One(1) set of 1250/5A ,15VA , Cl 1.0, CTs.
One(1) Digital Ammeter with S/S.
One(1) 0-500V Digital Voltmeter with S/S.
Two (2) - Outgoing Feeders (For one HVAC
Panel and One Spare) each comprising of
One (1) - 415V, 800 A, 50KA, TPN, MDO Type
ACB with microprocessor controlled OL/ SC and
EF releases, shunt trip release, auxilliary contacts
and terminals taken out suitable for bustrunking
termination as required.
One(1)- Multifunction digital meter suitable for
three phase four wire system, unbalanced loading
CL 1.0, flush mounting for reading Voltage,
Current, pf. KW, KWH, KVA, KVAr, KVAh,
One set - Indicating lamp for ON/OFF/Trip and
Phase indication with control fuse/ MCB.
One(1) set of 800/5A ,15VA , Cl 1.0, CTs.
One(1) Digital Ammeter with S/S.
One(1) 0-500V Digital Voltmeter with S/S.
Three (3) - Outgoing Feeders (For one Medical
Equipment Panel and Two Spares) each
One (1) - 250A,TPN, 36KA,MCCB
One(1) set of – 250/5A , 15VA , CL 1.0, CT
One (1) - 3 Ph Digital Ammeter.
One Set ON/OFF Indicating lamp with control
fuse/ MCB with required other accesories.
Four(4) - Outgoing Feeders (For one Fire
Fighting Panel, Two nos 60KVA UPS-1&2 I/C
Breakers(NB: the I/C Breakers of both UPS and
Fire Fighting Panel are considered only in Zone-
Z1 LT Panel instead of Zone-Z2 LT Panel ) and
one Spare) each comprising of
One (1) - 160A,TPN, 36KA,MCCB
One(1) set of – 160/5A , 15VA , CL 1.0, CT
One (1) - 3 Ph Digital Ammeter.
One Set ON/OFF Indicating lamp with control
fuse/ MCB with required other accesories.
Five (5) - Outgoing Feeders (For 4 nos Floor
Distribution Panel- GF to 3rd Floor (Z1) (NB:
4nos FDP -1 ,3,5,7 are considered in Z1 LT
Panel as well as FDP 2,4,6, 8 are Considered in
Z2 LT Panel) and one Spare) each comprising
One (1) - 100A,TPN, 36KA,MCCB
One(1) set of – 100/5A , 15VA , CL 1.0, CT
One (1) - 3 Ph Digital Ammeter.
One Set ON/OFF Indicating lamp with control
fuse/ MCB with required other accesories.
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Three (3) - Outgoing Feeders (For One PHE
Panel (NB: Only Considered in ZoneZ1 LT
Panel not in Z2 LT Panel) and Two Spares)
each comprising of
One (1) - 63A,TPN, 36KA,MCCB
One(1) set of – 63/5A , 15VA , CL 1.0, CT
One (1) - 3 Ph Digital Ammeter.
One Set ON/OFF Indicating lamp with control
fuse/ MCB with required other accesories.
Four (4) - Outgoing Feeders (For 3 nos Lift
Panel-1,2&3, and One Spare) each comprising
of (NB: 4,5&6 Lift Panels are considered in
One (1) - 32A,TPN, 36KA,MCCB
One(1) set of – 32/5A , 15VA , CL 1.0, CT
One (1) - 3 Ph Digital Ammeter.
One Set ON/OFF Indicating lamp with control
fuse/ MCB with required other accesories.
Two (2) - Outgoing Feeders (For One External
Lighting Feeder Pillar Panel-1 and One Spare)
each comprising of (NB: External Feeder Pillar
Panel-2 is considered in Zone-Z2 Panel)
One (1) - 32A,TPN, 36KA,MCCB
One(1) set of – 32/5A , 15VA , CL 1.0, CT
One (1) - 3 Ph Digital Ammeter.
One Set ON/OFF Indicating lamp with control
fuse/ MCB with required other accesories.
One (1) 32 Amp TP contactor, over load trip,
Programmable timer for automatic switching ON
and OFF of external lighting, Auto/ Manual
selector switch, Auxilliary Contactor, ON/OFF
push button and indication along with control fuse
etc as required(for feeder Pillar only).
*The Switchboard shall be complete with all
interconnections, risers, internal wiring, labels,
control/circuit fuses etc. complete as required.
Battrey/Battrey charger
Supplying, installing, testing and commissioning of
230 V, Single Phase, 50 HZ, AC operated suitable
capacity (capacity to be decided after selecting the
Makes of Material for switchgears) AH battery
with Battery Charger for DC supply of following
rating with Boost and trickle charging facility and
protection from over charging a DC DB with
required numbers of outgoing DP MCB's plus 2
Nos. of 16 Amp. DP MCB's as spare feeders
complete as required and as per specifications.
PANEL AS ABOVE Set 2 1,405,100.00 2,810,200.00
FLOOR DISTRIBUTION PANEL(FDP) -
One (1) Incomer - 100 Amp, 25 KA, FP MCCB
with 3 Nos Phase indicating lamps with control
fuse/ MCB Digital Voltmeter and Ammeter with
selector switch .(with required other accesories.)
Busbar - 160 Amp Al busbar suitable for
operation at 415 Volt, 50 Hz, 3 Phase Supply.
Five(5) - Outgoing Feeders for (3 nos LDBs &
Two spares) each Comprising of
One (1) -32A TPN 25KA MCCB with required
other accesories.
Seven (7) - Outgoing Feeders for (3 No PDBs, 3
no ACDBs & One spare) each Comprising of
One (1) -63A TPN 25KA MCCB with required
other accesories.
PANEL AS ABOVE Set 8 182,300.00 1,458,400.00
17 UPS PANEL(O/G)
Two (2) nos Incomer- 160 Amp TPN ,25 KA
MCCB with 3 Nos Phase indicating lamps with
control fuse/ MCB Digital Voltmeter and Ammeter
with selector switch with other required
Busbar - 200 Amp,25KA Cu TP2N busbar
suitable for operation at 415 Volt, 50 Hz, 3 Phase
Ten(10) - Outgoing Feeders for (3 Nos of
SubUPS Panel- 1,2,3,4,5,6,7,8, One Server
Rack & One spare) each Comprising of
One (1) - 63 Amp 4P, 10 KA MCB (C-Curve)
Five(5) - Outgoing Feeders for (One Solar
Inverter, One CCTV, One Fire Alarm wih PA
System, One ELV System & One spare ) each
One (1) - 32 Amp DP, 10 KA MCB (C-Curve)
PANEL AS ABOVE Set 1 65,000.00 65,000.00
18 SUB UPS PANEL(Each Floor Wise)
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
One (1) no Incomer- 63 Amp FP ,10 KA MCB
with 3 Nos Phase indicating lamps with control
fuse/ MCB Digital Voltmeter and Ammeter with
selector switch with required other accesories.
Busbar - 100 Amp,10KA Cu TP2N busbar
suitable for operation at 415 Volt, 50 Hz, 3 Phase
Four(4) - Outgoing Feeders for (3 Nos of
UPSDB- 1,2,3 & One spare) each Comprising
One (1) - 32 Amp 4P, 10 KA MCB (C-Curve)
Three(3) - Outgoing Feeders for (Two nos DP
DB for Medical instruments & One spare) each
One (1) - 32 Amp DP, 10 KA MCB (C-Curve)
PANEL AS ABOVE Set 8 40,600.00 324,800.00
19 UPS Incomer -1&2
One (1) no 160 Amp TPN ,36 KA MCCB with
required other accessories & suitable metal
enclosure concealed in wall for power supply to
20 Feeder Pillar for External Lights
Supplying installation testing commissioning if
double door feeder pillar fabricated out of 2 mm
thick CRCA sheet duly painted, 200 Amp Al
busbar with neutral bus rincluding cc/ brick
foundation as required including following internal
1 No - 32 Amp TPN MCB Incomer (C-Curve)
4 Nos - 16 Amp SP MCB Outgoing (C-Curve)
1 No - 16 Amp SP MCB with 6/16 Amp socket
outlet with 10 Amp modular switch and 1 No-
Bracket Holder with 6 Amp Modular switch. Set 2 22,000.00 44,000.00
Supplying and fixing following way, horizontal
type three pole and neutral, sheet steel, MCB
distribution board, 415 V, on surface/ recess,
complete with tinned copper bus bar, neutral bus
bar, earth bar, din bar, interconnections, powder
painted including earthing etc. as required. (But
without MCB/RCCB/Isolator). (For all Floors
21 LDBs, PDBs, ACDBs & UDBs)
a) 6 way, Double door(4+18) Each 96 3,693.00 354,528.00
Supplying and fixing following way, single pole
and neutral,sheet steel, MCB distribution board,
240 V, on surface/ recess, complete with tinned
copper bus bar, neutral bus bar, earth bar, din bar,
interconnections, powder painted including
earthing etc. as required. (But without
22 MCB/RCCB/Isolator)
a) 6 way, Double door Each 8 1,661.00 13,288.00
Supplying and fixing following rating MCBs/
Isolator in the existing MCB DB complete with
connections,testing and commissioning etc. as
a) 63 Amps, FP 10 KA MCB (C-Curve) Each 48 2,042.00 98,016.00
b) 32 Amps, FP 10 KA MCB (C-Curve) Each 48 1,461.00 70,128.00
c) 32 Amps, DP 10 KA MCB (C-Curve) Each 8 704.00 5,632.00
d) 6 Amp to 32 Amp, 10 KA SP MCB (C-Curve) Each 1776 278.00 493,728.00
D. Cables, Cable Laying & Termination
Supplying & Testing of 1.1 KV grade Aluminium
XLPE power cable of following size suitable for
24 415 Volt, 3Ph, 50 c/s supply.
Supplying & Testing of 1.1 KV grade Cu XLPE
Un Armoured(Flexible) power cable of following
25 size suitable for 415 Volt, 3Ph, 50 c/s supply.
Laying of one number PVC insulated and PVC
sheathed/XLPE power cable of 1.1KV grade of
following size direct in ground including
excavation (75 cm),sand cushioning,protective
26 covering and refilling the trench etc as required.
b) Above 35 sq. mm and upto 95 sq. mm Mtr 40 338.00 13,520.00
c) Above 95 sq. mm and upto 185 sq. mm Mtr 20 352.00 7,040.00
d) Above 185 sq. mm and upto 400 sq. mm Mtr 220 396.00 87,120.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Laying of One No. PVC insulated and PVC
sheathed/XLPE power cable of 1.1 KV grade of
following size in the existing
RCC/HUME/MASONERY TRENCH/HDPE
Pipe/Metal Pipe/On Wall Surface(Clamped with
saddle/PVC & UPVC Pipe)/ CableTray as
b) Above 35 sq. mm and upto 95 sq. mm Mtr 600 104.00 62,400.00
c) Above 95 sq. mm and upto 185 sq. mm Mtr 40 122.00 4,880.00
d) Above 185 sq. mm and upto 400 sq. mm Mtr 466 182.00 84,812.00
28 TERMINATION OF CABLES
Supply & Making end Termination with brass
compression gland and Cu/aluminium lugs for
PVC insulated and PVC sheathed cable of 1.1 kv
grade (without cost of Cable)
Supply & making of Sigle Compression cable
glands and crimping type Cu. cable lugs with
required tools and equipments as per IS. The
29 glands and lugs shall be suitable for 2XY cables.
Providing,fixing and laying of fallowing dia HDPE
pipe (medium class) in ground complete with
fitting incl. trenching(75 mm depth)and refilling as
per direction of Engg.-in-Charge. Ncessary test
report & Warrnaty certificate to be submitted to
the department for genuinity of product & to avail
free after sales service within warranty period for
30 acceptance of materials.
a) 50 mm dia (for Gate crossing) Mtr 25 324.00 8,100.00
b) 200 mm dia (for Road crossing) Mtr 100 828.00 82,800.00
Supply, fabricating and installing following size of
hot dip G.I. perforated type cables trays including
suspending from ceiling with angle, rods
connection pieces, horizontal vertical bends,
reducers, tees, cross members,G.I. nut bolts, G.I.
washers, fasteners etc. complete as required per
specifications & approved by the Engineer
a) 150 mm (W) X 50 mm depth X 1.6 mm thickness Mtr 520 273.00 141,960.00
450 mm width X 50 mm depth X 1.6 mm
Supply, Installation, Testing & Comissioning of
Hipulse U, Fully digital, twin DSP controlled 2X60
Kva (make: APC, Emersion, Riello or equivalent)
IGBT based True On- line double conversion
Technology Smart UPS System with(3-Ph In & 3-
Ph out) VRLA Sealed maintenance free battery
with independent 12V units cell banks of capacity
designed for end cell 12V/150 AH X 34 nos each
UPS for 30 Min Back Up with One Paralleling Kit
, inbuilt isolation transformer, Rack, IRIT &
32 Interlink Cable included. Each 1 2,304,121.00 2,304,121.00
F. Lightning Protection System (Arrestor)
Providing and fixing of lightning conductor finial,
made of 25mm dia 300 mm long, Copper tube,
having single prong at top, with 85 mm dia 6 mm
thick copper base plate including holes etc. Along
33 with Test junction complete as required. Each 46 7,400.00 340,400.00
Supply & Fixing of Copper plate Earthing
(600x600x3mm thick) including accessories, and
providing masnory enclosure with cover plate
having locking arrangement and watering pipe of
2.7 meter long etc. with charcoal/coke and salt as
Providing and fixing 25 mm X 5 mm copper strip
in 40 mm dia GI pipe from earth electrode
including connection with brass nut, bolt, spring,
35 washer excavation and refilling etc. as required. Mtr 180 1,224.00 220,320.00
Providing and fixing 25 mm X 5 mm dia copper
strip on wall/surface or in recess for connection
Providing and fixing 4.0 mm dia cu wire on
37 surface or in recess for loop earthing as required. Mtr 2360 128.00 302,080.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Data Net Working, Telephone(IP EPBAX) &
SITC of dual port, 3X3 , 86x86 mm Square
faceplate with dust cover, snap in frame, white for
I/O fixing at user side with wall mount box for
Data and Voice and Cat 6 I/O UTP SL series
Jackwith Strain relief and bend limiting boot,
Exceed TIA/EIA-568-C.2 and ISO/IEC 11801
standards for Category 6/Class E component
performance. (complete set)
38 Panduit/Corning/Commscope No 210 515.00 108,150.00
SITC of U/UTP Cat 6 Patch cord. Should confirm
or exceed the ANSI/TIA 568 C.2 standards for
CAT 6, 24 AWG Factory terminated RJ 45 plugs
at both ends, Option for colour – Grey, Blue, Red
& Green . Patch cord material should be LSZH
IEC 60332-1, ETL certified. Compliant to IEC
60603-7 and UL 1863. Patch cord should support
retro-fit patch lock & key mechanism for secured
39 connections, 1 Mtr (Panduit/Corning/Commscope) No 210 195.00 40,950.00
SITC of U/UTP Cat 6 Patch cord. Should confirm
or exceed the ANSI/TIA 568 C.2 standards for
CAT 6, 24 AWG Factory terminated RJ 45 plugs
at both ends, Option for colour – Grey, Blue, Red
& Green . Patch cord material should be LSZH
IEC 60332-1, ETL certified. Compliant to IEC
60603-7 and UL 1863. Patch cord should support
retro-fit patch lock & key mechanism for secured
40 connections, 2 Mtr (Panduit/Corning/Commscope) No 210 225.00 47,250.00
SITC of 4 pair U/UTP CAT 6 23 AWG cable ETL
verified to ANSI/TIA 568.2-D and ISO/IEC
11801, Shall meet IEEE 802.3bt (type 4) for
4PPoE transmission, Certified by independent test
lab i.e ETL / Intertek for 4 connector channel
performance tested upto 600Mhz, LSZH sheath as
per IEC 60332-3, max DC resistance 7.61
Ohm/100m to be installed in the existing surface/
recessed steel/ PVC conduit/raceway as required
41 (Panduit/Corning/Commscope) Box 50 8,500.00 425,000.00
SITC of 19", 1U height Category 6 U/UTP Loaded
Patch Panel, 24 port, UL listed. The information
Outlets shall be individually replaceable from the
panel ports. each port should have strain relief
bend protective boots for secured termination.
Metallic high strength with rear cable manager. UL
94V0 rated material.
42 (Panduit/Corning/Commscope) No 13 5,500.00 71,500.00
SITC of 6-core Outside Plant Cable - Corrugated
Steel tape Armored, 2.0mm HDPE Sheath, Loose-
tube, Gel-filled, 9/125 SM, OS2 with attenuation
and 0.31dB/Km @1386nm, confirming to
Telcordia GR-20-CORE. Shall have peripheral
glass yarns strength member with max crush
resistance upto 3000N
43 (Panduit/Corning/Commscope) Mtr. 1000 55.00 55,000.00
SITC of 12-fiber SC-Style, Singlemode , 19-inch,
1U Rack mount Patch Panel pre loaded and factory
assembled with SC SM adapter, 24 SC SM OS2
Pigtails, Splice tray, management rings & Splice
protectors. Shall have min depth of 320mm and
pre-fitted with grounding lugs for installing
metallic armored cables.
44 (Panduit/Corning/Commscope) Nos. 4 13,500.00 54,000.00
SITC of SC-LC Style Singlemode OS2 Duplex
Bend Insensitive Patch Cord, LSZH Sheath
conforming to flame test IEC 60332-3, IEC 60754-
2, IEC 61034-2, UL 1685, 3 Meter, fiber
confirming to G.652.D, G.657.A1. End face shall
of UPC polish, Return loss min 50dB.
45 (Panduit/Corning/Commscope) Nos 12 1,500.00 18,000.00
46 Supply & Installation of SFP Module make Cisco Nos. 10 12,000.00 120,000.00
Supply and Installation of 12U Wall Mount rack
including 1no 6skt PDU, 1no 90CFM FAN, 1no
Cable Manager. (Make-VALRACK,
47 VEROPRESIDENT, Netrack) No 3 8,500.00 25,500.00
Supply and Installation of 42U Wall Mount rack
including 1no 6skt PDU, 1no 90CFM FAN, 1no
Cable Manager. (Make-VALRACK,
48 VEROPRESIDENT, Netrack) No 1 58,000.00 58,000.00
Supply & Installation of 24 Port 10/100/1000Mbps
L2 Managed Switch with 4 SFP Ports. Make:
49 Cisco/Juniper/HP Nos 10 75,000.00 750,000.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
SITC of 4 pair U/UTP CAT 6 23 AWG cable ETL
verified to ANSI/TIA 568.2-D and ISO/IEC
11801, Shall meet IEEE 802.3bt (type 4) for
4PPoE transmission, Certified by independent test
lab i.e ETL / Intertek for 4 connector channel
performance tested upto 600Mhz, LSZH sheath as
per IEC 60332-3, max DC resistance 7.61
Ohm/100m to be installed in the existing surface/
recessed steel/ PVC conduit/raceway as required
50 (Panduit/Corning/Commscope) Box 10 8,500.00 85,000.00
Supply & Installation of Pure IP PBX System
Model - ETERNITY GENX 12SAC 200
subscribers 200Analog lines , 64 party video
conference , voip channel 64, PRI/ISDN channels -
4, IP subscribers 999, analog line expandable upto-
240, arm processor. Make -
51 matrix/accord/asttecs/syntel Nos 1 425,000.00 425,000.00
Supply & Installation of IP based PoE Phone with
single lie Display
with 2 Ethernet Port.
52 Make: Matrix/Panasonic/Asttecs Nos 30 4,000.00 120,000.00
SITC of 19", 1U height Category 6 U/UTP Loaded
Patch Panel, 24 port, UL listed. The information
Outlets shall be individually replaceable from the
panel ports. each port should have strain relief
bend protective boots for secured termination.
Metallic high strength with rear cable manager. UL
94V0 rated material.
53 (Panduit/Corning/Commscope) Nos 2 5,500.00 11,000.00
Supply & Laying of 2pair Telephone Cable make
54 Finolex/ Polycabs/Havells Mtr. 12000 30.00 360,000.00
Supply & Installation of 24 Port 10/100/100mbps
L2 Managed PoE Switch having PoE Power
Budget upto 280W with 4 Gigabite SFP Ports.
55 Make: Cisco/Juniper/HP Nos 2 70,000.00 140,000.00
Supply & Installation of Color ID Telephone set
56 make Panasonic /Beetel/BPL Nos 150 1,500.00 225,000.00
Supply, delivery, installation, testing &
commissioning of indoor wall mounted type
100pair telephone distribution box having
following number of junctions made out of 1.6mm
thick CR sheet steel duly primered & painted with
enamel paint having hinged front door, testing
facility having provision for cable / conduit entry
57 complete as per direction of Engineer-in-charge. Nos 4 7,000.00 28,000.00
Supply, delivery, installation, testing &
commissioning of indoor wall mounted type
200pair telephone distribution box having
following number of junctions made out of 1.6mm
thick CR sheet steel duly primered & painted with
enamel paint having hinged front door, testing
facility having provision for cable / conduit entry
58 complete as per direction of Engineer-in-charge. Nos 1 12,000.00 12,000.00
Supply and laying of 2RX 0.5 sqmm 50 pair
Telephone Riser pvc Cable.(Un armoured)(Floor
SITC of dual port, 3X3 , 86x86 mm Square
faceplate with dust cover, snap in frame, white for
I/O fixing at user side with wall mount box for
Data and Voice and Cat 6 I/O UTP SL series
Jackwith Strain relief and bend limiting boot,
Exceed TIA/EIA-568-C.2 and ISO/IEC 11801
standards for Category 6/Class E component
performance. (complete set)
60 Panduit/Corning/Commscope Nos 30 515.00 15,450.00
Supply & Installation of RJ-11 Information Outlet
Supply, delivery, installation & testing of TV outlet
boards containing a clip-in type modular TV
Socket outlet fixed on metallic concealed box
including connections and making good the
damages caused complete as required and as per
62 direction of Engineer-in-charge. Each 68 443.00 30,124.00
Wiring to TV Antenna Socket outlet from junction
box with Coaxial copper conductor TV antenna
cable run inside prelaid conduit complete including
termination, testing etc complete as required and
63 as per direction of Engineer-in-charge. Mtr 2568 96.00 246,528.00
Supply, delivery and laying of following sizes of
2mm thick PVC Conduit concealed in wall/
column/ roof slab of the building alongwith other
accessories and 18 swg GI wire complete for
Electrical Wiring/Telephone / TV & Data cable
wiring as required and as per direction of Engineer-
J. Miscllaneous Items
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Supplying and fixing 3 nos GI fire bucket of 9 ltr
capacity with suitable pedastal arrangement for sub-
65 station yard etc as reqd. Set 1 5,600.00 5,600.00
66 Supplying 11 kV hand gloves as reqd. Set 1 1,150.00 1,150.00
Supplying and Laying Rubber mat 1M X 2M X
2.0MM thick to withstand 1.1 KV dielectric
strength, Electrical Safety/Shock Chart & SLD etc
Supplying & fixing Route Markers for LT UG
Providing and fixing LT danger notice plate of 200
mm X 150 mm, made of mild steel, at least 2 mm
thick, and vitreous enameled white on both sides,
and with inscription in single red colour on front
69 side as required. Each 2 187.00 374.00
Supplying of First aid box as approved by St.John
Ambulance Brigade/Indian Red Cross Society and
70 confirming to IS 2217/ 1963. Each 4 410.00 1,640.00
S/F of Shock Treatment chart duly glazed mounted
71 on Aluminum Frame with sheet glass as required. Each 8 510.00 4,080.00
Providing & fixing of M.S. angle iron with fixing
materials and painting for cable racks in trenches/
72 on walls etc .as required. Kg 200 80.00 16,000.00
S/F of Shock treatment/ restoration charts written
in Hindi/ local lenguage and English duly framed
73 and covered with 3.0 mm glass as required. Each 8 350.00 2,800.00
Supplying of Caution Boards manufactured out of
16 SWG, MS sheet of 450mmx 300mm size duly
painted white and having `MAN ON LINE' and
'DO NOT SWITCH ON' written in Red complete
with hanging arrangement as required and &
74 approved by the Engineer Incharge. Each 1 140.00 140.00
Supply,installation,testing & commissioning of
poly crystalline solar pv panel of 10KWp
(Make:Waaree / Vikram /Tata-BP) along with
inverter of suitable capacity (Make: Delta/
Schneider (APC)/ ABB) and meeting following
condition/requirement. The efficiency of the panel
1 shall not be less than 16%.
a)Minimum capacity of solar panel shall be 250Wp
b)The solar panel frame shall made of aluminium
c)The support shall be made of GI
d)The top cover of solar panel shall be with 6mm
thick tonghend glass
e)Transformerless inverter with dual MPP trackers
f)Array junction box shall be suitable for PV
array(Make:Hykon/Hensel)
g)Laying of 1.1KV grade XLPE copper conductor
armoured power cable with GI perforated cable
tray suitable for connection from solar pv panel to
inverter (Distance from solar array installation to
inverter may be taken as 20 mtr)
h)One number energy meter installed for showing
all electrical parameter LS 1 1,011,000.00 1,011,000.00
Solar Panel (To be installed inside the
2 Electrical Room at Ground Floor)
Busbar - 100 Amp Al busbar with SC rating of 25
KA suitable for operation at 415 Volt, 50 Hz, 3
One (1) Incomers from Solar Inverter is
One (1) - 63A FP, 25KA,MCCB
One(1) set of – 63/5A , 10VA , CL 1.0, CT
One (1) - 3 Ph Digital Ammeter.
One Set ON/OFF Indicating lamp with control
Eight (8) - Outgoing Feeders
One (1) - 16A DP, 10KA MCB
One (1) - Outgoing Feeder each comprising of
One (1)- 32 Amp FP 10 KA MCB with 32 Amp
TP contactor, over load trip, Programmable timer
for automatic switching ON and OFF of external
lighting, Auto/ Manual selector switch, Auxilliary
Contactor, ON/OFF push button and indication
along with control fuse etc as required.
PANEL AS ABOVE Set 1 48,300.00 48,300.00
C. NURSE CALLING SYSTEM
SITC of Central Display Module -Nurse station
unit Narrating Type of call, Colour Coded Room
nos, Call Forwarding, Call Escalation, SMS facility-
1 up to 16 beds including monitor. Make- Orlia No. 11.000 45800.00 503800.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
SITC of Central Display Module -Nurse station
unit Narrating Type of call, Colour Coded Room
nos, Call Forwarding, Call Escalation, SMS facility-
2 up to 32 beds including monitor. Make- Orlia No. 1.000 61000.00 61000.00
SITC of Bed Unit with Nurse Call, Code Blue and
Additional Help complete with corded handset,
with CLEAR ( more than One BED) Bedside
Nurse Call Modules-3 Modular Face plate. Make-
SITC of Bathroom (Emergency) Pull Cord
Modules Calling Unit – Shared/single Toilet for
Multiple beds (Toilet Call Modules-3 Modular
4 Face plate) Make- Orlia No. 30.000 4000.00 120000.00
5 SITC of Door/ Bed Indicator (DI/BI) Make- Orlia 14.000 2025.00 28350.00
6 SITC of NCS PoE 08 port Switchers Make- Orlia No. 6.000 12250.00 73500.00
7 SITC of NCS PoE 16 port Switchers. Make- Orlia No. 6.000 20000.00 120000.00
Supply of CAT 6 Cable & pulling the Cable with
8 existing PVC Pipe. Make- D-Link Box 6.000 8600.00 51600.00
Supply of Modular Box with Fixing. Make-
TOTAL 958250.00
D. BUILDING MANAGEMENT SYSTEM
SERVER , WORKSTATION HARDWARE
1 S&I of MAIN BMS DATABASE AND
APPLICATION SERVER HARDWARE
Primary Server - The minimum configuration
shall be Intel® Xeon® X5650 (2.66GHz/6-
core/12MB/95W) Processor 8MB shared L3
cache/8/16GB PC3-10600R-9(RDIMM) System
Interface for Modbus RS485 or M-bus Data
point)- Colour Graphics BMS Software Operating
on Windows platform with data for Integration
captured in an ODBC format preferably Excel
Sheet for Monthly computation of Data and as
required by the End User. (Refer I/O summary):
Software capability to do Graphics, trends,
alarms(Option - SMS and E mail), history etc.
Management module with interface to RFID
scanners shall be available. Hard Disk - RAID
configured 7.2 RPM, 1TB for DB storage Hard
Disk -2 x 180GB SAS 10K Drive (Dual mirrored)
RAID 1 configured drives for OS and Application
Software Integrated Dual Port Gigabit Server
Adapter/HP Smart Array P411/256 BBWC (2) x Nos 1.000 245500.00 245500.00
460W common slot Power Supply SATA DVD
Optical Kit 3 PCI-E x8 Kit and complete as
required and as per specifications with necessary
Rack and Accessories.
2 BMS Client Station
S&I of BMS Client workstation shall comprise
of the following minimum hardware:
Six Core Processor at min. 3.2 GHz ,12M, Intel
HD Graphic 630, 6.4GT/s, 8 GB or more of
RAM, 500GB SSD, 3.0Gb/s Hard Drive for OS
and BMS Applications Network Copper Interface
Card - 10/100/1000MB Video Card – 8 GB Quad Nos 1.000 115500.00 115500.00
Monitor Graphics card
Microsoft® Windows 10 or Higher 64 bit which
offers teaming feature and complatible with BMS
Software. Complete with Anti-Virus, MS
Windows Client Software and operating license;
3 S&I of A 4 size Laserjet colour Printer suitable for
the application, with driver software.
4 SITC of Edge Switch : 8 port layer 2 Industrial
switch with 10/100/1000 non-POE, Managed
Switch with two SFP slots and all related
termination accessories as per site specific system
requirement with 2nos.Shall be with DIN Rail
Mounted 230V Dual AC Input (Primary & Nos 5.000 56000.00 280000.00
Secoundry power Source) Intelligent Power
Supply with output of 48V DC complete with
Enclosure. SFP Modules shall be considered as
5 S&I of Networking Accessories Lot 5.000 131000.00 655000.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
6 S&I of GUI software for the proposed Building
Management System shall be point license based
having BACnet Advanced Workstation (B-AWS)
certification having BACnet protocol version 13.
The software shall comply to vector graphics. The
software shall support distribution of the system
over multiple servers to cater to future
expandability. The servers shall be able to inter-
connect with each other so that a user can
seamlessly navigate the objects in the system
independently of the server he/she is connected to.
The software shall be capable of integration with Set 1.000 1291000.00 1291000.00
different BACnet data e.g. BACnet over IP or
LON or MSTP vide converters manufactured by
same OEM. The software shall be capable to
support different distributed system configurations
e.g. SEGMENTED, FULLY MESHED and
HIERARCHICAL so that very large systems can
be connected and systems can be easily organized
by location or discipline. The software shall also
support historic database infrastructure to be
configured over multiple on-line store of set of
data slices of congigurable sizes and durations.
This shall allow Storage that can be optimally
tuned for different recording frequencies, Storage
can be segregated by discipline/scope to cover
specific requirements, Seamless access to data:
reporting, advanced reporting and log viewer
searches work across storages, Data archiving
supported, provides a less expensive solution when
long term on-line data availability is not required.
should include 10000 IO points (Including Hard &
Soft Points) as per IO summary.
-With 2 simultaneous client Station Lisences.
-SMS & E-mail Alarm Notification Module , SMS
Paging & Email Facility for transmitting specified
alarms to designated personnel.
-Shall be Complete with Web Browser Module
for Remote Login, to be able to transmit user
defined data in Graphical Format. The Client
should be capable to interface seamlessly with both
the Application Servers and there should not be
any loss of processing / visualisation, even if one of
the Application Server Hardware Fails.
7 S&I of Third Party Integration:The Protocol
Integrator/ Convertor shall be Capable to Integrate
Open protocol systems on BACnet
/Modbus/LONWORKS/M-Bus/J-Bus Protocol
Made avaliable on IP, or on serial RS 485 / 232
interface.( Separate Integrator for each
system)inetration licenses and interface port for
following third party systems.
a Integrator for VRF Units Set 1.000 301125.00 301125.00
b Integrator for Lifts Set 1.000 17125.00 17125.00
c Integrator for Un-Interupted Power Supply System Set
d Integrator for SMPS /Battery Set 1.000 17125.00 17125.00
e Integrator for Breakers Set 1.000 60125.00 60125.00
f Integrator for Diesel Generator (DG) System Set 1.000 30825.00 30825.00
g Fire Alarm System Integration Set 1.000 97125.00 97125.00
h Integrator for Energy meters Set 1.000 107125.00 107125.00
8 Direct Digital Controllers: BACnet/IP
S&I of Networkable 32 Bit DDC Controllers with
I/O points as per enclosed IO List, inbuilt real time
clock, Battery backup. The controllers shall be
capable of standalone operation with real time
clock and historical database. The DDC's shall be
capable of peer to peer communication without
help of system interface controller or PC. The
DDCs shall be with suitable IP 54 enclosure
complete with all wiring and accessories . BTL
a Underground Fire Tanks Lot 1.000 155000.00 155000.00
b Raw Water Tanks Lot 1.000 26800.00 26800.00
c Flushing Water Tanks Set 1.000 26800.00 26800.00
d Soft Water Tanks Set 1.000 26800.00 26800.00
e RO Water Tanks Set 1.000 26800.00 26800.00
f Overhead Fire Water Tanks Set 1.000 26800.00 26800.00
g Overhead Domestic Water Tanks Set 1.000 26800.00 26800.00
h Number of Sumps Set 1.000 26800.00 26800.00
j Electrical Pump System Set 2.000 26800.00 53600.00
k Diesel Operated Pump System Set 1.000 26800.00 26800.00
l Jockey Pump System Set 2.000 26800.00 53600.00
m Booster Pump System Set 1.000 26800.00 26800.00
n Electrical Panels Set 1.000 121800.00 121800.00
o Number of Toilet Exhaust Fans Set 360.000 2200.00 792000.00
p Number of Smoke Extraction fans Set 48.000 5600.00 268800.00
q Number of Kitchen Exhaust fans Set 40.000 5600.00 224000.00
r Number of Liftwell Pressurization fans Set 6.000 5600.00 33600.00
s Number of Staircase Pressurization fans Set 12.000 5600.00 67200.00
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
9 S&I of Portable Operator Terminal (POT)/
terminal server capable to be hooked to any
Automation level controller to monitor and change
set points of any parameter and communicate to Nos 1.000 92125.00 92125.00
any controller in the network. The Terminal should
be capable of viewing / changing parameters and
trend the specified parameters as per requirement
10 SITC of Field Sensors
a Outside Air Temperature & RH monitoring Nos. 1.000 19750.00 19750.00
b Hydroge Sensor Nos. 1.000 23750.00 23750.00
c Air quality sensors/Co2 sensor Nos. 40.000 13250.00 530000.00
d Wall/Ceiling mount Temerature and RH sensor Nos. 24.000 10750.00 258000.00
e Wall mount Temerature sensor Nos. 24.000 1850.00 44400.00
f Flame proof Level Switch For Disel Tank Nos. 2.000 6250.00 12500.00
11 Cable and Conduit
SLTC of Cabling for instrument, controls, valves
to DDCs and communication cabling from DDC to
central equipment complete with earthing,
supports etc complete. Laid on Surface / On Cable
Trays. All Cables shall be ferruled and tagged, and
shall use lugs for termination at both ends.
a Supplying & Installation of signal FRLSH cables 4
core 1.0 Sq.mm Armoured Shielded Cable
b Supplying & Installation of signal FRLSH cables 2
core 1.0 Sq.mm Armoured Shielded Cable
c Supplying, laying, termination, testing and
commissioning of Cat 5/Cat 6 Unarmoured cable Mtrs 2000.000 59.00 118000.00
for bus connection- for Integration / controllers
d PVC 25mm FRLSH conduit Mtrs 2000.000 70.00 140000.00
S/F of Pre-Galvanised Perforated G.I Cable Trays
without cover with all required fixing & mounting
accessories of the following sizes
13 EQUIPMENT RACK
S/F of 19" type Equipment racks for mounting the
Servers/ Switches in the BMS Equipment Room,
& for mounting field mounted Switches at every
Floor.Racks shall be complete with Modular Patch
Panels for Patching the Field Cables.
ABSTRACT ESTIMATE OF FIRE FIGHTING, FIRE ALARM & PUBLIC ADDRESSING SYSTEM FOR UP GRADATION OF DISTRICT
HEADQUARTER HOSPITAL WITH 100 BEDS, ICU & TRAUMA CARE FACILITY AT ANGUL DISTRICT, ODISHA.
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
A. FIRE FIGHTING, FIRE ALARM & PUBLIC ADDRESSING SYSTEM
PART - I : FIRE FIGHTING PUMPS, PIPING,
VALVE & ACCESSORIES :
Electric Motor Driven Hydrant Pump Location -
Supplying, installing, testing and commissioning of
Fire authority approved Electrical driven fire pump
suitable for automatic/ manual operation consisting
of the following:
i) Horizontal split casing, high pressure, single/
multistage centrifugal type fire pump having cast
iron body, bronze impeller,stainless steel shaft &
capable of delivering 2280 LPM against a total
head of 56 M while running at 2955 RPM
complete with proper connection to suction and
delivery line, and including bypass arrangement for
testing of pumps as per the requirement. Suitable
mechanical seal with mounting aggangement shall
be included, having a name plate indicating
suction, delivery, head, discharge, stages, RPM
and direction of rotation.
Pump shall be capable of furnishing not less than
150% of rated capacity at a head not less than 65%
of rated head. The shut off head shall not exceed
120% of rated head.
ii) Squirrel cage, induction motor, TEFC type
suitable for 415 + 10%V, 3 phase, 50 Hz, AC
supply, of suitable HP rating for the above pump
with synchronous speed of 2955 RPM conforming
to IP55 protection & class 'F' insulation. The
motor shall conform to IS 325 1978(up to date)
with flexible coupling and coupling guard .
iii) Common base plate for mounting pump and
motor fabricated of mild steel channel as per
manufacturer's recommendation with heavy duty
Anti Vibration pads (4 Nos., heavy duty).
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
iv) Suitable reinforced cement concrete pump
foundation as per manufacturer's design including
foundation bolts, washers as required.
v) Flexible Coupling and coupling guard for direct
coupling of pump and motor.
vi) Drain Pipe with Valve (40 MM Dia)
Main Fire Hydran Pump
Discharge : 2280 LPM
Pumping Head : 56 M
vii) Rate should included interconnection cables,
foundation and foundation bolts.
Diesel operated Fire Pump for Hydrant System
Location - Pump Room :
Supplying, installing, testing & commissioning of
fire authority approved Diesel Engine driven fire
pump suitable for automatic/manual operations
consisting of the following :
i) Horizontal split casing, high pressure single/
multistage centrifugal type fire pump having cast
iron body, bronze impeller,stainless steel shaft &
capable of delivering 2280 LPM against a total
head of 56 M while running at 2200 RPM
complete with proper connection to suction and
delivery line, and including bypass arrangement for
testing of pumps as per the requirement.
Mechanical seal shall be included, having a name
plate indicating suction, delivery, head, discharge,
stages, RPM and direction of rotation.
Pump shall be capable of furnishing not less than
150% of rated capacity at a head not less than 65%
of the rated head. The shut off head shall not
exceed 120% of rated head.
ii) Water cooled heat exchanger type diesel engine
of required BHP or as per manufacturer at 2200
RPM for the above pump complete with standard
accessories & suitable cooling system as described
in specifications.
iii) Common base plate for mounting pump &
engine of required strength manufactured out of
M.S. channels as per manufacture's
recommendation with heavy duty Anti Vibration
pads. (Cushy foot) (6 nos., heavy duty).
iv) Flexible Coupling & coupling guard for direct
coupling of engine & pump.
v) Suitable reinforced cement concrete pump
foundations as per manufacturer design including
foundation bolts, washer as required.
vi) 1 No. 200 Lits capacity day oil storage tank
fabricated from 4 mm thick M.S. sheet. Tank shall
be provided with inlet, outlet, overflow, vent drain
connections, manhole cover (300 mm I.D.) &
level indicators. Tank shall be mounted on 2 m
high steel structural supports with access ladder
(Painted with 2 coats of red oxide paint). Tank
shall be provided with epoxy coat from inside and
one coat of red oxide & two or more coats of
synthetic enamel paint of approved colour on out
vii) 24 volts 180 AH lead acid battery (12 volts - 2
Nos) with boost/Trickle charger for starting the
engine automatically complete as required.
Diesel Engine driven pump of:
Discharge : 2280 LPM
Pumping Head : 56 M
viii) Rate should include inter connecting cables,
foundation & foundation bolts.
Electrical Motor Driven Jockey Pump Location -
Supplying, installing, testing & commissioning of
fire authority approved electrically driven Jockey
pump suitable for automatic/manual operation
consisting of the following:
i) Horizontal / Vertical mounted multistage jockey
pump having cast iron body, S.S. impeller,
stainless shaft with mechanical seal capable of
delivering 180 LPM against total head of 56 M
while running at 2920 RPM complete. The system
shall be complete with necessary pressure gauge
with gun metal shut off cock on delivery side
including bypass arrangement for testing of
working of the pumping set as required. The pump
should meet the requirement of IS 15105:2002 and
must be approved by the local fire authority.
ii) Squirrel cage induction motor suitable for 415 +
10%V, 3 phase, 50 Hz, AC supply of suitable HP
rating for the above pump with synchronous speed
of 2920 RPM T.E.F.C type connected to pump
with flexible coupling and coupling guard .
iii) Common base plate for mounting pump and
motor fabricated of mild steel channel as per
manufacturer's recommendation with heavy duty 4
Nos. Anti Vibration pads.(Cushy foot)
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
iv) Suitable reinforced cement concrete pump
foundations as per manufacturer's design including
foundation bolts, washers as required.
v) Drain pipe with valve (40 mm dia)
vi) Jockey Pump :-
Discharge : 180 LPM
Pumping Head : 56 M
vii) Rate shall include inter connecting cables,
foundation & foundation bolts.
Electrical Motor Driven Terrace Pump Location -
i) Supplying, installing, testing & commissioning of
fire authority approved electrically driven Terrace
pump suitable for automatic/manual operation
consisting of the following:
ii) Horizontal centrifugal end suction type fire
pump capable of delivering 450 LPM against a
total head of 35 M while running at 2900 r.p.m.
complete with burdon type pressure gauge with
Gun metal cocks/ valves etc. on the delivery side,
including bypass arrangement. Gland arrangement
shall be included.
iii) Squirrel cage, TEFC induction motor suitable
for 415 ± 6%V, 3 phase, 50 Hz A.C. supply of
suitable H.P. for the above pump running at 2900
r.p.m. conforming to IP 55 pralecting and class 'H'
insulation. The motor shall be conform to IS:325-
1978 (upto date)
iv) Common bed plate for mounting pump &
motor of requisite strength manufactured out of
M.S. channel as per manufacturer's
recommendation.
v) Antivibration (Cushy foot) heavy duty mounting
pads as per requirement.
vi) Coupling and coupling guard for direct
coupling of motor and pump.
vii) Terrace Fire Pump
Flow rate : 450 LPM (27.00 m3/hr)
Pumping Head : 35 M
Motor KW : 5.5 KW (Approx) or As per
manufacturer recommendation
Providing, fixing, testing and commissioning of
precharged air vessel (size 450 mm dia & 1500
mm height) fabricated shell from 8 mm thick &
dished end 10 mm thick M.S. Plate for
pressurization of hydrant system complete with
5 adequate pressure switches (as per design / No 1.000 44695.00 48000.00
requirement) with valve to operate as per operating
sequences including 25 mm dia drain valve, air
release valve with ball cock on top, 25 mm dia
inlet with isolating valve duly painted from inside
and out side complete as required.
Providing all materials, labour, T&P for laying of
following dia M.S. heavy class pipes conforming
to IS:1239 with ISI mark & required sizes of fitting
like off set, bend, tee, reducer flange & flange
joints etc. as per site condition including gas
cutting by oxygen and acetelene gas flame, fitting
and setting as per required size wherever
necessary, jointing the pipes by electric welding
confirming to IS specification and electrodes
confirming to IS specification after 'V' grove
cutting. Aligning the pipes inside the trenches
6 including necessary excavation of earth work of
required width & depth in all kinds of soil /rock
and back filling or supporting/fixing the pipe on
floor / wall /ceiling with clamps, hangers (using
anchor fasteners) or angle iron, G.I. pipe sleeve of
suitable higher size shall be provided wherever the
pipes are crossing the walls/floors and sealing the
sleeves with glass wool in between & fire sealent
compound at either end all as per the approved
specification including cutting holes and chases in
brick/RCC wall/roof/chajja and making good the
same to original
All hangers, condition.
clamps, brackets etc. shall be of
galvanized iron unless specified otherwise and then
supply of the same shall also be included. Painting
2 (two) or more coats with synthetic enamel paint
of Post office red shade over a coat of primer for
above ground level & painting 2 (two) or more
coats with anticorrosive epoxy paint for below
ground level. Prior to application of primer the
surface should be cleaned for any dirt, rusts, rough
substance etc. Including painting of legends both
direction arrow as per the approved specification
including testing & commissioning the system.The
cost inclusive of hire and running charges of
welding generator set & all taxes, duties,
transportation, hire & running charges of
machineries, POL, to & fro charges with all
consumables for all floors etc. all complete as per
specification & direction of EIC. Make-
SAIL/JINDAL/TATA
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Providing, fitting & fixing of following size cast
iron double flanged slim seal wafer type Butterfly
valves with EPDM rubber lined with lever
operated as per IS-13095 with ISI mark of
pressure ratting PN-1.60 including fixing the
same with supply of required jointing materials like
rubber insertion, MS nuts & bolts, paint etc. and
testing the joints with required water pressure for
all floors etc. all complete as per specification &
direction of E.I.C. Make-
KIRLOSKAR/IVC/ZOLOTO/KARTAR/HONEY
Providing, fitting & fixing of following size cast
iron double flanged Y type strainer with SS 304
perforated screen confirming to IS 1538 with ISI
mark of pressure rating PN-1.60 including fixing
the same with supply of required jointing materials
8 like rubber insertion, MS nuts & bolts, paint etc.
and testing the joints with required water pressure
& all complete as per specification & direction of
KIRLOSKAR/IVC/ZOLOTO/VENUS/HONEYW
Providing, fixing, testing & commissioning of C.I.
dual plate Non-return valve [PN 1.6 Rating
(10kg/cm2] conforming to IS 778 and test
pressure not less than 15 kg/cm2, complete 2 nos.
9 matching flanges, rubber insertion, with nuts, bolts
and washers etc of following sizes as per the
instruction of EIC . Make-
KIRLOSKAR/IVC/ZOLOTO/KARTAR/HONEY
Providing, fixing, testing & commissioning of M.S.
class 'C' diesel pump exhaust pipe including all
fittings like bends, tee, clamps/structural steel
support of suitable dia for the engine . The pipe
shall be insulated with 100 mm thick mineral wool
insulation wrapped in chicken mesh with clad with
24 gauge aluminium sheet as per the instruction of
EIC. Make-SAIL/JINDAL/TATA
The pressure switches shall be employed for
starting and shutting down operation of pumps
automatically, dictated by line pressure. The
Pressure Switch shall be diaphragm type. The
housing shall be die cast aluminium, with SS 316
movement, pressure element and socket. The set
pressure shall be suitably adjustable as per
instruction of EIC.
Supplying and fixing 2 Way Fire Brigade inlet
63MM dia of CI body with 2 No. Gun Metal male
instantaneous inlet couplings complete with cap
and chain as required. For 100 mm dia M.S. Pipe
connection conforming to lS : 904 as required
With brick platform & duly painted with Post
office red externally and white internally with
synthetic enamel paint cornplete in all respect, for
external hydrant, as required direction of Engineer-
in-charge. (Fire Brigade inlet)
Supply,Installation,Testing & Commissioning of
Pressure gauge of 0-16 Kgf/sq.cm. range with cut-
13 off bronze ball valves below of suitable size with Nos 4.000 498.00 1992.00
all accessories as per direction of Engineer-in-
14 FIRE PUMP ELECTRICAL PANEL (FPP)
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Fabrication, Supplying, Installation, Testing &
Commissioning of Electrical Fire Motor Control
Panel of cubical construction, floor mounted type,
fabricated out of 2mm. thick CRCA sheet,
compartmentalized with hinged lockable doors,
dust and vermin proof, powder coated of approved
shade after 7 tank treatment process, cable alley,
interconnection with solid aluminium strip / single
core PVC insulated FRLS copper conductor cable,
having suitable mountings for switchgears and
accessories and internal control & power wiring
with suitable rating PVC insulated FRLS copper
conductor, earth terminals, numbering etc.
complete in all respects, suitable for operation on
415 V, 3 phase 50 HZ AC supply with enclosure
protection class IP 42 with 800 Amp aluminium
bus bar etc complete as required.
a) MCCB, TPN 160 A, 25ka with adjustable
thermal magnetic release and rotary handle (ICS=
ICU= 25Ka) - 1 set.
b) Digital Ammeter (0 - 160 A), 96 mm. sq. CT
operated with inbuilt selector switch with 3 Nos.
CT's of ratio 160/5 A, 10 VA burden and accuracy
of class 1.0 - 1 Sets
c) Digital Volt Meter (0-500 V) 96 mm. sq. with
inbuilt selector switch and control MCBs - 1 Sets
d) Phase Indicating coloured LED (RYB) with
control MCBs - 1 Sets
Electrolytic high conductivity aluminium three
phase and neutral bus bars rated at 415V, 200
amps, 50Hz, AC, insulated with heat shrinkable
coloured PVC sleeves & clip on shrouds for joints.
Outgoing for Main Fire Pump
a) MCCB TPN, 125 A (with adjustable thermal
magnetic release and (Ics=Icu=25KA), with CT
operated digital Ammeter (0 - 160 A), with 3 CT's
of 125/5 A, 10 VA, ccuracy 1.0, ASS and
coloured LED for on (Red) indication - 2Set (1 W
b) Fully Automatic Star Delta Starter suitable for
fire Pumps motor of minimum 50 HP / (as per the
recommendation of pump manufacturer) complete
with over load protection, current sensing type
single phase preventer complete with contactors,
push button, indicators LED type Auto/manual
selector switches all accessories and FRLS copper
conductor wiring etc. as required - 1 Set
c) MCCB TPN, 40 A, 16 KA with CT operated
digital Ammeter (0 - 40 A), with 3 CT's of 40/5 A,
10 VA, accuracy 1.0, ASS and coloured LED for
on (Red) indication with adjustable thermal
magnetic release - 3 Set(1 spare)
d) Fully Automatic DOL Starter suitable for
Jockey Pumps motor of minimum 5.0 HP / (as per
the recommendation of pump manufacturer)
complete with over load protection, current
sensing type single phase preventer complete with
contactors, push button, indicators LED type
Auto/manual selector switches all accessories and
FRLS copper conductor wiring etc. as required - 2
e) MCCB TPN, 32 A, 16 KA with adjustable
thermal magnetic release - 1 Set
f) MCB 4 Pole, 32/40/63 A, 10 KA 'C' - 2 Set
g) MCB Double Pole, 16/25 A, 10 KA 'C' - 3 sets.
h) MCCB, TPN isolator 40 A, 16ka with
adjustable thermal magnetic release and rotary
handle (ICS= ICU= 16Ka) - 1 set with suitable
mounted in CRCA enclosure of 2mm thick IP-65
rated near terrace pump. (1 Nos.)
Diesel Engine Control
i) Auto / Manual selector switch and 3 attempt
Starting device, Electronic timer, Relays, Auxiliary
switches, Rotary switches, Tripping relays,
Contactors, Push button for manual Start / Stop
etc. to make the equipment automatic as per
functional requirement.
j) Battery charging unit suitable for 24 V DC with
boost and trickle charger, selector switch, with
suitable rating transformer, rectifier, RC filter
network, fuses on AC and DC protection, 0 - 30 V
DC Digital Volt meter, 0 - 20 A DC Digital
Ammeter, the charger should be cut off when the
engine is started and the batteries shall be charged
from battery charging alternator provided in the
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
k) Suitable rating & type standard relays,
contactors and other accessories for automatic
operation of diesel engine
l) Indication LED's for high / low lub, oil pressure,
water temperature, engine on indicator, with
suitable alarms, acknowledgement button etc.
System Controller
m) Designing, Supply, Installation, Testing and
Commissioning of system controller to control
operation of Main Electric Fire Pumps, Diesel
Engine Pump, Jockey Pumps, Terrace Pump in
sequence as per specification consisting of relays,
timers, sensors, annunciation window for fault
indication, complete as per specification.
n) First Jockey pump will start than hydrant start,
in case of failure of power diesel pump will start.
o) Colour coded internal wiring and connections
etc. with suitable size Fire Retardant Low Smoke
PVC insulated copper cable / solid aluminium strip
/ bus bar from incoming to bus bar and from bus
bar to switch gears / MCCB, starters, meters,
selector switches, indicating LED's, interlocking
and sequence operation arrangements.
p) Terminal facility for repeat indicator of various
audio and visual indications.
Fire panel as above Set 1.000 258708.00 258708.00
Supply and installing of following size of
perforated hotdip G.I. cable trays including
horizontal and vertical bends, reducers, tees, cross
members and other accessories as required and
duly suspended from the ceiling with full threaded
GI suspenders, along the wall with supports and
including painting etc. as required & approved by
thye Engineer Incharge.
a) 300 mm width x 40 mm depth x 1.6 mm thickness RM 55.000 621.00 34155.00
b) 150 mm width x 40 mm depth x 1.6 mm thickness RM 25.000 531.00 13275.00
c) 100 mm width x 40 mm depth x 1.6 mm thickness RM 40.000 476.00 19040.00
Supply, laying, connecting, testing &
commissioning of following size of 1.1 kv grade
multicore aluminium/ copper conductor XLPE
insulated PVC sheathed armoured cable as per IS:
7098:1988 (Part-I) with upto date amendments
etc. complete as required. Tagging on both the
ends will be done with aluminium tags etc.
complete as required.(Quantities as per site
requirement shall be finally estimated & executed
accordingly with prior approval.)
3.5 core x 70 sqmm Al. Ar. XLPE Cable (From
LT Panel to Fire Fighting Panel)
3 core x 50 sqmm Al. Ar. XLPE Cable (Fire
Fighting Panel to Main Electric Pump Set)
3 core x 10 sqmm Al. Ar. XLPE Cable (Fire
c) Fighting Panel to Jocky Pump Set & Terrace Pump RM 80.000 381.00 30480.00
3 core x 2.5 Sq mm copper conductor
unarmoured/armoured control cable.
Supplying and making indoor end termination with
brass compression gland (Heavy duty) and suitable
copper / aluminium lugs for following size of
XLPE insulated PVC sheathed copper/ aluminium
conductor armoured/ unarmoured cable of 1.1 KV
grade including cost of ferrules, cable sockets,
insulation tape & other accessories etc. complete
a) 3.5 core x 70 sqmm Al. Lugs Set 2.000 190.00 380.00
b) 3 core x 50 sqmm Al. Lugs Set 2.000 156.00 312.00
c) 3 core x 10 sqmm Al. Lugs Set 4.000 134.00 536.00
d) 3 core x 2.5 Sq mm Copper Lugs Set 6.000 165.00 990.00
Providing and fixing following size of GI strips/ GI
18 wire etc. on surface or in recess for connections,
including GI clamps etc. as required.
Note : Contractor shall include in his rate for
providing level controller, pressure switches,
wiring, cabling from level controller/pressure
switch to panel etc. complete as required to
operate the system automatic/manual. Pump shall
be protected against running dry.
PART - II : WET RISER CUM DOWN COMER
& FIRE HYDRANT SYSTEM (INTERNAL) :
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Providing all materials, labour, T&P for laying of
following dia M.S. heavy class pipes conforming
to IS:1239 with ISI mark & required sizes of fitting
like off set, bend, tee, reducer flange & flange
joints etc. as per site condition including gas
cutting by oxygen and acetelene gas flame, fitting
and setting as per required size wherever
necessary, jointing the pipes by electric welding
confirming to IS specification and electrodes
confirming to IS specification after 'V' grove
cutting. Aligning the pipes inside the trenches
19 including necessary excavation of earth work of
required width & depth in all kinds of soil /rock
and back filling or supporting/fixing the pipe on
floor / wall /ceiling with clamps, hangers (using
anchor fasteners) or angle iron, G.I. pipe sleeve of
suitable higher size shall be provided wherever the
pipes are crossing the walls/floors and sealing the
sleeves with glass wool in between & fire sealent
compound at either end all as per the approved
specification including cutting holes and chases in
brick/RCC wall/roof/chajja and making good the
same to original condition.
All hangers, clamps, brackets etc. shall be of
galvanized iron unless specified otherwise and then
supply of the same shall also be included. Painting
2 (two) or more coats with synthetic enamel paint
of Post office red shade over a coat of primer for
above ground level & painting 2 (two) or more
coats with anticorrosive epoxy paint for below
ground level. Prior to application of primer the
surface should be cleaned for any dirt, rusts, rough
substance etc. Including painting of legends both
direction arrow as per the approved specification
including testing & commissioning the system.The
cost inclusive of hire and running charges of
welding generator set & all taxes, duties,
transportation, hire & running charges of
machineries, POL, to & fro charges with all
consumables for all floors etc. all complete as per
specification & direction of EIC. Make-
SAIL/JINDAL/TATA
Providing, fixing, testing & commissioning of
Stainless steel single headed ISI marked oblique
pattern hydrant landing valves with 80mm dia
flanged inlet & 63 mm dia instantaneous type
female outlet complete with stainless steel cap and
GI chain, twist release type plugh and all
accessories as per IS : 5290 -1993 (Type 'A')
including fixing with anchor fasteners and flanged
tapping from wet riser all complete as per
specification & direction of EIC.
Providing, fixing, testing & commissioning of 15
m/30 m long non-perlocating, rubber reinforced
lined fire hose pipe (as per IS : 636-1979, Type A)
of 63 mm dia and length as described below. The
hose shall be rated for brust pressure of 35.7
Kg/sqcm. Hose shall be complete with ISI marked
SS male & female coupling (IS:903) bound &
rivetted to hose pipe with copper rivets & 1.5 mm
copper wire as per the instruction of EIC. (Internal
Providing, fixing, testing & commissioning of 63
mm dia Instantaneous Pattern (male) Stainless
Steel short size branch pipe with nozzle of 20 mm
nominal bore outlet as per IS:903 : 1993 suitable
to fit with standard instantaneous type 63mm dia
coupling ISI marked (IS:903:1993) complete.
Providing and fixing standard fireman's axe with
23 heavy insulated rubber handle tested for 20 Each 36.000 498.00 17928.00
Supply,Installation,Testing & Commissioning of
Swinging pattern wall fixing first aid hose reel
24 made from MS sheet ,spray painted in Post office Each 36.000 8975.00 323100.00
Red, confirming IS: 884 and moving parts
a) MS fabricated hose reel drum to accommodate
20 mm dia 36 mtr long hose with fixing bracket.
b) 20 mm dia X 30 Mtr long water hose with
ABS(Plastic) shut-off nozzle as per IS: 444/IS:
c) 25 mm dia GM Ball Valve at inlet side of the
hose reel drum as required.
Providing supply & fixing of MS Hose Box for of
suitable size(750X600X250mm) to accomodate 2
25 nos. of 15/ 1 no of 30 mtr long fire hose and a Each 36.000 2622.00 94392.00
branch pipe, wall mounted type as per direction of
Engineer-in-charge.
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Providing & fixing fire authority approved weather
proof M.S. fire hose door (size 900 (L) x 2100
(H)) made out of 16 gauge M.S. sheet Angle frame
capable of accommodating fire hose reel, fire
hydrant, hose pipe, fittings & accessories. The
26 door shall have a single or double glazed front Each 20.000 5000.00 100000.00
glass door (with 4 mm thick glass) with lock & key
arrangement & shall be painted with Fire red as
per IS:5, shade no. 536. Drain arrangement shall
be provided by Contractor. (For Internal Hydrant)
Providing, fitting and fixing of C.I. 25 MM single
air relief valve with stop cock confirming to
IS:14845/2000 with ISI mark for water works
27 purpose including fixing the same with hydrant Each 12.000 792.00 9504.00
riser including testing & commissioning the system
etc. all complete as per approved specification &
direction of Engineer-in-charge.
Supply,Installation,Testing & Commissioning of
Pressure gauge of 0-16 Kgf/sq.cm. range with cut-
28 off bronze ball valves below of suitable size with Each 12.000 498.00 5976.00
all accessories as per direction of Engineer-in-
Providing, fixing, testing & commissioning of ball
valve with SS ball suitable for test pressure of not
29 less than 15 kg / sq.cm of the following size with
nuts, bolts, gaskets, necessary accessories, etc as
III) PART - III: FIRE EXTINGUISHER :
Note : [1] All Fire Extinguisher shall be HCFC,
CFC and Halons free. [2] The Fire Extinguisher
Manufacturer/Supplier shall provide declaration,
Technical Data Sheet/cutsheet of All type of Fire
extinguisher to be installed.
Providing and fixing Carbon-di-oxide fire
extinguishers consisting of welded M.S cylindrical
body,squeeze lever discharge valve fitted with
internal discharge tube, ISI marked high pressure
discharge hose, discharge nozzle, suspension
bracket, confirming to IS : 15683 finished
externally with red enamel paint and fixed to
wall with brackets with rawl plug/dash fasteners
complete with internal charge with CO2 gas
conforming to IS : 307-1996..
Capacity 4.5 kg. I.S.I. Marked. (IS : 15683 :
Providing and fixing ABC stored pressure dry
chemical powder (mono ammonium phosphate)
Fire Extinguisher IS : 15683 latest revision
manufacturer and of CRCA sheet in welded
construction, finish with High quality epoxy
polyster powder coated complete with brass forged
ball valve, gun metal cap and nozzle, including
initial filled and wall suspension bracket (suitable
for fighting in class 'A', B & 'C' that is wood,
textile, flammable liquid, electric and gases).
Supplying, installation, testing and commissioning
of Mechanical Foam type 9 litre capacity Fire
Extinguisher, ISI marked, IS: 10204, containing
540 ml AFFF liquid ISI marked, IS: 4989 Part II
32 and a polyurethane coated CO2 Gas Cartridge, ISI Each 24.000 3967.00 95208.00
marked, IS: 4947 complete with gunmetal union
cap, nylon hose with plastic foam making branch
and wall mounting bracket as per direction of
Engineer-in-charge.
Supplying and installing at approved location
approved make fire buckets at 24 gauge
galvanized steel sheet, standard 9 liters capacity
and of round bottom shape, painted white inside
32 and red outside and black on the bottom, inscribed Set 8.000 2691.00 21528.00
with letter "FIRE" in black and gold. Cost shall be
inclusive of Providing MS stand duly painted over
a coat of primer (one stand shall be suitable for
hanging 5 buckets.
IV) PART - IV : SPRINKLER SYSTEM :
Supply,Installation,Testing & Commissioning of
Pendent / Upright type Standrd Sprinkler with QB
of 68 /79 deg. C temperature rating and 1/2" end
connection confirming to IS: 15105 with ISI mark
for all floors etc. all complete as per direction of
Engineer-in-charge.
Supply,Installation,Testing & Commissioning of
150NB Alarm Valve , C/w Sprinkler Water Motor
Gong Retarded Chamber, Flange to:- ANSI B 16.
1 Class 125/ANSI B16.5 Class 100, All
Components are UL Listed/FM Approved , Rated
pressure 17.50 kg/cm2, Test pressure 500PSI
confirming to IS :15105:2002 with ISI mark as per
direction of Engineer-in-charge.
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Providing, fitting & fixing of following size cast
iron double flanged Y type strainer with SS 304
perforated screen confirming to IS 1538 with ISI
mark of pressure rating PN-1.60 including fixing
the same with supply of required jointing materials
35 like rubber insertion, MS nuts & bolts, paint etc.
and testing the joints with required water pressure
& all complete as per specification & direction of
KIRLOSKAR/IVC/ZOLOTO/VENUS/HONEYW
Providing, fitting & fixing of following size Bronze
flanged type Globe Valve with hand wheel
Confirming to IS -13114 : 1991 with ISI mark of
pressure ratting PN-1.60 including fixing the same
36 with supply of required jointing materials like
flanges, rubber insertion, MS nuts & bolts, paint
etc. and testing the joints with required water
pressure for all floors etc. all complete as per
specification & direction of E.I.C.
Supply,Installation,Testing & Commissioning of C.
I. Sight glass with 25 NB Gunmetal Globe Valve
with CI hand wheel ISI Mark for all floors etc. all
complete as per direction of Engineer-in-charge.
Providing, fitting and fixing of C.I. single Air relief
valve with stop cock confirming to IS:14845/2000
with ISI mark for water works purpose including
fixing the same with hydrant riser including testing
& commissioning the system etc. all complete as
per approved specification & direction of EIC.
Providing & fixing of Water Flow Switch 150 mm
39 Diameter with all accessories for all floors etc. all Nos 6.000 4791.00 28746.00
complete as per direction of Engineer-in-charge.
Providing & fixing of 25 mm size Gunmetal
Pressure Release Valve with isolation valve and
all accessories conforming to IS3233:1965 as per
direction of Engineer-in-charge.
Supplying, laying, testing and commissioning of
approved make 2x 2.5 Sq.mm. FRLS PVC
insulated Copper conductor, single core cable in
41 existing surface/recessed conduit for annunciation Rm 250.000 53.00 13250.00
panel of flow switch on the sprinkler line capable
of sending impulses to the control room with
Providing, laying, testing & commissioning of
Flexible Sprinkler Hose Corrugated Unbraided
type of size 1000 mm for Fire Sprinklers, with 1''
42 Inlet Nipple BSPT,1/2" Outlet Reducer BSPT,0.7 Nos 685.000 664.00 454840.00
m Square Supports Bar & Brackets(UL Listed)
with all complete accessories as per direction of
Engineer-in-charge.
Providing all materials, labour, T&P for laying of
following dia M.S. heavy class pipes conforming
to IS:1239 with ISI mark & required sizes of fitting
like off set, bend, tee, reducer flange & flange
joints etc. as per site condition including gas
cutting by oxygen and acetelene gas flame, fitting
and setting as per required size wherever
necessary, jointing the pipes by electric welding
confirming to IS specification and electrodes
confirming to IS specification after 'V' grove
cutting. Aligning the pipes inside the trenches
43 including necessary excavation of earth work of
required width & depth in all kinds of soil /rock
and back filling or supporting/fixing the pipe on
floor / wall /ceiling with clamps, hangers (using
anchor fasteners) or angle iron, G.I. pipe sleeve of
suitable higher size shall be provided wherever the
pipes are crossing the walls/floors and sealing the
sleeves with glass wool in between & fire sealent
compound at either end all as per the approved
specification including cutting holes and chases in
brick/RCC wall/roof/chajja and making good the
same to original condition.
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
All hangers, clamps, brackets etc. shall be of
galvanized iron unless specified otherwise and then
supply of the same shall also be included. Painting
2 (two) or more coats with synthetic enamel paint
of Post office red shade over a coat of primer for
above ground level & painting 2 (two) or more
coats with anticorrosive epoxy paint for below
ground level. Prior to application of primer the
surface should be cleaned for any dirt, rusts, rough
substance etc. Including painting of legends both
direction arrow as per the approved specification
including testing & commissioning the system.The
cost inclusive of hire and running charges of
welding generator set & all taxes, duties,
transportation, hire & running charges of
machineries, POL, to & fro charges with all
consumables for all floors etc. all complete as per
specification & direction of EIC. Make-
SAIL/JINDAL/TATA
PART - VI : AUTOMATIC FIRE ALARMING
AND DETECTION SYSTEM:
Supplying installation testing and commissioning
of Microprocessor based Addressable Fire Alarm
Control Panel (6 loop ) suitable for serving the
followingg detectors & Devices in maximum with
LCD display, complete withb) 2 Nos 12 Volt 40
44 Ah SMF battery, Battery backup and also No 1.000 582778.00 582778.00
provision for 2 Nos potential free Normally open
contact per loop to be used for interlocking with
provision for interface along PA Controller
including call station in built suitable for 240 watt
amplifier as per direction of Engineer-incharge.
Supplying installation testing and commissioning
of Addressable Photoelectric type Smoke-Cum-
45 Heat Detector(Multi Type), complete with base, Nos 1120.000 3904.00 4372480.00
isolator and accessories for above false ceiling as
per direction of Engineer-in-charge.
Supplying installation testing and commissioning
of Addressable Manual Pull Station(MPC),
46 complete with addressable mini input module, Nos 24.000 3356.00 80544.00
back box and accessories as per direction of
Engineer-in-charge.
Visual type Response indicators with LED
indicating lamp, housed in suitable MS enclosure
with acrylic cover fixed in flush with wall to
operate in conjunction with smoke/Heat detectors.
Supplying installation testing and commissioning
of Audio Visual Strobe, complete with mounting
box and accessories and module if require as per
direction of Engineer-incharge.
Supplying, installing ,testing and commissioning of
Hooter Cum Strobe at 85 dBA @ 3m for Audible
annunciation and 75cd flashing at 1 Hz for visual
indication. With Control Module. The Hooter cum
49 Strobe with Control Module shall be flush or Each 24.000 5593.00 134232.00
surface mountable type with all accessories etc.,
complete and as per technical specification. The
devices shall be of EN and LPCP listed.
Supplying installation testing and commissioning
of a pair of 1.5 sq.mm single core flexible copper
cable (2X1.5sq mm) to be laid within Existing MS
50 conduit of suitable size to be erected above the Mtr. 6500.000 37.00 240500.00
wall or concealed, as the case may be, with all
accessories as per direction of Engineer-in-charge.
Supply, delivery and laying of following sizes of
PVC Conduit in surface/ in recess alongwith other
51 accessories and 18 swg GI wire complete for Fire
Alarm wiring including painting as required and as
per direction of Engineer-in-charge.
PART - VI : AUTOMATIC FIRE DETECTION
VI) SUPPRESSION SYSTEM FOR ELECTRIC
Supply,installation, testing & commissioning of 5
LB capacity Novec 1230 , DLP Assembly with
automatic valve, push in connector for tube, 5 LB
Novec 1230 gas , mounting bracket, End of Line
adopter and low pressure switch for monitoring
system activation.
Linear pneumatic heat Detection Tube (size: 6 mm
53 Outer Dia & 4mm inner dia) with all necessary mtrs. 200.000 2604.00 520800.00
fittings & supports.
Qnty. Shedule Qnty. Non- Rate For Non- OSR Non-Shedule Item
SL.No. Description of Item Unit Item Shedule Item Rate For OSR Shedule Item Amount in Rs. Amount in Rs.
Master Control Unit with Audio Visual Alarm
With Wiring to Make Complete System
Operational. The Control Panel Should have
Provision for integration with Fire Alarm System.
PUBLIC ADDRESSING SYSTEM: TWO WAY
TALK BACK SYSTEM
Supply, Installation, Testing and Commissioning of
6/3/1.5 Watts wall mounted/ Ceiling speaker unit
complete as required. Make - Bosch -
LBD0606/10 / Bose / Biamp
Supply, Installation, Testing and Commissioning of
Power Amplifier, 480 watts with output
transformer, Multiple outputs - 70 V / 100 V and
8/4 ohm,Temperature controlled forced front to
back ventilation, directly stackable,Mains, battery
back-up, and pilot tone supervision,Dual inputs
with priority switchingetc complete as required or
equivalent.Make - Bosch / Bose / Biamp
Supply, Installation, Testing and Commissioning of
Plena Voice Alarm controller 6 emergency and 6
business triggers, built‑in 240 W amplifier
provides the power for the emergency call channel
and BGM limiter for improved intelligibility,
Output power (rms/maximum) 240 W / 360
W,Power reduction on backup power-1
dB,Frequency response 60 Hz to 18 kHz (+1/-3 dB
at -10 dBref. rated output),LED indication for
zone selection, fault. complete as require or
equivalent.Make -(BOSCH LBB
1990/Bose/Biamp)
Supply, Installation, Testing and Commissioning of
6 Zones Call stationSelectable gain, speech filter,
limiter, and output level for improved
58 intelligibility, LED indications for zone selection, Nos. 4.000 32000.00 128000.00
fault, and emergency state complete as required or
equivalent. Make -BOSCH LBB 1956
Supply, installation, testing and commissioning of
36U Equipment Rack complete with monitor unit,
speaker, power supply control etc complete as
required. Make - Netrack/Valrack
Supply, laying, termination of 2 Core 1.5 sq mm
PVC insulated copper conductor cable
Loudspeaker cables with PVC Conduit complete
as required. Make - Kystal/Falcon/Polycab
VIII) PART - VII : MISCELLANEOUS WORK :
Single sided EXIT LED Light fitting signage(both
side visible) with built in battery back-up for 2 hrs
with proper wiring with PVC conduiting from the
existing power sources for all floors etc. Make:-
BAJAJ (CAT No : BESL O3 LED SSD WBB
Green) / Equivalent
aoc.pdf
Download all tender documents and submit your bid