| 1 | 1₹16.9 LAccepted-AOC A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹20.6 L+₹2.8 L (15.5%)Rejected-Finance | 2 | Rejected-Finance other than L1 | |
| 3 | 3₹22.2 L+₹4.4 L (24.6%)Rejected-Finance 1 OPP NAGAR NIGAM KATNI MAIN ROAD KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | 3 | Rejected-Finance other than L1 | |
| 4 | 4₹23.3 L+₹5.5 L (30.8%)Rejected-Finance G 58 KIRAN GARDEN UTTAM NAGAR NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | 4 | Rejected-Finance other than L1 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/ MAINT OF EARTHING INFRA AND MISC E/M REPAIR/ REPLMT OF OLD U/S EARTHING LA SYSTEM, STRIP, EARTH PIT, PREVENTIVE MAINT OF E/M INST INCL PNEUMATIC PRESSURE PIPELINE AND HIGH MAST LIGHT, MISC E/M WRK AT TECH AREA AND VSB, AF STN UNDER GE (AF)TKD
2024_MES_668436_1
GE/TKD-51/2024-25
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹0
₹84,000
Yes
11 Nov 2024
31 Aug 2024
30 Sept 2024
31 Aug 2024
28 Sept 2024
16 Sept 2024
Amount
Testing of earthing and dismantling the strip from earth pit and testing of earth pit to be done as per fall of potential method mentioned in IS-3043 with digital earth resistance tester to check the healthiness of earthing system and record should be kept in record duly signed by user representative and submitted to Engr in charge complete all as specified and directed by Engr-in-Charge. Note: The testing of earth pit shall be done as and when required basis as directed by Engineer-in-Charge from time to time.
M&L in replacement for earthing with electrode should be 2 No’s Copper Plate of size 90cmx60cmx5mm inter connected with 50 X 6 mm copper strip of length 1.5 mtrs and in center shall be 32 X 6 mm copper strip of 3 meter with suitable brass nut bolts and brazing for lower resistance. Alternate layers of Soil & Curec+ or equilent (03 kgs x 5 bag) ; make as per IEEE 80 2000 , Clause 14.5 D, Maintenance Free Earthing System to give Earthing Resistance value of ≤ 1Ω. The soil shall be mixed with backfill CURENITE por equivalent (25-kgs x 10 bags) complete all as specified and directed by Engr-in-Charge. Copper Electrode’s should be solid rod of dia Mini 18 mm outer dia and surrounded with highly conductive and non corrosive nature (pH value certified) & covered with Poly plastic Earth Pit Cover in and including construction of PCC boundry with specified colour coding around the poly plastic pit cover.
M&L in repair for dismantling of old existing PCC earthing pit with cover and new construction of earthing PCC earthing pit with new polyplastic earth pit cover heavy duty with sign board triangular shape, making connection of earth strip including minor adjustment, construction of rectangular of size 0.75 x 0.75 x 0.50 (LXBXH) brick boundary alongwith necessary plastering work with specified colour coding around poly plastic earth pit cover, complete all as specified and directed by Engr-in-Charge.
M&L in repair of old existing PCC earthing pit making connection of earth strip including minor adjustment, construction of rectangular/squre any size brick boundary alongwith necessary plastering work with specified colour coding around poly plastic earth pit cover, complete all as specified and directed by Engr-in-Charge.
M&L for one coat painting of old existing Earthing pit in existing colour complete all as specified and directed by Engr in charge
M&L in replacement for GI brazing (welding) at site to connect loop GI earthing strip of any size after tighten by nut, bolt , washer , checknuts all as specified and as directed by Engr-in-charge. Note : GI brazing should be done any hight height. Cost of necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted.
M&L in replacement for copper brazing (welding) at site to connect loop copper earthing strip of any size after tighten by nut, bolt , washer, checknuts of brass, complete all as specified and as directed by Engr-in-charge. Note : copper brazing should be done any height. rate of necessary tool/plant and ladder required for working upto 20 mtr height shall be deemed to be included in the rate quoted
Supply installation in replacement, testing and commissioning of maintenance free earthing system. The earthing set shall comprise of :- (a) 1 No of copper bonded rod of diameter 17.2 mm and length of 10 feet UL approved with 25 KA current discharge test from CPRI. The material shall below carbon high tensile copper bonded rods with 99.9 % of copper on the surface. The UL approval certificate shall be provided. (b) The electrode shall be installed in a 100mm dia 3000mm deep augured bore hole. The augured bore hole shall be filled with highly conductive and eco friendly ground enhancing compound as per IEC 62561-7 shall be not less than 30kg per pit. (c) 1 No. of copper busbar of size 25 x 6 x 150 mm should be exothermic welded with copper bonded rod 17.2 mm dia x 3 mtr length. (d) 1 No. of PVC Pit cover for covering of earthing. (e) Exothermic connection of 25x6x150 mm busbar to 35 sqmm copper cable. (f) 35 sq mm PVC insulated copper cable for interconnection of earthing and equipment. Quoted rate shall deemd to include the cost of copper cable 35 Sqmm upto 7.5m with 15mm light grade GI protection pipe.
Labour for physical inspection for earthing health and to check the healthiness of earthing system whether the resistance under safe limits of resistance higher than the permissible then recharging of earthing should be done immediately with carbon based low resistivity compound Recharging of existing earth pit by excavating soil up to electrode depth appox 10 feet by manual drilling (post hole) method and filling with backfill compound maintenance free earthing compound as supplied saperately achieve resistance value less than 1 ohms in chamical earting and normal earting 2 ohm including water up to top of the excavated bore, backfilling of earth pit may be done and measured the value after refilling pit and testing of earthing after recharging,complete all as specified and directed by Engineer-in-Charge Note: (i) In case of satisfactory results not found or result degraded during one year of recharging of earthing the same shall be made good/recharged again in order to have requried test results within contract/Defect liability period without any extra cost to the department. (ii) contractor will mark each earthing with date of recharging of earthing. (iii) Necessary compound required for recharging shall be measured and paid seperately.
Supply only carbon based low resistivity compound .001 ohm meter, backfill compound for maintenance free earthing compound to achieve desired resistance value less than 1 ohms complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement of copper strip of size 32 x 6 mm of in short pieces on surface or in recess for all inter-connecting and connecting saddle, fixed to wall, underground, ceiling or in floor with new taking out worn out and damaged strip, complete all as specified and directed by Engr-in-Charge.
S&F in replacement of Copper strip 20 x 3.15mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement 25x4 mm GI strip in short pieces on surface or in recess for all interconnecting, in and including taking out worn out and damaged strip complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement 32x6 mm GI strip in short pieces on surface or in recess for all interconnecting, in and including taking out worn out and damaged strip complete all as specified and directed by Engr-in-Charge.
S&F in replacement aluminium strip 25 x 3 complete with saddles and fixing screwes for roof conductors down conductors complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement single phase rolling shutter gate motor powerful suitable for with a mximum gate weight capacity 500 kg,Power source- 230 V-1 phase electromechanical gear motor rolling shutter for industrial hangers complete with encoder,Control Unit 230V, rolling shutter tube 60 mm, dia winding flange 200 mm, Power-0 450 W, Amperage-2 A, frequeny 50 Hz, insulation class F,Capacitor - mF, RPM -9, Torque - 142 N-M ,Max rising height- 7 Meter, short team rotation- -8 Min, T with automatically by button or controller manually & limit switches, Enviremental temperature -25 to degrre C to + 50 Degree C, With inbuilt control box and infrared photo cell sensor including remote,Highest relative humidity: 95 %(25 deg C) with 10 minutes continous operation at most in and including Dismantling of unserviceable rolling shutter motor from the shaft of shutter for carrying out necessary cleaning and replacement of unserviceable parts complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement three phase rolling shutter gate motor up to 3 HP powerful suitable for with a mximum gate weight capacity 1000 kg,Power source- 220 V-1 phase electromechanical gear motor rolling shutter for industrial hangers up to 1000 kg complete with encoder,Control Unit 220V, rated power-, lifting force-10 KG, ouput torque- 345 N-M, Output rotate speed 6.2 mtr/min, Max rising height- 7 Meter, short team rotation- -8 Min, Own weight dropping torque ≤ 10 KG, standered drum diameter- 5 inch, sprocket specification (GB1243.1-81)- 10A-1*68, Sprocket Gear ratio - 9 T/47 T with automatically by button or controller manually & limit switches, Enviremental temperature -25 to degrre C to + 50 Degree C,Highest relative humidity: 95 %(25 deg C) with 10 minutes continous operation at most in and including Dismantling of unserviceable rolling shutter motor from the shaft of shutter for carrying out necessary cleaning and replacement of unserviiceable parts complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement on-load changeover switch 200A, 415 Volts, 4 Pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement on-load changeover by pass switch 320A, 415 Volts, 4 Pole with fastening element complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB 4 pole, 250 Amps with breaking capacity 36 KA, 415 volts ,adjustable thermal and fixed magnetic setting, Ics = 100% of Icu complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB 4 pole, 400 Amps with breaking capacity 36 KA, 415 volts ,adjustable thermal and fixed magnetic setting, Ics = 100% of Icu, complete all as specified and directed by Engr-in-Charge.
S&F in replacement Ball valve brass with iron handle screwed both ends for iron pipe and fixed complete all as specified and directed by Engr-in-Charge of following sizes :-
20mm bore
25mm bore
Supply, laying, in replacement jointing, welding & testing in replacement of MS pipe ( Heavy duty Class 'c') including fitting as required of following sizes laid in treches or laying on floor for connecting to various accessories and to connect outgoing air pressure main complete all as directed by Engr-in-charge. Note:- MS flange and flange joint complete with jointing material shall deemed to be included in the unit rate of this item
20 mm bore
25 mm bore
80 mm bore
M&L for rewinding of burnt compressor motor of capacity 2 HP rewinding with same gauge best quality copper enamelled winding wire and putting properly with packing materials, varnishings etc & drying & replacing wornout bearing/terminal plate, reassembling, fixing in original position, testing & commissioning all as directed by Engineer-in-charge.
S&F in replacement Single pointed air termination aluminium rod 12 mm dia 300 mm long complete all as specified and directed by Engr-in-Charge.
M&L in replacement for providing earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6.0mm thick buried directly in ground(Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and including galvanised earth strip 32 X 6 mm size up to 7.5 meter long by means of bolts, nuts check nuts and washers of all galvanised iron or steel all as shown in electrical plate No.5 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata, funnel with wire mesh and watering pipe(GI,light grade) 20mm dia,PCC pit with 50mm thick PCC cover etc. including testing on completing but excluding GI protection pipe for earthing lead all as directed at sire by Engineer-in-Charge.
S&F in replacement porcelain insulator 15 BMD type with nut bolts and screws for fixing copper strips on wall etc complete all as specified and directed by Engr-in-Charge.
S&F in replacement test terminal block made out of gun metal or phosphrous bronze size 150x 150 x 75 mm depth cutting upper and lower portion for incomming & out going including double insulators two coat of synthetic enamel paint complete all as specified and directed by Engr-in-Charge.
M&L for PCC 1:2:4 type BI using 20 mm graded stone aggregrate as in foundation complete all as specified and directed by Engr-in-Charge.
Servicing of High mast of any height and description, opening the mechanical hoisting / lowering assy, steel wire bobbin, replaceing the unservieable meshing gear, easying the steel rope movements, checking the locking mechanism, replaceing of oil, greasing complete and checking for smoothing operation of the mast, complete all as specified and directed by Engr-in-Charge.
Dismantling the AC motor of High mast and taking out to workshop for re-winding , removing the burntout windings, re-winding the same with super enamelled copper wire of existing guage,varnishing and oven drying , assembling and testing in position, complete all as specified and directed by Engr-in-Charge.
S&F in replacement, LED street light fitting of capacity 60 watt, cool white, complete with drivers and all accessories & making all necessary connection complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCCB 4 pole, 415V, fixed thermal and magnetic setting of capacity 63Amp, breaking capacity 10 KA complete suitable for fixing in inside LT Panel/feeder pillar complete all as specified and directed by Engr-in-Charge.
S&F in replacement MCCB 4 Pole 415 V, Adjustable type 160 Amps with breaking capacity 36 KA suitable for fixing in inside LT Panel/feeder pillar complete all as specified and directed by Engr-in-Charge.
Dismantling of old existing looping box duly disconnecting of incoming/outgoing cables & removing from site, supply installation and testing of non transparent SMC Kiosk box 3 phase with 4 No bus bar, 63 Amps aluminium 4 wire and 1 nos Kit kat fuse of 10 amps factory made out of 14 gauge steel sheet locking arrangement front side of suitable size 300x200x100 mm complete all as specified and directed by Engr-in-Charge.
S&F in replacement LED integral post top made in die cast aluminium housing with decorative clear opal acrylic diffuser and IP 65 protection capacity 1 x 40 Watt complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SP 5 to 32 Amp 240V, 10KA breaking capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB SPN 32 amp 240V,10KA breaking capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB TPN 4 pole 16 to 32 amp 415 volt, 10 KA breaking capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement of MCB TPN 4 pole 40 to 63 amp 415 volt 10 KA breaking capacity complete all as specified and directed by Engr-in-Charge.
S&F in replacement, LED street light fitting of capacity 90 watt, cool white, complete with drivers and all accessories & making all necessary connection complete all as specified and directed by Engr-in-Charge.
S&F in replacement of 70 Sq mm copper cable multistranded complete all as specified and directed by Engr-in-Charge.
S&F in replacement of A one 4 Kg ABC powder type Fire Extinguisher with wall mounted complete all as specified and directed by Engr-in-Charge.
S&F in replacement of steel tubular swaged poles complete with cast iron base plate, final taper plug, bolt nut and screws as specified type 410 SP-22, 9 mtr long complete all as specified and directed by Engr-in-Charge.
S&F in replacement of drivers for street / flood lilght fix on high mast/pole/bldg at any height and refixing the same location of upto 150 watt, complete all as specified and directed by Engr-in-Charge.
Cutting and removing the vegetation growth and surface dressing, trimming of branches from trees comming on the sub station or all around the installation yard including two pole structure area around power house (external only) to keep always installation clean and tidy including white wash at plinth / foundation of transformer if required complete all as specified and directed by Engr-in-Charge.
M/S Delhi Engineering Co. (BID ID -3096788)
Neeraj Enterprises (BID ID -3119739)
Sumit Enterprises (BID ID -3118689)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .