Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.9 LAccepted-AOC NEAR JAMIA MASJID HOSPITAL ROAD UDHAMPUR J K 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC l1 | |
| 2 | L2₹79.6 L+₹4.9 L (6.61%)Rejected-Finance R O WARD NO 08 H NO 108 DHAR ROAD UDHAMPUR TEHSIL DISTT UDHAMPUR 182101 | UDHAMPUR | UDHAMPUR | JAMMU KASHMIR | 182101 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹83.7 L+₹9.1 L (12.1%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹92.6 L+₹18.0 L (24.1%)Rejected-Finance 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L4 | Rejected-Finance Not being L1 | |
| 5 | Rejected-Technical | - | Rejected-Technical No srl. No 09 of part-II of HQ CESC in WLR for QE Mar 2026. No srl. No 06 of part-II B of HQ CEWC in WLR for QE Dec 2025. |
| Sl No | Description | Qty | Unit | slathia construction works L2 | PANWAR ELECTRICALS L4 | PROACH ASSOCIATES BUILDERS & ENGINEERS L3 | CITY TOP ELECTRICAL WORKS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | M&L for comprehensive maint, Preventive and routine maintenance of 03 Nos of chilling machines Make : M/s Carrier of screw type compressor, 750 TR each, single stage, 3000 RPM, 415 Volts, 3 Ph, 50 Hz, shell & tube type condenser with carbon steel plate, copper tube, including carbon plate shell & tube flooded type chiller unit working with microprocessor base controls in sheet metal control panel,VFD control panel including busbar and connected accessories complete all as directed with following requirement / condition and for following items / equipment - | 11 | Per Month | 4,50,000 ₹49,50,000 Lowest | 5,60,000 ₹61,60,000 | 5,18,700 ₹57,05,700 | 4,50,000 ₹49,50,000 Lowest |
| 1.01Note : (a) The 04 (Four) preventive / periodical maintenance services and 01 (one) yearly comprehensive maintenance service to each chiller machines (03 nos) of Make : M/s Carrier of screw type compressor, 750 TR each, single stage, 3000 RPM, 415 Volts, 3 Ph, 50 Hz, shell & tube type condenser with carbon steel plate, copper tube, including carbon plate shell & tube flooded type chiller unit working with microprocessor base controls in sheet metal control panel during the currency of the contract. The contractor shall submit the record of periodical/preventive/Annual maintenance services carried out by only M/s Carrier (OEM) along with documentary evidence for claiming payment. | |||||||
| 1.02(b) The repair / replacement cost (M&L) of all defective parts / spares, as and when required, is deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect at any stage. (c) During entire contract period, any defective component(s) and/or any other materials which is not specified /given in Schedule ‘A’, but essential to be repair/replace, to make plant(s)/machine(s) fully functional, the cost of the same is deemed. | |||||||
| 1.03(d) The entire work as mentioned in srl item no 1.00, shall be got executed through OEM i.e. M/s Carrier AC & Ref Ltd or equivalent OEM only. The contractor will submit copy of MOU with the OEM immediately after placing of W.O by the GE. | |||||||
| 1.04(e) The chiller machines along with connected items will be handed over to contractor in running condition, but with fair wear & tear which can be meet out through annual comprehensive maintenance. Hence, the bidder is advised to visit the site to assess the quantum of work to be carried out in this contract and quote their rates accordingly and no claim in this effect will be accepted at any stage. | |||||||
| 1.05(f) All the complained / faults will be addressed within 30 min from the time of receipt of complaint. If, contractor or his tradesmen fails to attend the complained within 30 min from the time of receipt of complaint, the compensation/penalty of Rs. 500.00 (Rupees Five Hundred only) per complaint per hr for first 04 hrs and after that Rs. 1000.00 (Rupees One Thousand only) per complaint per hr shall be recovered from the contractor’s dues. | |||||||
| 1.06(g) The cost of transportation (to and fro) and other necessary equipment shall be arranged / brought by contractor to complete the job and no extra cost shall be paid to the contractor in this effect. | |||||||
| 2.00 | M&L for complete overhauling of Primary pump/Secondary pump / chiller centrifugal pump set of 120 /100 HP by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting suction & discharge water lines and removing of electric connection, dismantling the U/S pump set from MS foundation, detaching the pump, opening the pump, re-metaling the shaft and filling of metal at decayed portions including all kind of machine works i.e. welding, turning, polishing etc. as required to make the shaft of required shape and size, as original, balancing the shaft and refitting in pump body; complete replacement of impeller set with new; replacement of Cushy foot anti vibration pad with and including carrying out complete repair / replacement of damaged parts i.e. bearings, bush, gland plate, Pump seal, coupling assembly etc. and reassembling the pump after greasing of moving parts and reinstallation of the pump with motor in original location using new MS stud, nut, bolt, washer and other packing material etc.; checking the alignment; reconnecting the suction and delivery pipes, making proper electric connection, testing and commissioning for smooth operation at optimum efficiency, complete all as directed. | 9 | Each Job | 25,000 ₹2,25,000 | 20,000 ₹1,80,000 | 17,500 ₹1,57,500 | 15,000 ₹1,35,000 Lowest |
| 3.00 | All as per srl item no 2 here-in-before but for 15 HP capacity. | 4 | Each Job | 20,000 ₹80,000 | 8,000 ₹32,000 Lowest | 13,000 ₹52,000 | 8,000 ₹32,000 Lowest |
| 4.00 | M&L for dismantling of electric driven horizontal induction motor of capacity 100/120 HP of any type and make, by engaging sufficient man power and suitable T&P to ensure safety of pump-motor as well as working persons including disconnecting of electric connections, dismantling of motor, taking out the burnt windings, cleaning and washing of slots and rewinding the same with copper winding wire of existing gauge and quantity (as per original manufacturer design) including replacement of all damaged parts i. e. bearings, bush, thrust plate, thrust bearing, connector plate, insulating materials such as insulating sheets insulating paper (Class "F"), sealing compounds etc. and reassembling the motor after varnishing, heating/drying, greasing of moving parts etc. and reinstallation of the motor in original location, checking the alignment, making proper electric connection, testing for smooth operation, complete all as directed.
Note : (i) The cost of winding wire and all replaced defective parts are deemed to be included in quoted rates and no extra cost shall be paid to the contractor in this effect. (ii) The cost of transportation (to and fro) and other necessary equipment shall be arranged/brought by contractor to complete the job at site or at repair shop and no extra cost shall be paid to the contractor in this effect. | 2 | Each Job | 45,000 ₹90,000 Lowest | 1,00,000 ₹2,00,000 | 65,000 ₹1,30,000 | 90,000 ₹1,80,000 |
Tender Value
₹100.0 L
EMD Value
₹1.8 L
Closing Date
11 Jun 2026, 6:00 pmClosed
Col Neelima CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
REPAIR/MAINT OF CHILLER, COOLING TOWER AND CONNECTED ACCESSORIES OF CHNC UNDER GE (UTILITIES) UDHAMPUR
2026_MES_765267_1
CWE/U(U)-20/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
UDHAMPUR
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (UTILITIES) UDHAMPUR
₹1.8 L
18 Aug 2026
14 May 2026
13 Jun 2026
14 May 2026
11 Jun 2026
4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | M&L for comprehensive maint, Preventive and routine maintenance of 03 Nos of chilling machines Make : M/s Carrier of screw type compressor, 750 TR each, single stage, 3000 RPM, 415 Volts, 3 Ph, 50 Hz, shell & tube type condenser with carbon steel plate, copper tube, including carbon plate shell & tube flooded type chiller unit working with microprocessor base controls in sheet metal control panel,VFD control panel including busbar and connected accessories complete all as directed with following requirement / condition and for following items / equipment - | 11 | Per Month | 10 | ₹110 |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
Tenderdocuments.pdf
Tender Documents • 2.21 MB
BOQ_857101.xls
BOQ • 0.30 MB
A20.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .