Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LAccepted-AOC | L1 | Accepted-AOC L1 Accepted | |
| 2 | L2₹49.9 L+₹9,622 (0.19%)Rejected-Finance | L2 | Rejected-Finance Other than L1 After deducting schedule of credit Rs 2,04,650.00 | |
| 3 | L3₹50.9 L+₹1.1 L (2.21%)Rejected-Finance H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | L3 | Rejected-Finance Other than L1 After deducting schedule of credit Rs 2,04,650.00 |
Tender Value
Refer Docs
EMD Value
₹99,900
Closing Date
28 Dec 2022, 6:00 pmClosed
GE NORTH AKHNOOR
GE NORTH AKHNOOR Pin 181201 CO 56 APO
REPAIR MAINT OF WATER SUPPLY DISTRIBUTION PIPE LINE INCLUDING REPAIR MAINT OF SOLAR WATER HEATERS ELECTRIC PANELS INCLUDING CONNECTED WORKS UNDER GE N AKHNOOR
2022_MES_566128_1
GE(N)/AKH-72/2022-23
Open Tender
Civil Works
Item Rate
180 days
Akhnoor
D Class cat a ii
8 documents required · 8 mandatory
₹500
GE NORTH AKHNOOR
₹99,900
Yes
28 Feb 2023
30 Nov 2022
30 Dec 2022
30 Nov 2022
28 Dec 2022
14 Dec 2022
Amount
Dismantling carefully each panel of solar water heater capacity 1000 LPD (each panel of 100 LPD = 10 Nos) including hot and cold pipe line network,collection water tank located between the bldgs at 50 Armd Regt and shifting entire panels and connected water supply tanks, hot water collection tanks on the bldg roof (double storey) and reassembling, reinstallation all as specified and dirceted by Engr-in-charge. Note: 1 Any damage caused during shifting of panels on roof shall be made good by the contractor with replacement. 2 All Civil work and replacement and servicing shall be measured and paid separately
Dismantling carefully each panel of solar water heater capacity 200 LPD including hot and cold pipe line network,collection water tank located between the bldgs at 50 Armd Regt and shifting entire panels and connected water supply tanks, hot water collection tanks on the bldg roof (double storey) and reassembling, reinstallation all as specified and dirceted by Engr-in-charge. Note: 1 Any damage caused during shifting of panels on roof shall be made good by the contractor with replacement. 2 All Civil work and replacement and servicing shall be measured and paid separetly
M & L for descaling of the collectors and hot water tank 1000 Ltrs Cap with the chemical solvent for removing all silt/rust complete and making the whole system leak proof complete all as specified and directed.
M & L for descaling of the collectors and hot water tank 500 Ltrs Cap with the chemical solvent for removing all silt/rust complete and making the whole system leak proof complete all as specified and directed.
M & L for descaling of the collectors and hot water tank 200 Ltrs Cap with the chemical solvent for removing all silt/rust complete and making the whole system leak proof complete all as specified and directed.
M & L for descaling of the collectors and hot water tank 100 Ltrs Cap with the chemical solvent for removing all silt/rust complete and making the whole system leak proof complete all as specified and directed.
Supply, fabrication and fixing feeder pillar box of size 500x 450x500 mm made out of MS sheet of 2.0mm thick bent to shape & size factory made with welding, bending works suitable for and including 200 Amps rated aluminium bus bars ( length of bus bar not less than 40 cm) 4No's ,making holes of any size and mounted on porcelain/epoxy based post insulators of appropriate size with suitable size of nuts, bolts and washers complete with mounting leg of size 40x40x5 mm and length of angle iron not less than 1 mtr, 0.5 mtr to be embeded in PCC below G.L and 0.5 mtr above ground including painting of complete structure with two coats of super enamelled synthetic paint over a coat of red oxide and incoming/out going cable connections with required size of cable lugs with proper crimping.
Material and labour for heating element ISI marked capacity 3 KW all as specified and directed.
Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 6 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 10 sqmm 2 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Taking down burnt cable and supply, laying, jointing and testing XLPE cable insulated, armoured, earthed, heavy duty electric cable with aluminium conductor , 1100 Volt grade, cross sectional area 16 sqmm 4 core including necessary cable lugs, glands, insulation tape etc complete all as specified and as directed.
Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size 25mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP25SMIV Make Anchor or equivalent in Kalinga, supreme
Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size 32 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP32SMIV Make Anchor or equivalent in Kalinga, supreme
Taking down UNSV PVC rigid pipe and M&L for MMS heavy duty PVC rigid pipe in concealed size 40 mm having thickness 2mm ISI marked and making good surface of plaster and colour matching with existing wall all as specified and directed Cat Part No CP40SMIV Make Anchor or equivalent in Kalinga, supreme
Material and labour for solar panel having 5 mm thick toughned glass size 6'x4' all as specified and directed.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation laying of pole stay assembly and laying of LT/HT cable and getting out in any type of soil complete all as specified and directed by the Engr-in-Charge
Returning filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in ant type of soil complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point
Supply and laying sub class `B` bricks laid dry flat transversely along the length of cable with width equal to the length of bricks over sand cushioning as protection cover of cable laid, complete all as specified and directed.
M & L for dry coarse sand as cushioning to cable 8 cm before laying HT/LT cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and directed.
M&L for aluminium sheet cladding over hot pipe for insulation incl binding clamp all as specified and directed.
M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade,FRLS type, PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 2.5 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade,FRLSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface including cutting and cheasing and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 2.5 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. Make of Cable Havells, KEI, Anchor
Dismantling all electrical/water connection from Industrial RO capacity 500 LPH and reconnect after replacement of following parts
(i) Supply only 40x40 membrane ISI marked all as specified and directed.
(ii) Supply only carbon and sand media all as specified and directed.
(iii) Supply only 20" big blue candle all as specified and directed.
Supply and fixing Rotational moulded polyethylene water storage tanks capacity 1000 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I® all as specified and directed.
Supply and fixing Rotational moulded polyethylene water storage tanks capacity 500 ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I® all as specified and directed.
M&L for Lagging to pipes 25mm dia used in internal water supply or plumbing all round with,40 mm thick bonded mineral wool preformed ‘SNAP ON’pipe sections of density 144Kg/cum con forming to IS 9843 incl chicken mesh and wrapping with 0.01 mm thick aluminium foil all as specified and directed.
M&L for Lagging to pipes 40mm dia used in internal water supply or plumbing all round with,40 mm thick bonded mineral wool preformed ‘SNAP ON’pipe sections of density 144Kg/cum con forming to IS 9843 incl chicken mesh and wrapping with 0.01 mm thick aluminium foil all as specified and directed.
M & L for PCC 1:2:4 type C-2 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete
S & F angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165.
Supplying and laying of CPVC pipes size 25mm dia SDR 11 & Plain CPVC SDR 11 fittings in walls/ceilings or in floors complete all as specified and directed.
Supply and fixing brass elbow size 25mm dia all as specified and directed.
Supply and fixing brass TEE size 25mm dia all as specified and directed.
Supply and fixing brass MTA/MBTA size 25mm dia all as specified and directed.
Supply and fixing brass FTA/FBTA size 25mm dia all as specified and directed.
Supply and fixing brass ball valve size 25mm dia all as specified and directed.
Supply and fixing brass union size 25mm dia all as specified and directed.
Supply and fixing brass Tank adoptar size 25mm dia all as specified and directed.
Supplying and laying of CPVC pipes size 32mm dia SDR 11 & Plain CPVC SDR 11 fittings in walls/ceilings or in floors complete all as specified and directed.
Supply and fixing brass elbow size 32mm dia all as specified and directed.
Supply and fixing brass TEE size 32mm dia all as specified and directed.
Supply and fixing brass MTA/MBTA size 32mm dia all as specified and directed.
Supply and fixing brass FTA/FBTA size 32mm dia all as specified and directed.
Supply and fixing brass ball valve size 32mm dia all as specified and directed.
Supply and fixing brass union size 32 mm dia all as specified and directed.
Supply and fixing brass Tank adoptar size 32 mm dia all as specified and directed.
Supplying and laying of CPVC pipes size 20mm dia SDR 11 & Plain CPVC SDR 11 fittings in walls/ceilings or in floors complete all as specified and directed.
Supply and fixing brass elbow size 20mm dia all as specified and directed.
Supply and fixing brass TEE size 20mm dia all as specified and directed.
Supply and fixing brass MTA/MBTA size 20mm dia all as specified and directed.
Supply and fixing brass FTA/FBTA size 20mm dia all as specified and directed.
Supply and fixing brass ball valve size 20mm dia all as specified and directed.
Supply and fixing brass union size 20mm dia all as specified and directed.
Supply and fixing brass Tank adoptar size 20mm dia all as specified and directed.
Supply and installation in repairs, commissioning and testing Polycarbonate ASTA CPRI approved OEM made main LT Panel. The panel shall be made of modular POLYCARBONATE THERMOPLASTIC ENCLOSURES including MCCBs and indicator lamps which shall be UV resistance in accordance with IEC 61439-1, clause 10.2.4: The panel shall be anti-acid & anti corrosive. Degree of protection against mechanical load shall be IK08 (5 Joule) in accordance with IEC 62262. The manufacturer of panel shall submit a copy of ASTA CPRI TEST REPORT IN POLYCARBONATE only also share panel assembled by OEM, channel partner or sister concern assembly will not be accepted. DEGREE OF INGRESS PROTECTION IP 65 IN ACCORDANCE WITH IEC 60529. The gasket shall be internally embedded made of polyurethane. The Panels made by aprroved enclosures in MES & they shall submit a copy of TYPE TEST REPORT of a board made out of Polycarbonate thermoplastic panel in accordance with IEC 60439-1. The ASTA CPRI report shall have mention of following tests performed and passed out satisfactorily - Temperature Rise, Dielectric Properties, Short circuit withstand current – Rated peak & short time withstand current and Rated Conditional Short Circuit Current, Effectiveness of Protective Circuits. The board manufacturer shall submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test Reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer. The panel shall pass glow wire test 960 degrees Centigrade in accordance with 60695-2-11 [flame retardant and self-extinguishing]. Make-Hensel/Rittal/Emitter/Schneider
INCOMER:
Main MCCB 160A 4Pole Breaking Capacity 36KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 No.
Digital VAF Meter with Volt,Amp, Frequency – 1 No
LED Indicator Lamp R,Y,B – 3 Nos
CT coils 160/5A – 3 Nos
Control Fuse – 3 Nos
Outgoings
MCCB 125A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 1 Nos.
MCCB 100A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 2 Nos.
MCCB 63A 4Pole Breaking Capacity 36 KA Adj. Thermal and Magnetic Setting with Spreader Links & Extended Rotary Handle – 2 Nos.
Excavation in trenches n. exc.1.5m wide and n. exc. 1.5m in depth for foundation of pole,laying of pipe line and getting out in any type of soil complete all as specified and directed by the Engr-in-Charge
Returining filling in including spreading ,levelling,watering and wall ramming in layers not exc 25cm in ant type of soil complete all as specified and directed.
Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point all as specified and directed.
S&F GI water tubing in replacement 15mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
S&F GI water tubing in replacement 20 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
S&F GI water tubing in replacement 25mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
S&F GI water tubing in replacement 40mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
S&F GI water tubing in replacement 50 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
S&F GI water tubing in replacement 80 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
S&F GI water tubing in replacement 100 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
S&F GI water tubing in replacement 150 mm bore 'medium grade', galvanized, with all fittings like socket, union, elbow, bend, tees etc jointed and laid in trenches complete all as specified and as directed by Engr-in-Charge. Make Tata, parkash Surya, Jindal
Supply and fixing “Lithium based Energy Efficient Integrated Solar Street Light of 24Watt” in Single FRP body with duly Polyurethane coating (Camouflage color) , encases with Monocrystalline Solar PV Panel of 53/55Wp , Lithium Battery 11.1/12.8V, 28.6AH with inbuilt BMS, IP 65, High brightness W-LED(160-180lm/watt) lamp with Aluminum reflector for better light distribution , CRI >70, Color Temperature 5700K - 6500K, Microcontroller based charge controller cum driver, automatic dimming function ( first four hours at full brightness & rest of the time at lower light level with PIR Motion Sensor), Dusk to Dawn Operation, suitable to working temperature: (-) 10C to (+)55C, weight not more than 12-14kg with adjustable MS clamp suitable for pole/wall mounting etc complete as required. Protections: Short Circuit, overload, Reverse polarity and battery protections. Firm should provide Vital Parameters Test report from NABL accredited lab and should be of made in India with CE & ROHS compliant. Make:- Axxon (AXN-24W) or equivalent in Bajaj /phillips/SURYA/Havells
Construction of valve pit i replacement of sizes 120cmx120cmx120cm (internal dimentions), brick construction, including all necessary excavation and earth work in hard/loose soil, returning, filling in, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, PCC in foundation of the mix (1:4:8), type D-2, (using 40mm graded crushed stone aggregate) brick masonry in cement mortar (1:4) rendering, 12 mm thick cement mortar (1:4), internally, finished even and fair pointing flush externaly as the work proceeds in the same mortar, mild steel frame, MS sheet cover 5mm thick with handle and locking arrangement, painting all the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint complete all as specified.
Construction of brick masonary valve pit in replacement of size 90 x 90 x 90cm (Internal dimensions of chamber from top of PCC to bottom of cover) including excavation in any type of soil returning, filling around foundation and removal of surplus soil to a distance not exceeding 50m PCC 1:4:8 type D2 in foundation brick work in cement mortar 1:6, 10mm thick plaster in cement mortar 1:4 to internal surface covered pit with MS sheet cover 3.15 mm thick with locking arrangement, handle fixing arrangement fixed on 40mm PCC 1:2:4 type B-1 coping and painting with oil paint two coat over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge.
Taking down old unsv sluice valve and Supply and fixing ball valve having SS ball with both CI end flanged,ISI marked, with nuts,bolts and washers and rubber gaskets with stainless steel handle over PVC coating complete all as specified and directed for following bore pipe:- Make BVI,BIR,Kirloskar
(a) 150mm dia
(b) 100mm dia
(c) 80mm dia
(d) 50mm dia
Supply and fixing non return valve heavy duty both ends flanged ISI marked complete with nuts, bolts washers etc complete all as specified and directed by Engr-in-charge of following sizes:- Make BVI,BIR,Kirloskar
(a) 150mm dia
(b) 100mm dia
Taking out old US gate valve, M&L for ball brass valves,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete of sizes :- Make BVI, BIR,Zoloto,leader
(a) 15mm bore of pipe
(b) 20mm bore of pipe
(c) 25mm bore of pipe
(d) 40mm bore of pipe
(e) 50mm bore of pipe
Surface excavation n exc 30cm deep and averaging 15 cm any type of soil all as specified and directed.
M&L for rolling and consolidating of soling of broken boulders not exceeding 15cm thick with power roller exc 5 tonne and nexc 8 Tonne.
M&L for broken stone boulder hardcore of guage exc 63mm but n exc 100mm deposited, spread and levelled in layers n exc 15cm thick watered and rolled/rammed to a true surface.
M&L for cement concrete in foundation, filling and mass concrete type D2 1:4:8 40 mm graded (100mm) all as specified and directed.
M&L for cement concreteT ype B2 1:2:4 40 mm graded Aggrgrate all specified and directed.
M&L for 80 mm thickness M-40 Grade Machine pressed precast conctete interlocking paver block any shape and size confirming to IS 15658-2006, jointed and pointed with grey cement and no pigment including sand cushioning and PCC lock at edges, complete all as specified and directed. Make-Ruchi or equivalent
Supply, laying and testing in replacement of mild steel ERW pipe line 150 mm dia 5.4mm thickness flanged type confirming to IS 7161 incl MS flanges and rubber gasket with required no of holes, required no nos of MS connecting pieces and required nos of nuts, bolts , washers of suitable sizes incl cutting of pipes weldinfg work and drilling holes incl taking out old CI/DI/MS pipe laid in trenches complete all as specified and directed Make Electrosteel casting Ltd or equivalent in TATA, JINDAL.
Supply and fixing Glow sign board made of acrylic sheet reactangular shape having lighting arrangement of superior quality of size 5'x2'x8" showing installation Nomenclature as approved marked all as specified and directed. Note: Installation line diagram to be enfaced will be approved by AGE E/M and no extra will be paid of any addition and alteration of words or marking of colours.
Fabrication of angle stand made of angle size 50x50x6mm for Glow sign board, incl jointing of Tees,incl PCC for foundation all as specified and directed
Supply and fixing in replacement connection cable multistranded single core PVC insulated copper conductor cable incl PVC conduit pipe from starter to motor or vice versa of size of cable 120 sqmm complete all as specified and directed by Engr in charge
Surface dressing in hard/dense soil n exc averaging 15cm deep for cleaning the area by cutting the unwanted bushes/vegitation growth in and around the area of installations/around the valve pit chamber/along the pipe line route if required etc all as specified and directed.
One coat of S/E paint on old steel surfaces including preparation of old painted surface not otherwise described over 10 cm width or girth complete all as specified and directed by Engr-in-Charge.
Taking down unsv false ceiling and supply and fixing anodised aluminium snap grid frame work for false ceiling size of grid 605 x 605 mm with 12mm perforated particle board /tiles of size 600mmx600mm complete with GI Hangers adjusted level fixed to roofs slabs by means of ceiling cleats made out of GI flat and fasteners 12.5 mm dia , 40mm long complete all as specified.
Supply and fixing of DWC HDPE tubing 50 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates
Supply and fixing of DWC HDPE tubing 80 mm bore for open/underground laying cable, cut to size and making the tubing for cable protection including cutting of road etc/cutting of PCC and making the good surface complete all as specified and directed by Engr-in-Charge. (a) The using of GI Clamp in the wall/drainage rate are deemed to be included in the quoted rate. (b) The insulation of DWC pipe should be of high that does not deteriorate with UV rays/ heavy sun rays/winter season etc. (c) Drawing existing cable through DWC pipe shall be deemed to be included in the quoted rates
ASIA ENTERPRISES
M/S A K ENGINEERS & CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .