Loading…
Loading…
Tender Value
₹3.5 Cr
EMD Value
₹3.2 L
Closing Date
24 Mar 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
SIGNAL
13 conditions · 2 needing a document upload
For Financial criteria, Please refer to the attached documents - "Tender Document", "GCC April2022 with all ACS".
For Technical criteria, Please refer to the attached documents - "Tender Document", "GCC April2022 with all ACS".
5 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Please refer to the attached documents - "Tender Document", "GCC April2022 with all ACS".
Comprehensive Annual Maintenance Contract of Data loggers and RTUs along with its networking over Pune division of Central Railway for a period of three years.
CR-PA-SNT-REV-S-2026-11
CR-PA-SNT-REV-S-2026-11
Single
Works - General
36 Months
Pune, Maharashtra
₹0
₹3.2 L
24 Mar 2026
27 Feb 2026
10 Mar 2026
26 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,45,15,272.56 | ||
| Annual Maintenance of Micro processor based Remote Terminal Unit of 64D/16A' Input along with communication module for three years. NOTE - This Include maintenance of Remote Terminal Unit and Modems. Any defective In any part of Remote Terminal Unit is to be repaired / replaced. (52 RTUs for 36 months) | — | — | — | 31,77,832.32 | |
| Annual Maintenance of Micro processor based Remote Terminal Unit of 64D/16A' Input along with communication module for three years. NOTE - This Include maintenance of Remote Terminal Unit and Modems. Any defective In any part of Remote Terminal Unit is to be repaired / replaced. (01 RTUs for 35 months) | — | — | — | 59,414.6 | |
| "Annual Maintenance of Micro processor based Remote Terminal Unit of 64D/16A' Input along with communication module for three years. NOTE - This Include maintenance of Remote Terminal Unit and Modems. Any defective In any part of Remote Terminal Unit is to be repaired/replaced. (01 RTUs for 30 months)" | — | — | — | 50,926.8 | |
| "Annual Maintenance of Micro processor based Remote Terminal Unit of 64D/16A' Input along with communication module for three years. NOTE - This Include maintenance of Remote Terminal Unit and Modems. Any defective In any part of Remote Terminal Unit is to be repaired/replaced. (01 RTUs for 26 months)" | — | — | — | 44,136.56 | |
| Annual maintenance of Microprocessor based Data Logger system of 512 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (20 Dataloggers for 36 months) | — | — | — | 35,25,984 | |
| Annual maintenance of Microprocessor based Data Logger system of 512 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (1 Dataloggers for 25 months) | — | — | — | 1,22,430 | |
| Annual maintenance of Microprocessor based Data Logger system of 1024 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (56 Dataloggers for 36 months) | — | — | — | 1,19,71,431.36 | |
| Annual maintenance of Microprocessor based Data Logger system of 1024 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (04 Dataloggers for 32 months) | — | — | — | 7,60,090.88 | |
| Annual maintenance of Microprocessor based Data Logger system of 1024 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (02 Dataloggers for 30 months) | — | — | — | 3,56,292.6 | |
| Annual maintenance of Microprocessor based Data Logger system of 1024 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (02 Dataloggers for 27 months) | — | — | — | 3,20,663.34 | |
| Annual maintenance of Microprocessor based Data Logger system of 1024 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (01 Dataloggers for 26 months) | — | — | — | 1,54,393.46 | |
| Annual maintenance of Microprocessor based Data Logger system of 2048 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (01 Dataloggers for 36 months) | — | — | — | 4,95,317.52 | |
| Annual maintenance of Microprocessor based Data Logger system of 2048 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (01 Dataloggers for 26 months) | — | — | — | 3,57,729.32 | |
| Annual maintenance of Microprocessor based Data Logger system of 2560 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (02 Datalogger for 36 months) | — | — | — | 6,99,598.08 | |
| Annual maintenance of Microprocessor based Data Logger system of 2560 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (01 Datalogger for 32 months) | — | — | — | 3,10,932.48 | |
| Annual maintenance of Microprocessor based Data Logger system of 4096 Digital and 32 Analog input with power supply unit and communication interface complete at station / cabin. This including all the maintenance (repair / replacement) of software & Hardware of Data Logger, includes modems, mother boards, printer and circuit board. Any defect in part of Data logger is to be repair / replacement & maintenance of power supply equipment i.e. battery and charger etc. on Pune Division. (03 Dataloggers for 36 months) | — | — | — | 15,44,889.24 | |
| "Annual Maintenance of Front end processor (FEP) hardware, Mother boards and circuit boards. Note - This includes Repair / Replacement / maintenance of associated hardware Mother boards and circuit boards. (8 FEPs for 36 months)." | — | — | — | 5,76,443.52 | |
| Annual Maintenance of Failure Analysis System (FAS) of Software and hardware of Compurer. Note - This includes Repair/ Replacement / maintenance of associated hardware Mother boards and circuit boards along with computer. (89 FAS for 36 months). | — | — | — | 58,49,542.8 | |
| Annual Maintenance of High-End Data logger Server repair of Software and hardware. Any defect in any part is to be repaired. (02 server for 36 months). | — | — | — | 1,30,217.04 | |
| Annual Maintenance of CMU in testroom inclusive of software and hardware. (9 CMUs for 36 months). | — | — | — | 10,26,739.8 | |
| Annual Maintenance of station master Data Entry Terminal COA Systems (Daund) (5 COA for 36 months). | — | — | — | 10,78,970.4 | |
| Annual Maintenance of SSI Protocol (54 SSI for 36 months). | — | — | — | 13,58,642.16 | |
| Annual Maintenance of GSM Modem. (4 modem for 36 months) | — | — | — | 3,63,215.52 | |
| Annual Maintenance of LRS PC (2 LRS PC for 36 months) | — | — | — | 1,31,450.4 | |
| Annual Maintenance of firewall (1 firewall for 36 months) | — | — | — | 47,988.36 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocument_Datalogger_AMC.pdf
ATTACHMENT
GCC April 2022 with all ACS
ATTACHMENT
GCC_April-2022_With_All_Correction_SlipsACS10.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .