Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAccepted-AOC B 106 1ST FLOOR GAUTAM BUDDHA NAGAR NOIDA DELHI DELHI 201301 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201301 | ₹1.0 Cr | L1 | Accepted-AOC L-1 Bidder |
| 2 | L2₹1.0 Cr+₹41,265 (0.40%)Rejected-AOC C 74 FIRST FLOOR DDA SHED PHASE 1 OKHLA INDUSTRIAL AREA NEW DELHI DELHI 110020 | SOUTH EAST DELHI | DELHI | 110020 | ₹1.0 Cr+₹41,265 (0.40%) | L2 | Rejected-AOC L-2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical Not Eligible as per ENIT. |
| Sl No | Description | Qty | Unit | DSS Electric Corporation LLP L1 | Ground eca3g Private Limited L2 |
|---|---|---|---|---|---|
| 1.00Supply, Installation, Testing & Commissioning of E-N Compensator Digital Grounding Device built in Low Impedance equipment Grounding & bonding system. Provides 100% protection against Lightning Surges, static charge, Noises, ESD, EPR and eliminates abnormal electrical disturbances which enter from power and other service lines and ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V with inbuilt connection facility the display of Resistance and Ground to Neutral values on existing scada with a facility to set threshold value on all equipments connected hereafter having pre wired, pulverent body painted metallic enclosure which is to be connected in parallel to the existing power supply circuit. This three phase E-N Compensator Digital Grounding Device should be tested and certified from CPRI, MIL STD810G, IEC61000-6-1, IEC 61000-6-3,IEC 61643-11-2011 & confirming to ISO 9000 & ISO 14001-2015 & CE. (DATS site ) | |||||
| 1.01 | 480 KA, Wheel Mountable | 5 | Nos. | 4,78,000 ₹23,90,000 Lowest | 4,80,000 ₹24,00,000 |
| 1.02 | 240KA, Wall Mounted | 26 | Nos. | 1,70,900 ₹44,43,400 Lowest | 1,71,000 ₹44,46,000 |
| 2.00Supply, Installation, Testing & Commissioning of E-N Compensator Digital Grounding Device built in Low Impedance equipment Grounding & bonding system. Provides 100% protection against Lightning Surges, static charge, Noises, ESD, EPR and eliminates abnormal electrical disturbances which enter from power and other service lines and ensuring clear bonding potential (earth to Neutral voltage) less than 1.0V with inbuilt facility to display of Resistance and Ground to Neutral values on all equipments connected hereafter having pre wired, pulverent body painted metallic enclosure which is to be connected in parallel to the existing power supply circuit. This three phase E-N Compensator Digital Grounding Device should be tested and certified from CPRI, MIL STD810G, IEC61000-6-1, IEC 61000-6-3,IEC 61643-11-2011 & confirming to ISO 9000 & ISO 14001-2015 & CE. (Bijwasan site ) | |||||
| 2.01 | 480 KA, Wheel Mountable | 4 | Nos. | 4,78,000 ₹19,12,000 Lowest | 4,80,000 ₹19,20,000 |
| 2.02 | 240KA, Wall Mounted | 2 | Nos. | 1,70,900 ₹3,41,800 Lowest | 1,71,000 ₹3,42,000 |
| 3.00 | Supply and Laying of flexible 2-core shielded cable suitable for electrical and signal communication | 2,000 | Mtr. | 410 ₹8,20,000 Lowest | 420 ₹8,40,000 |
| 4.00 | Supply of two way multiple wire connector port shall be compatible with existin SCADA system | 35 | Nos. | 185 ₹6,475 Lowest | 190 ₹6,650 |
| 5.00 | Supply of PowerFlex4-Class DSI RJ45 Terminal block shall be compatible with existing SCADA system | 40 | Nos. | 3,100 ₹1,24,000 | 3,050 ₹1,22,000 Lowest |
| 6.00 | Supply of PLC Cards to the existing SCADA system | 3 | Nos. | 81,900 ₹2,45,700 Lowest | 82,450 ₹2,47,350 |
Tender Value
₹1.1 Cr
EMD Value
₹3.2 L
Closing Date
2 Jan 2026, 5:00 pmClosed
Sr Manager EE
DATS Complex IGI Airport
Provision of E-N Compensator in different panels at DATS complex and Bijwasan site.
2025_AAI_258759_1
AAI/DATS/EN-Comp/2025-26
Open Tender
Electrical Works
Item Rate
90 days
DATS Complex IGI Airport
Not Applicable
7 documents required · 7 mandatory
₹1,180
₹3.2 L
6 Apr 2026
12 Dec 2025
5 Jan 2026
12 Dec 2025
2 Jan 2026
12 Dec 2025
12 Dec 2025 - 16 Dec 2025
480 KA, Wheel Mountable
240KA, Wall Mounted
480 KA, Wheel Mountable
240KA, Wall Mounted
Supply and Laying of flexible 2-core shielded cable suitable for electrical and signal communication
Supply of two way multiple wire connector port shall be compatible with existin SCADA system
Supply of PowerFlex4-Class DSI RJ45 Terminal block shall be compatible with existing SCADA system
Supply of PLC Cards to the existing SCADA system
Integration of item no 1,4,5 and 6 in co- ordination with OEM i.e. M/s Rockwell In the existing SCADA sytem.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
TenderDoc.pdf
Tender Documents • 14.12 MB
BOQ_298985.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .