Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC 601 603 EROS APARTMENT 56 NEHRU PLACE NEW DELHI 110019 | NEW DELHI | NEW DELHI | DELHI | 110019 | ₹15.9 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹16.4 LRejected-Finance 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | ₹16.4 L | L2 | Rejected-Finance L2 |
| 3 | L3₹16.4 LRejected-Finance | ₹16.4 L | L3 | Rejected-Finance L3 |
| Sl No | Description | Qty | Unit | Globe Detective Agency Pvt. Ltd. L1 | Awasthi Electric Works L2 | FAIRDEAL ASSOCIATES L3 |
|---|---|---|---|---|---|---|
| 1.00A. FIRE FIGHTING SYSTEM | ||||||
| 1.01A. REPAIR, MAINTENANCE CHANGE OF DAMAGE SPARES OF EXISTING FIRE HYDRANT, PUMP HOUSE & FIRST AID FIRE FIGHTING SYSTEM. | ||||||
| 1.02 | Supply & replacement of Damage Fire Hydrant Valve by new one and made it serviceable with all washers etc. as required Inside & Outside the Terminal Building. | 4 | Nos | 4,600 ₹18,400 | 5,200 ₹20,800 | 4,800 ₹19,200 |
| 2.00 | Servicing of Fire Hydrant Valve with Changing of all Washers etc.as required Inside & Outside the Terminal Building. | 3 | Nos | 287.5 ₹862.50 | 5,200 ₹15,600 | 650 ₹1,950 |
| 3.00 | Supply & replacement of damaged External Fire Hose Box by New one with all reqired fixing items. | 2 | Nos | 3,680 ₹7,360 | 4,600 ₹9,200 | 5,200 ₹10,400 |
| 4.00 | Supply & Replacement of damaged 15 Mtrs RRL Hose by new one for External Hose Boxes. | 4 | Nos | 3,507.5 ₹14,030 | 4,300 ₹17,200 | 4,800 ₹19,200 |
| 5.00 | Supply & replacement of damaged 30 Mtrs 25 mm Hose Pipe with all require fittings & 1.5 mtr. to 2 Mtrs long Connecting Hose for Hose Reel Drum inside Terminal Building. | 5 | Set | 4,197.5 ₹20,987.50 | 5,400 ₹27,000 | 5,500 ₹27,500 |
| 6.00 | Hose Reel Drum to be Serviced & made Operational. | 5 | Set | 345 ₹1,725 | 1,950 ₹9,750 | 3,000 ₹15,000 |
| 7.00 | Supply & replacement of 25 mm GM Gate Valve for Swing Hose Reel. | 2 | Nos | 1,702 ₹3,404 | 2,925 ₹5,850 | 1,300 ₹2,600 |
| 8.00 | External Stand Post Pipes to be Painted. | 2 | Nos | 345 ₹690 | 1,950 ₹3,900 | 350 ₹700 |
Tender Value
₹16.4 L
EMD Value
₹32,859
Closing Date
30 Dec 2024, 10:00 amClosed
AGM(E-E)
AAI, Bagdogra Airport, Bagdogra
Modification of existing Fire Fighting system, Fire Alarm Detection System and augmentation / re-orientation of water supply system at Cooch Behar Airport.
2024_AAI_218042_1
AAI/CB/AGM-I/24-25/NIT/06/228
Open Tender
Electrical Works
120 days
AAI, Cooch Behar Airport
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹32,859
7 May 2026
7 Dec 2024
31 Dec 2024
7 Dec 2024
30 Dec 2024
7 Dec 2024
7 Dec 2024 - 13 Dec 2024
Amount
A. FIRE FIGHTING SYSTEM
A. REPAIR, MAINTENANCE CHANGE OF DAMAGE SPARES OF EXISTING FIRE HYDRANT, PUMP HOUSE & FIRST AID FIRE FIGHTING SYSTEM.
Supply & replacement of Damage Fire Hydrant Valve by new one and made it serviceable with all washers etc. as required Inside & Outside the Terminal Building.
Servicing of Fire Hydrant Valve with Changing of all Washers etc.as required Inside & Outside the Terminal Building.
Supply & replacement of damaged External Fire Hose Box by New one with all reqired fixing items.
Supply & Replacement of damaged 15 Mtrs RRL Hose by new one for External Hose Boxes.
Supply & replacement of damaged 30 Mtrs 25 mm Hose Pipe with all require fittings & 1.5 mtr. to 2 Mtrs long Connecting Hose for Hose Reel Drum inside Terminal Building.
Hose Reel Drum to be Serviced & made Operational.
Supply & replacement of 25 mm GM Gate Valve for Swing Hose Reel.
External Stand Post Pipes to be Painted.
One No Electrical Main Pump, One No Electrical Jockey Pump, and One No Diesel Engine Stand By Pump to be Serviced with Change of Gland Packing and all required servicing activities as required etc.
Pressure Gauges to be Replaced with SS Glycerin Filed Gauges.100 mm size ( 0- 20 kg/cm2)
Supply & replacement of all Pressure Switches by new one.
The Electrical Fire Pumps Panel to be Modified as Auto Manual System and the Entire Fire Hydrant System to be Kept in Auto Mode with installation of all reqred fittings and wirings.
All Portable Existing Fire Extinguishers to be Refilled and water based Fire Extinguishers to be Replaced with ABC-6 Kgs Capacity type Fire Extinguishers
Refilling of Co2 type Fire Extinguisher of Capacity-4.5 Kgs.
Refilling of DCP type Fire Extinguisher of Capacity-5 Kgs.
Supply & Installation of New Fire Extinguisher CO2 Type 4.5kgs capacity ISI Marked.
Supply & Installation of New Fire Extinguisher CO2 Type 2 kgs capacity ISI Marked.
B. NEW INSTALLATION SITC of New External Stand Post Hydrant with allied accessories to be erected both side of the Terminal Bulding in the city side including all required civil work and excavation.
SITC of 150 mm Pipe (H) New Pipe Lines to be Erected for the Said Work of new hydrant installation including all required civil work and excavation.
SITC of Beam Detector in the Terminal building and dismantling of old exsisting Smoke Detectors fitted in the Maximum Height (Roof Top) in the Open Lounge Area.
SITC of new Four Loop Addressable UL listed Fire Alarm Panel with auto Dialer & all required acessories.
SITC of Multi Criteria Detectors as per Fire Panel Make & System to be installed in the different rooms/office/toilets etc. area in the Terminal Building.
SITC of Addressable MCP in the Terminal Building.
SITC of Hooter in the Terminal Building.
SITC of Control Module in the Terminal Building.
Supply and laying of Electrical armoured FRLS cable 2 core x 1.5 sq mm in the Terminal Building.
Existing armoured cable dismentaling & Rewiring as per requirement with commissioning of new FAD system.
SITC of Conventional Type Fire Alarm Panel 2 zone capacity with battery back up.
SITC of Conventional Smoke Detector with base.
SITC of Conventional Manual Call Point.
SITC of Convential Hooter.
Supply & laying Electrical armoured FRLS cable 2 core x 1.5 sq mm.
B. WATER TRANSFER SYSTEM SITC of Horizontal type 3 HP/2.2KW 3PH, 415 Volt, 50 Hz Monoblock Pump Motor Set having discharging capacity 240 LPM on 28 mtrs head. Suction /delivery size: 65mm/50mm. The pump motor set will be fitted on suitable sizes M.S. angle iton frame complete with M.S. Nut Bolts etc. as required.
SITC of 3 HP, 3 PH DOL starter complete with M.S. angle iron frame, suitable for operation of aove pump-motor sets at site.
Supply & laying of 4 core 16 sqmm, A/Armoured Cable on wall/surface incl. sadling for necessary connection of above pump motor sets.
SITC of gland for above cable.
Supply & laying of 6 SWG G.I. Earth wire with both end socket.
Dismantling of the exitting Unserviceable suction/delivery GI Pipe line at site as required.
Supply & installation of GI Pipe of following dia as per site reqiorement;
65mm dia. (for suction)
50mm dia (for delivery)
Supply & installation of G.I. fittings as follows-
65 mm X 6" Niple
50 mm X 6" Niple
50 mm X 4" Niple
65 mm Elbow
50 mm Elbow
65 mm Union
50 mm Union
65 mm Tee
50 mm Tee
Supply & installation of Gun Metal valves as follows-
65 mm (V) check valve
50 mm (V) check valve
50 mm Fullway valve
Supply & laying 32 mm dia PVC pipe for cable protection.
Cutting of C.C. floor for making hole by machinery arrangement for 65 mm dia suction pipe in the sump.
Painting of the existing pipe lines (Suction/delivery ) with anticorrosive enamel paints over 2 coats of red oxide as per the instruction of the E.I.C. at site.
Awasthi Electric Works (BID ID -798526)
FAIRDEAL ASSOCIATES (BID ID -795240)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.16 MB
TENDERDOCUMENT.pdf
Tender Documents • 9.85 MB
BOQ_242196.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid