Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAccepted-AOC PLOT NO 15 JAYASURIYA STREET GANGAI NAGAR KALLIKUPPAM AMBATTUR CHENNAI 600053 | CHENNAI | CHENNAI | TAMIL NADU | 600053 | ₹5.0 L Quoted ₹5.1 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹5.3 L+₹21,500 (4.20%)Rejected-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | ₹5.3 L+₹21,500 (4.20%) | L2 | Rejected-AOC Other than lowest bidder |
Tender Value
₹5.8 L
EMD Value
₹11,600
Closing Date
16 Oct 2023, 6:00 pmClosed
AGE(I) Navy Chennai
AGE(I) Navy Chennai Military Engineer Services Fort St George Rajaji Salai Chennai 600 009
COMPREHENSIVE MAINTENANCE OF COLD ROOM AND COOL ROOM UNDER AGE(I) NAVY CHENNAI
2023_MES_618636_1
AGE(I)/NAVY/CHN/8438 of 2023 - 24
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
Chennai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Navy Chennai
₹11,600
Yes
2 Dec 2023
13 Sept 2023
17 Oct 2023
13 Sept 2023
16 Oct 2023
27 Sept 2023
14 Sept 2023 - 20 Sept 2023
Amount
Comprehensive maintenance and repairs including renewal/ replacement of defective parts for Cold room of total refrigeration Capacity 20,000 BTU/Hr consisting of following descriptions:- 01. Dimensions (External): 13’X 15 X 8’6”(ft) 02. Ambient Temperature: 40 ˚C to 42 ˚C. 03. Room Temperature: +2 to +8 DegC 04. Product incoming temperature: +30˚C 05. Product to be stored: Vegetables 07. Cold room Door: Flush Type self closing swing Door with SS/SS Lamination Inside and out sides. 60mm thick.34” x 78” clear opening Accessories: Anti-condensation door heater, Padlock, Posit seal closure, Human safety release knob.– One 08. Insulation: Pre-fab modular PUF panels - GREEN PANELS CycloPentane Blowing Agent 09. Thickness of Insulation: 60mm
10. Floor: 60mm floor panel with marine plywood and aluminium checker sheet 11.Refrigeration systems and model: Ruah 2014 Refrigerant R – 404a 12. No. of refrigeration systems: 2 no’s one stand by 13. Compressor Type: Reciprocating 14. Power Supply Requirement:415 V/ 3PH / 50 Hz/ 15. Provided wtth Digital temperature indicator cum controller safety alarm and strip curtain 16. 2 No. of Internal light fitting and all connected accessories provided as per OEM's installation instructions, complete all as specified and as directed. Make: Blue Star
Comprehensive maintenance and repairs including renewal/ replacement of defective parts for Cool room of total refrigeration Capacity 12,000 BTU/Hr consisting of following descriptions:- 01. Dimensions (External) : 7’X 15 X 8’6”(ft) 02. Ambient Temperature: 40 ˚C to 42 ˚C. 03. Room Temperature: 15 to -20 DegC 04. Product incoming temperature : - 15˚C 05. Product to be stored: Frozen foods 06. Room Temperature: Room Temperature 07. Cold room Door : Flush Type self closing swing Door with SS/SS Lamination Inside and out sides. 100mm thick.34” x 78” clear opening Accessories: Anti-condensation door heater, Padlock, Posit seal closure, Human safety release knob.– One 08. Insulation: Pre-fab modular PUF panels - GREEN PANELS CycloPentane Blowing Agent 09. Thickness of Insulation: 100mm
10. Floor: 100mm floor panel with marine plywood and aluminium checker sheet 11.Refrigeration systems and model: Danfos Refrigerant R – 404a 12. No. of refrigeration systems: 2 no’s one stand by 13. Compressor Type: Reciprocating 14. Power Supply Requirement: 415 V/ 3PH / 50 Hz/ 15. Provided wtth Digital temperature indicator cum controller safety alarm and strip curtain 16. 2 No. of Internal light fitting and all connected accessories provided as per OEM's installation instructions, complete all as specified and as directed. Make: Blue Star
Comprehensive maintenance of HVAC type package at NCN building by OEM Hitachi/ authorized dealer inclusive of labour, spares and consumables The rate is to be considered for Annual Maintenance of HVAC type package following capacity at NCN Bldg , Chennai. 1. HVAC Outdoor Unit 10 HP – 01 No 2. HVAC Outdoor Unit 06 HP – 03 Nos 3. HVAC Indoor Unit 1.5 Ton – 05 Nos 4. HVAC Indoor Unit 2.0 Ton – 01 No 5. HVAC Indoor Unit 2.5 Ton – 03 No 6. HVAC Split AC Unit 2.0 HP – 02 No 7. HVAC Split AC Unit 1.5 HP – 02 No and all connected accessories provided as per OEM's installation instructions, complete all as specified and as directed. Make: Hitachi
Notes for Item No 1 to 3 :- a. The above job include for servicing the plant four times during the Contract period as per OEM standard checklist. Checking the serviceability of spare parts, checking lubrication level & leakages, operating of safety valves and instruments all has to be included in the rates. b. The above job include for attending breakdown calls 24 x 7,and if not attending within 6 hrs Rs 1000/hr will be recovered. c. All spare parts of indoor/outdoor units including compressor, Fan motor for both IDU & ODU, Fan blade,Gas charging, Electrical items, wiring, PCBs, remotes, panel controller, painting, valves,arresting duct leakages with insulaitng material welding, soldering etc is to be included in the above item. d. Work also include for checking tubes, de-scaling and preventive coating or replacement. e. Job also include for replacement of unserviceable electrical wirings and MCCB TPN, MCBs if found damaged/unserviceable. f. Only genuine parts shall be used
Supply, fixing, testing and commissioning of Outdoor Coil suitable for outdoor Unit, complete all as specified and directed by Engr in Charge. Make : Blue Star
Supply, fixing, testing and commissioning of Indoor Coil suitable for Indoor unit, complete all as specified and directed by Engr in Charge. Make : Blue Star
Supply, fixing, testing and commissioning of Outdoor Coil suitable for outdoor HVAC type package 10 HP plant, all as specified and directed by Engr in Charge. Make : Hitachi
Supply, fixing, testing and commissioning of Outdoor Coil suitable for outdoor HVAC type package 6 HP plant,all as specified and directed by Engr in Charge. Make : Hitachi
Supply and fix 3 core 1.5 sqmm PVC insulated PVC sheathed weather proof multistranded copper conductor cable 1100 volts grade drawn through in PVC conduit, all as specified and directed.
M&L for earthing complete with galvanised steel plate earth electrode 600X600X6mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to GI strip 25X4mm at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : GI strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately.
M&L for Earth continuty conductor or main earthing lead as 25x4 mm GI strip fixed to wall on batten or recess or chasses or burried in ground or drawn in conduit /pipe or fixed to pole or any other situation for loop earthing etc.
EVEREST ENGINEERING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .