| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹11.7 LQualified Make: Koel Green Electro
Model: KOEL GREEN KG1-5AS WITH PART NO. 318004-1101 20 23 BHAGWANPUR RAIPUR SAHKARI AUDYOGIC KSHETRA HARIDWAR UTTARAKHAND 247661 | HARIDWAR | UTTARAKHAND | 247661 | Make: Koel Green Electro
Model: KOEL GREEN KG1-5AS WITH PART NO. 318004-1101 | L1 | Qualified | |
| 2 | Disqualified Make: KOHLER
Model: KOHLER-kdg0005p2 | Make: KOHLER
Model: KOHLER-kdg0005p2 | - | Disqualified | |
| 3 | Disqualified Make: Koel Green Elmech
Model: KG1-5AS WITH PART NO 18091-1213 NO 2 1402 1402 CHIRANJIV TOWER 43 NEHRU PLACE NEW DELHI 110019 NEHRU PLACE NEW DELHI UTTAR PRADESH 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: Koel Green Elmech
Model: KG1-5AS WITH PART NO 18091-1213 NO 2 | - | Disqualified | |
| 4 | Disqualified Make: MAHINDRA GSP RETAIL
Model: MAHINDRA 1125 GR 22 IIIRD FLOOR MAIN MARKET MOTI NAGAR DELHI DELHI 110015 | WEST DELHI | DELHI | 110015 | Make: MAHINDRA GSP RETAIL
Model: MAHINDRA 1125 GR | - | Disqualified | |
| 5 | Disqualified Make: EICHER ENGINES JAYCEE
Model: EICHER ENGINES JAYCEE & JPS/5001A 13 6 MATHURA ROAD NH 2 FARIDABAD HARYANA 121003 | FARIDABAD | HARYANA | 121003 | Make: EICHER ENGINES JAYCEE
Model: EICHER ENGINES JAYCEE & JPS/5001A | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
1 Jun 2018, 12:00 pmClosed
diesel generators- DG Sets Diesel Generators- DG Sets ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 5 5 No of Phase - Single phase
Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - BIS license No
if applicable - - Type of Engine cooling Air Cooled Air Cooled Type of governer Mechanical Mechanical Class of governer A2 A0
A1
A2 Number of cylinders (nos) 1 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500
3000 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 5 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 80.43 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6
1.8
2
1.2 Thickness of Foam 25 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number - - 2/4 and date(Engine) Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986
in respect of noise and emission norms
as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 1 Installation & Commissioning Without Installation With Installation
Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Hanumant Singh Rawat 110066
Office Of the DIGP
RAF-1
CRPF
East Block-2
Level-VII
Sector-1
R.K. Puram
New Delhi-110066 6 15 EMD Required No ePBG Required No
99275
GEM/2018/B/14165
diesel generators- DG Sets
15 days
Delhi; New Delhi
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| diesel generators- DG Sets Diesel Generators- DG Sets ( 6 ) Technical Specifications Specification Specification Name Values Allowed Values OUTPUT CAPACITY RATING/PHASE Nominal Rated Capacity (KVA) 5 5 No of Phase - Single phase | - | - | - |
| Three Phase ENGINE Make of Engine - - Model Number of Engine - - Capacity of Engine (cc) - - Engine Power (kWm) - - ISI Marking to IS :10001 for engine true - BIS license No | - | - | - |
| if applicable - - Type of Engine cooling Air Cooled Air Cooled Type of governer Mechanical Mechanical Class of governer A2 A0 | - | - | - |
| A1 | - | - | - |
| A2 Number of cylinders (nos) 1 - No of Strokes (nos) 4 - Rated RPM of Engine (RPM) - 1500 | - | - | - |
| 3000 1/4 Overload capacity for one hour for every 11 hours continuous running at full load (%) 10 - Specific Fuel Consumption (gm/kWh) - - Starting voltage (volt) 12 - ALTERNATOR AC GENERATOR(ALTER NATOR) Make - - AC GENERATOR(ALTER NATOR) model Number - - Rating of AC Generator (KVA) 5 - Power Factor of AC generator 0.8 - Efficiency at rated Power factor at 75% of full Load 80.43 - Compliance of Alternator to IS:13364(part-1) Yes - Type of alternator Brushless - Voltage Regulation Grade VG 3 - Alternator IP Rating IP 23 - Class of Insulation H - CONTROL PANEL Control Panel Manual Manual IP Rating of Control Panel IP 53 - ACOUSTIC ENCLOSURE Sheet Thickness 1.6 1.6 | - | - | - |
| 1.8 | - | - | - |
| 2 | - | - | - |
| 1.2 Thickness of Foam 25 - Density of Foam for sound insulation 28 - Noise level at 1 meter (dB) 75 - BATTERY Battery Type & Specification Low Maintenance free to IS: 14257 for high cranking performance - Battery capacity (Ah) - - No of batteries 1 - TEST REPORTS Availability of Type test report for Engine from Central govt/NABL/ILAC accredited laboratory Yes - Test Report number - - 2/4 and date(Engine) Name and address of laboratory(Engine) - - Availability of Type test report for Alternator from Central government/NABL/ILAC accredited laboratory Yes - Test Report number and date(Alternator) - - Name and address of laboratory(Alternator) - - DG set meet requirements of Enviro nmental(Protection) Rules 1986 | - | - | - |
| in respect of noise and emission norms | - | - | - |
| as described in STC Yes - WARRANTY INSTALLATION & COMMISSIONING Warranty 1 Installation & Commissioning Without Installation With Installation | - | - | - |
| Without Installation Agreed to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Hanumant Singh Rawat 110066 | - | - | - |
| Office Of the DIGP | - | - | - |
| RAF-1 | - | - | - |
| CRPF | - | - | - |
| East Block-2 | - | - | - |
| Level-VII | - | - | - |
| Sector-1 | - | - | - |
| R.K. Puram | - | - | - |
| New Delhi-110066 6 15 EMD Required No ePBG Required No | - | - | - |
Exempted
1 Jun 2018
17 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_99275.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .