Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.9 LAccepted-AOC 15 CP COLONY MORAR GWALIOR MP 474 006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | ₹10.9 L Quoted ₹11.3 L | L1 | Accepted-AOC AOC |
| 2 | L2₹14.0 LRejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | ₹14.0 L | L2 | Rejected-Finance Not being L1 bidder |
| 3 | L3₹17.0 LRejected-Finance | ₹17.0 L | L3 | Rejected-Finance Not being L1 bidder |
| 4 | L4₹18.2 LRejected-Finance | ₹18.2 L | L4 | Rejected-Finance Not being L1 bidder |
| Sl No | Description | Qty | Unit | Uma engineers L2 | M/s YOGESH ENTERPRISES L4 | M/S Rakesh Verma L3 | M/s Anupam Construction Co. L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | PART-I (WATER COOLER) Disconnecting, dismantling and taking out the non-functional Water coolers of any description, any make and in any position including water connections, capacity 40 ltrs to 150 ltrs, single phase, 50 Hz, strip opening, cleaning and servicing of the water cooler with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed by Engineer–in–charge. NOTE : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item. (ii) Replacement of unserviceable / damaged body portions of the water coolers shall also be measured and paid for separately under appropriate item of Schedule `A' as supply only but fixing/assembling element of new / repaired body parts with existing parts is deemed to be included under this item . (iii) Burnt out windings and internal wiring, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding & supply only of internal wiring kit (iv) The rates for above items are deemed to include for transportation to & fro of Water coolers to workshop as approved by Engineer-in-charge for necessary repairs and testing of Water coolers at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one. (v) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item (vi) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipe line including brazing of damaged portion of pipe line. | 24 | Each Job | 1,200 ₹28,800 | 3,500 ₹84,000 | 100 ₹2,400 | 700 ₹16,800 |
| 2.00 | Supply and Charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed by Engineer-in-Charge. | 20 | Per Kg | 1,100 ₹22,000 | 1,500 ₹30,000 | 1,000 ₹20,000 | 900 ₹18,000 |
| 3.00 | S&F single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB up to 20 amp ,240 volts and 10 KA complete all as specified & as directed. | 13 | Each | 650 ₹8,450 | 1,050 ₹13,650 | 1,200 ₹15,600 | 950 ₹12,350 |
| 4.00 | Supply only base Tray Stainless steel sheet for 40/60 ltrs. Capacity water cooler suitable for any make all as specified and directed by Engineer-in-charge. | 10 | Each | 1,250 ₹12,500 | 1,850 ₹18,500 | 1,000 ₹10,000 | 1,500 ₹15,000 |
| 5.00 | All as per item No 4 but of capacity 60/120 ltrs. | 9 | Each | 1,450 ₹13,050 | 1,950 ₹17,550 | 1,000 ₹9,000 | 1,700 ₹15,300 |
| 6.00 | Supply only side cover made of stainless steel sheet 40/60 ltrs capacity suitable for any make for water cooler complete all as specified and directed by Engineer-in-charge. | 5 | Each | 1,150 ₹5,750 | 1,900 ₹9,500 | 1,000 ₹5,000 | 2,000 ₹10,000 |
| 7.00 | All as per item No 6 but of capacity 60/120 ltrs. | 2 | Each | 1,200 ₹2,400 | 1,950 ₹3,900 | 1,000 ₹2,000 | 2,500 ₹5,000 |
| 8.00 | Supply only water storage tank with chiller as per existing description complete made of stainless steel suitable for 40/60 ltrs. capacity including copper tube suitable for any make , complete all as specified and directed -by Engineer-in-Charge. | 3 | Each | 2,200 ₹6,600 | 16,500 ₹49,500 | 5,000 ₹15,000 | 4,000 ₹12,000 |
| 9.00 | All as per item No 8 but of capacity 60/120ltr. | 3 | Each | 2,500 ₹7,500 | 17,000 ₹51,000 | 5,000 ₹15,000 | 5,000 ₹15,000 |
| 10.00 | Supply only PVC Gasket non- magnet for chiller top any make of water cooler including fixing arrangement complete all as specified and directed. | 24 | Rm | 250 ₹6,000 | 350 ₹8,400 | 500 ₹12,000 | 50 ₹1,200 |
Updated dates
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
27 Dec 2025, 6:00 pmClosed
GE(AF) ADM AREA
GE (AF) ADM AREA GWALIOR
REPAIR/ REPLACEMENT AND MAINT OF COOLING APPLIANCES AND CONNECTED WORKS AT AF STATION GWALIOR
2025_MES_741253_1
8544/E8
Open Tender
Civil Works
210 days
GE (AF) ADM AREA GWALIOR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) ADM AREA
₹40,000
Yes
31 Jan 2026
24 Nov 2025
1 Jan 2026
24 Nov 2025
27 Dec 2025
8 Dec 2025
Amount
PART-I (WATER COOLER) Disconnecting, dismantling and taking out the non-functional Water coolers of any description, any make and in any position including water connections, capacity 40 ltrs to 150 ltrs, single phase, 50 Hz, strip opening, cleaning and servicing of the water cooler with using MAIC-DS solution, taking out and removing unserviceable/defective wiring & damaged/un-serviceable parts, replacement of the unserviceable and defective parts, necessary brazing, reassembling water cooler, restoring water supply connections and testing of the water coolers complete as all specified and directed by Engineer–in–charge. NOTE : (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new/ repaired items are deemed to be included under this item. (ii) Replacement of unserviceable / damaged body portions of the water coolers shall also be measured and paid for separately under appropriate item of Schedule `A' as supply only but fixing/assembling element of new / repaired body parts with existing parts is deemed to be included under this item . (iii) Burnt out windings and internal wiring, if any, replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding & supply only of internal wiring kit (iv) The rates for above items are deemed to include for transportation to & fro of Water coolers to workshop as approved by Engineer-in-charge for necessary repairs and testing of Water coolers at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one. (v) Charging of gas to make up required pressure, if any, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item (vi) Rates quoted by the contractor for this item are also deemed to be included for de-scaling of chilled water pipe line including brazing of damaged portion of pipe line.
Supply and Charging of refrigerant Gas R-22 Mono chloro difluoro methane (CHCLF2) to make up the required pressure complete all as specified and directed by Engineer-in-Charge.
S&F single pole and neutral enclosure with two pin and earth plug and socket complete with one single pole MCB up to 20 amp ,240 volts and 10 KA complete all as specified & as directed.
Supply only base Tray Stainless steel sheet for 40/60 ltrs. Capacity water cooler suitable for any make all as specified and directed by Engineer-in-charge.
All as per item No 4 but of capacity 60/120 ltrs.
Supply only side cover made of stainless steel sheet 40/60 ltrs capacity suitable for any make for water cooler complete all as specified and directed by Engineer-in-charge.
All as per item No 6 but of capacity 60/120 ltrs.
Supply only water storage tank with chiller as per existing description complete made of stainless steel suitable for 40/60 ltrs. capacity including copper tube suitable for any make , complete all as specified and directed -by Engineer-in-Charge.
All as per item No 8 but of capacity 60/120ltr.
Supply only PVC Gasket non- magnet for chiller top any make of water cooler including fixing arrangement complete all as specified and directed.
Supply only Air cooled condenser with ventury, copper, 3 row , suitable for any type of refrigerant gas, 60/120 ltrs. capacity suitable for Make Blue star/ Voltas / Usha Shriram water coolers, complete all as specified and directed.
Supply only relay unit current type of existing description & existing description.
Supply only relay pin type (Potential type) of existing description & existing description.
Supply only starting capacitor 40/60 MFD of existing description & existing description.
Supply only capacitor 60/80 MFD of existing description & existing description.
Supply only capacitor 80/100 MFD of existing description & existing description.
Supply only Running capacitor 10 to 15 MFD of existing description & existing description.
Supply only Running capacitor 20 to 36 MFD of existing description & existing description.
Supply only Thermostat , 220 volts suitable for Make Blue star/ Voltas / Usha Shriram water coolers, complete all as specified and directed
Supply only over load protector (Suitable for any make / model of compressor all as approved by Engineer-in-Charge
Supply only AC electric condenser motor 25 Watt, 230 Volts, 1250 RPM single speed complete all as specified and directed.
Supply only AC electric condenser motor 30 to 35 Watt, 230 Volts, 930 RPM single speed complete all as specified and directed.
Supply only AC electric condenser motor 75 to 90 Watt, 230 Volts, 1400 RPM single speed complete all as specified and directed.
Supply only brass Nipple 15 mm Dia for inlet and out let connection of water cooler any type / size including one PVC connection 15 mm Dia with brass coupling on both ends complete all as specified and directed.
Supply only Drain Pipe PVC flexible 1¼” Dia with one end circle clip complete all as specified and directed.
Supply only wiring kit of flexible PVC insulated copper conductor cable of existing size complete all as specified and directed
Supply only CP brass Push cock, 15 mm. Dia (ISI marked) inner/outer threaded complete all as specified and directed
Supply only new sealed unit compressor for water coolers of any make and model, as approved by GE including vacuum testing and filling of Refrigerant Gas to required pressure complete all as specified and directed by Engineer - in - charge for the following capacity :- Note:- (i) The cost of fixing, brazing to suction and discharge line and testing of compressor at site is deemed to be included under Schedule `A' item No.1 (ii) Refrigerant gas for charging of compressors shall be measured and paid for separately under respective item of this Schedule.
(a) compressor suitable for 40 ltrs capacity water cooler.
(b) compressor suitable for 60 ltrs capacity water cooler.
(c) compressor suitable for 120 ltrs capacity water cooler.
(d) compressor suitable for 150 ltrs capacity water cooler.
Supply and fixing for fan blade of any type and any description suitable for water cooler of capacity 40 Ltrs complete all as specified and directed.
Supply and fixing for fan blade of any type and any description suitable for water cooler of capacity 60 Ltrs complete all as specified and directed.
Material and labour PVC connection 15mm Dia bore, 450mm long with both ends brass screwed socket and having high density pressure pipe . complete all as specified and directed by Engineer - in- charge.
PART- II (REFERIGERATOR) Disconnecting and taking out the non-functional Refrigerator of any description and in any position, strip opening of Refrigerator 165 Ltrs. to 330 Ltrs. Capacity, cleaning and servicing, taking out un-serviceable / defective parts/spares and internal wiring, replacement of un-serviceable parts/spares like Relay, capacitor, wiring , over load protector, Compressor, inner liner Puff, evaporator, freezer, condenser, Lamp & holders etc. necessary brazing, reassembling and testing all as specified and directed by Engineer-in-charge. Note- (i) Replacement of un-serviceable parts shall be measured and paid for separately under appropriate item of sch ‘A’ as supply only but fixing and testing element of the parts replaced / repaired is deemed to be included in this item. (ii) The rates for above items are deemed to include for transportation to & fro of Refrigerators to workshop as approved by Engineer-in-charge for necessary repairs and testing of Refrigerators at workshop & replacement of necessary unserviceable screws/nuts/bots/ washers/ packing etc with new one (iii) Charging of gas, if required, shall be measured and paid for separately under appropriate item of Schedule `A'. However, vacuum and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor for this item
Supply only following new parts suitable for refrigerator of any description and capacity 165 ltr to 420 ltrs :-
(a) Main door gasket magnetic type suitable for any type of Refrigerator.
(b) Thermostat switch with knob 230 volt suitable for single door refrigerator of any make and capacity 165 litre to 210 litre.
(c) Thermostat switch with knob 230 volt suitable for double door Ref. 230 to 350 ltrs of any make
(d) Relay Box type 220 volt 3 pin / 4 pin (Make KCL / Rent-roll / Indofos).
(e) Freezer door with spring & clamp suitable for existing refrigerator of any description and any capacity.
(f) Pin type / screw type bulb suitable for 165 ltrs. to 360 ltrs. Refrigerator
(g) Compressor water drain off tray of PVC as approved
(h) Door switch 230 volt
(j) Chiller tray plastic
(k) Refrigerator Freezer coil & freezer coil type/roll bound type complete suitable for 165 ltrs. to 230 ltrs. capacity
(l) Bulb holder assembly complete as per existing model
(m) Supply only condenser coil suitable for 165 to 230 ltrs capacity refrigerator of any description suitable for any model & make of LG/ Whirlpool/ Samsung.
(n) Supply only fan motor of frost free suitable for double door refrigerator of capacity 300 Ltrs to 420 Ltrs directed by Engineer-in-Charge. suitable for refrigerator of Make : LG / Whirlpool/Samsung
(o) Supply only bi-metal thermostat of capacity – 5 0 C cut in temperature suitable for 300 Ltrs to 360 Ltrs refrigerators of Make : LG / Whirlpool/ Samsung
(p) Supply only fuse for bi- metal thermostat of 650C / 700C suitable for 300 to 360 Ltrs refrigerators (Note for Srl item No 33) The cost of fixing and testing of spare parts is deemed to be included under Schedule `A' item No.32
Supply and charging of refrigerant gas 134A to make up the required pressure in any type refrigerator.
Supply only the following new sealed unit compressor for refrigerator of any make/model as approved by GE including vacuum testing and filling of Refrigerant Gas to required pressure.
(a) Refrigerator Compressor make : Godrej (Model No NAE-6, NAE-8), /Tecumseh (model No 1333, 1343) / Voltas (Model No DFC1, DFC2),
(b) Refrigerator compressor make LG (Model No 330 & 181)
PART- III (DESERT COOLER) Disconnecting and taking out the defective / non-functional desert cooler of any description and in any position and any floor installed at direct approach (where any ladders and other T&P are not required to remove the desert cooler from position), strip opening of desert cooler, cleaning, servicing, oiling & greasing etc of desert cooler, taking out and removing unserviceable / defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, re-assembling & testing of the desert cooler all as specified and directed by Engineer-in-Charge Note: - (i) The replacement of defective / nonfunctional parts shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under this item .and replacement of unserviceable / damaged body portions i.e. panels / switch board / bottom / top / grills / frame etc. of the desert cooler shall also be measured and paid for separately under appropriate item of Schedule `A'. (ii) Burnt out windings replaced, shall be measured and paid for separately under appropriate item of Sch ‘A’ for rewinding. (iii) The rates for above items are deemed to include for transportation to & fro of vertical pumps/fan motors to workshop as approved by Engineer-in-charge for necessary repairs, alignment and testing of pump and motors at workshop & replacement of necessary unserviceable screws/nuts/bolts/washers/ packing etc with new one.
Supply only PVC flexible water Pipe 15 mm Dia complete all as specified and directed by Engineer-in-Charge.
Supply only PVC distributor 3 way, suitable for 15mm Dia water distribution all as specified and directed by Engineer-in-Charge.
Supply only new 3 core PVC insulated copper conductor cable size 23/0.0076 round 1100 volt grade as in connection to desert coolers all as specified and directed by Engineer-in-Charge.
Supply only shaft for fan motor of desert cooler all as specified and directed by Engineer-in-Charge.
Taking out & removing old existing plywood of any description and in any position and supplying and fixing new plywood 4mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler air tight complete all as specified and directed by Engineer-in-Charge. (Make : Kitply / National/ Bhutan )
Supply only Air curtain panels (side and back removable panels) of any description and size for different size of desert coolers, made to shape and size with using 20 SWG gauge PGI sheets as per requirement including necessary mouldings etc to suit the existing cooler openings all as specified and directed by Engineer-in-Charge.
Supply only water Pump, 230 volts, 45 watt, 1400 RPM all as specified and directed by Engineer-in-Charge.
Supply only cooler fan kit (suitable for three fan blades) 230 volt 1/8 HP. 950 RPM, double ball bearing type all as specified and directed by Engineer-in-Charge.
Supply only cooler exhaust fan motor (suitable for three fan blades) 230 volt 1/8 HP. 950 RPM, double ball bearing type all as specified and directed by Engineer-in-Charge.
Supply only cooler fan motor for plastic body coolers (suitable for three fan blades) 230 volt 1/8 HP. 950 RPM, double ball bearing type all as specified and directed by Engineer-in-Charge.
Supply only aluminium fan blade ( set of three blades) for cooler motor of any description to suit existing motor all as specified and directed by Engineer-in-Charge. .
Supply only plastic fan blade ( set of three blades) for cooler motor of any description to suit existing motor all as specified and directed by Engineer-in-Charge. .
Supply and fixing in repair of chicken wire mesh with using new hexagonal wire mesh having 15mm size mesh and 0.5mm Dia of wire for supporting to the wood wool pads all as specified and directed by Engineer-in-Charge.
M&L forProviding new wood wool pads of required size as approved (three in each on desert cooler) complete material and labour all as specified and directed by Engineer-in-Charge.
M&L fo Replacement of existing unserviceable front grills of any description and in any position with supplying and fixing new grills of existing shape and size and made out of 20 SWG, PGI sheet complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 15mm Dia Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule all as specified and directed by Engineer-in-Charge.
Supply and fixing 15mm Dia Gun metal or gate valves, with iron wheel head, screwed, both end for iron pipe all as specified and directed by Engineer-in-Charge.
Supply and fixing PVC connection 15mm size 450mm length complete with PTMT nuts on both ends all as specified and directed by Engineer-in-Charge.
Taking down old / unsv/rusted GI tubing of 15/20 mm Dia and S&F GI tubing (ISI Marked) 20 mm Dia with including all fittings such as sockets, TEE, elbow, union etc all as specified and directed.
Supply and fixing plug top 15 amp 3 pin ,215 volts .
Supply and fixing plug top 05 amp 3 pin ,215 volts .
Uma engineers (BID ID -3504808)
M/S Rakesh Verma (BID ID -3509550)
M/s YOGESH ENTERPRISES (BID ID -3509194)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
Tender8544.pdf
Tender Documents • 0.95 MB
BOQ_830017.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid