Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.9 LAccepted-AOC | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹66.9 L+₹2.0 L (3.15%)Rejected-AOC 4A FOURT FLOOR CLASSIC RUDRA RAMANIYAM EAST AVENUE 3RD STREET THIRUVANMIYUR CHENNAI TAMIL NADU 600041 | CHENNAI | TAMIL NADU | 600041 | L2 | Rejected-AOC L2 bidder | |
| 3 | Rejected-Technical 17 2 MIG FLATS ASHOK NAGAR CHENNAI TAMIL NADU 600083 | CHENNAI | TAMIL NADU | 600083 | - | Rejected-Technical Techncial disqualified |
Tender Value
₹74.3 L
EMD Value
₹1.5 L
Closing Date
17 Sept 2024, 3:00 pmClosed
Chief Engineer, CEG, GSO
GSO Annex building, Kalpakkam - 603102
Automatic Fire Alarm System
2024_GSO_822071_1
GSO/CTC/MSD/79/2024
Open Tender
Miscellaneous Works
Item Rate
240 days
Kalpakkam
As stipulated in NIT/tender
8 documents required · 8 mandatory
₹0
₹1.5 L
22 Jan 2025
21 Aug 2024
18 Sept 2024
21 Aug 2024
17 Sept 2024
30 Aug 2024
22 Aug 2024 - 29 Aug 2024
Amount
Supply Installation Testing and Commissioning of UL 864 and FM approved (or) any equivalent standard 2 Loop IP based Analog addressable Fire Alarm system, having the total panel capacity of 252 devices. The panel shall be able to give location of all fire and More Fire /fault and Isolation conditions of addressable units via the address codes.The panel shall have the capacity of storing upto 10000 events. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel should have inbuilt common Alarm, Fault and monitored sounder output. The panel shall have a built in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries of up to 33 AH capacity. The Panel shall have the capacity of connecting additional 31 panels or Network terminals using network card. The panel shall have the capacity of connecting maximum 16 Remote terminals /16 remote displays or combined by using 2 X RS 485 Card; all as per specification and as directed by Engineer In Charge.
Supply Installation Testing and Commissioning of UL 268 and FM approved (or) any equivalent standard Intelligent Addressable multi-criteria detector (optical and thermal sensors) complete with standard base, facility to mount in different comprehensive environment, Tri-color detector-status LED with 360 ° view, microprocessor circuitry with error check; detector self-diagnostics and supervision programs,Rate-of-Rise Detection: 15°F / min. (8.3°C / min.) - Fixed: 135°F (57°C) , Field programmable as rate-of-rise or fixed temperature, Polarity insensitive, Superior EMI and RFI immunity, RoHS compliant. Detector shall have in-built isolator for better reliability; all as per specification and as directed by Engineer In Charge.
Supply Installation Testing and Commissioning of Thermal Detectors shall be rated at 135°F (57°C) fixed temperature and 15°F (8.3°C) per minute rate of rise. Detectors shall be constructed to compensate for the thermal lag inherent in conventional type detectors due to the thermal mass, and alarm at the set point of 135 °F. The choice of alarm reporting as a fixed temperature detector or a combination of fixed and rate of rise shall be made in system software;all as per specification and as directed by Engineer In Charge
Supply Installation Testing and Commissioning of UL listed Intelligent addressable Class X type (Style 7) Manual Call Point, Single Action, Shock and Vibration Resistant, with built in dual isolator, polarity insensitive, Tri color LED for status (Green for Normal,Yellow for Faulty and RED for activation), T-45 Key Reset lockset for easy maintenance, Operating Temp and RH: 0-49degC and <=95%. MCP shall have in-built isolator for better reliability; all as per specification and as directed by Engineer In Charge
Supply and Installation of micro controller based Auto Dialer (GSM) based module to alert to mobile numbers through speech and SMS dialer; The Auto Dialer shall be capable of communicating to15 different mobile number during emergency call and shall capable of 20 secounds recorded message to the each number shall be communicated for each message; all as per specification and as directed by Engineer In Charge
Supply and Installation of 2Cx1.5 Sq mm Armoured Cable; as per specification and as directed by Engineer In Charge
Removal of old 2C x 1.5 Sq mm armoured cables installed in various location, which includes removing of saddle support present in the cable, filling the removed portion of saddle with putty cement matching to the wall paint; the scope of work also includes removing of detector, Manual Call Point (MCP), sounder present in the loop etc... all complete as per directions and approval of Engineer-in-charge.
Providing Telescopic pole of 4.5 m + 1.13 m along with Detector Removal Tool Kit; Dispenser Kit and Aerosol A10S (Non Flammable) of total 10 Nos; all complete as per directions and approval of Engineer-in-charge.
Providing and fixing double scaffolding system (cup lock type) on the exterior side at all height made with 40mm diameter M.S. tube spaced @ 1.5 m centre to centre at both horizontal and vertical tubes, joining with cup and lock system with M.S.tube, M.S.tube challies, M.S clamps and M.S staircase system in the scaffolding for working platform etc., and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners connection with the building, etc., Wherever required for the inspection of work at required location with essential safety features for the workmen, etc., complete as per directions and approval of Engineer-in-charge. (Note: The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.)
Carryingout IR testing for all the armourced cables installed in the locations irespective of the length of the loop not more than 200 m or 25 detectors; Testing of cables which includes removing the old detector/Manual Call Point/Sounder etc... present in the loop; interconnecting the cable between the detector to ensure the continuity in the cable; measuring the IR values in the loop by using insulation tester resistance meter, all complete as per directions of Engineer-in-charge.
Supply and fixing of 20 mm Cassing and Capping; as per specification and as directed by Engineer In Charge
Supply and Fixing of Glanding on the Panel, Detector, Sounder, MCP along with proper termination; as per specification and as directed by Engineer In Charge
Supply and Laying of 3 core X 2.5 Sq.mm armoured cable; as per specification and as directed by Engineer In Charge
Supply and Installation of 10A 2 pole MCB with back box along with enclosure along with proper termination; all complete as per directions of Engineer-in-charge.
Removal of old existing panel installed in the substation; which includes dismantling of base frame, cables and other accessories; all as per directions and approval of Engineer-in-charge.
Swipe Technologies (BID ID -3079245)
Bidder Name
Swipe Technologies
Equip Resource
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .