Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC 3838 2ND FLOOR SECTOR 46 C CHANDIGARH UT 160047 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160047 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹11.9 L+₹2.2 L (22.4%)Rejected-Finance | L2 | Rejected-Finance VALID BID | |
| 3 | L3₹14.5 L+₹4.8 L (49.1%)Rejected-Finance | L3 | Rejected-Finance VALID BID | |
| 4 | Rejected-Technical BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | - | Rejected-Technical The firm is not enlisted in appropriate category of work |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
19 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, Shimla Hills Jutogh
CWE, Shimla Hills Jutogh, Jutogh Cantt. Shimla-171008
REPAIR/ MAINT OF HT ELECTRIC INSTALLATION AND DISTRIBUTIONS AND OTHER CONNECTED ITEMS AT SUBATHU UNDER GE KASAULI
2022_MES_520795_2
CA NO. CWE/KAS-09 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Subathu
Please Refer as per Tender Documents
6 documents required · 6 mandatory
₹500
GE Kasauli
₹30,000
Yes
4 Aug 2022
10 Jun 2022
21 Jul 2022
10 Jun 2022
19 Jul 2022
24 Jun 2022
Amount
Overhauling of step down outdoor/ indoor transformer 11/0.433 KV (400-750 kVA) by disconnecting HT/LT terminals, decanning transformer oil removing sludge, cleaning of HT/ LT bushings to remove dust particles/dirt etc. Cleaning the core and winding with compressed air and re-assemble complete including replacement of copper windings, copper washers, rubber bushes of HT/LT bushings, replacement of cork sheet of 6 mm thick suitable for transformer top cover, terminal boxes, refilling the transformer oil and toping up with new transformer oil and centrifuging to achieve the dielectric strength upto 50KV, painting with two coats of synthetic enamel paint over a coat of red oxide primer after preparation of painted surfaces of transformer and testing and recommissioning on load etc complete for the transformers of above mentioned rating. (Note :-Dehydration of transformer oil by filtration, topping up transformer oil, shall be measured and paid separately as supply only under respective items).
All as per item No-01 above but capacity of transformer 100 KVA to 250 KVA complete all as specified and directed.
Disconnecting electrical connections of transformer of capacity 400 to 750 KVA of any make & any type, loading the transformer on heavy vehicle (open chassis) type from existing platform/four pole structure, by heavy crane long boom type suitable for shifting and loading transformer and transporting of transformer for repair / rewinding at workshop at Dharampur from Subathu Stn Area including unloading of transformer from vehicle at workshop & Opening up transformer step down 11/0.433 KV by unscrewing all nuts/bolts and washers of top cover duly draining out complete transformer oil and kept aside for re-use. Disconnecting of all HT/LT wiring tap changer, complete LT/HT bushing, air breather etc and kept aside for re-use of the serviceable parts and removal of unserviceable parts and taking out complete core assembly of transformer with help of chain pulley to carry out the following works:
(a) Deslurring of transformer tank by taking out the complete deposited transformer oil sludge and cleaning thoroughly the transformer tank by washing & wiping out all dirt/rust accumulated including preparation of old painted internal/external surfaces of transformer. Painting the internal surfaces of transformer with two coats of high grade anticorrosive varnishing paint over a coat of red oxide primer. Painting to external surfaces of transformer with two coats of 1st grade synthetic enamelled paint over a coat of red oxide primer, all as shown and directed.
(b) Cleaning the transformer core assembly using electric blower and making the core free from sludge, dirt and any other foreign materials from its surfaces including provision of high grade insulation varnish and raising insulation of the core through heat chamber and raising of IR valve /LV-E > 500 Mega ohms HV-E >1000 Mega ohms
(c) Assembling the transformer complete including supply of complete set including replacement of defective accessories such as oil seal, gasket, LT/HT bushing, stud, air breather, tap changer, including making necessary LT/HT wiring as dismantled ( New spares as required will be measured & paid separately under relavent items, rate of oil seal & gasket will be deemed included in the quoted rate). Powering of dehydration/filtered transformer oil (dehydration charges will be measured and paid separately) as obtained during dismantling and top up balance quantum with new transformer oil as required (New transformer oil will be measured & paid under relavent item) after successfully repairing the transformer, reloading the same & placing to its original location and installation complete including making LT/ HT side cable connection, earth connection and testing complete all as specified and directed.
All as per itern No-03 above but capacity of transformer 100 KVA to 250 KVA complete all as specified and directed.
Replacement of worn out copper strip/ wire/ rod as per existing gauge/ size all as specified and directed.
HV Bushing of transformer with Brass metal connecting rod, nut bolt and washer,suitable for 400 KVA to 750 KVA capacity of transformer 11000 Volt as par IS 3347/1967 including taking down the old one complete all as specified and directed.
All as per item No-06 above but capacity of transformer 100 KVA to 250 KVA complete all as specified and directed.
LV Bushing of transformer with Brass metal connecting rod, nut bolt and washer suitable for 400 KVA to 750 KVA capacity of transformer 1100 Volt as per IS 3347/1967 including taking down the old one complete all as specified and directed.
All as per Item No-08 above but capacity of transformer 100 KVA to 250 KVA complete all as specified and directed.
Cork sheet for top cover suitable for 400 to 750 KVA capacity transformers fixed in replacement complete all as specified and as directed
All as per item No-10 above but capacity of transformer 100 KVA to 250 KVA complete all as specified and directed.
Silica gel crystal complete in all type of capacity of transformers fixed in replacement complete all as specified and directed.
Sillica gel breather assembly complete with silica gel crystal fixed in replacement complete for the capacity of transformer 400 KVA to 750 KVA all as specified and directed.
All as per item No-13 above but capacity of transformer 100 KVA to 250 KVA complete all as specified and directed.
Filtration & Dehydration of transformer oil using ON-LINE filtration plant to achieve dielectric strength minimum 50 KV/ 4mm etc complete all as specified and directed.
Supplying filling and pouring of transformer oil conforming to IS 395-1983 having dielectric strength minimum 50 KV/ 4mm including topping up in transformer complete all as specified and directed
Anti-climbing device, spikes type fabricated out of M.S bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole suitable for PCC/Steel poles including two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.
Lightening arrestor expulsion type for out door use complete with all fitting, transmission class discharge capacity 65 KA suitable for 11000 volts including brackets, clamps, nuts and washers and connecting to earth wire 4 mm dia Gl wire fixed in repair complete all as specified.
Disc type insulator, porcelain, vitreous 145mm high and 255mm dia , ball and socket type, white, brown or green, single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts complete all as specified.
Drop out expulsion type fuse with fuse barrels outdoor HT 11KV triple pole mounted on HT 11 KV insulators & MS frame including two coats of aluminium paint over a coat of red oxide primer on MS work fixed in repair complete all as specified.
Switch Air break, gang operated, triple pole, mechanically operated mounted on HT insulators (12 insulators pin type) and MS galvanised steel frame with operating mechanism operated from ground level with fixed contacts of phosphorous bronze and moving contacts of copper including operating rod of current rating upto 200 Amps, 11000 volts complete with locking arrangement, including 3 Nos drop out expulsion type of fuses with fuse barrals of required capacity to suit load at site, also including provision of two coats of aluminium paint over a coat of red oxide primer on MS work complete all as specified and as directed.
Earthing complete with and including galvanised steel earth plate electrode 60 cm x 60cm x 6 mm thick surrounded by mixture of charcoal and salt in alternate layers, buried directly in ground vertically in a pit of depth not less than 2.25 meter deep below ground level with top as of the plate at a depth of not less than 1.5 mtrs below normal ground level connected to equipment by using Gl strips of size 32x6 mm as earthing lead by means of bots, nuts, check nuts and washers of galvanised iron or steel earth wire protected by galvanised steel pipe 15 mm bore (light grade) and 20mm bore 'Light' grade Gl watering pipe connected to main switch or main control board or GOD or lightening arrester all as shown in electrical plate No. 3 of SSR-2009(Pt I) & including necessary excavation and earth work. The rate also include charcoal and salt in alternate layers, 20 mm bore Gl pipe (Light grade) for watering, protection pipe funnel, wire mesh, PCC 1:2:4 type B1 chamber in cement concrete,50 mm thick precast RCC M-25 (Design mix) cover duly reinforced with XPM (weight not less than 3 kg/sqm) and Cl frame etc, and including provision of test point, connecting to test point and testing on completion etc, complete all as specified. NOTE:- The unit rate include earthing lead and protection pipe upto 7.5 metre from top of earth plate.
Galvanised iron strip 32x6mm buried in ground complete all as specified and directed.
taking out existing earthing and M&L for Chemical earthing (Pipe in pipen technology) Two B class IS mild steel pipe, one inside the other, hot dip galvanised with 100 micron coating outside and about 300 micron coating inside filled with high conductive and corrosion Resistant Crystalline Mixture inside and Backfill compound (around the outer electrode), outer electrode dia 72 to 80mm and inner electrode dia 35 to 40 mm, both 10' long, including making earth pit of size 4' x 4' and 11' deep, fill the entire pit with black cotton soil or normal soil, pour enough water so that pit is full with water, leave it for three days so that soil soaks up the water. As the soil level goes down, again top up the pit with soil & fill the water. After two or three days when the pit is sturdy and ready for earthing purpose, install the earthing electrode as per installation method as below:- (a) Mix backfill compound evenly with soil. (b) Remove plastic sleeve carefully from electrode. (c) Place naked electrode at centre of pit (d) Start refilling empty space around electrode with backfill compound in layers. (e) Pour some water and poke the pit with a long wooden rod to allow trapped air to escape (f) Gradually continue refilling process till electrode is buried in the pit up to the green patch painted on the top portion of electrode (g) Ensure that pit is not watery (h) Pack electrode with compound nicely and tightly, so that it stands firmly in pit (j) Pour a few buckets water around pit (k) Pour a few buckets of water around in the pit everyday for 10-15 days for system to set (l) Connect the earth electrode with equipments by 25mm x 3mm aluminium strip (m) Earthing test point terminal block made of gun metal size 150x100x50 mm drilled and screwed including 4 Nos 8 mm dia 40 mm long hexagonal head bolts and washers duly fixed on walls with 4 Nos fasteners . Note: (a) Earth resistance shall not be more than 5 Ohm. (b) Aluminium strip for connections shall be measured and paid separately.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for HT, 25x20 cm size including removing the old ones complete all as specified and directed.
Vasudeva Trading Co.
Ayushmat Contractors
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .