Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.2 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹31.8 L+₹38,508 (1.23%)Rejected-Finance | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹33.0 L+₹1.6 L (5.10%)Rejected-Finance | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹35.0 L+₹3.6 L (11.4%)Rejected-Finance | L4 | Rejected-Finance BEING L4 | |
| 5 | L5₹35.7 L+₹4.3 L (13.7%)Rejected-Finance | L5 | Rejected-Finance BEING L5 |
Tender Value
₹40.7 L
EMD Value
₹81,400
Closing Date
9 Jan 2023, 6:00 pmClosed
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
PROVN OF TILING AND IMPROVEMENT TO CERTAIN MD ACCN AND SR TO BLDG NO P-9 AND P-14 AT AF STN KANHERI HILLS UNDER GE(AF)THANE
2022_MES_565820_1
8237/E8
Open Tender
Civil Works
Item Rate
180 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹81,400
Yes
23 Mar 2023
28 Nov 2022
10 Jan 2023
28 Nov 2022
9 Jan 2023
28 Dec 2022
28 Nov 2022 - 28 Dec 2022
Amount
Demolition of brickwork or stone boulders masonry built in CM incl all quins, arches, pillers etc complete all as specified and as directed by Engr-in-charge.
Taking down cement plaster any description etc incl racking out joints, hacking for key scrubbing down with water complete all as specified and as directed by Engr-in-charge.
Taking down/dismantling loose/damage concrete including plaster of any description and in any position from RCC structures like chajja, fins, louvers, parapet, column, beam, and of lintel by hammering with wooden mallets carefully chipping off the old concrete surface including cutting of rusted reinforcement if so required and disposal of old debris to outside the premises complete all as specified and as directed by Engr-in-charge.
M&L for Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 , complete all as specified and as directed by Engr-in-charge.
M&L for Cleaning the existing surface of concrete and reinforcements as obtained after execution of item No.4, here in before by wire brush including scrapping & cleaning with emery paper and washing down with water as required and applying “Solvent free epoxy concrete bonding agent” as per manufacturer’s instructions on old concrete surfaces for bonding with new concrete complete all as specified & as directed. (water proofing compound shall be measured and paid seperately)
Supply only. Solvant free Epoxy concrete bonding agent,complete all as specified and as directed by Engr-in-charge.Make : Nitobond EP of FOSROC/Carbodur of SIKA/ or equivalent in PEDILITE
M&L for providing reinforced cement concrete (1:1½: 3) type B0 (using 12.5mm graded stone aggregate) mixed with integral water proofing liquid admixture CONPLAST X421IC (Fosroc) or equivalent as per manufactures instructions as in columns, pillars,lintel, slab supported walls roof, landings, balconises, canopies, deck slabs, Chajjas shelves, Fins, fascias, louvres, parapets, and railings, newels, balustrade, and the like etc including necessary form work and scaffoldings up to 2 story of building ,complete all as specified and as directed by Engr-in-charge.
M&L for Pre-cast cement concrete block masonry 1:3:6 Type C-1 (using 20mm graded aggregate)with solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and as directed by Engr-in-charge.
M&L for rendering 15mm thick in CM 1:6 on fair faces of brick work or concrete surfaces of wall and finishing the surface even and smooth without using extra cement ,complete all as specified and as directed by Engr-in-charge.
M & L for rendering 20 mm thick (15 mm thick in cement mortar 1:6 as backing coat and 5mm thick in cement mortar 1:4 as finishing coat) on fair faces of brick work or concrete surfaces including finished even and smooth without using extra cement with using water proofing compound (water proofing compound shall be measured and paid seperately) ,complete all as specified and as directed by Engr-in-charge.
Supply only integral water proofing compound ,complete all as specified and as directed by Engr-in-charge. .
M&L for rendering 5mm thick in CM 1:4 on fair faces of concrete as in ceiling of slab finished even and smooth without using extra cement ,complete all as specified and as directed by Engr-in-charge.
M&L for rendering 5mm thick in cm 1:3 on fair faces of concrete as in soffit ceiling of slab, chajjas finished even & smooth without using extra cement ,complete all as specified and as directed by Engr-in-charge.
M&L for preparing new plastered surfaces and applying two coat of OBD over a coat of alkali resistant priming paint ,complete all as specified and as directed by Engr-in-charge.
M&L for preparation of newly plasterd surface of concrete or brick surfaces and applying Two coats ( having proportion @1.67 Litr/10 Sqm) of acrylic smooth exterior paint of required shade and including priming coat of exterior primer applied @ 2.20 Kg / 10 sqm, complete all as specified and as directed by Engr-in charge.
M&L for Preparing new plastered surfaces of ceiling and applying two coats of white wash ,complete all as specified and as directed by Engr-in-charge.
M&L for washing,rubbing down and stopping of distempered of old painted surfaces of wall and applying Two coats ( having proportion @1.67 Litr/10 Sqm) of acrylic smooth exterior paint of required shade and including priming coat of exterior primer applied @ 2.20 Kg / 10 sqm, complete all as specified and as directed by Engr-in charge.
M&L for washing, rubbing down and stopping of distempered and painted surfaces of wall and applying one coat of distemper oil-emulsion on walls ,complete all as specified and as directed by Engr-in-charge.
M&L for preparation of old decorated cement plastered surfaces of ceiling and applying of one coat of white wash ,complete all as specified and as directed by Engr-in-charge.
M&L preparation of old painted steel surface & applying a coat of synthetic enamel paint ,complete all as specified and as directed by Engr-in-charge.
Taking down chowkats or frames with shutters (without taking off shutters form frame) . exc 1.5 sqm & n.exc 4 sqm each ,complete all as specified and as directed by Engr-in-charge.
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each and removing to store ,complete all as specified and as directed by Engr-in-charge.
Taking down shutters of any description n.exc 1 sqm each and removing to store ,complete all as specified and as directed by Engr-in-charge.
Taking down chowkats or frames with shutters (without taking off shutters form frame) n. exc 1.5 sqm each ,complete all as specified and as directed by Engr-in-charge.
S&F IInd class hard wood plain, solid, straight chowkat and frame wrought framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints ,complete all as specified and as directed by Engr-in-charge.
S&F for 35mm thick IInd class HW rail and style plain framed panelled factory made shutter (Two panel) with lock rail and panel of 9mm BWP,commercial ply or 12mm veneered particle beard with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part-I) kiln and chemically pressure treated ,complete all as specified and as directed by Engr-in-charge.
S&F for 35mm thick IInd class hard wood glazed and skelton shutters divided into squares with plain chamfered or reounded miltred and related sash bars number to received glass gauze etc edges of framing plain chamfered or reounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified in SSR Part-I section 8 clause 8.20(a) supplied and fitted to chawkats ,complete all as specified and as directed by Engr-in-charge.
M&L for 25 x 3mm FI holdfasts for fixing door frame ,complete all as specified and as directed by Engr-in-charge.
M&L for Cutting holes in brick walls exc half bricks but nexc one brick built in cement mortar or cement lime mortar for inserting holdfasts and making good dismantled portion in cm (1:3) or cement concrete (1:2:4) type B1 as required ,complete all as specified and as directed by Engr-in-charge.
M&L for preparation of new wood surfaces of any description over 10cm width of girth applying two coats of synthetic enamel paint over coat of pink primer etc ,complete all as specified and as directed by Engr-in-charge.
M&L for preparation of old wooden surfaces of any description over 10cm width & girth not otherwise described and applying a coat of synthetic enamel paint ,complete all as specified and as directed by Engr-in-charge.
S&F Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) 250mm length and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed all as specified.
S&F aluminium anodized barrel tower bolt extruded section and fixed 200mm long ,complete all as specified and as directed by Engr-in-charge.
S&F Floor door stopper 150mm length of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor ,complete all as specified and as directed by Engr-in-charge.
S&F extruded aluninum alloy handles, fabricated type anodized 150mm long ,complete all as specified and as directed by Engr-in-charge.
S&F butt hinges, medium weight, cold rolled mild steel, of size 100mm ,complete all as specified and as directed by Engr-in-charge.
S&F mild steel 300mm ordinary rat tail rod pettern springs including roller and roller plate,complete all as specified and as directed by Engr-in-charge.
M&L for Hacking out old broken glass (any thickness, size, quality or description) from alluminium/wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads exc 1.5 sqm
S&F sheet glass ordinary quality 3.00mm thick and glazing with oil putty or aluminium/rubber beading in squares n.exc 0.5 sqm in each pane ,complete all as specified and as directed by Engr-in-charge.
S&F figured glass, pin-headed type 3.00 mm thick and glazing with oil putty or aluminium/rubber beading in squares n.exc 0.5 sqm in each pane ,complete all as specified and as directed by Engr-in-charge. .
S&F aluminium anodised frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc.,complete all as specified and as directed by Engr-in-charge.
S&F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples ,complete all as specified and as directed by Engr-in-charge. .
S&F for providing and fixing zinc alloy roller for sliding window/ aluminium sections with necessary screws etc. ,complete all as specified and as directed by Engr-in-charge.
S&F for Zinc alloy (powder coated) casement lock for windows with necessary screws etc ,complete all as specified and as directed by Engr-in-charge.
Repairs to shutters of any description easing & adjusting without taking down area exc 1 sqm but n. exc 2 sqm ,complete all as specified and as directed by Engr-in-charge.
S&F solid PVC solid door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling and fixing in opening with stainless steel screws of required size ,complete all as specified and as directed by Engr-in-charge.
S&f factory Made Solid PVC Moulded Door Shutter,with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing. Including 3 Nos of stainless steel 100 mm size hinges, 2 Nos of aluminium 100 mm size handles, 2 Nos of aluminium tower bolt 100 mm size ,complete all as specified and as directed by Engr-in-charge.
Dismantling water tank capacity exc 500 and n exc 1000 ltr and removing to store all as directed ,complete all as specified and as directed by Engr-in-charge.
S&F1000 Ltr Rotational moulded polyethene water storage tanks (Cylindrical vertical with closed top) hoisted and fixed in position,complete all as specified and as directed by Engr-in-charge.
S&F in repair 20mm Ball valves, high pressure of PTMT with epoxy coated aluminium rod & highdensity plastic ball screwed for iron pipe and fixed (Min. weight 20mm-210gms ,complete all as specified and as directed by Engr-in-charge.
S&F in repair 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe or for unions and fixed,complete all as specified and as directed by Engr-in-charge.
Taking down steel tubing & connections incl cleaning for refixing or removal to store for 15mm bore of pipe ,complete all as specified and as directed by Engr-in-charge.
Taking down steel tubing & connections incl cleaning for refixing or removal to store for 25 or 32 mm bore of pipe ,complete all as specified and as directed by Engr-in-charge.
M&L for 15mm bore medium grade G.I tubing with all fittings & fixed complete to walls & ceilings or laid in floors ,complete all as specified and as directed by Engr-in-charge.
M&L for 25 mm bore medium grade G.I tubing with all fittings & fixed complete to walls & ceilings or laid in floors ,complete all as specified and as directed by Engr-in-charge.
Dismantling cast iron drain pipes of any description ,complete all as specified and as directed by Engr-in-charge.
S&F of 100 mm bore cast iron (Sand cast pipes) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall with MS clamp ,complete all as specified and as directed by Engr-in-charge.
S&F of 75 mm bore cast iron (Sand cast pipes) soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall with MS clamp ,complete all as specified and as directed by Engr-in-charge.
S&F of 100 mm bore cast iron (Sand cast pipes) soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors with MS clamp ,complete all as specified and as directed by Engr-in-charge.
S&F of 75 mm bore cast iron (Sand cast pipes) soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors ,complete all as specified and as directed by Engr-in-charge.
S&F of Cast Iron floor trap, 75mm dia out let with grating including jointing to waste pipe fixed in cement concrete (1:2:4) type B1 including taking down old floor trap ,complete all as specified and as directed by Engr-in-charge.
S&F of CI bends of 100mm dia fitted with oval access doors,complete all as specified and as directed by Engr-in-charge.
S&F of CI bends of 75 mm dia fitted with oval access doors ,complete all as specified and as directed by Engr-in-charge.
S&F of CI branch pieces "T" or "Y" type 100mm dia ,complete all as specified and as directed by Engr-in-charge.
S&F of CI branch pieces "T" or "Y" type 75 mm dia ,complete all as specified and as directed by Engr-in-charge.
S&F in repair CI cowl of 100mm dia ,complete all as specified and as directed by Engr-in-charge.
S&F in repair CI cowl of 75 mm dia ,complete all as specified and as directed by Engr-in-charge.
S&F in repair cast iron Nahani trap of 100mm dia including jointing to waste pipe fixed in cement concrete type 1:2:4 type B1 ,complete all as specified and as directed by Engr-in-charge.
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to stone and rubbish of the premises ,complete all as specified and as directed by Engr-in-charge.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite ,complete all as specified and as directed by Engr-in-charge.
M&L for machine cut cudappah stone slab 20-25mm thick over cement screed base, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20mm thick screed bed in CM 1:4 for laying floor finishes ,complete all as specified and as directed by Engr-in-charge.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (squre or rectangle) area of each tile exceeding 0.11 Sqm but not exce 0.18 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick screed bed or bedding layer in CM(1:6) ,complete all as specified and as directed by Engr-in-charge.
M&L for glazed ceramic tiles in vertical surface 350x 250x 7mm/ 450X 350X 7mm thick in skirting/dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tiles over and including 10mm thick rendering in CM(1:4) ,complete all as specified and as directed by Engr-in-charge.
M&L for Non-skid Ceramic coloured joint free tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 for laying floor finishes ,complete all as specified and as directed by Engr-in-charge.
Demolition of concrete of any description and in any position not otherwise specifically provided all as specified and directed by Engr in Charge.
M&L for 50 mm thick PCC type C-2, 1:3:6 using 40mm graded stone aggregate as in plinth protection finishing surfaces of concrete even and fair (without using extra cement), ,complete all as specified and as directed by Engr-in-charge.
M&L in repairs orrisa pattern viterious china ware water closet white glazed of pan size 580x440mm with integral foot rest fixed flushed pipe including all joints and making good to the floor ,complete all as specified and as directed by Engr-in-charge.
S&F in repair low level flushing cistern plastic valve less syphonic action type white with inlet ball valve float and ball handle & capacity 10 ltr ISI marked including 32mm PVC flush pipe ,complete all as specified and as directed by Engr-in-charge.
S&F in repair vitreous china wash hand basin white flat back size 550 X 400 mm excluding taps waste chain and plug and porcelain stopper but including brackets, waste coupling and waste pipe complete all as specified and directed.
S&F wash basins, vitreous china (under counter oval type) of size 580 x 415 x 190 mm including fixed to granite with cement including waste coupling and waste pie etc. ,complete all as specified and as directed by Engr-in-charge.
S&F in repairs brass cromium plated shower rose with swivel joint 125 mm size ,complete all as specified and as directed by Engr-in-charge.
S&F in repairs bib tap 15mm bore chromium plated cast copper alloy with crutch or butter fly handle but fancy type screwed down screwed for iron pipe ,complete all as specified and as directed by Engr-in-charge.
S&F in repairs PVC connections 15mm dia with brass nut on both ends and washers 450mm long ,complete all as specified and as directed by Engr-in-charge.
S&F in repairs quarter turn CP Brass fancy type stop valves/angle valves screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe 15mm dia ,complete all as specified and as directed by Engr-in-charge.
S&F 15mm dia pillar tap chromium plated cast copper alloy with capstan head, fancy type screwed down high pressure with or with out letters Hot or cold with long screwed for iron pipe ,complete all as specified and as directed by Engr-in-charge.
S&F Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; grating and Union for discharge pipe ,complete all as specified and as directed by Engr-in-charge.
Demolition of reinforced cement concrete manually/ by mechanical means including disposal of unserviceable debris, rubbish and building material outside of MoD Land at a suitable stacking location at ground level including all lead & lifts as per direction of Engineer-in-charge without disturbing the other structural elements ,complete all as specified and as directed by Engr-in-charge.
Removal of existing concrete including loose/weak concrete from the concrete structure i.e. beams/columns/deck slab etc upto beyond corroded steel reinforcements to a depth of 10mm minimum behind the reinforcement by chipping/hacking with chisel and hammer or by mechanical means like chisel hammer, pneumatic chippers including high pressure water jetting and removal of debris. Concrete around the corroded reinforcement shall be removed properly. The edges of the repair locations of concrete should be saw cut to depth of at least 10mm to avoid feather edging and to provide a square edge complete all as specified and directed by Engr-in- Charge. (Quoted rate includes necessary form work and scaffoldings including supports to structures design rehabilitation upto 2 story of building)
M&L for Preparation of surface and removal of rust in the loosely bonded concrete of the RCC deck slab, beam / girder and piles shall be chipped out using the mechanical cutter exposing the bars and applying Rust Remover using small brush and allow to react it for 16-24 hrs. Before applying protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth complete all as per manufacturer instructions and directed by Engr- in- Charge. (Quoted rates to include necessary form work and scaffoldings alongwith support to structures undergoing rehabilitation upto 7 meters height)
M&L for applying two coats of Anti-Corrosive Primer two component (epoxy anticorrosive zinc rich coating) on reinforcement steel surfaces uniformly. Coating shall be applied by the brush to the exposed and cleaned rebars with an interval of 45 minutes to 1 hour @ 40microns DFT / coat and allowed to completely dry for 24 hours complete all as per manufacturer instructions and directed by Engr- in- Charge. (Quoted rates to include necessary form work and scaffoldings alongwith support to structures undergoing rehabilitation upto 7meters height)
M&L Drilling holes at interval of 600mm for grouting and providing and inserting Rohibb Nylon nipple (10mm or12mm) with approved fixing compound as per technical specifications including cutting V groove in cracks making the crack dust free by blowing compressed air and then washing with water, sealing the distance between the injection nipples with approved epoxy putty and allow it to cure, including necessary scaffolding, form work complete all as specified and as directed by Engr-in-Charge. (Quoted rates to include necessary form work and scaffoldings alongwith support to structures undergoing rehabilitation upto 7meters height)
M&L for Providing and Injecting the fixed packer two-component low viscosity (<350 cps) epoxy resin system that achieves compressive strength in excess of 55 MPa at 1 day & 65 MPa at 7 days. and shall exceed 15 MPa in slant shear bond strength with minimum pot life of 30 minutes at ambient temperatures complying with ASTM C881, Type 1 & 4, Grade 1, Class B &C using any of the standard pressure grouting methods at a maximum pressure of 2kgs/sq.cm till refusal and allowing the epoxy grout to cure before removal of packers inclusive of cost of material, manpower and equipment. (Quoted rates to include necessary form work and scaffoldings alongwith support to structures undergoing rehabilitation upto 7meters height)
M&L for holes of dia 16mm and depth 100 mm drilled @ a spacing of 1mtr c/c on the existing structure. The loose cementitious particles are removed using air blower to clean the holes. Shear Keys of dia 10mm cut from HYSD rebars are anchored into these holes of depth 75mm and bent out to an equal length of 75mm using Resin Anchor Grout complete all as per manufacturer instructions and directed by the Engr-in- Charge. (Quoted rates to include necessary form work and scaffoldings alongwith support to structures undergoing rehabilitation upto 7meters height)
M&L for providing fabricating & fixing in position Tor steel TMT bar 10mm dia and over reinforcement conforming to IS 1786 of 1985 (third revision) code specifications including cutting, bending placing as per IS 2502:963 at any position / level with 0.9mm dia annealed binding wire also including wastages etc. all complete as specified and directed
Drilling and fixing following diameter of bar for re-bars with 'Fischer/Hilti' system and chemical, etc. (Steel to be measured and paid separately) (Quoted rates to include necessary form work and scaffoldings alongwith support to structures undergoing rehabilitation upto 7 meters height)
(a) for 16 mm bar
(b) for 10 mm bar
M&L for preparation of concrete surfaces by removing loose concrete, dust, dirt etc, cleaning the surface properly and applying one liberal coat of epoxy bonding agent (two component agent) by brush application complete all as per manufacturer instruction and directed by Engr-in- Charge. (Quoted rates to include necessary form work and scaffoldings alongwith support to structures undergoing rehabilitation upto 7meters height)
M&L for Providing formwork to sides of floor/roof beams, pillars, posts, struts, piers, columns to pour the micro-concrete /concrete using steel shutters or 12mm marine ply to have the form finish including de-shuttering, scaffolding, steel tubular props and necessary items etc complete all as specified and as directed by Engr-in-Charge.
M&L for micro concrete to existing concrete structure including proper tight leak proof shuttering SPL polymer modified cementitious, low permeable 'free flow' non shrink self-compacting micro concrete shall be grade M70 as per recommended w/c ratio and pouring as per the required thickness complete all as per manufacturer instructions and directed by Engr- in- Charge. (Quoted rates to include necessary form work and scaffoldings alongwith support to structures undergoing rehabilitation upto 7meters height)
M&L 50mm thick (average thickness) modified single component, alkaline resistant fibre reinforced, thixotropic, cementitious patch repair mortar on concrete structure. Applying the mortar around the reinforcement and finishing to bring it in line with existing concrete surface complete all as per manufacturer instructions and directed by the Engr-in- Charge. (Quoted rates to include necessary form work and scaffoldings alongwith support to structures undergoing rehabilitation upto 7meters height)
M&L for Cutting chases, pinning in, making good to facings on stone concrete block or slab walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for inserting/concealed roofing sheets etc. and making good cutting exceeding 20cm girth as specified and directed.
S&F MS Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates (Fe 410-W (Gde-E- 250) quality-A) as specified and directed.
M&L for Pre-painted galvatume aluminum zinc coating GI based curved/plain corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified and directed.
M&L for preparation of new steel surfaces of any description over 10 cm in width or girth not otherwise described and apply two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed
M&L complete removal of existing treatment on brick or concrete wall , washing down with bio wash and cleaning the surface from all loose dirt chalk grease fungi, algae flakes and applying two coats of acrylic paint weather proof exterior grade with camouflage pattern over a coat of primer complete all as specified and directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc.complete all as specified and as directed.
Material and labour for brushing neat cement slurry with 3.0kg of cement per sq. metre complete all as specified and as directed.
M&L for Virified Ceramic tiles 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in CM 1:6 for laying floor finishes complete all as specified and directed.
M&L for Vitrified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in vertical position as dado/skirting. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thck in CM 1:4 as backing coat to receive tiles complete all as specified and directed.
Taking down shutters of size exc 1 sq. m and n exc 2 sq. m each and refixing in the same opening including necessary adjustment after laying of floor tiles complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed (Make : Cera, Kohler, Marc or equivalent)
S&F CP Two-way Bib taps, 15mm dia of bore cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to pipe as specified and directed (Make : Cera, Kohler, Marc or equivalent)
M&L for rendering on other than fair faces of brick work or block masonary surfaces 15mm thick in CM 1:4 and to be finished even and smooth with out using extra cement complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5cu.m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in hard/dense soil complete all as specified and directed.
M&L for cement concrete Type C2 1:3:6 (40 mm graded aggregate) in foundations, columns, pillars, post holes filling and mass concrete including caps and bases as specified and directed.
M&L for Cutting holes into or through brick walls built, in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required Superficial area Exc.150 sq. cm but n exc 400 sq. cm as specified and directed.
S&F MS Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. (Fe 410-W (Gde-E- 250) quality-A) as specified and directed
Removing existing water proofing treatment where so ever exist (except concretepadding) and removing debris/rubbish off the site ,complete all as specified and as directed by Engr-in-charge.
Demolition of cement concrete of any description and in any position provided as in roof padding, roof curb etc complete all as specified and as directed. Note: - (a) Demolition should be done carefully to roof slab. (b) Any damage occurred in the roof surfaces during demolition shall be made good by the contractor without extra cost to the department. (c) Disposal of debris/retrieved materials shall be thrown out of site at place as directed.
M&L for providing PCC type B- 1, (1:2:4) using 20mm graded stone aggregate as in roof padding laid in slope as per requirement mixed with integral water proofing liquid admixture as per manufacturer's instructions complete all as specified and as directed. Note : (i) Minimum thickness of PCC shall be 50mm. (ii) Integral water proofing liquid admixture shall be measured and paid separately under appropriate item here in after
Supply only integral water proofing compound.
Labour only of taking up or down steel tubing and connections of 25 to 32mm bore of pipe including cleaning and refixing in the same position as in roof /walls, etc during carrying out of water proofing treatment without damaging to existing services, etc. all as specified and directed.
Labour only for disconnecting existing over head tanks of capacity exc.500 and n.exc 1000 ltr, setting aside or lowering if required for repair of roof water proofing treatment and hoisting, reconnecting and re-fixing in position after necessary work without damaging to existing services etc. all as specified and directed.
Material and labour for water proofing treatment with APP (Minimum thickness of APP membrane 3.00mm ) based standard membrane over PCC padding in roof with the following courses of treatment for:- (a) Apply bituminous primer (IS 3384) @ 0.40 Kg per sqm of the surface area including cleaning the surfaces complete all as specified. (b) Apply APP plastomeric bitumen based mineral finished water proofing membrane polyester reinforced(4 Kg/Sqm) with 10cm over laps and torch bonded at joints including surface preparation before and after application of treatment as per manufactures instruction complete all as specified. (Make of APP Membrane: Moply FP 3 mm mineral of TEXA/WP Shield 103 PM of SIKA or Equivalent material of BITUNIL/BITUMAT. (c) Over the membrane provide a solar reflective bituminous aluminium paint @ 0.1 kg/sqm prescribed by manufacturer complete all as specified.
M&L 25mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in sub-floors, sub-bases, floors and pavings, etc. as specified and directed
M&L for chequered cement concrete tiles (reflective type) with mixture of white and grey cement in equal proportion and no pigments of size 30cmx30cmx25 mm thick, set, jointed and pointed in neat cement surry in floors including 20 mm thick screed bed in CM 1:6 for laying floor tiles complete all as specified and diected.
M&L for Plain cement concrete 1:2:4 type B-1, (using 20 mm graded stone aggregate) as in bed blocks, coping, benching and similar work including necessary form work complete all as specified.
Taking down Point Wiring (Light, Fan, Socket or Power) of any type on Batten/ PVC Casing & Caping or in Conduit with Fittings and Fixture such as Switches, Ceiling Roses, Pendants, Regulators, Sockets, Light Fitting, etc. including necessary Chase cuttings on Brick Walls, Ceilings, Floors, etc. to remove Conduit, etc., complete all as specified and as directed.
Taking down/out unserviceable Wires from the existing Sub-main Wiring of any type and any description, complete all as specified and as directed.
Taking down the existing unserviceable Main Switch/ Cut out/ DBs of any type/ capacity and any description as existing at Site including Making Good the Disturbed Surfaces of Walls, Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed.
Material and labour for point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed multistranded copper conductor cable 1100 volts drawn through and including concealed PVC rigid conduit medium grade, pipe hooks, elbows, junction covers and junction boxes terminated in existing modular steel terminal boxes made out of 1.6mm thick MS sheet concealed in walls including cutting chases in walls for conduits and making good disturbed surfaces of wall in CM 1:3 for mounting switches, sockets, fan regulator, covered with including 3mm thick bakelite plastic laminated sheet top cover fixed flush with wall using brass screws & cup washers including 1.5 Sqmm PVC insulated solid copper conductor wire as earth continuity to common earth and connecting to earth dully for following points controlled by one switch complete all as specified and directed by Engineer-in-Charge.
All as per item No.133 here-in-before but for one five pins 5 Amps switch socket outlet point on same board complete all as specified and directed.
All as per item No.133 here-in-before but for ONE 3 PIN SOCKET OUTLET 6 AMP ON THE INDEPENDENT BOARD, complete all as specified and as directed.
Material and labour for point wiring with 2.5 Sqmm (nominal area) PVC insulated unsheathed stranded copper conductor FRLSH cable 1100 volt grade (ISI marked) drawing into and including non-metallic rigid PVC concealed conduit (medium quality ISI marked) with all fittings such as tee/bends etcterminated in new MS box and fixing new bakelite sheet as top cover and including 1.5 Sqmm single core PVC insulated copper conductor solid earth wire to common earth and connected to earth dully for one power point independent complete all as specified and directed Engineer-in-Charge.
M&L in replacement of Sub-main Wiring with 2-Runs of 4 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 4 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty along with the Wiring drawn in EXISTING CONDUIT/PVC CASING & CAPING, complete all as specified and as directed. Note : (i) Three length of wire along with conduit will be measured as one Length.
M&L in replacement of Sub-main Wiring with 2-Runs of 6 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLSH multi-stranded Single Core Copper Conductor Cable and 1-Run of 6 Sqmm (nominal area) 1100 Volt, PVC insulated unsheathed FRLS multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuty along with the Wiring drawn in EXISTING CONDUIT/PVC CASING & CAPING, complete all as specified and as directed. Note : (i) Three length of wire along with conduit will be measured as one Length.
S&F in replacement of Switch Piano 6 Amp, Flush type, Single Pole, 1-way, complete all as specified and as directed.
Supply and Fix in replacement of switch socket combination 2 in 1,6 pin, 5/15Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Socket Outlet 6 Amp, Piano, Flush type, 2-in-1, multi-purpose, 5 Pin, complete all as specified and as directed.
Supply and Fix in replacement of switch socket combination 2 in 1,5 pin, 5 Amps flush type 220 V ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of Ceiling Rose, 3 Terminals, PVC Polycarbonate, Isolated body complete all as specified and as directed.
Supply and Fix in replacement of fan regulator Electronic type step type for 400 watts ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of lamp holder,PVC/Polycarbonate type with back plate suitable for batten fitting ,complete all as specified and as directed by Engr-in-charge.
Supply and fix LED lamp 7 Watt complete all as specified and directed by Engineer-in-Charge.
Supply and Fix in replacement of Decorative Ultra Slim Linear MIrror LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 5 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting, complete all as specified and as directed.
Supply and Fix in replacement of Decorative Ultra Slim Linear LED Lighting Fixture with Extruded Polycarbonate, Environmental Friendly, Energy Efficient 18 Watt LED 6000K and connecting up with and including Copper Conductor Cable of size 23/0.076 multi-stranded, 3 Core from Ceiling Rose to Light Fitting, complete all as specified and as directed.
S&F in replacement flush mounting factory made SPN DB 8 way, 240 Volt, Double door, IP-43 protection, IK-09 with metal door with 100 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB 6 to 32 Amps, Single Pole 240 Volts, 10 KA, ‘C’ Curve, complete all as specified and directed by Engineer-in-charge.
S&F in replacement MCB, Single Pole & neutral, 40 Amps 'C' Curve having breaking capacity 10 KA complete all as specified and directed by Engineer-in-Charge.
S & F in replacement of Loadline Distribution board, TP&N vertical ,with Bus bars, 160 A, 415V Netural links,blanking plates, double door 4 way, with MCCB 63 Amps as incommer and SP/DP/TP MCB as outgoing and electrically connecting up ,complete all as specified and as directed by Engr-in-charge.
S&F in replacement of sheet metal plug & socket DB, SP, with a two pin and earth plug with socket, 230 Volts with & including one MCB SP ‘C’ Curve 10 kA, 20 Amps complete all as specified and directed by Engineer-in-charge.
S&F in replacement of the Exhaust fans, heavy duty, copper wound,steel body & frame, single phase, 230 volts size 380mm sweep with lower shutter complete all as specfied and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.Note:1.After completion if test results are nor satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing.
Vinod Enterprises
M/S VISHRANTA CONSTRUCTION
Shree Gajanan Enterprises
Nissan Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .