| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC NO 12 5TH B CROSS SHARADAMBA NAGAR M E S ROAD BANGALORE 560013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹15.3 L+₹1,440.20 (0.09%)Rejected-Finance NO 439 AHIV ADAN 11ND FLOOR 2RD STAGE INDIRA NAGAR BANGALORE 560 075 | BENGALURU URBAN | KARNATAKA | 560075 | L2 | Rejected-Finance Rejected Quoted rates are higher than L1 | |
| 3 | L3₹16.7 L+₹1.4 L (9.25%)Rejected-Finance NO 83 THAMMAIAH GARDEN ABBIGERE CHIKKABANAVARA PO BANGALORE 560 090 | BENGALURU URBAN | KARNATAKA | 560090 | L3 | Rejected-Finance Rejected Quoted rates are higher than L1 | |
| 4 | L4₹16.8 L+₹1.5 L (9.83%)Rejected-Finance | L4 | Rejected-Finance Rejected Quoted rates are higher than L1 | |
| 5 | L5₹17.5 L+₹2.2 L (14.5%)Rejected-Finance | L5 | Rejected-Finance Rejected Quoted rates are higher than L1 |
Tender Value
Refer Docs
EMD Value
₹38,000
Closing Date
4 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer M AF Jalahalli
Garrison Engineer M AF Jalahalli BANGALORE 560013
8533REPAIRS AND MAINTENCE OF LT DISTRIBUTION SYSTEM IN DOMESTIC AREA OF AFS JALAHALLI UNDER AGE E M WEST OF GE M AF JALAHALLI BANGALORE
2020_MES_398182_2
8533E8
Open Tender
Electrical and Maintenance Works
Item Rate
303 days
Garrison Engineer M AF Jalahalli
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Garrison Engineer M AF Jalahalli
₹38,000
7 Jul 2021
18 Jan 2021
6 Feb 2021
18 Jan 2021
4 Feb 2021
23 Jan 2021
18 Jan 2021 - 21 Jan 2021
60 days
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr in width and not exceeding 1.5 mtr in depth for laying of cables up to proper level complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and exceeding 1.5M and not exceeding 3 meter in depth for foundation of poles and getting out in soft/loose soil
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed
Removing surplus excavated material from excavation not exc 50 meter and depositing where directed at a level not exc 1.5 meter above the starting point complete all as specified and directed.
Spreading ribbed soil in trenches as in cable cushioning all as specified in IS 1255- 1983 and as directed. Note:- (i) Excavated soil shall be ribbed by using sieve to sepsrate composite particls etc as per IS and refilling in trenches before laying of cable 8CM and 15CM after laying of cable. (ii) For the purpose of measurement punned thickness of 18CM shall be considerd for the payment
Material and labour for well burnt as class ‘B’ bricks as mechanical protection to under ground cables laying with length of the bricks equal to the width of the trench complete all as specified and directed.
Material and labour for cutting of bituminous road/ hard standing/PCC path/wall up to a size of 450mmX150mm for laying of protection pipe for cable including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1, 40 mm grade crushed stone aggregate up to existing surface level or removing the any type of tiles carefully and refixing properly as per existing surface complete all as specified and as directed.
Taking down of unserviceable cable 120Sqmm 3½ core laid in trenches or in duct/passed through pipes or fixed to wall/poles etc crosectional area of size complete all as specified and directed.
All as per item No 08 but 95 Sqmm 3½ core
All as per item No 08 but 70 Sqmm 3½ core
All as per item No 08 but 50 Sqmm 3½ core
All as per item No 08 but 35 Sqmm 3½ core
All as per item No 08 but 25 sqmm 4 core
All as per item No 08 but 16 Sqmm 4 core
All as per item No 08 but 10 Sqmm 2 core
Supply, laying, jointing & testing, XLPE insulated, armoured, heavy duty electric LT UG cable 120Sqmm 3½ core with multi stranded aluminium conductor, 1100 volts grade laid in trenches or in duct/passed through pipes or fixed to wall/poles etc cross sectional area of sizes complete all as specified and directed.
All as per item No 16 but 95 Sqmm 3½ core
All as per item No 16 but 70 Sqmm 3½ core
All as per item No 16 but 50 Sqmm 3½ core
All as per item No 16 but 35 Sqmm 3½ core
All as per item No 16 but 25 sqmm 4 core
All as per item No 16 but 16 Sqmm 4 core
All as per item No 16 but 10 Sqmm 2 core
Supply and fixing in replacement of 40 mm dia GI tubing light grade fixed on walls / laid in trenches as protection pipe for under ground cable including provisioning of specials and clamps etc complete all as specified and directed .
All as per item No 24 but 50 mm dia
All as per item No 24 but 80 mm dia
All as per item No 24 but 100 mm dia
Boring of holes under road, pavement hard standings by trenches technology using ultra sound technique and necessary machine including HDPE pipes of 80 mm dia suitable for 0.4 Mpa working pressure complete all as specified and directed.
Servicing to LT panels/Feeder pillar boxes/APFC Panels comprising MCCBs/switch disconnector fuses/change over switches metering eqpt etc. as incoming/outgoing controls including cleaning, checking the serviceability of individual items, identification of the defective parts replacing the worn-out fasteners, insulators, rubber door beadings, gaskets etc. complete all as specified and directed. Note :- Unserviceable parts replaced shall be measured & paid separately under respective item Sl Nos: 30 to 43 as supply only
Supply only LED indication Lamps for R,Y,B Phase
Supply only Push Button Switches (Red and Green, in Colour)
Supply only Digital Voltmeter moving coil rectifier type 0 to 500Volts.
Supply only Digital Ammemeter 5A direct 3½ digit display accuracy class 1any range
Supply only Digital Power Factor meter any range 1A/5A and 110/230V with built in transducer Accuracy class ±20
Supply only Indoor resin cast ring type low tension current transformer 5/5A to 75/5A 15VA burden accuracy class 1 confirming to IS 2705 /1992
Supply only Indoor resin cast ring type low tension current transformer 100/5A to 200/5A 15VA burden accuracy class 1.
Supply only Microprocessor APFC relay 8 stage with intelligent computer 415 volts, 5 Amp CT Rating, 3 phase 3 wire 50 HZ.
Supply only Microprocessor APFC relay 6/7 stage with intelligent computer 415 volts, 5 Amp CT Rating, 3 phase 3 wire 50 HZ.
Supply only time delay timer 1-30 sec.
Supply only MPP Standard Duty Capacitors Cylindrical type of Rating 5 KVAR.
Supply only MPP Standard Duty Capacitors Cylindrical type of Rating 10 KVAR.
Supply only MPP Standard Duty Capacitors Cylindrical type of Rating 20 KVAR.
Material and labour for rewiring the LT panels/Feeder pillar boxes/APFC Panels by means of PVC insulated multi strandard copper wire of existing size including replacing unserviceable connectors, fastners etc, etc after taking out the old unserviceable wiring complete all as specified and directed. Note:- Material / items listed under item No 45 to 48 shall be measured and paid as supply only.
Tubular solar battery 12V 75AH.
LED street light DC luminaire
Panel circuit board.
Electrolyte for Existing battery
Supply and fixing street light terminal boxes factory made, made out of 2.0 mm thick PVC sheet, powder coated with hinges and door with locking arrangements of size 300 x 250 x 150 mm housing in and including 25x3 mm bus bar 04 Nos of suitable length fixed on porcelain insulator with proper size of screw and one No of MCB SP 6 Amps, 240 Volts, in/out cable gland of suitable size of cables complete fixed on street light pole with clamp/bracket, nuts, bolts and washers etc complete all as specified and directed by Engr-in-charge.
Supply only MCCB 4 pole 25-32A 16KA - in LT panel boards / feeder pillar boxes including disconnecting and removing existing from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model, all as specified and as directed.
All as per item No 50 above but of size 40-50A 16KA
All as per item No 50 above but of size 63-80A 16KA
All as per item No 50 above but of size 80-100A 16KA
All as per item No 50 above but of size 100-125A 25KA
All as per item No 50 above but of size 160-200A 25KA
All as per item No 50 above but of size 250A 36KA
Earthing complete with galvanized steel earth plate electrode of size 600 x 600 x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of plate not less than 1.5 m below ground level connected to and including galvanized earth strip of size 25x4 mm (up or 7.5 mtr length) and GI pipe 40 mm light grade for protection of GI earth strip by means of bolts, nuts, check nuts and washers made out of galvanized iron and connected to earth test point as shown in electrical plate No. 3 of SSR Part-1-2009 and as specified or indicated and testing on completion including excavation and earth work any in type of strata available at site, PCC (1:3:6) type C-1 for earth chamber, precast RCC slab 50mm thick in cement concrete (1:2:4) type B-1 reinforced with welded steel wire fabric (xpm) weight not less the (4kg/sqm) funnel with GI watering pipe of 20mm bore medium grade, wire nuts and lugs complete all as specified and directed.
Material and labour for Painting of steel tubular pole 9.0 metre long, by applying two coat of aluminium paint after scraping / brushing and cleaning the rust on pole and cross arms. Aluminium painting will be done on pole above 1.5 metre height from ground level and balance 1.5 mtr from ground level will be painted by alternate layer of black and white enameled paint (30 Cms each). Pole Nos will be written on pole by black paint in yellow circle of 150mm dia, complete, all as specified and directed. Note:- Only one coat will be applied at one time and payment at 50% of coated rate to be applied at the first time of first coat. Second coat is to be done more than 30 days after first coat.
Cutting/trimming of tree branches of any size resting/interrupting the LT over head line any number of conductors span length between 45 to 50M cutting clearing 3 M away all around the conductor repeatedly as many as times required depending on the growth of new branches and removing the tree branches from site all as directed.
Supply and fixing in replacement of Bus bar chamber ratings of 63A 415V AC 50Hz with copper bus bar 3 Phase and neutral with hinged door at front side complete all as specified and directed
All as per item No 60 above but ratings of 100A 415V AC 50Hz
All as per item No 60 above but ratings of 200A 415V AC 50Hz
Supply and fixing in repairs Change over switch 4 pole 400A without enclosure.
Supply and fixing in repairs Change over switch 4 pole 125A without enclosure.
Supply and fixing in repairs Change over switch 4 pole 63A without enclosure.
Supply and fixing in repairs Change over switch 4 pole 63A in sheet metal enclosure.
Supply and fixing in repairs Change over switch 4 pole 100A in sheet metal enclosure.
Material and labour for straight through jointing kit suitable for LT UG cable of size 3½ core up to 25-50 sqmm complete all as specified and directed.
All as per item No 68 above but 70 sqmm up to 150 sqmm.
All as per item No 68 above but 185 sqmm up to 300 sqmm.
Material and labour for Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate in foundation all as specified and as directed.
Material and labour for PCC 1:3:6 type C1 using 20 mm graded stone aggregate for stay and coping for poles including necessary form work to exposed surfaces finished smooth and even all as specified and as directed.
Supply and fixing in replacement, sheet metal enclosure distribution box double door type suitable for MCCB 4 way TPN 415 volts vertical type 4 pole fixed flush type to wall, including 200 Amps bus bar, neutral bar standard DIN rail ,earth bar and cable tier for cable arrangement top and bottom removable gland plate and suitable for in and including of FP MCCB 100 Amps,16KA as incomer including taking down old enclosure complete all as specified and as directed. Note: Rate of above item is inclusive of MCCB 100 Amps
Supply and fixing in replacement, sheet metal enclosure distribution box double door type suitable for MCCB 8 way TPN 415 volts vertical type 4 pole fixed flush type to wall, including 200 Amps bus bar, neutral bar standard DIN rail ,earth bar and cable tier for cable arrangement top and bottom removable gland plate and suitable for in and including of FP MCCB 125 Amps,16KA as incomer including taking down old enclosure complete all as specified and as directed. Note: Rate of above item is inclusive of MCCB 125Amps
Material and labour for cutting out the burnt out cable and reconnecting by providing new lugs ,tapes etc for cable up to 50 Sqmm 3.5 core
All as per item No.75 above but cable of size 70 Sqmm to 120 Sqmm
Supply and replace in repair - MCCB 3 pole 25-32A 16KA - in LT panel boards / feeder pillar boxes including disconnecting and removing existing defective item from electric circuit including necessary connected fastners, burnt cables, accessories etc,. all as per site requirement/existing make/model all as specified and as directed by Engr-in-charge.
All as per item No 77 above but of size 40-50A 16KA
All as per item No 77 above but of size 63-80A 16KA
All as per item No 77 above but of size 80-100A 16KA
All as per item No 77 above but of size 100-125A 25KA
All as per item No 77 above but of size 160-200A 25KA
All as per item No 77 above but of size 250A 36KA
Supply & Erecting in replacement of Mild steel tubular swaged poles of 9.0 meter long 410, SP-55 complete with cast iron base plate, bracket, final taper plug, bolt, nuts & screws and painted on both side (internally & externally), external surface painted with two coat of aluminum paint over coat of red oxide primer and painting with black up to 1.5 meter from top of PCC coping white colour paint as in strips of equal width including marking pole numbers with one coat of synthetic enamel paint complete all as specified and as directed.
Supply and fixing in repairs LED Light fittings in repairs 60Watts including GI pipe bracket made out of 40mm dia light grade GI tubing bent to shape drilled with holes including MS clamps made out of 25x5mm thick MS flat including necessary bolts, nuts, washers, anchor fastners etc suitable for fixing security light complete all as specified and as directed. Make : CG, Cat No: LSTP-60-CDL or Equivalent in Havells/Bajaj/Wipro
Supply and fixing in repairs LED flood light 150W light fixture with pressure die cast housing with IP 65 protection all as specified and as directed. Make : CG, Cat No: LSFN-150-CDL/60 or Equivalent in Havells/Bajaj/Wipro
Shiva Shakthi Electrical Enterprises
M/S SRI BALAJI ENTERPRISES
eurekaenterprises
M/S Bhagyawanticonstruction
SREE VARU ELECTRICALS
C R R CONSTRUCTIONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .