Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC 25 A RR SAMY LANE KATTOOR COIMBATORE 641009 | COIMBATORE | COIMBATORE | TAMIL NADU | 641009 | L1 | Accepted-AOC BEING LOWEST TENDER, L1 | |
| 2 | L2₹38.6 L+₹2.1 L (5.72%)Rejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹39.8 L+₹3.3 L (9.18%)Rejected-Finance NO 1C C L C WORKS ROAD NEW COLONY CHROMEPET CHENNAI 600044 | CHENGALPATTU | TAMIL NADU | 600044 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹41.4 L+₹4.9 L (13.5%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹41.5 L+₹5.0 L (13.7%)Rejected-Finance C 150 ADG P CHENNAI | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
| Sl No | Description | Qty | Unit | KUMAR AGENCIES L4 | devan enterprises L2 | LAKSHMI ELECTRICAL ENTERPRISES L3 | rvelectricals L1 | S.RAMACHANDRAN L5 | K.AYYAPPAN L6 | BHARATH TECH L7 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCHEDULE A BOQ | ||||||||||
| 2.00 | Design, Supply and installation in replacement of Solar Module panel capacity not less than 545 Wp or above MNRE approved, mono crystalline Type, 60 Cell (minimum) /72 Cell duly connected using solar DC cables 1.1 KV, 4 Sqmm alongwith miscellaneous components like termination kits, lugs, sign boards, conduits etc.(cost of these items shall be deemed to be included in the cost the modules) comprising of following technical specification and as specified in PS complete all as specified and as directed.
(l) Certification - The PV modules must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type approval as per IEC61215/BIS14286 | 17 | Each | 38,550 ₹6,55,350 | 37,400 ₹6,35,800 | 39,225 ₹6,66,825 | 35,450 ₹6,02,650 Lowest | 38,000 ₹6,46,000 | 42,000 ₹7,14,000 | 36,520 ₹6,20,840 |
| 3.00 | Periodical maint of 1 MW solar power plant by providing one well knowledge technician from OEM with one helper for maintaining solar power plant every day basis analyising defets and attending complaints , checking all modules working conditions and circuits, cableing, wiring and other following equipments including servicing than rectification of minor deffects etc all as specifed and directed by Engr-in-Charge for the followings:-
(a) Solar Grid Connected inverter.
(b) Power condition units (PCU).
(c) Central inverter with maximum power point tracker/tracking (MPPT) feature certified by MNRE of capacity 1000 KW, 3 phase, 400 Volt, AC operated, 50 Hz duly reference taken from OEM drawings .
(d) VCBs upto 1200 Amps.
(e) ACBs and LT panels.
(f) DC/AC converter.
(g) AC combination box, AC distribution board.
(h) Moduler cleaning Spinkler sytem with pump/motors.
(j) Electrical cables & module mounting structure.
(k) SCADA sytem.
Note: 1. minor spares like lugs,terminals, SMPS, Air Filter and internal wiring incl in quoted rates.
2. Major Spares shall be measured and paid separately.
3. Contractor shall provide One technician from OEM and one helper every day in case failure provide technician and helper than necessery penalty charges Rs 2000 per person/Per day will be recovery in Bills. | 11 | Per Month | 88,350 ₹9,71,850 | 86,700 ₹9,53,700 | 87,550 ₹9,63,050 | 84,300 ₹9,27,300 Lowest | 88,000 ₹9,68,000 | 96,500 ₹10,61,500 | 96,300 ₹10,59,300 |
| 4.00 | S&F in replacement of MC4 connectors for one modules shall be as per SPV modules string combinations all as specified and directed by Engr-in-Charge. | 250 | Each | 260 ₹65,000 | 208 ₹52,000 | 220 ₹55,000 | 200 ₹50,000 Lowest | 260 ₹65,000 | 235 ₹58,750 | 340 ₹85,000 |
| 5.00 | S&F in replacement of cable copper shall conform to IEC-60227 and shall be of 650 V / 1.1 kV grade. The cable size 1x4 sqmm DC 1500 volt single strand copper conductor for Module Interconnections, array to junction boxes, junction boxes to DCDB, DCDB to PCU etc will be suitable to keep the voltage drop and losses to the minimum including cable tie for securing cable etc all as specifed and directed by Engr-in-Charge. | 1,420 | RM | 230 ₹3,26,600 | 188 ₹2,66,960 | 185 ₹2,62,700 | 181 ₹2,57,020 Lowest | 230 ₹3,26,600 | 225 ₹3,19,500 | 345 ₹4,89,900 |
| 6.00 | S&F in replacement of UPS of suitable capacity with all connected accessories charging unit for The SCADA system to meet the existing system run complete all as specifeid and directed by Engr-in-Charge.. | 1 | Each | 1,30,000 ₹1,30,000 | 1,45,000 ₹1,45,000 | 1,28,000 ₹1,28,000 | 1,10,000 ₹1,10,000 Lowest | 1,55,000 ₹1,55,000 | 1,82,500 ₹1,82,500 | 1,26,530 ₹1,26,530 |
| 7.00 | S&F in replacement of Dry type Batteries12V 26 AH for suitable capacity for above mentioned UPS for The SCADA system to meet the existing system run complete all as specifeid and directed by Engr-in-Charge. | 35 | Each | 4,100 ₹1,43,500 | 3,800 ₹1,33,000 | 3,900 ₹1,36,500 | 3,250 ₹1,13,750 Lowest | 4,500 ₹1,57,500 | 4,000 ₹1,40,000 | 4,350 ₹1,52,250 |
| 8.00 | M&L in replacement of DC Fuse & Fuse Holder for String Monitoring unit complete all as specifeid and directed by Engr-in-Charge. | 25 | Each | 5,500 ₹1,37,500 | 4,800 ₹1,20,000 | 5,200 ₹1,30,000 | 4,530 ₹1,13,250 Lowest | 5,600 ₹1,40,000 | 4,750 ₹1,18,750 | 7,895 ₹1,97,375 |
| 9.00 | Taking down existing unserviceable breather assembly of Transformer and supply and fix new breather assembly including sufficient silica gel etc. complete all as specified and as directed by the Engineer-in-Charge | 1 | Job | 12,500 ₹12,500 | 11,000 ₹11,000 | 12,300 ₹12,300 | 10,500 ₹10,500 | 10,500 ₹10,500 | 10,000 ₹10,000 Lowest | 13,250 ₹13,250 |
| 10.00 | M&L for renewal/servicing/upgradation/configuration of license and for software of SCADA system which should be capable of communicating with Inverter, Energy meters, protection control and relay panels, transformers alarm and trip signals, circuit breaker status, weather station with server which should be a PCU with latest chip set technology all as specifed and directed by Engr-in-Charge. | 1 | Job | 68,000 ₹68,000 | 64,250 ₹64,250 | 64,000 ₹64,000 | 63,500 ₹63,500 Lowest | 65,800 ₹65,800 | 75,000 ₹75,000 | 78,520 ₹78,520 |
Tender Value
Refer Docs
EMD Value
₹78,000
Closing Date
13 Sept 2025, 6:00 pmClosed
GE AF SULUR
KANGAYAMPALAYAM
PERIODICAL SERVICING REPAIR ROUTINE MAINT OF 1 MW SOLAR PLANT CONNECTED EM ITEMS AND OTHER MISC WKS AT AFS SULUR
2025_MES_726316_1
8793/E8
Open Tender
Miscellaneous Works
Item Rate
334 days
GE AF SULUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF SULUR
₹78,000
Yes
24 Oct 2025
16 Aug 2025
15 Sept 2025
16 Aug 2025
13 Sept 2025
29 Aug 2025
18 Aug 2025 - 27 Aug 2025
stage.html
html • 0.06 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .