Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC 35 DHARSA MAHITAL KHAN S BYE LANE JIGACHA MUKHERJEE PARA HOWRAH PIN 711112 | HOWRAH | HOWRAH | WEST BENGAL | 711112 | L1 | Accepted-AOC The work has been done. | |
| 2 | L2₹16.9 L+₹36,949 (2.24%)Rejected-Finance AT SCHOOL BAZAR PO MIDNAPORE PASCHIM MEDINIPUR 721101 | MIDNAPORE | PASCHIM MEDINIPUR | WEST BENGAL | 721101 | L2 | Rejected-Finance This bidder is not L1 | |
| 3 | L3₹18.8 L+₹2.3 L (14.1%)Rejected-Finance 184 BHUPENDRA ROY ROAD KOLKATA 700034 | KOLKATA | KOLKATA | WEST BENGAL | 700034 | L3 | Rejected-Finance This bidder is not L1 |
Tender Value
Refer Docs
EMD Value
₹45,000
Closing Date
29 Jan 2024, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE
OFFICE OF THE EXECUTIVE ENGINEER JHARGRAM ELECTRICAL DIVISION, P.W.Dte. Panch Matha More, PWD Building, Opposite Rabindra Park, Dist. Jhargram, Pin- 721507
Special Repairing and Renovation of Electrical Installation at Residential Government High School, Belpahari in the District of Jhargram and E.I. work at New Building B
2023_WBPWD_634337_1
WBPWD/EE/JED/eNIQ53/2023-24
Open Tender
ELECTRICAL WORKS ORG
Item Rate
21 days
Jhargram
Please refer Tender documents.
3 documents required · 3 mandatory
₹45,000
23 Apr 2025
15 Jan 2024
31 Jan 2024
15 Jan 2024
29 Jan 2024
15 Jan 2024
Amount
Dismentaling of existing entire old/damaged wiring and stored in the custody of concerned authority.
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N”copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed]
Average run 6 mtr
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Brand approved by EIC) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works
(On board)
Supplying and fixing 415V, TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
315 Amp (LT/ Havells/Standard make)
Supplying and fixing sheet steel (16SWG) cable end box on TPN SFU enclosure as per GS
S & F 415 V 16 to 32 A per way 4 way VTPN MCB DB upto 160 A for lexic MCB having IP 43-IK09 with metal door four pole MCCB as incomer& TP MCBas outgoingin suitable enclosurewith metal door flushed in wall as per GS comprising of the following: a. 415 v 125 Amp 25 ka c curve FP MCCB -1 no b. 415 v 63 A TPMCB ----- 3 no c.415 v 32 A TPMCB ----- 1 no d. cable end box -2 no(make: Legrand/ABB/L&T/siemens)
Supply & fixing 415 v 16 to 32 A per way , TPN MCBDB with ss enclosure double door with IP 42/43 protection with 40A 4 pole isolator as incomer and SPMCB (c curve 10 ka) as outgoing concealed in wall after cutting the wall & mending good the damages to original finish incl. interconnection with suitable size of cupper wire & neutral link & provision of earthing attachment . 4 way,40A FP MCB isolator & 12 no 6-32A SPMCB (C-Curve 10 KA) (MAKE Legrand/Crabtree/l&t/siemens/Standard)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+14 way Enclosure [Make: L&T (LTSD14N)/ Legrand/ Seimens]
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection ( As per make of DB )
6-10 A SP [Make: L&T/ Legrand/ Seimens]
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.40 A DP [Make: L&T/ Legrand/ Seimens]
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board with top cover plate incl. making necy. connections etc
Supply & Fixing 240 V, 6 A, 3 pin Modular type plug socket (Brand approved by EIC) with 6A Modular type switch, without plug top on 4 Module GI Modular type switch board with 3 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc
Supply & fixing 250 v 2no 3 pin 6 A flush type plug socket with 2no 6 A modular switch (Anchor make)switch on 6 module GI box with 6 module top cover & earthing attachment.
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC) with 16A Modular type switch, without plug top on 4 Module GI Modular type switch board with top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC
4x25 sqmm) + 2x16 sqmm) in 25 mm Rigid conduit 2 nos as ECC
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes
Cutting Channel of required size on masonry wall by Electric operated cutting machine incl. supplying & fixing of heavy gauge Polythene pipe of following diameter as per GS.
19 mm dia 3 mm thick
25mm dia 3 mm thick
Supply of 4/3.5 Core XLPE Insulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Gloster/KEI/Polycab]
3.5 Core 50 Sq. mm
3.5 Core 300 Sq. mm
2 Core 10 Sq. mm
Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting
Laying of cable upto 2 core 25 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages and painting
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
3.5Cx 50 Sqmm
3.5Cx 300 Sqmm
2Cx 10 Sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :
3.5Cx 50 Sqmm
3.5Cx 300 Sqmm
2Cx 10 Sqmm
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level.(make: ISI- medium)
Excavation of soil for installation of Earth Electrode and filling & ramming.(for morrum)
Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required
Connecting the equipment to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipment with bolts, nuts, washers, cable lugs etc. as required and mending good damages
No. 4 SWG
Extra for providing masonry enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe
Supply & delivery of Different Fittings as mentioned under:-
a. 20W LED tube [Make – Phillips cat.no. : BN021C LED22S PSU CW GR)
b. 40W LED tube [Make – Phillips cat no.-BN021 LED 40S-6500 PSU GR (4ft) )
Supply and fixing of 18 Watt LED recessed mounted light fittings(Make Philips/Bajaj/Crompton LSDEP-18-CDL)
Supply & Delivery of 1200 mm AC ceiling Fan(Usha striker plus/ orient quasar)
Supply of full metal body wall fan ( 450 mm) .[ Make-Usha TURBO 180 (METAL BLADE / EPC/Orient/Cinni Full metal body]
Supply of Exhaust Fan:
a. 250V 9''dia (make EPC / orient make heavy duty)
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter
a. 250V 9''dia
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6mm dia x 62 mm long)Al
a. 250V 9''dia
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with suitable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling with HW block and suitable size MS fastener, Ceiling plate, nipples etc. as required
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire
Supply and fixing of 9 Watt LED Bulb(Make Philips/Bajaj/Crompton)
Rooftop Light Supply & Delivery 3" dia. 2 Mtr. Long heavy gauge G.I. Pipe (minipole) having M.S. sole plate welded with drilled hole at bottom of the pole to be installed on roof of building incl. providing CC (6:3:1) base block (around the pole) dimension 0.60x0.60x0.76 mt. above ground level, neatly cemented finish (3 mm thick), at the base pole (in lieu of CC muffing) suitable for alkathene/ polythene pipe entry as directed for street light wiring, incl. Supply & fixing 50mm Dia 2mtr long detachable type GI Single arm bracket suitable for the pole head.The arm brfacket shall be properly welded with 15mm thick stifner plate of pole sleeve for strengthening including properly fixing arfangement with the pole by bolt , nut, wahser as per direction of EIC( ROOF TOP LIGHT)
S& delivery of Rooftop light make-CG, cat no-LSTP-100-CDL-M/Equivalent Philips/Havells ( ROOF TOP LIGHT)
Supplying and Fixing GI water proof looping cable box having hinged GI Top Cover having 4 mm thick with rubber gasket lining, railway type mechanical locking arrangement, earthing terminal with lug etc. of the following sizes as indicated below,Comprising of one 250 V, 15 A Kit-Kat fuse unit, one NL on porcelain insulator etc. and housing the same in pole muffing incl. addition and alteration to the existing CC muffing (6:3:1)after dismantling the damaged looping cable box etc. where necy. incl. painting(200 x 150 x 100mm)
S& drawing from loop box to fitting by 3x1.5 sq. mm PVC insulated copper wire (Finolex 'FR') through PVC/3mm thick Polythene pipe.
S &F of MU-2P Single Phase starter for control the rooftop Light (Make L&T) Cat No. CS90319KOPO, Relay Range (A) : 4 - 6.5
SITC of floor mounted (On a base frame ) totally enclosed, cubical type electrical control panel specification of which will be as below and as per drawing approved by EIC [ Dimension(W x H x D) (1900X1700X500) mm] The general construction of the pannel will conform to IS 8623:93 as ammended uptodate. The Degree of IP protection for the enclosure will be IP-42.
The enclosure will be fabricated out of 16SWG thick CRCA sheet, angle iron of size - 40X40X6 mm and channels of size -75X40X6mm
It will be compartmentalised type having seperate space and arrangement for busbars & cable alley,
The incoming and outgoing switches will be connected with the busbar with suitable size copper cable.
2 Nos 20 X 3 ( 20X 5 mm for >400A) copper strip shall be fixed all around the panel and will be connected to 2 nos copper earth bus bar connected to incoming earth conductor
It will be powder coated after seven tank pretreatment process and the paint thickness will be 60 micron.All tests should be made for the complete panel.The following switches & accessories will be fixed in the panel
INCOMING SWITCHES
S&F 415V,315/320 A open execution TPN SFU (L&T) incl 3 nos. 315/320A DIN type HRC fuse - 1 No
S&F of 415V, 315A open execution TPN Change Over ( L&T) - 1 No
BUSBAR
The Busbar will be made by electrolytic copper bars of size -520A 40X5 mm Cu bar 4 nos of length 3.0 mtr.
OUTGOING SWITCHES
S&F of 415V, TPN SFU ( Open Execution Type ) including HRC Fuses / 4Pole ACB / of following Capacities [ Make Simens }
415V,160 A open execution TPN SFU (L&T) incl 3 nos. 160A DIN type HRC fuse- 1 no
415V, 125A open execution TPN SFU (L&T) incl 3 nos. 125A DIN type HRC fuse-2 nos
415V, 100A open execution TPN SFU (L&T) incl 3 nos. 100A DIN type HRC fuse-1 no
415V, 63A open execution TPN SFU (L&T) incl 3 nos. 63A DIN type HRC fuse-8 nos
415V, 32A open execution TPN SFU( L&T) incl 3 nos. 32A DIN type HRC fuse-2 nos
Indicating lamp (R,Y,B) ( L&T)-3 nos
2Amp SP MCB -3 nos
Danger Notice Board [8" x 12"]- 1 no
Supply & delivery of Split type Room Air Conditioner fitted with rotary compressorhaving following major specification , 2 STAR Refrigerent R-32/R410 A, Rated cooling capacity min( Watt) 5500-7620 (as per capacity) , Minimum room discharge air flow(1280-2250) CFM , Rated power input maximum (1.3 TO2.3 KW as per capacity),BTHU/HR 17600 -24000,W/W= 3.33-2.83,ISEER star rating 2star, minimum tonnage required 1.9/2.0TR with other modern features. (With connection kit)
SPLIT AC - 2.0TR HITACHI TAKESHI 2100f - R32 - RMZ224HFDO/Mitsubishi Heavy/Mitsubishi Electric)
Installation, testing & commissioning of 2 ton capacity of split type AC machine both indoor & outdoor unit with necessary fixing on wall (indoor unit & outdoor unit ) as per direction of EIC by providing of 40x40x5 mm MS angle iron frame with necessary anchoring facilty on one side for necessary support on outer wall / making pedestal by angle & flat with necessaery welding each other etc. & Making hole for providing holding with outdoor unit by proper gauge GI nut bolt & washer with necessary painting by synthetic enamel paint two coat of one after another over one coat of RO primer or Providing of ISI marked bracket provide on wall by necessary providing of 100 mm MS / Gi Fastner arrangwement not less than 6 (six) no for each unit . with making hole on wall with making necessary slopping maintain & mending good damages as per direction of EIC.
Supply & delivery & installation of i. Electric cable 4 core 2.5 sqmm ( PWD approved make as per direction of EIC) ii. Cupper pipe for GAS( 6.35 MM) or 5/8 inch ; & (15.88 mm) or 1/4 inch for liquid as required iii.Nytryle insulation foam 1/ 2 inch ID & 3/ 8 inch thick class -1 iv. Nytryle insulation foam 3/4 inch ID & 3/ 8 inch thick class 1 aluminium foil and aerotape as reqd length of running of line iv. Drain pipe for pvc drainage connection upto ground floor level .
chargres for WBSEDCL load Augmentation over existing meter.
SREE KRISHNA ELECTRICAL
MODERN ELECTRIC
technical_1360089.pdf
PDF • 0.48 MB
techsummary_1360089.pdf
PDF • 0.31 MB
finance_1360089.pdf
PDF • 0.21 MB
BOQ Comparative Chart
xlsx • 0.02 MB
finsummary_1360089.pdf
PDF • 0.31 MB
AOC.pdf
PDF • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .