Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹18.0 L+₹1.4 L (8.44%)Rejected-AOC DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L2 | Rejected-AOC Not lowest | |
| 3 | L3₹19.0 L+₹2.4 L (14.2%)Rejected-AOC | L3 | Rejected-AOC Not lowest | |
| 4 | L4₹20.9 L+₹4.3 L (25.7%)Rejected-AOC | L4 | Rejected-AOC Not lowest | |
| 5 | L5₹21.0 L+₹4.4 L (26.4%)Rejected-AOC 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L5 | Rejected-AOC Not lowest |
Tender Value
₹22 L
EMD Value
₹44,000
Closing Date
19 Mar 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY , MUDFORT, SECUNDERABAD-500003
REPAIRS REPLACMENT OF LT UG CABLES, OVERHEAD LINES, CPACITOR BANKS, LT PANELS BOARDS, FEEDER PILLAR BOXES, MCCBS, SFUs, CHANGE OVER SWTICHES, CABLE JOINTS, JUMPERS, PAINTING OF POLES AND OTHER MISC EM ALLIED WORKS AT MILITARY HOSPITAL AND ADJOINING A
2020_MES_328789_1
GE(U)/SEC/TOKEN/46 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹44,000
Yes
9 May 2020
26 Feb 2020
21 Mar 2020
26 Feb 2020
19 Mar 2020
7 Mar 2020
Amount
M&L for cleaning LT/Street light poles of 8.5/9.0 mtrs long and any description thoroughly with necessary cleaning agent including scrapping up of old corroded paint dirt/dust/rust carefully and applying two coats of aluminum paint over a coat of red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engineer-in-Charge. Make:- ASIAN (APCOLITE)/ SHALIMAR (SUPER LAC)/ BERGER (LUXOL)
M&L for Dismantling foundation of LT pole of any height by taking out from PCC foundation complete and shifting to other location as directed including fixing the pole in true vertical position including excavation and earth work, PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as base concrete and PCC 1:3:6 type C2 (using 20mm graded stone aggregate) in both foundation and coping of poles all as specified in SSR Part I-2009 and applying two coats of aluminium paint to pole surface complete all as directed by Engineer-in-Charge.
Renewal of bracket suitable for street light fitting made out of 40mm dia GI tubing light grade 1.5m long bent to shape, fixed with necessary nuts bolts and clamps complete all as directed by Engr-in-Charge.
Taking down LED street light fitting/ LED flood light fitting of any watts and type from any height of pole/walls/any location and detecting the fault in the fitting by checking the accessories, wiring and refixing the same after repairs complete all as directed by Engineer-in-Charge. Note : Spares like driver and other accessories etc will be measured and paid separately under relevant items
S&F LED Driver suitable for upto 45 watts LED light fittings complete all as specified and directed. Make :Havells/Philips/Bajaj/Wipro/Luker.
S&F LED Driver suitable for from 60watts to 135 watts LED light fittings complete all as specified and directed. Make :Havells/Philips/Bajaj/Wipro/Luker. Note for item No.05&06:Drivers shall be techincally compitable for existing fittings & frame size shall be matched to existing fittings.
S&F PVC insulated,unarmoured 3 core 2.5Sqmm Aluminum cable including making neccessary cable terminations,lugs,glans complete all as directed by Engr - in-Charge
Cutting and trimming trees branches any girth and any size touching to overhead lines and cleaning the distance 1.5 mtr length both side of OH line with in a span of 35 mtrs each disposing the same, clearing the site all as directed by Engineer-in-Charge.
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set of 100 KVA to 625 KVA capacity listed parameters including testing complete all as specified and as directed.
S&F 12V, 150AH-180 AH maintenance free battery suitable for DG set complete all as specified and directed. Make:- AMARON/EXIDE/EXPRESS/CANON
S&F battery brass terminal and jelly complete all as specified and directed.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 32-63Amps, 16kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL. Note for item no.12.00 to 38.00: (i)The above item shall be executed immediately as and when required basis.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 32-63Amps, 25kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 100Amps, 25kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 125Amps, 25kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 160Amps, 35/36kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 200Amps, 25kA, 415volts,50 Hz, with adjustable settings, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 200Amps, 35/36kA, 415volts,50 Hz, with adjustable settings, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 250Amps, 25kA, 415volts,50 Hz, with adjustable settings, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 250Amps, 35/36kA, 415volts,50 Hz, with adjustable settings, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 315Amps to 400Amps, 35/36kA, 415volts,50 Hz, with adjustable settings & thermal,magnetic realse, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 400Amps, 50kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse,suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL..
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 630Amps, 35/36kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 3 pole, 630Amps, 50kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse,suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 32-63Amps, 25kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 100Amps, 25kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 100Amps, 35/36kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 125Amps, 25kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 160Amps, 25kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 160Amps, 35/36kA, 415volts,50 Hz, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 200Amps, 25kA, 415volts,50 Hz with adjustable settings,suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 200Amps, 35/36kA, 415volts,50 Hz with adjustable settings suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 250Amps, 25kA, 415volts,50 Hz with adjustable settings, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 250Amps, 35/36kA, 415volts,50 Hz with adjustable settings, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL..
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 315Amps to 400Amps, 35/36kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse,suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 400Amps, 50kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse,suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole, 630Amps, 50kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse,suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Disconnecting & taking out unserviceable MCCB and Supply,test,install & commissioning of new MCCB 4 pole,800Amps, 50kA, 415volts,50 Hz with adjustable settings & thermal,magnetic realse, suitable for exisitng panel(frame size shall be matched with existing one) of the following capacities for fixing in panel board/sheet metal enclosures/distribution boards with necessary cable connections,suitablel lugs, glands,nuts,bolts and screws complete all as specified and directed. Make:- Havells/L&T/Standard/HPL.
Supply&Fixing of 3 pole MCB,63amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing of capacitor duty contactors suitable for capacitor rating 25 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Schnieder/L&T/Seimens
Supply&Fixing elimator push button in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.
M& L for control wiring,relay programming and panel testing complete all as directed by Engr-in-Charge.
Supply&Fixing heavy duty box type capacitors 10kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing heavy duty box type capacitors 15kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing heavy duty box type capacitors 20kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing heavy duty box type capacitors 25kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing heavy duty box type capacitors 50kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing ultra heavy duty box type capacitors 20kVAR in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing of 3 pole MCB,32-40amps,C-curve,10kA,50Hz,440v in existing panel including necessary wiring & misc accessroies for satisfactory completion of job and taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing APFC relay 8 stages in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:HPL/L&T/Schnieder
Supply&Fixing of capacitor duty contactor suitable for capacitor rating 10 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Schnieder/L&T/Seimens
Supply&Fixing of capacitor duty contactor suitable for capacitor rating 15 kVAR ,50Hz,440v,3-ph,3-pole in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make: Schnieder/L&T/Seimens
Supply&Fixing of 6 No Auxiliray conactor ,50Hz,240v in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:L&T/Schnieder/Seimens
Supply&Fixing of 200/5 Amps Current transformers -03Nos(in three phases) including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge.
M&L on load change over switch 630 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T//HPL. Note for item no.56.00 to 61.00: (i)The above item shall be executed immediately as and when required basis.
M&L on load change over switch 400 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
M&L on load change over switch 320 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
M&L on load change over switch 200 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,font handle operated suitable in open execution type for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
M&L Off load change over switch 200 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,side handle operated with sheet metal enclosure suitable for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
M&L Off load change over switch 400 Amps capacity suitable for 3 phase, 4 pole, 415 Volts,side handle operated with sheet metal enclosure suitable for fixing in existing panels including necessary lugs,glands.,nuts,bolts inclduing taking down old unserviceable one complete all as specified and directed Make:- Havells/L&T/Standard/HPL
Servicing of DG Set AMF panel's of capacity 250kVA to 400kVA comprising of ACB/Breaker indoor/outdoor type of any make/model , checking of switching ON/OFF & tripping system, Spring charge Motor working system and Setting the same for proper working of Breaker, testing of operation manually and including rectifying the all minor repairs complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated
Servicing of DG Set AMF panel's of capacity up to 200kVA comprising of MCCB/Breakers, contacors indoor/outdoor type of any make/model , checking of switching ON/OFF & tripping system, Spring charge Motor working system and Setting the same for proper working of Breaker, testing of operation manually and including rectifying the all minor repairs complete all as directed by Engr-in-charge. Note:-All the mechanical parts are thoroughly cleaned by suitable cleaning agent & moving parts are properly lubricated
Renewal of 'V' belts for the following capacity DG sets as per existing size and model complete all as directed by Engr-in-charge. Make :- FENNER/ DUNLOP
182.5 KVA DG Set
400KVADG Set
100kVA DG set
82.5kVA DG set
40kVA DG Set
Maintenance of DG set and carrying out ‘B’ check and replacement of ‘B’ check kit filters such as Oil filter, by pass filter, fuel filter, ,CR element and CR plates complete with ‘O’ rings and draining of Engine oil and topping up with the new engine oil complete testing all as specified and directed by the Engr-in-Charge for the following capacity DG sets:- Note :- Engine oil shall be measured and paid separately.
Up to 100 KVA DG Set
Supply and filling the new engine oil 20W/40 for toping up upto the required level complete all as directed by Engr-in-charge Make :- CASTROL/ INDIAN OIL/ SERVO
S&F ACSR jumper in HT/LT over head line as that of existing size including binding wire, nuts, bolts & washers including taking down existing unserviceable/burnt out jumper complete all as directed by Engr-in-Charge. Note: The above item shall be executed immediately as and when required basis.
Renewal/ repairs of unserviceable automatic voltage regulator (AVR) upto 320 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM make. Note: The above item shall be executed immediately as and when required basis.
Renewal/ repairs of unserviceable automatic voltage regulator (AVR) 400 KVA to 625 KVA DG set including all spares, testing all as specified and directed by Engr-in-Charge. Make:- As per OEM make. Note: The above item shall be executed immediately as and when required basis.
Disconnecting all electrical connections from the unserviceable self starter of any make/ capacity model 24 volts, 180 /200 AH and taking down the self starter and transporting to civil workshop for carrying out repairs, complete overhauling the system including replacing the unserviceable parts bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply only Armature coil, field coil shall be measured and paid separately under relevant items of this Schedule.
Supply only Armature coil for self starter of any make, any capacity and any model 24 Volts, 120/150/180/200 AH complete all as directed by Engr-in-charge
Rewinding of field coil for self starter of any make, any capacity and any model 24 Volts, 120/150/180 /200AH complete all as directed by Engr-in-charge.
Disconnecting all electrical connections from the unserviceable self starter of any make/capacity/model 12 volts, 180 /200 AH and taking down the self starter and transporting to civil workshopfor carrying out repairs, complete overhauling the system including replacing the unserviceable parts bearing, carbon brushes, clutch plates etc refixing the self starter in its original position, testing and commissioning complete all as directed by Engr-in-charge. Note:- Supply of Armature coil, field coil shall be measured & paid separately under relevant items of this Schedule.
Supply only Armature coil for self starter of any make, any capacity and any model 12 Volts, 120/150/180/200 AH complete all as directed by Engr-in-charge
Rewinding of field coil for self starter of any make, any capacity and any model 12 Volts, 120/150/180/200 AH complete all as directed by Engr-in-charge.
Disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly of the existing make and model and various capacities of DG sets and taking down the radiator assembly by unscrewing all mechanical connections from the existing mounting, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of radiator assembly cleaning thoroughly the chocked pipe of the radiator by using detergent, lime caustic soda, cotton etc., cleaning of all the deposited sediments in the pipes/tubes including arresting of leakage by means of soldering, brazing and transporting back to site and refixing the same in its original position with suitable size nuts, bolts and washers etc., for the following DG sets all as specified and directed by Engr-in-Charge:
Upto 110 KVA DG Set
125 KVA to 182.5 KVA DG Set
320 KVA to 400 KVA DG Set
S&F Automatic cut off Battery Charger suitable for 12 V, up to 10 Amp Battery complete all as directed by Engr-in-charge. Make SMPS/ Phonix
S&F Automatic cut off Battery Charger suitable for 24 V, up to 10 Amp Battery complete all as directed by Engr-in-charge. Make SMPS/ Phonix
Disconnecting and taking out unserviceable existing water temperature gauge and supply,test,install & commissioning of new water temperature gauge for the DG set of any description complete all as directed by Engr-in-charge.
Disconnecting and taking out unserviceable existing unserviceable lubricant oil temperature gauge and supply,test,install & commissioning of new lubricant oil temperature gauge for the DG set of any capacity complete all as directed by Engr-in-charge.
Disconnecting and taking out unserviceable existing oil pressure gauge and supply,test,install & commissioning of new oil pressure gauge for the DG SET of any capacity complete all as directed by Engr-in-charge.
Disconnecting and taking out unserviceable existing Solenoid switch and supply,test,install & commissioning of new solenoid switch for DG set of any make and any capacity complete all as directed by Engr-in-charge.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5m below ground level, connecting to the Galvanized iron earth strip 32 x 6mm dia, by means of nuts, bolts, check nuts and washer etc of galvanized iron and earth lead protected by provision of GI pipe medium grade 40mm bore from earth electrode to test point incl provn of concrete pit in PCC (1:2:4) type B-1 using 20mm graded stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM sheet (weight not less than 4Kg/Sqm) and frame of angle iron 25 x 25 x 6mm with lugs 2 Nos and with 8mm dia MS bar handle made to shape, GI pipe medium grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling test point with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning in and removal of surplus soil to a distance not exceeding 50mtr, complete all as specified in electrical plate No 3 of SSR Part I and connection to earth test point including testing on completion all as directed. Note :- Item of earthing includes cost of 7.5m long galvanized iron earth strip of 32 x 6mm size and protection pipe of 40mm bore GI medium grade.
Supply and connect LT 1100 V outdoor type cable straight through heat shrinkable epoxy joint kit suitable for the following sizes with necessary jointing materials complete all as directed by Engr-in-charge. Make :- M-SEAL/ DENSON/3-M/ RAYCHEM (a) 3.5 core x 25/35 sqmm.
3.5 core x 25/35 sqmm.
3.5 core x 70/95 sqmm.
3.5 core x 120/150 sqmm.
3.5 core x 185/240 sqmm.
3.5 core x 300/400Sqmm
Isolate,disconnect,dismantle the burnt out lugs from main switches/MCCB/ACB/Breakers and Supply &fix new lugs with crimping tool as per existing one including fixing, insulation, termination tomain switches/MCCB/ ACB/Breakers for the following sizes of cables complete all as directed by Engr -In-Charge. Note : cleaning the cable termination ends insulation as required length and fixing new lugs as per size including well crimping to the lugs for both ends of cable complete are included in quoted rates.
25 sqmm to 50 sqmm
70 sqmm to 95 sqmm
120 sqm to 240 sqmm
300 sqmm to 400 sqmm
up to 16 Sqmm
Meggering of HT Overhead conductor between Span to Span/Six pole structure/four pole structure, any type insulator with complete diconnection & reconnection of jumper for checking of fault and rectification for any size any place after disconnection of AB switch complete.
Supply,test,laying & commissioning of XLPE insulated, armoured (heavy duty) electric cable with aluminium stranded conductor, 1100 volts grade, laid in trenches / duct/ fixed to wall with suitable size clamps / passing through pipe/Tunnel/under ground/surface up to the termination point(as directed by Engr-in-Charge) with necessary end terminations with suitable size cable lugs, cable glands, fixing of lugs with crimping with tool,nuts,boltsetc of the following sizes and including taking out unserviceable burnt out cable from its existing location complete all as specified and directed by Engr-in-Charge :-
3.5 Core X 95 Sqmm
3.5 Core X 120 Sqmm
3.5 Core X 185 Sqmm
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth for foundation, laying of poles in trenches and getting out in soft/ loose soil complete all as specified and as directed Engineer-in-Charge.
Returning, filling including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick complete all as directed by Engineer-in-Charge.
Removal of surplus soil to a distance no exceeding 50 mtrs and depositing where directed at a level not exceeding 1.5 mtrs above from the starting point complete all as directed by Engineer-in-charge.
Supply and spread approved dry river sand for foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as directed by Engr-in-Charge Note:- Punned thickness will be measured for payment purpose
M&L brick protection with common burnt brick sub class ‘B’ of size 230x115x75mm for cable protection complete all as directed by Engr-in-charge.
M & L Galvanised iron tubing 80 mm dia light grade laind in trenches/floors/walls for eath lead protection and cables at road crossing etc complete all as specified and directed.
M & L cutting of road, hard standing made of concrete or premix carpet, WBM, soiling and morrum filling including excavation for laying of cable pipe all as directed and making good the road/hard standing by using all old/new materials and with PCC (1:2:4) etc, required to match with the existing surface complete all as specified and directed.
Supply,test,install & commsissioning of Wall mounted Bus bar chambers(including 4 bus bars i.e R,Y,B and neutral),3-Ph with netral,1100volts,50Hz including suitable sheet metal enclosure along with necessary screws,nuts,bolts and other Misc accessroies and making connections(input &out put) with cable terminal ends complete for the following current carrying capacities Make: Havells/L&T/Standard
4-Way, 100 Amps
4-Way,200Amps
4-Way,315Amps
Supply&Fixing APFC relay 6 stage in existing panel including including necessary wiring & misc accessroies for satisfactory completion of job taking down old unserviceable one complete all as directed by Engineer-in-Charge. Make:HPL/L&T/Schnieder
Mavee Syndicate
vvcenterprises
POWER CONSTRUCTION COMPANY
STANDARD AGENCIES
Srinivasa Consructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .