Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹63.6 LAccepted-AOC 87 248 ACHARYA NAGAR KANPUR 03 UP | KANPUR | KANPUR | UTTAR PRADESH | 208003 | 1 | Accepted-AOC Being L-1 | |
| 2 | 2₹67.0 L+₹3.1 L (4.81%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 | |
| 3 | 3₹67.3 L+₹3.4 L (5.31%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | 3 | Rejected-Finance Being other than L-1 | |
| 4 | 4₹76.8 L+₹12.9 L (20.2%)Rejected-Finance | 4 | Rejected-Finance Being other than L-1 |
Tender Value
₹70 L
EMD Value
₹1.3 L
Closing Date
15 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sharath Ravindran CWE
HQ CWE (AF) Chakeri Kanpur
RENOVATION OF ISC BUILDING AND INSTALLATION OF GLASS PANELS IN THE ANNEXE BUILDING OF TTCLE HANGAR AT 1BRD AT AFS CHAKERI KANPUR
2022_MES_506977_1
CA No.CWE(AF)/CHK/BR/T-39 OF 2021-22
Open Tender
Civil Works
Item Rate
180 days
GE (AF) B/R Chakeri
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE (AF) B/R Chakeri
₹1.3 L
25 Apr 2022
9 Feb 2022
17 Mar 2022
9 Feb 2022
15 Mar 2022
2 Mar 2022
60 days
Amount
Demolition of brick work / stone masonry built in cement mortar complete all as specified and directed.
M&L brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4, complete all as specified and directed.
Taking down cement plaster of any description on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for rendering 15 mm thick on brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm thick on brick work or concrete surface in cement mortar 1:4 finished even and smooth without using extra cement complete all as specified and as directed.
Complete removal of existing treatment i.e. white wash, colour wash , distempering etc. of wall complete all as specified and directed.
Complete removal of existing treatment i.e. white wash, colour wash , distempering etc. of ceiling complete all as specified and directed.
M&L preparation of new/old surfaces of walls and applying two coat of oil bound distemper over a coat of primer and 1 mm thick JK birla wall care putty complete all as specified and directed
M&L preparation of new/old surfaces of ceiling and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed
Removing existing painted surface including cleaning the surface of wall/ ceiling with the help of hand held /long hand sander and preparing the surface smooth including necessary repair to cracks by filling of required thickness with filling compound paste complete all as specided and directed by Engineer-in-charge.
M&L preparation of wall surfaces and applying one coat of wall care putty JK birla 1mm thick and applying one coat of exterior water based primer with airless spray technology with maximum working pressure of 3300 Psi and capable of operating single spray gun with a maximum material hose length of 30 mtr complete all as directed by Engineer-in-charge.
M & L applying two coats of exterior weather proof anti algae 100% acrylic smooth emulsion with 8 year period long life using air less technology with maximum working pressure of 3300 Psi and capable of operational single spray gun with a maximum material hose length 30 mtr. The spray should be of reputed make as specified by paint supplier and as mentioned in PS with accessories for applying the exterior emulsion should be able to spray in hard to reach areas and achieve the good bounding and penetration of paint on the surface to achieve excellent application using limited manpower complete all as specified. (Note :- Make of exterior weather proof shall be approved by GE after producing 8 years performance gurantee/warantee of anti algae & detterioration of paint by contractor)
M & L for 16 mm thick of size 600mmx 600 mm mineral fibre false ceiling system of pattern classic lite RH 99 (bevelled tegular edge) of make Armstrong or equivalent make and model as approved by GE including grid system using hot dipped galvanised steel section, exposed surface with pre-powder coated capping, main runner and cross runner and to comprise main tee/runner 15 mm x 38 mm size (load carrying capacity 14 Kg/Sqm) spaced at 1200 mm long cross tee/runner to be interlocked between main runners at 600 mm centre to centre from 1200 x 600 mm module, cut sub cross tee/runner 600 mm require independent support. Wall angle of size 19 mm x 19 mm, secured to the periphery of the wall at 450 mm maximum centre The above grid is suspended at every 1200 mm centre to centre in both direction and starting from wall at the distance 350 mm from wall by using 3.50 mm dia line wire with suitable fasteners and hook clip complete all as specified & directed.
Dismantling floor, hearth or wall tiling ( Glazed tiles, cement concrete tiles, terrazzo tiles including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises
M&L vitrified ceramic tiles dark shade double charged/ultra charged 10mm thick (square/ rectangular) ,polished ,area of each tiles exceeding 0.42 sqm but not exc 1.00 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade over & including screed bed or bedding layer of cement mortar 15mm thick in CM 1:6 finished rough for laying floor finishes complete all as specified and as directed.
All as per item no 15 above but for dado/skirting over & including 10 mm thick rendering in CM 1:4 complete all as specified and as directed.
M&L joint free Non - skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) premium quality area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement including 15 mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
All as per item no 17 above but for dado/skirting over & including 10 mm thick rendering in CM 1:4 complete all as specified and as directed.
M&L glazed ceramic coloured tiles in vertical surface 450x300x7mm thick, set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles, over and including 15 mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in soft /loose soil complete all as specified and directed.
M&L 100 mm thick PCC 1:4:8 sub base (40mm graded crushed stone aggregate) type D- 2 complete all as specified and directed.
M&L sand filling under floors or in foundation free from vegetation & shurbs including watering, ramming and consolidation complete all as specified and directed.
M&L factory made machine pressed precast concrete coloured interlocking paver block 60 mm thick having lacquer finish any shape and size confirming to IS 15658-2006, M-35 with grey cement and pigment complete all as specified and directed. (Note:- Make & Brand Name shall be embosed in each paver block).
M&L factory made pre-cast cement concrete 1:2:4 type B-1 (using 20 mm graded aggregate) block masonry with solid blocks as in kerb stone and like exc. 10 cm in width and setting in mortar 1:4, complete all as specified and directed.
M&L two coat plaster 35 mm thick (20 mm + 15 mm) on rough concrete surfaces of fin, facia, chhajja and similar article in CM 1:3 finished even and smooth without using extra cement in any height including required necessary scaffolding complete all as specified & directed. (Note :- (i) Two coat plaster shall be carried out as mentioned in clause 14.18 of SSR-2009, Part-I. (ii) Each layer of plaster shall be carried out after proper curing period of not less than 7 days after approval by Engineer-in-Charge for executing 2nd layer of plaster.)
M&L repair to chhajja of area not exc 1.20 Sqm each patch including plaster in CM 1:3 or PCC type B0 1:2:4 (using 12.5 mm stone aggregate ) on top with water proofing compound including benching/hunching, repair to broken plaster with dubbing coat complete all as specified and as directed.
M&L repair to chhajja of area exc 1.20 Sqm but not exc 2.00 Sqm each patch including plaster in CM 1:3 or PCC type B0 1:2:4 (using 12.5 mm stone aggregate on top with water proofing compound including benching/hunching, repair to broken plaster with dubbing coat complete all as specified and directed.
Demolition of cement concrete (un-reinforced) not exc 15 cm thickness (below or above ground level ) including removal of rebbish out side MOD & cleaning the surface with contractor's own arrangment complete all as specified & directed by Engineer-in-Charge.
M & L 75 mm thick cement concrete type C- 2, 1:3:6 ( using 40 mm graded aggregate) as in plinth protection finishing surface even and smooth without using extra cement complete all as specified and as directed.
Taking down/removing existing water proofing treatment on roof surfaces of any thickness as per site complete including any type of mud phuska or lean concrete or screed bed including racking out joints, hacking for key, scrubbing down with water etc and removing rubbish out of MoD land at his own arrangements complete all as specified and as directed.
M&L PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) thickness as required at site for roof levelling padding concrete complete all as specified and directed.
M & L 15 mm thick rendering on concrete surfaces in CM (1:3) on roof surface mixed with liquid water proofing compound @ 200 ml per bag of cement of wt 50 kg complete all as specified and directed. (Note: Liquid Water proofing compound shall be measured and paid separately).
Supply only liquid water proofing compound of Make Pidilite or Dr Fixit as approved by GE complete all as specified and as directed.
M&L reinforced elastomeric liquid water proofing compound membrane with resilient acrylic polymers having sun reflectivity Index (SRI) of 105 as approved by GE on top of roof surface in three coats as per manufacturer's instructions but not less than 10.76 liters/ X Sqm and one coat of self priming of elastomeric water proofing liquid (dilution with water in the ratio of 3 :1 i.e. 3 part of water proofing liquid and one part of water) and two coats of undiluted elastomeric water proofing liquid. The dry film thickness of complete allocation/ system should not be less than 600 micron. The treatment shall be carried out through authorised representative of manufacturer and application shall be by mechanical sprayers or as directed by GE. (Note: Contractor shall be provide 10 (Ten) years gurantee of roof treatment after taking written gurantee from manufacturer).
Demolition of un-reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L PCC type B1 (1:2:4) using 20 mm graded stone aggregate in copings / benching’s, string courses and the like including weathering, slightly rounded or chamfered angles and throating, as directed..
Taking down eaves, gutters and rain water pipes any size and pattern including all fittings complete all as specified and as directed.
Supply and fix PVC (SWR) pipes 160mm bore single socketed in any length of pressure rating 4kg/Sqcm with or without rubber ring joints fixed to wall with MS clamps, complete all as specified and as directed.
S&F PVC SWR bend/shoe of any radius for 150 mm dia complete all as specified and directed.
S & F mild steel work in support for rain water pipe, hooks, heavy pintle hinges, large hasp hinges, stops, wall tie etc. and similar work confirming to Fe- 290 Grade E-165.
M&L 18-20 mm thick granite stone slab of any shade as approved by GE and work (table rubbed and polished) in steps jambs, pillars, window -cills cooking platforms and like in 15mm thick cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, cutting and moulding edges complete all as specified and directed.
Dismantling structural steel work including doors, gates, cattle trap but excluding framed truss etc complete all as specified and directed.
S&F collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.50 Cum, getting out in hard / dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance not exc 50m and making good surface complete all as specified and directed.
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate as in bed block for fixing of structural angle iron post or any other similar work complete all as specified and directed
S&F rolled mild steel joist, channel, angle or tee sections, fixed independently, as in posts of trusse without connecting plates etc (cut to ordinary lengths i.e within 20mm of the length indicated) conforming to grade E-250 (Fe-410W quality) of any size shape complete all as specified and directed.
S&F rolled mild steel section as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.
S&F coloured galvalume profile sheet in roofing shall be with feed material manufactured from 0.50 mm (minimum) base metal thickness (BMT), minimum 550 MPa yield strength and shall confirm to physical specifications of ASTM-792 or equivalent. colour coated galvalume sheet shall have maximum pitch of 250 mm C/C and minimum 28 mm crest depth in length as per site requirement. The steel sheet shall be coated with hot dip metallic Aluminium Zinc alloy (55% Aluminiumm, 43.5% Zinc, 1.5% silicon) coating AZ 150 as 150 gm/Sq. mt total on both sides. The contractor shall submit manufacturer test certificates for the chemical and mechanical properties, confirming genuinity of materials including base metal thickness paint thickness and AZ 150 coating thickness must be submitted for approval to GE prior to the installation / fixing. The manufacturer of sheet should submit related documents for expected product service performance of pre painted metal sheet as per relevant ASTM/ IS. Manufacturer‟s recommended installation methodology shall be adopted for installation of roofing including profiled sheet, capping, trims, flashings, gutter and all types of accessories considered for roofing. Fastener shall be used for fixing roofing system as per manufacturer‟s recommendation. The painting shall be coloured baked enamel super durable polyester with silicon coating of film thickness of minimum 25 micron (including primer) on top and minimum 10 micron (including primer) on interior face. The paint shall be of shade as approved by GE. The sheet shall have wide pans with minimum 2 small upward stiffening ribs for effective water shedding and special male/ female ends with full return legs on laps for purlin support and fixed with self-driling screws all as specified and directed. (Note : Total thickness of sheet with BMT , AZ 150 coating and panting shall be minimum 0.575 mm thick. If 0.575 mm thickness sheet is not available in market then next higher thickness of sheet shall be applicable without any price adjustment.)
M&L preparation of old painted steel and iron surfaces of any description over 10cm girth or width not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L preparation of new steel surfaces and applying two coats of synthetic enamel paint exceeding 10 cm width or girth over a coat of red oxide primer complete all as specified and directed.
Removing excavated material exc 1.50 km but not exc 5 km and deposited where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified and directed.
Disconnecting existing tanks of capacity exc 500 ltr but not exc 1000 ltr capacity setting aside (or lowering if required) for repairs, Cleaning, etc. and hoisting if required reconnecting and re-fixing in position, complete all as specified and directed
Taking down steel water tubing of 15 mm dia bore incl connection & removal to store complete all as specified and as directed.
Taking down steel water tubing of 20 mm dia bore incl connection & removal to store complete all as specified and as directed.
S&F steel water tubing 15mm dia (bore), galvanised, ‘medium grade’ with all fittings, fixed on walls, ceiling or laid in floors or any other situation with fittings and connections, etc., complete all as specified & directed.
S&F steel water tubing 20 mm dia (bore), galvanised, ‘medium grade’ with all fittings, fixed on walls, ceiling or laid in floors or any other situation with fittings and connections, etc., complete all as specified & directed.
Refixing of 15 mm bore old steel tubing and connections in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
Refixing of 20 mm bore old steel tubing and connections in new or old position (walls, ceiling, floors, etc) complete all as specified and as directed.
S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S&F in repair 10 ltr capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets and PVC flush pipe complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pan (pedestal pattern) including all necessary fittings complete all as specified and directed.
S&F in repair vitreous China wash basin, white or coloured , flat back, size 550x400 mm excluding taps, but including 32 mm dia waste coupling chromium plated brass and all fittings complete all as specified and as directed.
S&F in repair brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and as directed.
S&F in repair bib taps with wall flange , cast copper alloy, chromium plated fancy type, long body, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and as directed.
S&F in repair 15 mm bore pillar taps, chromium plated, fancy type, , screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and as directed.
S&F in repair stop cock/angle valve cast copper alloy , chromium plated fancy type screwed down high pressure , screwed both ends for iron pipe or for union of 15 mm bore complete all as specified and as directed.
S&F PVC connection 15 mm dia with PTMT nuts of length 450 mm complete all as specified and as directed.
S&F in repair vitreous China Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and union for discharge pipe complete all as specified and as directed. (Note :- Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe (minimum weight 60gm) complete all as specified and as directed.
S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors ladder framed balusters; walk ways, railings, frame work of water tanks and similar work conforming t o Fe.290. Gde-E-165 complete all as specified and as directed.
SPECIAL ITMES Taking down chowkhats with shutters (without taking off shutters from the frame), exc 1.50 sqm but not exc 4.00 sqm each complete all as specified and directed.
S&F aluminium door with chowkhat /frame made with aluminium section with size 100x44x2mm thick and shutter of vertical style with section 84x44x2mm thick and top /middle / bottom rails of shutter made with 112x44x2mm thick over and including 5mm thick tinted glass panes , including necessary fixing arrangment ,joining cleats, glazing clips,rubber beading ,floor door spring, tower bolts 200mm long, mortice lock 300 mm ,4 lever, rounded handles etc complete all as specified and as directed.
M & L aluminium two track sliding window with frame of section No 20829 & 20830 of Jindal or equivalent make. The window shutters shall be of section No 20736 & 20738 of Jindal or equivalent make including supply and fixing 5 mm thick toughened glass (tinted), glazing clips, rubber beading alongwith roller, locking arrangement etc complete all as specified and as directed.
S&F 6 mm thick aluminium grill of mesh size not exc 80 mm x 80 mm fixed with aluminium Y channel complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with suitable aluminium section to aluminium window complete all as specified and directed.
S&F anodised aluminium frame for aluminium partition of different standard sections with one or more rebates including jointing cleat for fixing etc of approved make JINDAL or equivalent complete all as specified and as directed.
S&F aluminium partition panel of thickness not less than 4mm, fixed with rubber beading and aluminium snap beading in aluminium partition work, complete all as specified and as directed.
S&F 5 mm thick plain sheet glass, ordinary quality and glazing with rubber beading and aluminium beads to aluminium frame work in squares exceeding 0.5 Sqm in each pane complete all as specified and as directed.
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets, ceiling rose, pendants, Holders, etc and making good all disturbed surface to wall, floor etc by means of cement mortar (1 : 3) or plaster of Peris and to match / finish new surface as the existing surface either by using same colour distemper, Putti or white / colour wash complete all as specified and as directed. (Note: Same board point wiring shall not be paid being including in board dismantling cost).
Taking down main switch/DB/AC box of any capacity including fixing accessories complete all as specified and directed.
Taking down old unserviceable LED light fitting of any capacity and rating complete all as specified and directed.
Fixing only serviceable LED light fitting after checking it of any size and any make by taking out from existing location (wall/roof etc) and fixing it to any other location including all fixing arrangement of wall/roof including electric connection complete all as specified and as directed.
Taking down old serviceable ceiling/wall/ exhaust fan of any capacity and rating and deposit in MES store yard complete all as specified and directed.
M & L for one light, fan, call bell concealed point wiring on wall and surface on ceiling/roof with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid ivory PVC conduit medium grade ISI marked not less than 19 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized MS sunken boxes made out of MS sheet of thickness not less than 1.6 mm with earth dolly and modular white cover plate with frame for fixing of switches / sockets, fan regulators, wall mounting fittings, door bell & bulkhead etc with MS screw and cup washers including PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing including cutting the chases and making good the surface by cement mortar (1:3) and for matching / finishing of new surfaces either by means of plaster of peris/ Putti or distemper / colour wash with same existing colour surfaces complete all as specified and directed. (Note : Rate of modular metal flush box and modular white cover plate required for modular switches and sockets of any rating are deemed to be included in the quoted rate).
All as per item No 85 here-in-above but for one socket point controlled by one switch on independent board.
All as per item No 85 here-in-above but for one socket point controlled by one switch on same board.
All as per item No 85 here-in-above but for power point wiring with 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable and 2.5 Sqmm PVC-FRLS insulated, unsheathed, copper conductor, stranded 1100 volt grade cable as continuous earth lead.
S&F socket outlet 5 pin, 5 Amps flush type white finish complete all as specified and as directed.
S&F switch flush type single pole one way 5 Amps, 240 volts, white finish complete all as specified and as directed.
S&F switch flush type single pole one way 15 Amps, 240 volts, white finish complete all as specified and as directed.
S&F socket outlet 5 pin, 5/15 Amps flush type white finish complete all as specified and as directed.
S&F modular switch 1way 6 Amp, 1 module complete all as specified and as directed.
S&F modular switch 1way 16 Amp, 1 module complete all as specified and as directed.
S&F modular socket 6 Amp, 2/3 pin combined 2 module complete all as specified and as directed.
S&F modular sockets 6/16 Amp, 2/3 pin combined 2 module complete all as specified and as directed.
S & F ceiling rose, surface backlight, 65 x 20 mm three terminal complete all as specified and as directed.
S&F sheet metal enclosure, 20 amp single pole & neutral with a two pin and earth plug and socket complete in metal clad board with one single pole MCB 20 amp fixed properly on the concealed position complete all as specified and as directed.
S & F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 4 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed.
S & F double door metallic sheet metal enclosure for DB when MCBs to be used SPN 8 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed.
S & F factory made double door epoxy powder coated distribution board TPN 8 ways (TPN, MCCB, Vertical DB) with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall/ on angle iron frame and suitable for universal mounting and including 200 amp copper busbar, neutral bar, standard DIN rail, earth bar and cable ties for cable management top and bottom removal gland plates with knockout and suitable for one 4 pole MCCB 100 Amps as incommer and SP/TPN MCBs as outgoing complete all as specified and directed.
S&F MCB SP 6 Amp to 32 amps, 240 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
S&F MCB SPN 20 to 32 amps, 240 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
S&F MCB SPN 40 to 63 amps, 240 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
S&F MCB TP 40 to 63 amps, 415 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
S&F MCB TPN 40 to 63 amps, 415 Volts, 10 KA capacity having C-curve characteristics connected with suitable lugs complete all as specified and directed.
S&F MCCB 4 pole, 415 Volt grade, AC 100 Amps, 25KA and Ics =100% of Icu with adjustable thermal release complete all as specified and directed.
S&F sub main wiring with two runs of single core 4 sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC rigid conduit 20 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 4 sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring complete all as specified and directed. (Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one RM).
S&F sub main wiring with two runs of single core 6 sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC rigid conduit 20 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 6 sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring complete all as specified and directed. (Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one RM).
S&F sub main wiring with four runs of single core 4 sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC rigid conduit 20 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 4 sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring complete all as specified and directed. (Note. Four run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one RM).
S&F sub main wiring with four runs of single core 6 sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC rigid conduit 20 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 6 sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring complete all as specified and directed. (Note. Four run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one RM).
M&L servicing, painting and re-fixing of ceiling fans retrieve from above complete all as specified and directed.
S&F security light fitting 110W LED with pressure die cast housing suitable for IP66 protection to be mounted near roof of hangar on outside wall including electrical connections complete all as specified and as directed. (Make: Wipro cat Part No LR02-122-XXX-57-G2 or Philips Cat Part No BRP409 LED 115CW SLA FG PSU GR V2 or equivalent make in Havells/ Bajaj/ Crompton/ GE).
S&F in replacement of slim profile surface mounted down light 2000 lumen in round shape, 6500K including all fixing arrangement complete all as specified and directed. (Make :Philips cat Part No SM251C LED20S-6500 PSU WH or equivalent in wipro/Havells/ Bajaj/ Crompton/ GE).
S&F in replacement for energy saver LED light fitting 40 watt, 230 Volts, single tube mounting including LED Tube/ LED blocks 40 Watt ,Lumen OUTPUT NOT LESS THEN 100 LM /WATT with 50000 burning Hours, PF = 0.95 complete with electronic driver LED Printed board, end cover, connector box etc and accessories, prewired, LED including required fixing arrangements and electric connection with three core copper cable from ceiling rose to led light fitting complete all as specified and directed. (Make: PHILIPS BN100C LED 40S-6500 PSU L120GR or equivalent in Wipro cat Part No LL24R-541-XXX-57-XX or equivalentas approved by GE)
S&F in replacement complete for recess mounting LED Panel 600x600 mm fittings made of CRCA powder coated finish LED used shall be SMD type and fixture should have minimum efficiency at system level (Not chip level) 100lm/watt, life of fixture 50000 burning hours @ L70% Lumen maintenance ,CRI MORE THEN 80,pf 0.95 and an operating voltage 140 Volt to 270 volt system wattage 31 - 36 watt complete electronic drivers with all internal electric connections complete all as specified and directed. (Make :Philips Cat No. RC 380 B LED 36S -6500 G5 L60 W60 PSU OD or equivalent in Wipro Cat Part No CRCO10SO38HP 57GL1 or equivalent make in Havells/ Bajaj/ Crompton/ GE).
S&F in replacement complete for recess mounting 1' x 4' LED Luminaire with high transmitive diffuser suitable for indoor spaces fittings made of CRCA powder coated finish LED and fixture should have minimum efficiency at system level (Not chip level) 100lm/watt, life of fixture 50000 burning hours @ L70% Lumen maintenance ,CRI MORE THEN 80,pf 0.95 and an operating voltage 140 Volt to 270 volt system wattage 31 - 36 watt complete electronic drivers with all internal electric connections complete all as specified and directed. (Make :Philips Cat No. RC 380 B LED 36S -6500 G5 L3 W12 PSU OD or equivalent in Wipro Cat Part No CRCO13SO36HP57GL1 or equivalent in Havells/ Bajaj/ Crompton/ GE).
S&F earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4.00mm dia galvanised iron or steel wire complete all as specified and directed.
S&F GI tube light grade with all fitting laid in trenches of size 15mm bore for protection of GI wire 4mm complete all as specified and directed.
S&F twin type aviation light over roof of hangar of approved make including all necessary fixing arrangement along with electric connection by securing it with necessary clamps etc complete all as specified and directed.
Taking down sub main wiring copper/aluminium of any size from any location and in any position inside building/Hangar in conduit whether surface or concealed along with fixing and other accessories complete all as specified and directed.
M&L earthing complete with galvanised steet earth electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of earth electrode not less than 1.5 mtr below normal ground level, connected to galvanised iron wire 4mm as earth wire by means of bolt, check nuts & washer of GI or steel connected to earth test point including earth strip from earth electrode to test point, Gl pipe 20 mm dia light grade as protection pipe and 20mm dia GI pipe light grade for watering pipe of required length including charcoal dust, common, salt, excavation and earth work, earth pit with PCC 1:3:6 type C 1 using 20mm graded stone aggregate, precast RCC cover 40mm thickness reinforced with 03 Nos TMT bars, 8 mm dia, both ways, funnel with wire mesh, testing and rest as shown in electrical plate No 3 of SSR Part -I complete all as specified and directed. (Note: (i) Excavation earth work and all connected items shall be deemed included in quoted unit rate. (ii) GI earth wire and GI protection pipe 20mm dia beyond 7.5m long shall be measured and paid separately.
Dismantling of old existing LT panels of any type/size including disconnecting of all connection and equipment’s complete all as specified and directed.
Taking down/ getting out carefully old unserviceable LT under ground cable from trench/duct or fixed on walls or laid in duct/ pipe of any size complete all as specified and directed.
M&L for painting of old LT panel including scraping of old paint and making good to damages dues to wear and tear including replacement of hinges, gaskets, locks complete all as specified and directed. (Note: somewhere during amendment size of Pase-I is required).
M&L cutting of PCC/Hard standing/WBM road not exceeding 20 cm in width not exceeding 30 cm in depth for passing of LT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Supply, laid in trench/ fixed with surface of wall / roof etc all in given location, jointing, thembling and glanding in suitable size , testing to LT cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armored electric power cable (heavy duty) with aluminum conductor 1100 Volts , grade cross section area 120 Sqmm x 3.5 core (earthed) complete all as specified and directed. (Note:- (i)The rate of saddles for cable fixing in wall, termination and connecting of cable including providing suitable size and nos of lugs by crimping as directed and specified shall be deemed to be included in the item rate. (ii) Excavation earthwork, sand cushioning and brick protection shall be measured and paid seperately under respective items))
All as per srl item No 127 above but 35 Sqmm, 3.5 core.
All as per srl item No 127 above but 25 Sqmm, 4 core.
All as per srl item No 127 above but 10 Sqmm, 2 core.
(B) Outgoing (a) MCCB 400Amps, 4 Pole, 415V , 36KA rupturing capacity, with fixed thermal magnetic release - 03 Nos. (b) MCCB 125 Amps, 4 Pole, 415V , 36KA rupturing capacity, with fixed thermal magnetic release - 02 Nos. (c) MCCB 100A, 4 Pole, 415V, 36KA repturing capacity, with fixed thermal magnetic release - 03 No. (d) MCCB 200A, 4 Pole, 415V, 36KA repturing capacity, with fixed thermal magnetic release - 01 No. (e) Air circuit breaker 800 Amp four pole manual draw out type with microprocessor MP-4 release for overload, short-circuit ground fault protection and neutral protection, suitable for rated system Voltage 690V ACB shall have Ics=Icu=Icw=50 KA, Icw rating shall be for 1 sec, release shall be provided with LED and LCD display suitable to show the last 20 trip history with data, date and time complete- 01 No (Note: MCCB & ACB shall be of same make and factory made & assembled panel shall be provided from manufacturer's only).
Supply installation of perforated GI cable tray 2mm thick , 300mm wide and 150mm height including laying of existing LT cable of any size and any capacity with fixing accessories (i.e angle iron, welding, Nut bolt of any other item required for fixing of cable tray) complete all as specified and as directed.
Excavation in trenches not exc 1.5m wide and not exc 1.5 m in depth for laying of cable, pole, foundation etc and getting out in soft/loose soil complete all as specified and as directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exc 25cm complete all as specified and as directed.
Removing excavated material not exc 50m and depositing where directed at a level not exc. 1.5m above starting point complete all as specified and as directed.
M&L sand cushioning to U/G cable in layers of 23 cm thick (8 cm before laying the cable and 15 cm thick after laying the cable, punned thickness shall be measured) in trenches complete all as specified and directed. (NOTE : Punned thickness of sand layers shall be measured and paid).
M&L brick sub class 'B' well burnt laid dry laid flat with width equal to the length of brick over cable protection complete all as specified and directed.
S&F 40mm bore, GI tubing, light grade with and including required fittings such as clamp made out by GI strip in size 32mm , Nut bolts etc for fixing to cable protection / laid in trenches, under road crossing, fixed on poles /walls etc complete all as specified and directed.
S&F GI strip 32x6mm buried in ground for earth continuity from earth electrode to test point terminal block complete all as specified and directed.
M&L earthing with galvanised cast iron earth plate of size 600 x 600 x 6 mm thick burred directly in ground not less than 2.25 Mtr below normal ground level, earth plate packed on all side with charcoal mixed wih salt to a thickness of 150 MM connected by GI earth strip of size 32 x 6mm thick soldered and rivetted to earth plate. GI earth strip will be protected by using 50 mm bore light grade GI pipe earth plate to steel tubular pole including flat iron clamp 25 x 3 mm including bolts nut and washers complete including watering GI pipe 20 mm dia light grade 2.5 Mtr long the earthing include PCC pit including necessary earth work and disposal of surplus soil to a distance not less than 50 Mtrs, chamber of PCC (1:4:8) type D 2 using 40 MM graded stone aggregate, coping shall be PCC(1:3:6) type C1 using 20 MM graded stone aggregate, RCC pit cover 50 MM thick (1:2:4) type B1 using 20 MM graded stone aggregate, reinforced with 8 MM MS bar at 80 MM C/C both way in lieu of CI pit cover and angle iron frame including flame funnel, wire mess, GI earth wire, 8 SWG under the earth and on the pole upto height of 1.5 Mtr shall be protected by 15 MM dia GI pipe (Light grade) GI pipe to be fixed with pole by means of 2 Nos flat iron clamp 25 x 3 MM size complete with bolts with nuts washers etc complete all as specified and shown in Electrical plate No 3 of MES SSR part -I 2009. (NOTE: 1. GI earth strip upto & including 7.5RM from the earth test point shall be deemed included in quoted unit rate. 2. GI earth strip beyond 7.5RM shall be measured and paid separately under respective items).
Supply and fixing single pole and neutral enclosure with a two pin and earth plug and socket complete with controlled by single pole MCB 32 Amps complete all as specified and directed.
Supply and installation, commissioning and testing of hi wall split type AC indoor and outdoor complete with cordless remote control unit and in built air ionizer and plasma filter for better indoor air quality with minimum 4 star rating and EER 3.2 of capacity as shown electric driven (single phase) 6000 K cal/hr (2 TR) outer unit shall be fitted with discharged cooled type rotary/scrolled type compressor operating on non CFC refrigerant R- 410A/R-22 including copper piping as required between both the units with suction pipe, discharge pipe and electric cable from innner unit to outer unit shall be properly included taped and covered with heavy duty half cut PVC and properly fixed on wall/ceilings etc including PVC pipes 15 mm dia fixed with proper slope for drain pipe of air conditioner the condenser coil of outdoor unit shall be of copper tubing complete all as specified and directed . (Make: Hitachi/Carrier/voltas/Daikin as approved by GE).
Supply and installation commissioning and testing of copper wound automatic volt stabilizer of capacity of 5 KVA automatic operation single phase neutrally air cooled indoor type and designed for input variation between 170 volt to 260 volt with output voltage at 230 volt with accuracy ± 2.5% complete all as specified and directed. (Make:V-guard/Vinitech/Aplab/Volina Microtech/AE as approved by GE)
SAXENA BANDHU
Bharat Sales Corporation
B.K.ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .