| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.7 LAccepted-AOC 29 IQBAL COLONY SONWAR SRINAGAR 190004 J K | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190004 | L1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | L2₹23.5 L+₹2.3 L (10.6%)Rejected-Finance DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹25.0 L+₹3.8 L (17.7%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹25.5 L+₹4.3 L (20.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹25.8 L+₹4.6 L (21.8%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹26.6 L
EMD Value
₹53,300
Closing Date
28 Nov 2020, 6:00 pmClosed
GE 864 EWS
GE 864 EWS SRINAGAR PIN - 190004
REPAIR AND CLEANING OF SEWAGE SUMP UG SEMI UG WATER SUMP AND MISC WORKS AT BB CANTT SRINAGAR
2020_MES_389355_2
864/WS-38/2020-21
Open Tender
Miscellaneous Works
Item Rate
270 days
BB CANTT SRINAGAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE 864 EWS
₹53,300
Yes
22 Jan 2021
9 Nov 2020
30 Nov 2020
9 Nov 2020
28 Nov 2020
16 Nov 2020
Amount
Desludging underground sewage sump of internal dia upto 10 meter and depth upto 6 meter and removing away sludge to a distance not exc than 50 metre from the starting point including burying sludge into pits and covered the pits with excavated material (soil) and including cleaning of pump house inside and surrounding at a distance upto 5 mtr radius all around by removing of all vegitation, bushes, mud, dirt, dust etc. and removing to a distance not exc 50 metre from the site including cleaning of pump and motors to match with existing surfaces and disinfecting the sump with chemical treatment (chemical aprroved by FOA / WHO) to make the sump totally clean bacteria free including applying wall primer to internal surfaces and applying cement based paint after scrubbing for all external surfaces, complete all as specified and directed by Engineer-in-Charge. Notes :- (a) Quoted rates shall be included for excavation of pits for burying sludge and removing of surplus spoil to a distance not exc 50 meter from the starting point. (b) T&P, plant, manpower, labour and transportation charges etc. shall be included in quoted rates.
Desludging underground sedimentation tank of capacity 25000 Gln and removing away sludge to a distance not exc 50 metre from the starting point including burying sludge into pits and covered the pits with excavated earth and including cleaning surrounding of tank to a distance of 5 mtr radius all around by removing of all vegitation, bushes, mud, dirt, dust etc. and removing to a distance not exc 50 metre from the site including cleaning of pump and motors, disinfecting the sump with chemical treatment (chemical aprroved by FOA / WHO) to make the sump totally clean bacteria free including applying wall primer to internal surfaces and applying cement based paint after scrubbing for all external surfaces, complete all as specified and directed by Engineer-in-Charge. Notes :- (a) Quoted rates shall be included for excavation of pits for burying sludge and removing of surplus spoil to a distance not exc 50 meter from the starting point. (b) T&P, plant, manpower, labour and transportation charges etc. shall be included in quoted rates.
Desludging underground final effluent tank of capacity 50000 Gln and removing away sludge to a distance not exc 50 metre including burying sludge into pits and covered the pits with excavated earth and including cleaning surrounding of tank to a distance of 5 mtr radius all around by removing of all vegitation, bushes, mud, dirt, dust etc. and removing to a distance not exc 50 metre from the site including cleaning of pump and motors, disinfecting the sump with chemical treatment (chemical aprroved by FOA / WHO) to make the sump totally clean bacteria free including applying wall primer to internal surfaces and applying cement based paint after scrubbing for all external surfaces, complete all as specified and directed by Engineer-in-Charge. Notes :- (a) Quoted rates shall be included for excavation of pits for burying sludge and removing of surplus spoil to a distance not exc 50 meter from the starting point. (b) T&P, plant, manpower, labour and transportation charges etc. shall be included in quoted rates.
Desludging underground oxidation ditch and removing away sludge to a distance not exc 50 metre including burying sludge into pits and covered the pits with excavated earth and including cleaning surrounding of tank to a distance of 5 mtr radius all around by removing of all vegitation, bushes, mud, dirt, dust etc. and removing to a distance not exc 50 meter from the site including cleaning of pump and motors, disinfecting the sump with chemical treatment (chemical aprroved by FOA / WHO) to make the sump totally clean bacteria free including applying wall primer to internal surfaces and applying cement based paint after scrubbing for all external surfaces, complete all as specified and directed by Engineer-in-Charge. Notes :- (a) Quoted rates shall be included for excavation of pits for burying sludge and removing of surplus spoil to a distance not exc 50 meter from the starting point. (b) T&P, plant, manpower, labour and transportation charges etc. shall be included in quoted rates.
Dewatering underground drainage sump of internal dia upto 9 metre and depth upto 5 metre including cleaning of sump and pump house inside and surrounding at a distance of 5 mtr radius all around by removing of all vegitation, bushes, mud, dirt, dust and other foreign material etc. and removing to a distance not exc 50 metre from the site including cleaning pump and motors and applying disinfecting the sump with chemical treatment (chemical aprroved by FOA / WHO) to make the sump totally clean bacteria free including applying wall primer to internal surfaces and applying cement based paint after scrubbing for all external surfaces, complete all as specified and directed after preparation of surface and burying of foreign material in pits and covered the pits with excavated soil, complete all as specified and directed by Engineer-in-Charge. Notes :- (a) Quoted rates shall be included for excavation of pits for burying sludge and removing of surplus spoil to a distance not exc 50 meter from the starting point. (b) T&P, plant, manpower, labour and transportation charges etc. shall be included in quoted rates.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation of poles / laying of underground cables / laying of pipe etc. and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm thick each, complete all as specified and directed by Engineer-in-Charge.
Removing of surplus soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge.
M&L for clean dry sand, laid in trenches / ducts for bedding and cushioning to cable, including spreading and levelling, complete all as specified and directed by Engineer-in-Charge. Notes :- (a) Consolidated / panned sand shall be measured and paid. (b) Sand shall be fine sand (use for plastering work).
Supply and Laying bricks, old size, sub class 'B' for protection of cable, laid dry, flat over the cable, complete all as specified and directed by Engineer-in-Charge.
M&L for 40mm bore GI pipe, light grade for protection of cable along the pole / across the road crossing / passing through culvert etc., complete all as specified and directed by Engineer-in-Charge.
Supply, Laying, Testing & Commissioning of LT XLPE insulated, PVC sheathed, armoured, heavy duty cable, 1100 Volts grade using stranded aluminium conductor, cross-sectional area 185 Sqmm 3.5 core, confirming to IS specifications including taking out existing unserviceable cable, complete all as specified and directed by Engineer-in-Charge. Make: Polycab / CCI / Finolex / Gloster
All as per Srl item No. 12.00 above but cross-sectional area 50 Sqmm 3.5 core. Make: Polycab / CCI / Finolex / Gloster
All as per Srl item No. 12.00 above but cross-sectional area 16 Sqmm 4 core. Make: Polycab / CCI / Finolex / Gloster
All as per Srl item No. 12.00 above but cross-sectional area 10 Sqmm 2 core. Make: Polycab / CCI / Finolex / Gloster
S&F in position hot dip galvanised octagonal pole of 6 mtr height with bottom outer dia not less than 130mm and top outer dia not less than 70mm and sheet thickness not less than 3mm, fabricated from high tensile steel, conforming to BS EN ISO-1461 to grade S 355 JO complete with flush door, three phase and neutral busbars mounted on backlite sheet, SP MCB 6 Amps rating for controlling individual light including double arm sward type hot dip galvanised (exposed cut and welded portion to be hot dip galvanised) street light bracket not less than 1.0 mtr long and vertical portion in octagonal shape matching to the pole design, complete all as specified and directed by Engineer-in-Charge. Make : Crompton / Bajaj Pole type BOP-6030 / Surya Notes :- (a) Fondation of octagonal pole will be as per manufacturer's drawing & design. (b) Rates shall be included for RCC steel reinforcement and formwork as per manufacturer's drawing and design and required at site. (c) Earth work shall be measured and paid separately under respective items.
S&F LED type street light fitting 72 watt, pressure die-cast, aluminum housing, heat resistance toughened glass, IP-66 protection with lens & better optics for uniform distribution with electronic driver including connection with 3 Core 1.5 Sqmm copper conductor cable from junction box / over head line including taking down old existing street light, complete all as specified and directed by Engineer-in-Charge. Make :- Crompton Cat Part No. LSTP-72-CDL or technocommercially equivalent in Havells / Philips / Wipro
S&F in replacement digital voltmeter of size 96mm x 96mm, 0-500 Volts, AC, complete all as specified and directed. Make :- L&T / Rishabh / Siemens / HPL
S&F in replacement digital ammeter of size 96mm x 96mm, 0-100 Amps, AC, complete all as specified and directed. Make :- L&T / Rishabh / Siemens / HPL
S&F in replacement Phase indicating lamps, LED type, RYB, complete all as specified. Make :- L&T / Rishabh / AE
S&F in replacement die-cast resin CT for digital Ammeter, ratio of CT, complete all as specified. Make :- L&T / Rishabh / Siemens
M&L for wiring of voltmeter or ammeter with copper conductor single core 1.5 Sqmm wire, complete all as specified.
M&L for PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregates) as in foundation of electric poles, struts, PCC blocks and fair finish to exposed surfaces without using extra cement, complete all as specified and directed by Engineer-in-Charge.
M&L for copper conductor multistranded, FR, PVC sheathed, single core, 25 sqmm wire including copper thimble, complete all as specified and directed by Engineer-in-Charge. Make :- Havells / Polycab / Anchor
M&L for copper conductor multistranded, FR, PVC sheathed, single core, 50 sqmm wire including copper thimble, complete all as specified and directed by Engineer-in-Charge. Make :- Havells / Polycab / Anchor
M&L for FR, multistranded, PVC unsheathed, 1100 volts grade cable, single core, copper conductor of size 16 Sqmm including copper thimble, complete all as specified and directed. Make :- Havells / Polycab / Anchor
S&F fully automatic citation, fully automatic star delta starter with citation M contactor & Pneumatic timers for 75 HP 3 Phase overload relay, range 37.6-60.0 Amp, conactor rating 40 Amps, complete all as specified and directed by Engineer-in-Charge. Make :- BCH Cat Part No. NASACT2LEEM or technocommercially equivalent make of L&T / Siemens / ABB
S&F fully automatic star delta starter in SS enclosure with citation fully automatic star delta starter with NHD contactor & Pneumatic timers for 15 HP 3 Phase overload relay, range 13.2-20.0 Amp, conactor rating 16 Amps, complete all as specified and directed by Engineer-in-Charge. Make :- BCH Cat Part No. NASAKLEN or technocommercially equivalent in L&T / Siemens / ABB
S&F fully automatic star delta starter in SS enclosure with citation fully automatic star delta starter with NHD contactor & Pneumatic timers for 3 HP 3 Phase overload relay, range 2.4-3.8 Amps, contractor rating 16 Amps, complete all as specified and directed by Engineer-in-Charge. Make :- BCH Cat Part No. NASANLEN or technocommercially equivalent in L&T / Siemens / ABB
S&F in replacement time switch, 240 Volts, 16 Amps rating with contactor 2 pole 240 Volts 40 Amps - 01 No, MCB SP 240 Volts 0.5 Amps - 01 No and MCB SPN 240 Volts 16 Amp - 01 No, fixed in sheet metal enclosure 2mm thick of size 40cm x 40cm x 10cm duly painted with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and fixing arrangements by means of 25x3mm MS flat clamps, nuts, bolts and washers, complete all as specified and directed by Engineer-in-Charge. Make of time switch :- L&T Cat Part No. 2DDT0 / Legrand Cat Part No. 412657 or euivalent in Siemens Make of contactor :- L&T / Legrand / Siemens Make of MCB :- L&T / Legrand / Siemens
S&F in replacement Off load change over switch, cubical type, 4 Pole of rating 400 Amps, confirming to IS-13947 (Part 3) with rotary handles, complete all as specified. Make :- Havells Cat Part No. IHCFFE0400 or technocommecially equivalent in L&T / Standard / Siemens
S&F single shaded reflective sign board of high intensity reflective sheet, computer cut back ground of sky blue/green colour and white letters (letters and diagrams to be written/printed on the board shall be provided by EIC), mounded on harden alloy aluminium sheet 2mm thick fixed on angle iron frame and supported by angle iron/square tubes (As directed by EIC), complete all as per manufacterer's instructions including taking out/down old unserviceable sign boards of any type including supports, complete all as specified and directed by Engineer-in-Charge. Note :- Rates shall be included for angle iron/square tube frames, supports, nuts and washers etc.
Dismantling plain or corrugated steel sheeting of any gauge, thickness including Nainital or similar pattern roof coverings, complete all as specified and directed by Engineer-in-Charge.
S&F 0.63mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap with grade of zinc coating as in roofs, walls etc., fixed with 'L' or 'J' type or cranked hook & bolts in lieu of screws, complete all as specified and directed by Engineer-in-Charge.
S&F 0.63mm thick plain, galvanised, mild steel sheeting as in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating, fixed with 'L' or 'J' type or cranked hook & bolts, complete all as specified and directed by Engineer-in-Charge.
M&L for rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., confirming to Fe-410-W, Grade E-250, quality 'A' including dismantling existing old wrought iron or framed structure, complete all as specified and directed by Engineer-in-Charge.
M&L for 10mm thick rendering in CM 1:4 on stone masonery or other than fair finish of brick work surfaces, finished even and smooth without using extra cement including taking down existing plaster, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces of walls including washing, rubbing down and scraping of old paint and applying two coats of cement paint, complete all as specified and directed by Engineer-in-Charge.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc 6 mtr mean radius, built in CM 1:6 including demolition existing brick work or stone masonery, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new steel surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
M&L for writing letters or figures (Nos, Block, Roman, Italic or Indian) not exc 30cm high with synthetic enamel black paint, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old painted wood or wood based surfaces of any description not otherwise described, over 10cm width or girth with one coat of enamel ordinary paint, complete all as specified and directed by Engineer-in-Charge.
Dismantling of scrubber trolley system & rewinding of electric motor of capacity 3 HP, 415 Volts with existing super enamled copper winding, replacement of chain pulley system with chain, repair of reduction gear system, complete replacement of worn out / unserviceable parts of system and re-assembling the complete after repair and testing on compeletion, complete all as specified and directed by Engineer-in Charge. Note :- Cost of all worn out spare parts shall be included in quoted the rates.
M&L for cross arms, bracings, supports, clamps and back plates, fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and including two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 150mm bore sluice valve, flanged, long body type of cast iron, both ends flanged and drilled, class-I conforming to IS-14848 : 2000 with pressure rating PN 1.6 with spindle and iron wheel head with GI nuts, bolts and washers of suitable size, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 100mm bore cast iron Non return valve, flanged ends, heavy duty suitable for 100mm bore pipe including 6mm thick 2 Nos rubber insertion ring, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 150mm bore cast iron Non return valve, flanged ends, heavy duty suitable for 100mm bore pipe including 6mm thick 2 Nos rubber insertion ring, complete all as specified and directed by Engineer-in-Charge.
Dismantling of reduction gear rotor mechanism and replacement of aerator rotor mechanism, shaft with MS framed work as per sample, replacement of rubber & steel coupling as per sample, dismantling and disconnecting 15 HP reduction gear pump set from the electric motor and re-assembling the pump on existing foundation and complete with motor after repair /overhauling including filling of gear oil, complete replacement of wornout / unserviceable part of sytem and re-assembling the complete after repair and testing on compeletion, complete all as specified and directed by Engineer-in-Charge. Note :- Cost of all worn out spare parts shall be included in quoted the rates.
M&L for cleaning of RCC Over Head Reservoirs / UG & Semi UG sumps / Jack wells / filter beds / clarifier for the following capacity as described below :- (a) Before start the cleaning of RCC Over Head Reservoirs / UG & SUG Sumps / Jack wells / Filter beds / clariflocculator are to be disconnected from all inlets/outlets of pipeline and plug with suitable fitting. After cleaning, pluged line should be washed out and connected to the all inlets/outlets of pipe line as per existing position. (b) The inner surface of the walls and ceiling of the tank shall be cleaned with high pressure jet pump after emptying the water in the tank. (c) After thorough cleaning of the tank, the cleaning water and sludge is to be removed by using pump and the sludge has to be disposed off at a place as directed. (d) After removing the sludge from tank, the tank shall be cleaned thoroughly by using high pressure water pump first and again the floor and inner surfaces of the tank shall be cleaned by using a industrial vaccum cleaner and the tank shall be made fully dirt free. (e) After made the tank dirt free, the inner surfaces of walls and ceiling of the tank shall be treated with anti bacterial agents. (f) After the treatment as mentioned at (e) above, the inner surfaces of walls and ceiling shall be treated with UV Radiator. (g) After complete treatment, writing of "Tank capacity" & ''Date of cleaning'' and ''Due date of cleaning'' on wall including applying two coats of white washing to external surfaces, complete all as specified and directed by Engineer-in-Charge. Location :- Semi underground drinking water sump 2 Lakh gallon capacity at Old BP Tank / Range road / New BP tank.
All as per Srl item No. 52.00 here-in-before but Semi underground drinking water sump 100000 gallon capacity at Atal Colony / 11 FSG.
All as per Srl item No. 52.00 here-in-before but Semi underground drinking water sump 75000 gallon capacity at Holiday home / Arty Bde.
All as per Srl item No. 52.00 here-in-before but Semi underground drinking water sump 50000 gallon capacity at 'R' Centre.
All as per Srl item No. 52.00 here-in-before but Semi underground drinking water sump 40000 gallon capacity at SS Colony.
All as per Srl item No. 52.00 here-in-before but Semi underground drinking water sump 20000 gallon capacity at 20 RR. NOTES FOR SRL ITEM NOS. 52.00 to 57.00 ABOVE :- (a) All rates shall be included draining of water with and by mechanical equipment and working in water and mud etc. (b) Rates shall be included all safety precautions which shall be taken while working in cleaning of tank and contractor or his Engineer shall be available during execution of Job. (c) Lighting arrangment if required will be provided by the contractor at his own cost and amount quoted for that shall be deemed in the unit quoted rates, electricity and diesel shall not be provided by the Dept. (d) Contractor shall not be allowded more than one day to do the work inside the tank to prevent interruption of water supply to users.
M/S ASHRAF CONSTRUCTIONS
M/S Khan Hussain & Co.
ALCO ENGINEERSPVT LTD
M/S Bilal Construction
M/S Noor Mohammad Shalla
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .