Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC 165 UTTAR KASTODANGA ROAD KOLKATA 700 061 | KOLKATA | KOLKATA | WEST BENGAL | 700061 | L1 | Accepted-AOC Being a lowest bidder and reasonable | |
| 2 | L2₹36.1 L+₹4.8 L (15.3%)Rejected-Finance 42 43A VIDYA SAGAR SARANI PALLY BARISHA KOLKATA 700 008 | KOLKATA | WEST BENGAL | 700008 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹36.4 L+₹5.1 L (16.3%)Rejected-Finance 34 C R AVENUE JABAKUSUM HOUSE 3RD FLOOR ROOM NO 312 KOLKATA 700 012 | KOLKATA | WEST BENGAL | 700012 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.3 L+₹6.0 L (19.1%)Rejected-Finance SHIVSHAI PUNARVASAN PRAKALP BLDG NO 10 ROOM NO 115 MAHARASHTRA NAGAR MANKHURD E MUMBAI 400088 | MUMBAI SUBURBAN | MAHARASHTRA | 400088 | L4 | Rejected-Finance Other than lowest |
Tender Value
₹37.3 L
EMD Value
₹75,600
Closing Date
4 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (FW) Kolkata
D9 Commissariat Road Hastings Kolkata 700022
SPL REPAIR TO REPLACEMENT OF STEEL TUBULAR POLES OF STREET LIGH WITH ALLIED WORKS AT FORT WILLIAM UNDER GE (FW) KOLKATA
2023_MES_620348_2
8177/E8
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
GE(FW) Kolkata
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
g
₹75,600
15 Jan 2024
18 Nov 2023
5 Dec 2023
18 Nov 2023
4 Dec 2023
20 Nov 2023
Amount
Excavation in trench not exceeding 1.5 M wide and not exceeding 1.5M in depth for sewage line, manhole, for laying of UG Cable/poles/stays etc., not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
Excavation in trenches not exc 1.5 metre width and not exceeding 1.5 metre in depth in road/hardstanding and getting out complete all as specified and as directed. Note: Quoted rate shall be deemed to include making good damaged road / hardstanding to match the existing specifications after laying cables/pipe lines as directed.
Returning, filling in, including spreading, watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and as directed.
Removing excavated material to a distance n exc 50M and deposited where directed at a level n. exc 1.5M above the starting point complete all as specified and as directed.
M&L for sand cushioning/sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and as directed. (NOTE: Punned thickness shall be measured for payment)
M&L bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Laying only old bricks (retrieved during taking out of cable) in trenches above sand cushioning for cable protection complete all as specified and as directed.
Supply and fixing 40 mm bore galvanized iron pipe (light grade) with all fittings, laid in trenches or under roads/ floors/ culverts etc., in repairs, complete all as specified and as directed by the Engineer-in-charge.
Taking down unserviceable LT cable for repair/ replacement etc (from cable duct/underground trench / pole), stacking properly (cable, pipe and bricks) complete all as directed by the Engr-in-Charge of the following cross - sections :- (Note :- Necessary earth work to be measured and paid separately.
10 Sqmm 4 Core to 16 Sqmm, 4 Core
25 Sqmm to 50 Sqmm, 3.5 Core
Supply, Laying and testing XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall/passing through pipe/pole complete of the following sizes and cross sectional area :- (Note : Necessary earth work to be measured and paid separately).
10 Sqmm, 2 Core
35 Sqmm, 3.5 Core
50 Sqmm, 3.5 Core
Relaying of XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole. (retrieved against item No 1 above) incl necessary aluminium thimbles, jointing and testing complete all as specified and directed for the following sizes and cross sectional area :- (Note :- Necessary earth work to be measured and paid separately.
10 sqmm 4 core to 16 Sqmm, 4 Core
25 Sqmm to 50 Sqmm, 3.5 core
Dismantling of broken / dislodged pre-stressed concrete poles / steel tubular poles, of any description including earthwork for removal of concrete foundation, keeping serviceable poles in safe custody for re-use and removal of unserviceable poles from site, complete all as specified and directed.
Supply and fix Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws fixed with MS clamp 40 x 6 mm and 2 set with nut & bolt as specified type 410 SP-31 (9 Meter long) duly painting with two coats of aluminium paint over a coat of red oxide primer on exposed surface and one coat of black bituminous paint on embedded surface incl writing of Pole Numbers etc., and marking of two black & two yellow strips with synthetic enamel paint upto 1.2 Mtr height and making good disturbed surface complete all as specified and directed.
M&L for replacement of Pole Mounted Junction Box 254 x 180 x 111mm, having insulated and made out of thermoplastic Polycarbonate with glass fibre reinforced, rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529, IK 07, weather proof for outdoor installation (with knockouts for cable entry) having Gasket Material shall be Polyurethane and the Gasket shall be internally embedded, Tested at 650°C, with Plastic Mounting Bracket, Din Rail, Mild Steel Flat Iron Clamp, Nuts, Bolts and Washers, with MCB SP 6 Amps, 'B' Curve, 10 KA, complete all as specified and as directed. MAKE: CAPE Electric Model No. TKPS 2518 - 11M or HENSAL cat Pt No. KF 2525B or equivalent SPELSBERG/ RITTAL/ SCHNEIDER
M&L for replacement of GI Pipe Bracket made out of Galvanised Iron Tubing 32/40mm bore (dia), light grade, 1.50 Metre long fixed with 02 sets of flat iron clamp of size 30mm x 5 mm, with bolts, nuts and washers of suitable size including applying two coats of aluminium paint over a coat of red oxide zinc chrome primer incl taking down existing bracket complete all as specified and as directed by the Engr-in-Charge.
M&L for replacement of Galvanised Steel Tubing Pipe 50mm bore (dia), light grade, length 0.60 mtr (02 Nos) having 50 Cm with long Bends, Each for Incoming and Outgoing Cables, grouting in Cement Concrete, complete all as specified and as directed. NOTE : Cement Concrete will be measured and paid for separately under appropriate Item.
S&F in replacement of PVC insulated multistranded copper conductor wire, 1.5 Sqmm 3 Core, round flexible for connection of light fittings, complete all as specified and as directed.
Material and labour for PCC (1:4:8) type D-2 using 40 mm graded crushed stone aggregate as in foundations of poles, as mass concrete, complete all as specified and directed.
Material and labour for PCC (1:3:6) type C-2 using 20 mm graded crushed stone aggregate as in plinth courses, string courses, etc., complete including slightly rounded or chamfered for GI tubing post for ait termination rod etc., including using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
Material and labour for PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate as in coping of poles / pipes / strip alignment etc using necessary formwork and finishing the exposed surfaces even and smooth without using extra cement complete all as specified and directed.
S&F in repairs LED Street Light fitting of 60 Watts capacity, in high pressure die cast aluminium housing with prismatic polycarbonate modular secondary lens optics with integrated constant current electronic driver, top opening driver cover, IP66 ingress protection, impact resistance of IK07 complete all as specified and directed and complying with the following specifications:-. (a) minimum system efficacy 120 lumen/watt (b) CRI not less than 70, (c) THD < 10% (d) Power Factor not less than 0.90 (e) having in built short circuit and surge protection upto 4 kV (f) having 10 KV external surge protection (for 45 watt & above) (g) colour temperature not less than 5700 degree K (h) life not less than 50000 hours of operation
Taking out carefully existing serviceable light fitting of any wattage from poles and clean thoroughly the complete set and re-fixing the same on new or re-fixed poles, including necessary connection, testing complete all as specified and as directed by Engr-in-Charge.
S&F in repairs LED Flood light fitting 80 Watt 230 V AC outdoor type with high pressure die cast housing, toughened glass, heat resistant complete with individual LEDs with secondary lens optics with IP66 ingress protection, 4 kV in-built and 10 kV external surge protection with minimum efficacy 120 lm/W and CCT 5700 K complete all as specified and directed. (Make : BAJAJ Model No. PRAZE F 96L WH NB-A5 TG SD or Eqv of PHILLIPS / CROMPTON / HAVELLS / JAGUAR)
S&F in repairs LED Bollard light fitting 10 Watt 230 V AC outdoor type with IP 65 rating, surge protection 4 KV, CCT 5700K, CRI > 70, complete all as specified and directed. (Make : CROMPTON Model No. LBLSR-10-CDL or Eqv of PHILLIPS / BAJAJ / HAVELLS / JAGUAR)
S&F in repairs LED Post Top light fitting 15 Watt 230 V AC outdoor type with IP 65 protection, complete all as specified. (Make : HAVELLS Model No. CORALMINIPT15WLED830 PSYMTOPC or Eqv of PHILLIPS / BAJAJ / CROMPTON / JAGUAR)
Taking out carefully interlocking paver block, of any size or shape and re-laying in the same position after removing all vegetation, algae, grass etc., laid in proper slope and gradient over sand cushioning, complete all as specified and directed. Note: Sand, if required for correction of cushioning level shall be measured and paid separately. Replacement of brocken paver blocks shall be separately as "Supply only"
Supply only Machine pressed precast concrete interlocking paver block with grey cement and pigment of any shape and size as approved by GE conforming to IS-15658-2006 of 60 mm thickness, M-35 grade with 6 mm top layer of coloured rubberised anti abrasive material complete all as specified and directed.
M&L for preparation of newly plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed.
Note: Schedule of credit (SCHEDULE OF CREDIT) amount of Rs ________ mentioned on Page No ____ shall be deducted from the total quoted amount of BOQ.
SANTOSH INTERNATIONAL
Tirupati Buildcon Pvt. Ltd.
AZIM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .