Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC NO S 7 2ND CROSS 2ND MAIN KEB LAYOUT SANJAYANAGAR BANGALORE 560094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC L1 | |
| 2 | L2₹38.5 L+₹2.3 L (6.47%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹43.0 L+₹6.8 L (18.8%)Rejected-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L3 | Rejected-AOC L3 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Nov 2024, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore-63
REPAIR OF WINDOW TYPE ACS, SPLIT ACs, WATER COOLERS, REFRIGERATION AND DEEP FREEZER AND REPAIR/ REPLACEMENT, CLEANING/REPAIR OF FOUNTAIN, SERVICE TANKS AND MISC ITEMS AT AFS YELAHANKA
2024_MES_681081_1
8313/E8
Open Tender
Civil Works
Item Rate
90 days
Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹90,000
Yes
7 Dec 2024
24 Oct 2024
23 Nov 2024
24 Oct 2024
21 Nov 2024
7 Nov 2024
Amount
Material and Labour for servicing of spilt type AC indoor/outdoor of capacity 1/1.5/2.0 TR of any make and type including following item of works: (a) Cleaning of complete unit including cooling coil condenser, Fan (Outdoor unit), blower etc. (b) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc. (c) Checking of refrigerant piping and carrying out necessary repairs/replacement to copper tubing and insulation to copper tubing. (d) Checking of all components/accessories for their serviceability and replacement of defective components/accessories (e) Greasing and oiling of fan motor Note: (i) Replacement of unserviceable items wrt (d) above shall be measured and paid separately including relevant items.
All as per item No. 1 above but capacity 3 TR (2x1.5 TR) with 01 No outdoor unit and 02 Nos indoor unit
Material and Labour for servicing of Window AC 1/1.5/2.0 TR capacity including following items of works.:- (a) Cleaning of complete unit including cooling coil condenser, Fan(Outdoor unit), blower, etc as directed by Engineer-in-Charge. (b) Checking of Electrical wiring and carrying out necessary repairs/replacement along with lugs, clamps, soldering etc. (c) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. Note : (i) Replacement of unserviceable items wrt (d) above shall be measured and paid separately including relevant items . (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer as directed by Engineer-in-charge functionality of AC is deemed to be included in unit rate
Maintenance/repairs and testing of Deep freezer of capacity 300/320/500 ltrs including following items of works.:- (a) Checking of Electrical wiring and carrying out necessary repairs/replacement alongwith lugs, clamps, soldering etc. (b) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. Note: (i) Replacement of unserviceable items wrt (b) above shall be measured and paid separately including relevant items. (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer for functionality of Deep Freezer is deemed to be included in unit rate.
Maintenance/repairs and testing of Water coolers of capacity 30 to 150 ltrs including following items of works: (a) Checking of Electrical wiring and carrying out necessary repairs/replacement alongwith lugs, clamps, soldering etc. (b) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. (c) Cleaning of water storage tank. Note: (i) Replacement of unserviceable items wrt (b) above shall be measured and paid separately including relevant items. (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer for functionality of water cooler is deemed to be included in unit rate.
Maintenance/repairs and testing of Refrigerators of capacity 165 to 360 ltrs including following items of works.:- (a) Checking of Electrical wiring and carrying out necessary repairs/replacement alongwith lugs, clamps, soldering etc. (b) Changing of all components/accessories for their serviceability and replacement of defective components/accessories. (c) Cleaning of water storage tank. Note: (i) Replacement of unserviceable items wrt (b) above shall be measured and paid separately including relevant items. (ii) Any other minor work such as welding/brazing and replacement of minor parts such as nut, bolt, washer for functionality of refrigerator is deemed to be included in unit rate .
Supply & fixing of new filter drier for 1.5 TR Split type AC capacity complete all as specified and directed
Supply & fixing of new Air filter for 1.5 TR Split type AC capacity complete all as specified and directed
Supply and fixing of new filter drier for 3 TR Split type AC capacity complete all as specified and directed
Supply and fix in repair of Plastic filter for window type AC 1.0/1.5/2.0 ton capacity complete all as specified and directed
Supply and fix in repair new Air filter for 2.0 TR Split type AC complete all as specified and directed
Supply and fix in repair of new filter drier for 2.0 TR Split type AC complete all as specified and directed
Supply and replacement of remote suitable for 1.5 TR Split type AC capacity complete all as specified and directed
Supply and replacement of remote suitable for 2.0 TR Split type AC capacity complete all as specified and directed
M&L for repairs to remote mother board for 1/1.5 TR Split type AC capacity complete all as specified and directed
M&L for repairs to remote mother board for 2/3 TR Split type AC capacity complete all as specified and directed
Supply and fix in repairs hermetically sealed reciprocating compressor of capacity 1.5 Ton suitable for installed in Window type Air conditioner complete all as specified and directed Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and fix in repairs hermetically sealed reciprocating compressor of capacity 1.5 Ton in exchange of unserviceable suitable for installed in 1.5 Ton Split type Air Conditioner complete all as specified and directed Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of hermetically sealed reciprocating compressor (sealed unit) of capacity 2.0 Ton in exchange of unserviceable suitable for installed in 2.0 Ton Split type Air conditioner complete all as specified and directed Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of hermetically sealed reciprocating compressor (sealed unit) of capacity 3.0 Ton in exchange of unserviceable suitable for installed in 3.0 Ton Split type Air conditioner complete all as specified and directed Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of hermetically sealed reciprocating Compressor (Sealed unit) suitable for 150 Ltr. Water Cooler complete all as specified and directed Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of hermetically sealed reciprocating Compressor (Sealed unit) suitable for 40/80 Ltr. Water Cooler complete all as specified and directed Make : Kirloskar/Hitachi/GMCC/LG/Bluestar.
Supply and replacement of hermetically sealed reciprocating compressor (sealed unit) with relay suitable for refrigerator of capacity 310/315/320/325 litres complete all as specified and directed Make of compressor: TECUMESH / KIRLOSKAR / GODREJ
All as per item No. 18 here-in-before above but for capacity of 180/230 ltrs capacity.
Supply and fix in repair Running capacitor 36 MFD 230 volts, 50 Hz complete all as specified and directed Make : KELTRON / USHA / SIEMENS
All as per item No 13 above but capacity of 45 MFD 230 volts, 50 Hz complete all as specified and directed Make : KELTRON / USHA / SIEMENS
Supply and fix in repair Running capacitor 25 MFD 230 volts, 50 Hz complete all as specified and as directed Make : KELTRON / USHA / SIEMENS
Supply and fix in repair Starting capacitor 60 to 80 MFD 230 volts, 50 Hz complete all as specified and directed Make : KELTRON / USHA / SIEMENS
Supply and fix in repair Capacitor 4 MFD, 230 volts, 50 Hz complete all as specified and directed. Make : KELTRON / USHA / SIEMENS
Supply and fix in repair Capacitor 2.5 MFD, 230 volts, 50 Hz complete all as specified and directed Make : KELTRON / USHA / SIEMENS
Supply and fix in repair Starting capacitor 100 to 120 MFD 230 volts, 50 Hz complete all as specified and directed Make : KELTRON / USHA / SIEMENS
Supply and fixing of new running capacitor for 2 x 1.5 TR Split type AC complete all as specified and directed
Supply and fix in repair of relay suitable for Window type AC 1.0/1.5/2.0-ton capacity complete all as specified and directed Make : SRIRAM/Ranutrol.
All as per item No 29 above but split type A/C of capacity 1.5/2.0 TR complete all as specified and directed by Engineer-in-Charge. Make : SRIRAM Model SR 1622 or equivalent of Ranutrol.
Supply and fix in repair over load relay suitable for Water cooler 40 to 60 ltr complete all as specified and directed
Supply and fix in repair box type relay suitable for refrigerator 165 to 310 ltr capacity complete all as specified and directed Make : SRIRAM / Ranutrol/ Indfoss.
Supply and fix in repair relay 30 Amps capacity suitable for 4/5 KVA stabilizer complete all as specified and directed
Supply and fix in repair of Thermostatic switch with knob suitable for window type AC 1.0/1.5/2.0 TR all as specified and directed. Make : INDFOS / RENUTRAL/Sriram
Supply and fix in repair suction and discharge valve for 1.5/2.0 TR spilt type A/C complete all as specified and directed
Supply and fix in repair Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.0/1.5/2.0 TR Window type Air Conditioner of various makes as per sample all as specified and directed.
Repairs to Blower/Fan motor for 3 TR (2 x 1.5 TR) Split type AC complete all as specified and directed
Supply and fix in repair of Fan motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR Split type Air Conditioner of various makes as per sample all as specified and directed
Supply and fix in repair Fan motor, single phase 230 Volts 1500 RPM, suitable for 1.5 TR Split type Air Conditioner of various makes as per sample all as specified and directed.
Supply and fix in repair Fan Motor Single phase,230V for water cooler complete all as specified and directed
Supply and fix in repair Blower Motor, single phase 230 Volts 1500 RPM, suitable for 2.0 TR split type Air Conditioner (indoor unit) complete all as specified and directed
Supply and replacement of Blower Motor, single phase 230 Volts 1500 RPM, suitable for 1.5-ton split type Air Conditioner (indoor unit) complete all as specified and directed
Supply and fixing of new fan blower for 3 TR (2 x 1.5 TR) Split type AC complete all as specified and directed
M & L for Rewinding of electric fan motor of 1.0/1.5/2.0-ton window type AC 1400 RPM 220 V 50 C/S with super enamelled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as specified and directed.
M & L Rewinding of electric fan motor of 1.5/2 ton split type AC (outdoor unit) 1400 RPM 220 V 50 C/S with super enamelled copper wire of suitable size including, replacement of shaft, bushes, capacitor and testing on load all as specified and directed.
Supply and fixing of new swing motor for split type AC 1.5/2.0 Ton capacity complete all as specified and directed
Supply and fix in repair of front grill suitable for 1.0/1.5/2.0 ton window type Ac make Carrier Air con/Usha Sriram/LG complete all as per site requirement and as per sample complete all as specified and directed.
Supply and replacement of PCB suitable for 1.5/2 TR split type ACs as per site requirement and as per sample all as specified and directed. Make : LG/Carrier/Blue star
All as per item No 13 above but for 3 TR split type ACs complete all as specified and as directed
Supply and replacement of contactor suitable for LG/Bluestar/Voltas/Carrier/Hitachi make Split type AC capacity 1.5/2.0 TR all as specified and directed.
Supply and replacement of evaporator coil for indoor unit of 1.5 TR Split AC complete all as specified and directed
Supply and replacement of condenser coil for outdoor unit of 1.5 TR Split AC complete all as specified and directed
Supply and replacement of evaporator coil for 2 TR Split AC complete all as specified and directed
Supply and replacement of condenser coil for outdoor unit of 2 TR Split AC complete all as specified and directed
Supply and replacement of blower for indoor unit of Split AC 1.5/2 TR complete all as specified and directed
Supply and replacement of fan blade suitable for outdoor unit of Split type AC capacity 1.5/2.0 as per sample complete all as specified and directed
Supply and replacement of fan blade suitable for window type AC capacity 1.0/1.5/2.0 as per sample complete all as specified and directed
M&L for disconnecting electrical connection and dismantling/ taking out indoor and outdoor unit of split type air conditioning of any make and capacity from any place and installation, commissioning and testing to another location including transportation from existing bldg to another bldg including making good the disturbed surfaces complete all as specified and directed
Supply, fixing, jointing and testing copper tubing with nominal dia meter of 0.25 inch of suitable thickness for liquid line to connecting out door condensing unit and fan coil unit (for 1.5/2.0 TR split AC) complete all as specified and directed.
Supply, fixing jointing and testing copper tubing with nominal dia meter of 0.5 inch and 0.8 inch thickness including expanded polythene foam insulation tubing for external insulation of suction line for connecting outdoor condensing unit and fan coil unit (For 1.5/2.0 TR split AC) complete all as specified and directed
Supply and fixing new Thermostat for water cooler storage type of capacity 30/40/60/120/150/ 180ltr/hour all as per sample all as specified and directed.
Material and Labour for of base stand for fan motor from 2 mm thick MS sheet by welding and required nut bolts/washers all as specified and directed.
Supply and fix in repair Fan Motor blade complete all as specified and directed
Supply and replacement of 15mm dia Push type C.P. bib cock for water cooler complete all as specified and directed Make : L & K/Leader
Supply and fix in repair float valve PVC for water coolers as per sample complete all as specified and directed
Supply and fix in repair water drain-out tray stainless-Steel of suitable thickness for water cooler any make /size, with PVC waste pipe, pipe clamp, complete all as specified and directed
Supply and Charging of Freon gas R-134/R-12 for Refrigerator/Water cooler and Deep Freezer complete all as specified and directed
Supply and replacement of Evaporator coil assembly for refrigerator 165 to 310 Ltrs capacity complete all as specified and directed
Supply and replacement of Magnetic door gasket for refrigerator 165 to 310 Ltrs capacity complete all as specified and directed
Supply and replacement of freezer door for refrigerator 165 to 310 Ltrs capacity complete all as specified and directed
Supply and Charging of Freon gas R-22/R-410 for ACs complete all as specified and directed
Supply and replacement of flexible Core PVC insulated with stranded copper conductor 2.5 Sqmm 4 core 600/1100 V ISI Marked complete all as specified and directed
Supply and Replacement of PVC pipe connection, both end screwed 18” long 15mm dia with brass nuts and neoprene washers for water cooler/ desert coolers complete all as specified and directed
Material and Labour for Repairs to Voltage stabilizer of 1 KVA to 5 KVA capacity single phase 230 Volts of various make after disconnecting incoming and outgoing electric connection and carry out minor repair work such as repairing of internal worn out wires, repair to electronic circuit board, low/high cutoff circuit and replacement of unserviceable parts including testing by connecting on load and adjusting low/high cutoff and timing relay all as specified and directed.
Rewinding of Main transformer with super enamelled copper wire of suitable size including varnishing and heating complete suitable for 4/5 KVA all as specified and directed.
Rewinding of Main transformer with super enamelled copper wire of suitable size including varnishing and heating complete suitable for 01/2 KVA all as specified and directed
Supply and fixing in repair Suction/Discharge valve for 3 TR (2 x 1.5 TR) TR Split type AC all as specified and directed.
Supply and fixing in repair new lamp for Deep Freezers 500 Ltrs all as specified and directed.
Supply and fixing in repair new lamp cover for Deep Freezers 500 Ltrs all as specified and directed.
Supply and fixing in repair new lamp switch for Deep Freezers 500 Ltrs all as specified and directed.
Material and labour for core cutting on stone wall/concrete wall for inserting of copper tube and flexible copper cable for fixing of outdoor unit and making good to the disturbed surfaces also matching with the existing surfaces all as specified and directed.
Supply and fix PVC non-metallic flexible pipe of size 20mm dia alongwith fixing accessories such as saddles, pipe hook etc, for draining out the water from indoor unit complete all as specified and directed
M&L for sub-main wiring with two runs of 4 sqmm unsheathed PVC insulated, single core heavy duty ISI Marked FRLS cable 1100 volts grade with multistranded copper conductor drawn through and including PVC casing capping of suitable size and fixing accessories should be concealed/fixed to wall/roof/floor and including suitable PVC casing capping with 4 sqmm copper earth wire after taking out the existing sub-main wiring, making good to the disturbed surfaces also matching the existing surfaces all as specified and directed. Note: 2 runs of cable and one run earth wire and conduit/casing Capping will be measured as one length. Three runs of 4 Sq mm and PVC conduct/ Casing capping is measured as one Run or one Meter.
Supply and fixing in repair MCB Single pole, 230 volts, 20 Amps, 'B' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and directed
M&L for fix in replacement of PVC AC/ box with 20 Amp MCB DP, socket and plug top, PVC, 3 way complete all as specified and directed. Make Havells Product code DHDBCDP025201603/ Legrand / Anchor
S & F in replacement of Switch Socket Condult (SSC) 15 Amp including PVC gang box fixing screw ISI marked complete all as specified and directed. Make : Anchor/Legrand/HPL/Cona
Supply and fixing in replacement plug top 15 Amp white or ivory, ISI marked all as specified and directed. Make : Anchor/Legrand/HPL/Cona
Supply and fixing in repair MCB DP, 230 volts, 32 Amps, 'B' Curve, 10 KA, including disconnecting, taking down old/unserviceable, MCB Single pole and Neutral complete all as specified and directed
Dismantling voltage stabilizer including transformer copper wound, relays contact point, wiring with replacement of volt meter repair to transformer, replacement of relays, assembling the complete and testing for capacity 2 KVA and input rating 135-290 Volts complete all as specified and directed. Make: Volina/ V Guard/Vintech
All as per item No. 48 above but 3 KVA. Make: Volina/ V Guard/Vintech
All as per item No. 48 above but 4 KVA. Make: Volina/ V Guard/Vintech
All as per item no. 48 above but 5 KVA. Make: Volina/ V Guard/Vintech
Attending day to day complaints to identify major/minor faults related to Refrigerator/All types of AC/Deep Freezer/Water cooler and to rectify minor faults such as connectivity issues, leakage of gas, leakage of water, light not working, Ice maker not working, airflow issues, etc for proper functioning of the system all as directed by the Engr-in-Charge. Note : (a) All petty materials required to rectify the minor faults shall be arranged by the contractor. (b) Major faults shall be notified to the Engr-in-Charge. (c) All above provisions are deemed to be included in the quoted rate.
Supply and fix in repairs to PCB board with corded remote for 5/5.5 TR Split type AC complete all as specified and directed
Supply and fix in repair new Compressor of capacity 5.5 TR suitable for package type AC of capacity 5.5TR/11TR/16.5TR complete all as specified and directed
Supply and fix in repair new Compressor of capacity 8.2TR suitable for package type AC of capacity 5.5TR/11TR/16.5TR complete all as specified and directed
Supply and fix in repair of new Single phase preventer (SM-101) for 5/5.5TR Split type AC complete all as specified and directed
Supply and fix in repair of contactor for compressor contactor (LT, MN-16 for 5/5. 5TR Split type AC) complete all as specified and directed
Supply and fix in repair new filter drier for 5/5.5TR Split type AC complete all as specified and directed
Supply and fixing in replacement UPVC Pipe of size 80mm dia laid/ fix on wall with all accessories (Such elbow, tee, socket, union, clamp) complete all as specified and directed.
Supply and fixing in replacement UPVC Pipe of size 50mm dia laid/ fix on wall with all accessories (Such elbow, tee, socket, union, clamp) complete all as specified and directed.
Supply and fixing in replacement UPVC Pipe of size 32mm dia laid/ fix on wall with all accessories (Such elbow, tee, socket, union, clamp) complete all as specified and directed.
Supply and fixing in replacement UPVC Pipe of size 20mm dia laid/ fix on wall with all accessories (Such elbow, tee, socket, union, clamp) complete all as specified and directed.
Supply and fixing in replacement of PVC tap suitable for 15mm dia pipe complete all as specified and directed.
Supply and fix in repair metal clad socket outlet with single pole and neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amps, 'C' Curve, 10 KA rupturing capacity complete all as specified and directed
Taking out the contaminated water complete from the fountain and cleaning of the entire water storage area with wire brush by applying suitable detergent/cleaning material and washing the complete fountain with fresh water, cleaning of the nozzles, strainers, and suction side impellers including the refilling of water complete fountain all as directed
Cutting and taking out the existing rusted/Blocked GI/MS water tubing from the fountain and cleaning of the entire pipe line and inserting the new pipe by means of welding/brazing/plumbing and refixing the same with fittings like bends collars union wherever necessary all as specified and directed.
Supply and fixing in repairs of brass angle adjustable vertical jet nozzle size 3/8” BSP male threaded with nipple, nut & hex nipple orifice 5mm with neoprene rubber washer all as specified and directed.
Supply and fixing in repairs of brass dandelion jet nozzle, brass female threaded of size 1/4" BSP all as specified and directed.
Supply and fixing in repairs of aluminium foam jet nozzle size 1 " BSP brass male threaded with plastic/PVC inserts all as specified and directed.
Supply and fixing in repairs of CI fangled adjuster flange type with fasteners chrome plated and female threaded all as specified and directed.
Supply and fixing in repairs of brass angle adjuster size 1/2" BSP male threaded all as specified and directed.
Supply and fixing in repairs of brass angle adjustable verticals 1/2" BSP male threaded with nipple, nut and hex-nipple, orifice 8mm with neoprene rubber washer all as specified and directed.
Supply and fixing in repairs of brass angle adjustable vertical jet nozzle 1/4" BSP male threaded with nipple, nut and hex nipple, orifice 5mm with neoprene rubber washer all as specified and directed.
Supply and fix in repair of fountain LED light fittings with stand(Jumbo) 100% water proof resting filled multicolour auto colour change 12v x 30watt (+3%) of type 9.9 30y including making necessary fixing arrangements with nuts, bolts, and clamps, if necessary complete as specified and directed
Supply and fix in repairs of waterproof submersible LED IP68 3 Dynamic colour changing light fittings including making necessary fixing arrangements with nuts, bolts, and clamps, if necessary complete as specified and directed.
M&L for Cleaning and removing all scale and dirt, etc, from tanks of following capacity and from mouths of circulating pipes, etc. all as specified and directed
(a) not exceeding 250Ltrs
(b) Exc 250 & N Exc 500 Ltrs
(c) Exc 500 & N Exc 1000 Ltrs
(d) Exc 1000 & N Exc 2000 Ltrs
(e) Exc 2000 & N Exc 5000 Ltrs
Supply and fixing in replacement of PVC lid (Cover) suitable for PVC water tank of different capacity (250 to 5000 ltrs) all as specified and directed
S&F in replacement of ball valve for 25mm dia, high pressure of PTMT with epoxy quoted aluminium rod and high density plastic ball screwed for iron pipe all as specified and directed.
All as per item No.123 but 20mm dia
All as per item No.123 but 40mm dia
Repairs to Ball valve set any size by replacing the unserviceable PVC balls, rod, GI socket, long screw etc to arrest the overflowing of service tanks all as directed
S & F in repair of Rotational Moulded Polyethylene water storage tank 500ltrs (cylindrical vertical with closed Top) hoisted and fixed in position including dismantling and taking down old tanks complete all as specified and directed.
All as per item No.127 but capacity 1000Ltrs
All as per item No.127 but capacity 2000Ltrs
All as per item No.127 but capacity 5000Ltrs
All as per item No.127 but capacity 10000Ltrs
Taking up/down steel tubing of the following sizes and disconnections of fitting, joints from tubing where required complete all as specified and directed
Supply and laying of in repair GI tubing of following sizes in walls/ceilings or laid in floors of medium grade ISI marked including all types of fittings such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc and accessories complete all as specified and directed
JM Engineering (BID ID -3165103)
devan enterprises (BID ID -3165663)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .