Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LAdmitted-Finance | ₹5.0 L | L1 | Admitted-Finance |
| 2 | L2₹5.0 L+₹100 (0.02%)Admitted-Finance | ₹5.0 L+₹100 (0.02%) | L2 | Admitted-Finance |
| 3 | L3₹5.1 L+₹10,300 (2.07%)Admitted-Finance | ₹5.1 L+₹10,300 (2.07%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | TIWARI ENTERPRISES L3 | SHARMA ELECTRO INFRASTRUCTUERS PRIVATE LIMITED L1 | KABIR AND KABIR INDUSTRIES PRIVATE LIMITED L2 |
|---|---|---|---|---|---|---|
| 1.00 | Safe carriage of 8.5 mtr. long PCC pole from store center Mahoba/nearest 33/11 KV S/S to direct pit site in distance range 0 to 70 Km. including loading & unloading at both ends. | 50 | Nos | 2,200 ₹1,10,000 | 2,100 ₹1,05,000 Lowest | 3,000 ₹1,50,000 |
| 2.00 | Safe carriage of 11/13 mtr STP from store center Mahoba/nearest 33/11 KV S/S to direct pit site in distance range 0 to 70 Km. including loading & unloading at both ends. | 16 | Nos | 150 ₹2,400 | 50 ₹800 Lowest | 100 ₹1,600 |
| 3.00 | Safe carriage of 9 mtr STP from store center Mahoba/nearest 33/11 KV S/S to direct pit site in distance range 0 to 70 Km. including loading & unloading at both ends. | 7 | Nos | 150 ₹1,050 | 50 ₹350 Lowest | 100 ₹700 |
| 4.00 | Safe carriage of line material from store center Mahoba/nearest substation to pit site in distance range 0 to 70 Km. including loading & unloading at both ends. | 35 | Qtl | 90 ₹3,150 Lowest | 150 ₹5,250 | 100 ₹3,500 |
| 5.00Opening of binding & removal of following conductor with 33 KV/HT/LT line from broken PCC poles/rails/ STP and stacking at safer place. | ||||||
| 6.00 | 1- Dog/ Raccoon/ Rabbit conductor | 2 | Km | 200 ₹400 Lowest | 500 ₹1,000 | 200 ₹400 Lowest |
| 7.00 | 2- AAAC/ACSR weasel conductor/ GI wire. | 2.5 | Km | 200 ₹500 Lowest | 500 ₹1,250 | 200 ₹500 Lowest |
| 8.00 | Erection of 8.5 mtr. long PCC poles as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes | 38 | Nos | 4,000 ₹1,52,000 Lowest | 4,100 ₹1,55,800 | 4,000 ₹1,52,000 Lowest |
| 9.00 | Erection of 9 mtr. STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes | 7 | Nos | 100 ₹700 Lowest | 150 ₹1,050 | 100 ₹700 Lowest |
| 10.00 | Errection of 11/13 mtr.STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes | 12 | Nos | 100 ₹1,200 | 50 ₹600 Lowest | 100 ₹1,200 |
Tender Value
₹5 L
EMD Value
₹5,000
Closing Date
14 Apr 2026, 3:00 pmClosed
SE, EDC MAHOBA
BAJARIYA MAHOBA
Work of Maintenance of HT/LT lines in the area of EDSD Charkhari under EDD I Mahoba
2026_DVVNL_1129400_1
41/SE/EDCM/2025-26
Open Tender
Electrical Works
Item Rate
365 days
MAHOBA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
www.dvvnl.org
₹5,000
17 Jul 2026
9 Apr 2026
14 Apr 2026
9 Apr 2026
14 Apr 2026
9 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Safe carriage of 8.5 mtr. long PCC pole from store center Mahoba/nearest 33/11 KV S/S to direct pit site in distance range 0 to 70 Km. including loading & unloading at both ends. | 50 | Nos | - | - |
| 2 | Safe carriage of 11/13 mtr STP from store center Mahoba/nearest 33/11 KV S/S to direct pit site in distance range 0 to 70 Km. including loading & unloading at both ends. | 16 | Nos | - | - |
| 3 | Safe carriage of 9 mtr STP from store center Mahoba/nearest 33/11 KV S/S to direct pit site in distance range 0 to 70 Km. including loading & unloading at both ends. | 7 | Nos | - | - |
| 4 | Safe carriage of line material from store center Mahoba/nearest substation to pit site in distance range 0 to 70 Km. including loading & unloading at both ends. | 35 | Qtl | - | - |
| 5 | Opening of binding & removal of following conductor with 33 KV/HT/LT line from broken PCC poles/rails/ STP and stacking at safer place. | - | - | - | - |
| 6 | 1- Dog/ Raccoon/ Rabbit conductor | 2 | Km | - | - |
| 7 | 2- AAAC/ACSR weasel conductor/ GI wire. | 2.5 | Km | - | - |
| 8 | Erection of 8.5 mtr. long PCC poles as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes | 38 | Nos | - | - |
| 9 | Erection of 9 mtr. STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes | 7 | Nos | - | - |
| 10 | Errection of 11/13 mtr.STP as single support including fixing of all HT/LT accessories etc. complete.Pole should be grouted properly as per DVVNL/RESPO normes | 12 | Nos | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.26 MB
TN41.pdf
Tender Documents • 1.52 MB
BOQ_2118497.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .