| Sl No | Description | Qty | Unit | DT Enterprises L4 | NITISH TALWARA ENGINEERS L1 | Vinay Thakur L3 | sunil dutt L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Construction of RCC in M-25 design mix over head sector storage tank of 50000 Ltrs. Capacity with 10.00 mtrs. Staging height from ground level to bottom of dome slab comprising of inlet, scour & over flow pipes as per details given below from ground level to tank including bends of required degrees,valves of required size conforming to relevant codes RCC Sprial 1.0 wide stair case/ MS stair case including MS pipe railing as per IS specification, steel ladder 45 cms. wide of usual height as per site requirement , SFRC manhole cover ( medium duty) of 500 mm dia and weight of frame and cover should not be less than 110 kg. ventilator at top dome with minimum opening of 90x90cms. water level indicator including floats and measuring gauge, lightening conductor with earthing arrangement etc.The RCC over head reservoir shall include randering/plastering of the uneven expose surface, two coats of snowcem paint and any other component requuired for the completion of the job to the entire satisfaction of Engineer-in-Charge. The offers shall also include detail structural drawing/ design calcualtions to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site. The offer shall also inclcude the cost of providing and fixing of Gms / MS pipes, and valves/ fittings complete including duck foot bends, puddle collars, expansion joints etc. connecting with rising main & distribution main with required length from the edge of foundation and any other components required for the completion of job upto the entire satisfaction of the Engineer-in-Charge.
Dia of piping arrangement :-
Inlet pipe = 80mm dia G.I. pipe
Outlet pipe = 80mm dia G.I. pipe
Scour pipe = Not less than 100mm dia G.I. pipe. | 50,000 | Litrs. | 26.5 ₹13,25,000 | 21.5 ₹10,75,000 Lowest | 26 ₹13,00,000 | 24 ₹12,00,000 |
Tender Value
₹9.3 L
EMD Value
₹18,520
Closing Date
31 Jul 2026, 5:00 pmClosed
Executive Engineer
Jal Shakti Division Thanakalan
Construction of overhead storage tank of 50,000 ltrs with 10.00 mtrs staging height
2026_HPIPH_139794_1
UNA-UNA03-733
Open Tender
Civil Works
Lump-sum
30 days
Thanakalan
Please refer Tender documents.
6 documents required · 6 mandatory
₹350
₹18,520
14 Aug 2026
23 Jul 2026
1 Aug 2026
23 Jul 2026
31 Jul 2026
23 Jul 2026
23 Jul 2026 - 31 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of RCC in M-25 design mix over head sector storage tank of 50000 Ltrs. Capacity with 10.00 mtrs. Staging height from ground level to bottom of dome slab comprising of inlet, scour & over flow pipes as per details given below from ground level to tank including bends of required degrees,valves of required size conforming to relevant codes RCC Sprial 1.0 wide stair case/ MS stair case including MS pipe railing as per IS specification, steel ladder 45 cms. wide of usual height as per site requirement , SFRC manhole cover ( medium duty) of 500 mm dia and weight of frame and cover should not be less than 110 kg. ventilator at top dome with minimum opening of 90x90cms. water level indicator including floats and measuring gauge, lightening conductor with earthing arrangement etc.The RCC over head reservoir shall include randering/plastering of the uneven expose surface, two coats of snowcem paint and any other component requuired for the completion of the job to the entire satisfaction of Engineer-in-Charge. The offers shall also include detail structural drawing/ design calcualtions to be approved by the competent authority based on the raft foundation by taking seismic forces in the design calculation expension joints as required at site. The offer shall also inclcude the cost of providing and fixing of Gms / MS pipes, and valves/ fittings complete including duck foot bends, puddle collars, expansion joints etc. connecting with rising main & distribution main with required length from the edge of foundation and any other components required for the completion of job upto the entire satisfaction of the Engineer-in-Charge.
Dia of piping arrangement :-
Inlet pipe = 80mm dia G.I. pipe
Outlet pipe = 80mm dia G.I. pipe
Scour pipe = Not less than 100mm dia G.I. pipe. | 50,000 | Litrs. | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.15 MB
Form6.pdf
Tender Documents • 0.11 MB
Form8.pdf
Tender Documents • 0.67 MB
Termconditions.pdf
Tender Documents • 0.11 MB
BOQ_207221.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].