Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹47.8 LAccepted-AOC | L1 | Accepted-AOC Being the lowest bidder | |
| 2 | L2Rejected-AOC 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | L2 | Rejected-AOC Not being the lowest bidder | |
| 3 | L3Rejected-AOC | L3 | Rejected-AOC Not being the lowest bidder | |
| 4 | L4Rejected-AOC 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L4 | Rejected-AOC Not being the lowest bidder | |
| 5 | L5Rejected-AOC | L5 | Rejected-AOC Not being the lowest bidder |
Tender Value
₹60.0 L
EMD Value
₹1.2 L
Closing Date
6 Oct 2018, 6:00 pmClosed
Asstt. General Manager(E-E)-II
Airports Authority of India, CCSI Airport, Lucknow
Replacement of Electrical Panels, cables, fans etc. in AAI residential colony at CCSI Airport, Lucknow
2018_AAI_15107_1
AAI/LKO/AGM(E-E)-II/ eNIT-05/2018-19
Open Tender
Electrical Works
Item Rate
120 days
Lucknow Airport
Please refer Tender documents.
16 documents required · 16 mandatory
₹1,120
Revenue Collection (Lucknow Airport) A/C
₹1.2 L
20 Jan 2020
21 Sept 2018
10 Oct 2018
21 Sept 2018
6 Oct 2018
21 Sept 2018
21 Sept 2018 - 5 Oct 2018
Amount
Design, manufacture supply, installation testing and commissioning of outdoor type main feeder pillar, made of 2 mm thick CRCA steel sheet for frame work and covers, 3 mm thick for gland plates, totally enclosed, IP 54, free standing & floor mounted on civil foundation , gaskets for dust and vermin proof, indoor, compartmentalised, including cleaning & finishing complete with 7 tank process powder coated, painting suitable for operation of 3 phase and neutral, 415 V, 50 Hz AC system with Al.busbars of 1000A ratings , fabrication shall be done in transportable sections, conforming to IS 8623:93 & CPWD specifications, entire panel shall have a common GI earth bar of size 25 mm X 5 mm at the rear with 2 nos. earth stud, control wiring with 2.5 Sq.mm PVC insulated copper conductor, cable alley, cable gland plates in two half,cable termination through terminal blocks, interconnections including supply & installation of following items and as per technical specification: INCOMER:- 800 A, 415V Four pole MCCB ,50KA, ,Microprocessor Based, Short Circuit Protection ,Earth Fault Protection, adjustable overload, other required accessories ,etc.- 1no. Outgoings: Suitable Busbars for outgoing cable for 1000 amp. Digital AmpVolt/Frequency meter as required for incomer - 1 nos. Set of LED type Indicating lamps (for each phase "R","Y","B")-1set of three each, with 2A SPMCBs as required, with all interconnections, labels,suitable lighting & cooling arrangement as per IP66 etc complete as required
Design, manufacture supply, installation testing and commissioning of main LT PANEL, cubicle & modular type, made of 2 mm thick CRCA steel sheet for frame work and covers, 3 mm thick for gland plates, totally enclosed, IP 42, free standing & mounted on civil foundation , gaskets for dust and vermin proof, indoor, compartmentalised, including cleaning & finishing complete with 7 tank process powder coated, painting suitable for operation of 3 phase and neutral, 415 V, 50 Hz AC system with Al.busbars of 300 A ratings, fabrication shall be done in transportable sections, conforming to IS 8623:93 & CPWD specifications , entire panel shall have a common GI earth bar of size 25 mm X 5 mm at the rear with 2 nos. earth stud, control wiring with 2.5 Sq.mm PVC insulated copper conductor, cable alley, cable gland plates in two half,cable termination through terminal blocks, interconnections including supply & installation of following items and as per technical specification including dismantling and shifting of existing old LT Pane/Feeder Pillarl in AAI Store if required: INCOMER:- 2 Nos. 250 A, 415V Four pole MCCB ,36KA, Microprocessor Based, Short Circuit Protection ,Earth Fault Protection, adjustable overload, other required accessories etc. 1 No. onload Four pole changeover switch of rating 300 A, 415V 50Hz. Outgoings: 125 Amp, Four pole MCCB ,36 KA, Fixed Thermal Magnetic with extended rotary handle & spreader along with auxiliary Contact - 02 nos. 100 Amp, Four pole MCCB ,36 KA, Fixed Thermal Magnetic with extended rotary handle & spreader along with auxiliary Contact - 06 nos. Digital AmpVolt/Frequency meter as required for incomesr -2 nos. Set of LED type Indicating lamps (for each phase "R","Y","B")=10 Sets of three each with 2A SPMCBs as required, with all interconnections, labels, complete as required.
Design, manufacture supply, installation testing and commissioning of outdoor type LT Feeder Pillar, cubicle & modular type, made of 2 mm thick CRCA steel sheet for frame work and covers, 3 mm thick for gland plates, totally enclosed, IP 54, free standing & mounted on civil foundation , gaskets for dust and vermin proof, indoor, compartmentalised, including cleaning & finishing complete with 7 tank process powder coated, painting suitable for operation of 3 phase and neutral, 415 V, 50 Hz AC system with Al.busbars of 200A ratings, fabrication shall be done in transportable sections, conforming to IS 8623:93 & CPWD specifications, entire panel shall have a common GI earth bar of size 25 mm X 5 mm at the rear with 2 nos. earth stud, control wiring with 2.5 Sq.mm PVC insulated copper conductor, cable alley, cable gland plates in two half,cable termination through terminal blocks, interconnections including supply & installation of following items and as per technical specification including dismantling and shifting of existing old LT Panel/Feeder Pillar AAI Store if required: INCOMER:- 1 No. 125 A, 415V Four pole MCCB ,36KA, , Fixed Thermal Magnetic, other required accessories ,etc Outgoings: 100 Amp, Four pole MCCB ,36 KA, Fixed Thermal Magnetic with extended rotary handle & spreader along with auxiliary Contact - 01 nos. 63 Amp, Four pole MCCB ,36 KA, Fixed Thermal Magnetic with extended rotary handle & spreader along with auxiliary Contact - 03 nos. Digital AmpVolt/Frequency meter as required for incomer - 1 nos. Set of LED type Indicating lamps (for each phase "R","Y","B")-5 sets of three each, with 2A SPMCBs as required, with all interconnections, labels, complete as required.
Design, manufacture supply, installation testing and commissioning of outdoor type LT Feeder Pillar, made of modular polycarbonate thermoplastic material double door totally enclosed, IP 65, mounted on Iron angle frame on civil foundation , of suitable dimension , outdoor, compartmentalised, cable entry from bottom , spreader link (set of 8), terminal block,barrier plate,end clamps, marking label, mounting plate, Aluminium/Copper busbar of 300 amp rating,frame & canopy wiring accessories ,earth strip, sleeves, ferrules,dinrail,neutral link ,etc.& following items as per technical specification including dismantling and shifting of existing old LT Panel/Feeder Pillar AAI Store if required: INCOMER:- 200 Amp, Four pole MCCB,25 KA, Microprocessor based with short circuit protection, earth fault protection, adjustable overload with extended rotary handle & spreader along with auxiliary Contact -1 No. Outgoings: 125 A, 415V Four pole MCCB ,10 KA, , Fixed Thermal Magnetic, other required accessories ,etc- 3 Nos Digital AmpVolt/Frequency meter as required for incomer - 1 nos. Set of LED type Indicating lamps (for each phase "R","Y","B")=4 sets of three each with 2A SPMCBs as required, with all interconnections, labels, etc. (Make : Hensel or approved equivalent)
Design, manufacture supply, installation testing and commissioning of outdoor type LT Feeder Pillar, made of modular polycarbonate thermoplastic material double door totally enclosed, IP 65, mounted on Iron angle frame on civil foundation , of suitable dimension , outdoor, compartmentalised, cable entry from bottom , spreader link (set of 8), terminal block,barrier plate,end clamps, marking label, mounting plate, Aluminium/Copper busbar of 200 amp rating , frame & canopy wiring accessories ,earth strip, sleeves, ferrules,dinrail,neutral link ,etc.& following items as per technical specification including dismantling and shifting of existing old LT Panel/Feeder Pillar AAI Store if required: INCOMER:- 160 Amp, Four pole MCCB,25 KA, Microprocessor based with short circuit protection, earth fault protection, adjustable overload with extended rotary handle & spreader along with auxiliary Contact -1 No. Outgoings: 63 A, 415V Four pole MCB ,10 KA, Fixed Thermal Magnetic, other required accessories ,etc- 3 Nos 32 A Double pole MCB- 07 nos. Digital AmpVolt/Frequency meter as required for incomer - 1 nos. Set of LED type Indicating lamps (for each phase "R","Y","B")=1 set of three each with 2A SPMCBs as required, with all interconnections, labels,etc.(Make : Hensel or approved equivalent)
Design, manufacture supply, installation testing and commissioning of outdoor type LT Feeder Pillar, made of modular polycarbonate thermoplastic material double door totally enclosed, IP 65, mounted on Iron angle frame on civil foundation , of suitable dimension , outdoor, compartmentalised, cable entry from bottom , spreader link (set of 8), terminal block,barrier plate,end clamps, marking label, mounting plate, Aluminium/Copper busbar of 400 amp rating,frame & canopy wiring accessories ,earth strip, sleeves, ferrules,dinrail,neutral link ,etc.& following items as per technical specification including dismantling and shifting of existing old LT Panel/Feeder Pillar AAI Store if required: INCOMER:- 320-400 Amp, Four pole MCCB ,36 KA, Microprocessor based with short circuit protection, earth fault protection, adjustable overload, with extended rotary handle & spreader along with auxiliary Contact-1 No. Outgoings: Aluminium/Copper Bus Bar of rating 400 amp. Digital AmpVolt/Frequency meter as required for incomer - 1 nos. Set of LED type Indicating lamps (for each phase "R","Y","B")=1 set of three each with 2A SPMCBs as required, with all interconnections, labels. (Make : Hensel or approved equivalent)
Design, manufacture supply, installation testing and commissioning of outdoor type LT Feeder Pillar, made of modular polycarbonate thermoplastic material double door totally enclosed, IP 42, mounted on wall , of suitable dimension , compartmentalised, cable entry from bottom , spreader link (set of 8), terminal block,barrier plate,end clamps, marking label, mounting plate, Aluminium/Copper busbar of 150 amp rating, wiring accessories ,earth strip, sleeves, ferrules,dinrail,neutral link ,etc.& following items as per technical specification including dismantling and shifting of existing old LT Panel/Feeder Pillar AAI Store if required: INCOMER:- 100 Amp, Four pole MCCB ,25 KA, Microprocessor based with short circuit protection, earth fault protection, adjustable overload, with extended rotary handle & spreader along with auxiliary Contact-1 No. Outgoings: 32 amp DP MCB- 6 Nos. single phase energy meter - 4 nos. Digital AmpVolt/Frequency meter as required for incomer - 1 nos. Set of LED type Indicating lamps (for each phase "R","Y","B")=1 set of three each with 2A SPMCBs as required, with all interconnections, labels, etc complete as required.(Make : Hensel or approved equivalent)
Supply of XLPE insulated, PVC innersheathed, armoured aluminium cable,1100 V as per IS 7098 (Part 1) 1988 with upto date amendments of following sizes:
3x 1/2 core , 400 sq.mm.
3x 1/2 core ,240 sq.mm.
3x 1/2 core ,150 sq.mm.
3x 1/2 core , 50 sq.mm.
3x 1/2 core , 25 sq.mm.
4 core, 16 sqmm.
2 core, 6 sq.mm.
Supply of 110 mm dia PLB PE 80 PN 06 HDPE pipes as per standard technical specification as required .
Supply of 90 mm dia PLB PE 80 PN 06 HDPE pipes as per standard technical specification as required .
Laying of HDPE pipe 110 mm dia with HDD trenchless method direct in ground at minimum depth of 3 meter in all type soil including 4mm PP rope, coupling, splicing of pipe, etc with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc complete in all respect as per specification.
Laying of HDPE pipe 90 mm dia with HDD trenchless method direct in ground at minimum depth of 3 meter meter in all type soil including 4mm PP rope, coupling, splicing of pipe, etc with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc complete in all respect as per specification.
Blowing /Drawing of one number upto 1100 V XLPE armoured aluminium cable of size of 150 sqmm in existing HDPE pipe in ground etc. as required.
Blowing /Drawing of one number upto 1100 V XLPE armoured aluminium cable of size of 240 sqmm. in existing HDPE pipe in ground etc. as required.
Constructing brick masonry chamber of size 1200mmx1200mmx1000mm of size in cement mortar 1:4 (1 cement :4 coarse sand ) inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement: 3 Coarse sand) finished with floating coat of neat cement foundation concrete 1:3:6( 1 cement: 3 coarse sand:6 graded stone aggregate 40 mm nominal size) all complete as per standard design with cover of 75 mm thick ness made by RCC in cement mortar 1:2:4( 1 cement: 2 coarse sand:4 graded stone aggregate 40 mm nominal size) in two piece with 12 mm rod handle in order to easy handling.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm· dia (OD-63 mm & ID-51 mm nominal)
90 mm dia (OD-90 mm & ID-76 mm nominal)
120 mm dia (OD-120 mm & ID-103 mm nominal)
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size in the existing RCC/ HUME/ METAL/DWC pipe as required.
upto 35 sq.mm
above 35 & upto 95 sq.mm.
Supply of single phase 50 W ,1200 mm sweep ,330 rpm ,double ball bearing , with canopy , downrod, 5 star energy saving ceiling fan, complete,etc. as required. (Make: USHA ,havells ,bajaj or equivalent approved make.)
Installation, Testing & Commissioning of ceiling fan including connection etc. as required.
Supply of single phase 300 mm sweep, 900 rpm speed heavy duty exhaust fan with proper electrical connection, complete as required,etc.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/termination with GI thimble etc. as required.
Supplying and laying 25 mm X 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Industrial Traders
Naagar Infrastructure Pvt Ltd
Awasthi Electric Works
SAURABH ENTERPRISES
BR Power Control and Automation Services
Robust Electric
PANUN ENTRACON PVT LTD
UNNATI ENGINEERS
Gayatri Electric Projects (I) Pvt. Ltd.
ANU ENGINEERING CORPORATION
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .