Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹32.0 LAdmitted-Finance A 6 MANDAWALI UNCHEPAR DELHI 110092 | SHAHDARA | DELHI | 110092 | L1 | Admitted-Finance | ||
| 2 | L2₹34.5 L+₹2.5 L (7.88%)Admitted-Finance 272 VIKAS KUNJ VIKAS PURI NEW DELHI 110018 | WEST | DELHI | 110018 | L2 | Admitted-Finance | ||
| 3 | L3₹37.5 L+₹5.5 L (17.2%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | L4₹39.3 L+₹7.3 L (22.7%)Admitted-Finance NOT SPECIFIED | L4 | Admitted-Finance | ||
| 5 | L5₹40.1 L+₹8.1 L (25.4%)Admitted-Finance | L5 | Admitted-Finance |
Tender Value
₹55.7 L
EMD Value
₹1.1 L
Closing Date
5 Mar 2026, 3:00 pmClosed
EXECUTIVE ENGINEER (E) PWD EMD SOUTH WEST
O/o Executive Engineer (E) PWD EMD South West Brar Square near Delhi Cantt Metro Station New Delhi
RMO EI fans pumps compound light DG set
2026_PWD_287729_1
109/EE (E)/PWD EMD South West/2025-26
Open Tender
Electrical Works
Percentage
365 days
works
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
₹1.1 L
10 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
5 Mar 2026
25 Feb 2026
Sub Head I:- EI, FANS & AC
Routine Maintenance all electrical installation internal and external, compound light, electrical panels and switch gears, pumps, provision of fans and fittings, lamps of all sizes etc repairing of panel board, street lights etc as reqd.
Wireman- 1 No. (9 AM to 5 PM)
Khallasi - 1 No. (9 AM to 5 PM)
Following material /electrical accessories shall be supply by agency suitable for existing different type switch box / fitting and existing man power shall be used for replacement on day to day maitenance works etc as required. (Labour already included in Item No. 1 o Sub Head - I : EI & FANS)
S.P. 5/6 amps, one way modular switch, ISI marked
S.P. 15/16 amps, one way modular switch, ISI marked
3 pin 5/6 amps modular socket outlet, ISI marked
6 pin 15/16 amps modular socket outlet, ISI marked
Modular bell push, ISI marked
Modular base & cover plate for 1/2 module
Modular base & cover plate for 3 module
Modular base & cover plate for 6 module
S.P. 5/6 amps, one way switch, piano type ISI marked
S.P. 15/16 amps, one way switch, piano type ISI marked
3 pin 5/6 amps socket outlet, piano type ISI marked
6 pin 15/16 & 5/6 amps socket outlet, piano type ISI marked
Bell push, piano type
Telephone Socket outlet piano type
T.V. Socket outlet piano type
Ceiling rose, 3 pin, 5 amps ISI marked
Call bell/ buzzer, single phase
3 mm thick phenolic laminated sheet i/c cutting of suitable size & fixing on existing switch board with fixing of all existing switch/socket/ Fan regulator.
6 to 32 Amp c Curve SP MCB, "C" curve, 10 kA breaking capacity
6 amps. to 32 amps. ratings , DP MCB, “C” curve, 10 KA breaking capacity
6 amps. to 32 amps. ratings , TP MCB, “C” curve, 10 KA breaking capacity
6 amps. to 32 amps. ratings , TPN MCB, “C” curve, 10 KA breaking capacity
63 amps.4 Pole MCB
40 amps DP MCB
63 amps DP MCB
63 amp TP MCB
3 pole MCCB, 100A, 16kA Ics=100% Icu and Operational Voltage 690V
3 pole MCCB, 200A, 25kA Ics=100% Icu and Operational Voltage 690V
3 pole MCCB, 125A, 16kA Ics=100% Icu and Operational Voltage 690V
4 pole MCCB,100A,30kA Ics=100% Icu and Operational Voltage 690V
1.5 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable
4.0 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable
6.0 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable
10 sq. mm ISI marked, FR PVC insulated, single core copper conductor cable
2.50 mF capacitor
Heavy Duty Steel Ceiling Fan Hook Attachment Clamp with Rubber, Nut Bolts & Locking Pins.
Stepped type Modular Fan regulator (2 module)
Medium Step Fan Regulator piano type
4 way (4+12), TPN, vertical type, MCB DB, double door
Ceiling fan with Brush Less Direct Current (BLDC) Motor, etc. complete as req 1200 mm sweep Ceiling fans 1200 mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
300 mm sweep heavy duty exhaust fans
250 mm sweep PVC Air Ventilation fans
Electronic driver (5W to 12W) LED fixture
Electronic driver (15W to 22W) LED fixture
Electronic driver (36W/40W to 70W/75W) LED fixture
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 36 watt
LED Down lighter (SMD Type) (System lumen efficacy ≥ 105 < 120 lm/Watt ) of following body materials. Powder coated die cast /Extruded aluminium Body including trim with Aluminium Reflector a) 12 -15 watt
Supply of LED Bulk Head fitting not more than 10 W, System efficacy not less than 100 lumens / watt, System output not less than 1000 lumens / watt, CRI>80 and CCT= 5500-6500K and IP-66 rated with aluminium die cast housing & frostrated glass diffuser complete as required.
600 mm long nominal size LED batten mirror light fitting made out with Aluminium die cast housing and Poly carbonate diffuser with all accessories having rating not more than 10 W, System Efficacy not less than 100 lm/W, lumens output not less than 1000, CRI >80 complete etc. as required.
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) of following body materials. Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) a) 36 watt
LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy 105 <120 lm/Watt) of following body materials.
LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥105 <120 lm/Watt) of following body materials.
Supplying and Laying of following size XLPE insulated PVC outer sheathed armoured cable with aluminium Conductor suitable for rated voltage of 1100 Volts ISI marked conforming to IS : 7098-1988 with upto date amendments i/c laying in followinf way, connection complete etc. as reqd.
3 X 10 Sq.mm ( laying in pipe)
3 X 10 Sq. mm ( laying in open duct/ open air)
4 X 16 Sq. mm ( laying in pipe)
4 X 16 Sq. mm ( laying in open duct/ open air)
Providing and fixing/laying 6 SWG dia G.I. wire on surface/recess/ in pipe for loop earthing along with existing cable as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (40 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
63 mm dia (OD-63 mm & ID-51 mm nominal)
SITC of weather proof pole box made out of hot moulded SMC sheet with clamp /fastner neutral link strip, gland thimble and 1 No. 6 Amps SPMCB Complete with inter connection with copper wire, earthing (Box Size - 300mm x 200 mm x 105 mm)
Rewinding of 1200mm ceiling fan complete with super enemelled copper winding wire i/c varnishing backing testing commissioning and without returning of scrop copper wire etc. as reqd.
Rewinding of 300mm Exhaust fan complete with super enemelled copper winding wire i/c varnishing backing testing commissioning and with credit of scrap copper wire etc. as reqd.
Rewinding repair and servicing of following monoblock/Submersible pump set suitable for run 3 phase, 440 volt, 50 Hz AC supply i/c carriage (to and fro) testing, commissioning with credit of scrap copper wire etc. as required.
3/5 HP monoblock pump set
7.5/10 HP monoblock pump set
7.5 HP submersible pump set
Supplying, installation, testing & commissioning of openwell/ mono-submersible pump set of 3.0 HP/ 2.20 kW rating operating on 3-¢ 50 Hz A.C. supply having discharge of (450 to150) LPM at a head of (15 to 27) meter, complete with 3 x 4 sqmm. PVC insulated PVC sheathed Flat submersible copper conductor cable of standard length and suitable for DOL/star delta starter, Suction - 50, Delivery - 40 i/c lowering the same in existing sump/tank i/c providing GI nuts, bolts, washers, rubber gasket and connecting the pipe line and electrical cable with water proof joint, connection testing etc. as required.
Withdrawing of all capacity submersible pump set with motor with GI pipes from the existing borewell with the help of chain pully block, tripod and supplying clamp i/c dismentalling of GI pipe lengths by opening the nut & bolts, stacking the same etc as reqd
Lowering of all capacity submersible pump set with motor with GI pipes from the existing borewell with the help of chain pully block, tripod and supplying clamp i/c dismentalling of GI pipe lengths by opening the nut & bolts, stacking the same etc as reqd
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
Group C
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.
Group C
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 amps modular socket outlets and 2 nos 5/6 amps modular switches, connection etc. as required.
Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess i/c providing and fixing 25 amp modular socket outlet and 25 Amps modular SP MCB, “C” curve including connection, ainting etc. as required.
Complete Servicing of existing installed WTAC /STAC of 1.5 TR & 2.0 TR capacity AC i/c indoor & outdoor units, checking for unit, inspection, greasing, oiling etc i/c chemical cleaning of the condensing coil with high pressure pump changing the air filter, checking & tightening all electic connection, testing the machine etc as reqd.
Supplying & charging of M-22/R22/R-32/R-410A gas in the exising WTAC / STAC of following capacity unit i/c pressure testing, flushing the system & gas charging complete etc as reqd.
Repair of damaged PCB of indoor and outdoor unit i/c tightening the loose connection, testing the machine etc as reqd. .
Supplying and fixing of 1.5 / 2 TR capacity WTAC/ Split AC cooling coils i/c pressure testing after removing the leakage with brazing, flashing the system , vaccuming the system, checking & repairing nterconnection complete in all respect as required at site. i.c dismantled of old material etc. as reqd.
Supply & Replacement of 1.5 / 2 TR WTAC / STAC burnt out / defective copper condenser coil with new one of the same size and design suitable for 1.5 / 2 TR Split type AC Out Door unit i/c breezing the all copper pipe with all distribution joint's and make sure the connections with capillary tube linking dryer duly proper etc. Nightrogen pressure testing, leak detections, vaccumizing the unit, complete as reqd. i/.c dismantled of old material etc. as reqd
Dismantling & Re-installation of exisiting installed TAC / WTAC of 1.5 TR & 2.0 TR capacity with outdoor unit from its location to another location, unloading for reinstallation checking for unit, inspection and reconnection of drainage pipe, reconnection and tightening the loose connection, testing the machine etc as reqd.
Supplying & fixing of following capacity compressor in the existing WTAC / Split AC making copper pipe connection, brazong pressure testing and supplying and charging M-22/R-32/R-410A refrigerant gas charging i/c cutting the copper piping dismantling of the old compressor complete as reqd.
Compressor - 1.5 TR
Compressor - 2 TR
Providing and fixing WTAC /STAC fan motor capcity 1/4 to 1/8 HP i/c dismantling the burnt out motor from the existing unit & fixing of new motor making onnection, testing complete etc as reqd.
Supplying & fixing of copper refrigerant pipe of size 1/4", 1/2" or 5/8" (as per suitable) with insulation and copper wire 3core 80-20 (2.5 sqmm) i/c all connection in the existing AC units i/c dismantled as per reqd at site.
Supply and installation of control cum transmission wiring of 3 core x 2.5 sqmm copper Unarmoured in suitable fittings between indoor and outdoor units on surface / conduit / pipe / cable tray / open duct etc. complete as required
Supplying, installation, testing & commissioning of submersible pump set of 7.50 HP/ 5.50 kW rating operating on 3-¢ 50 Hz A.C. supply having discharge of (660 to 258) LPM at a head of (24 to 50) meter, complete with PVC insulated PVC sheathed Flat submersible copper conductor cable of standard length and suitable for DOL/star delta starter, Delivery - 50 i/c lowering the same in existing bore well i/c providing GI nuts, bolts, washers, rubber gasket and connecting the pipe line and electrical cable with water proof joint, connection testing etc. as required.
Supplying and fixing of 3x4 sqmm flat submersible cable of copper conductor cable alongwith GI pipe line etc. as required.
Sub Head II:- For DG Sets
Operation and routine maintenance of 200 KVA DG set installed at Bhagini Nivedita collage, Kair all days of the month i/c Sunday and Holidaysas per terms & condition.
(a) Electrician/ DG set operator - 1 No. (9 AM to 5 PM) in one Shift
Annual routine maintenance of following capacity DG set with AMF panel complete checking by Engineer for smooth running with minor adjustment, Diagnosis of various faults and rectification by providing regular visit of Engineer and mechanics and attending of complaint 24 hours basis.(Excluding major repair of engine and alternator)
DG Set 200 KVA (Model No.6CTAA Cummins)
Servcing and 'B' Check of following capacity DG set complete with changing of engine oil & filters etc as reqd.i/c credit of old dismantled material etc as reqd. DG Set 200 KVA (Model No.6CTAA Cummins)
B CHECK KIT 6CTA (Part No.3238543)
B CHECK KIT 6CTA (Part No.3238667)
INHIBITOR CORROSION (5 LITERS)(Part No.3816986)
FOIL SEALED TEST STRIP (Part No.3403800)
INDICATOR RESTRICTION (Part No.3815511)
GASKET ROCKER LEVER COVER (Part No.3905449)
INHIBITOR CORROSION (10 LITERS) (Part No. 4926654)
CONTROL GENSET (Part No.0300-6014 )
BATTERY PULSE LITE 12V 65 AH (Part No.AX1012843)
RADIWASH 1 LITER (Part No.AX1013358 )
FUNNEL FUEL FILTER CONDUCTIVE M (Part No.AX1015646 )
VCL PREMIUM BLUE 7800 PLUS 1/20 LTRS (Part No. 505441 )
Charges towards cleaning & descaling of radiator for 250 KVA DG Sets
Charges towards alternator health checkup and preventive maintenance including minor repair & adjustment at site.
Sub Head III:- Fire Fighting
Operation and routine maintenance of fire fighting system installed at Bhagini Nivedita collage, Kair, all days of the month i/c Sunday and Holidays i/c attending day to day complaint, rectification of fault, maintain records all of parameters etc. as reqd as per terms & conditions. a). Fire man/ Operator- 3 Nos. (Round the clock- one in each shift)
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
25 mm dia
100 mm dia
Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :
Single headed Stainless steel
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
100 mm dia
Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :
100 mm dia
Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required.
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required :
100 mm dia
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :
Stainless Steel (Grade 304)
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :
Stainless Steel (Grade 304)
Providing and fixing glazing hose reel box,Hydrent box etc. with EPDM rubber / neoprene gasket etc. complete as per the directions of engineer-in-charge .
With float glass panes of 4.0 mm thickness
Painting (two or more coats) on fire fighting pipes and fittings with synthetic enamel paint of approved brand and manufacture and required colour over a priming coat of approved steel primer on new work.
100 mm diameter pipes
SH-IV:- Credit of Dismantled material
Less Credit cost for following old dismantled materials
WTAC/STAC fan motor
AC Copper refrigerant pipe associated
7 HP Submersible p/set
3 HP Open well mono block
copper submersible cable
2.5 mfd condensers
5/6A/ 15/16A Switch/ Socket/ bell push/ 2 way switch
c' curve SP MCB 6-32A
6-32A DP MCB 'c' curve
6-32A TP MCB 'c' curve
6-32A TPN MCB 'c' curve
Call bell/ buzzer, single phase
MCCB 100 A
MCCB 125 A
MCCB 200 A
1.5/4.0 sqmm. FRLS Copper conductor cable
6.0/10.0sqmm. FRLS Copper conductor cable
Ceiling fan
LED Panel light 2x2 ft.
Exhaust Fan
PVC Air ventilation fan
Street light fittings
LED Down lighter
LED Batten light
LED Bulk Head fitting
LED batten mirror light fitting
LED flood light
Modular base & cover plate for 1,2,3,4,5,6,7,8 & 12 module
Stepped type Modular Fan regulator (2 module)
Medium Step Fan Regulator piano type
36/40/70/75 W Electronic Choke/ electronic Driver
5/12/15/22 W Electronic Ballast/ electronic Driver
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.41 MB
BOQ_381380.xls
BOQ • 0.49 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .