CWE (A) Jaisalmer
CWE (A) Jaisalmer
REPAIR AND MAINT OF HT UG CABLE/OH LINE, TRANSFORMER, VOLTAGE STABLIZER AND ALLIED WORKS AT ASCON NODES AND DABLA UNDER MIL STN JAISALMER UNDER GE(A) JAISALMER
2021_MES_473082_2
83971
Open Tender
Electrical and Maintenance Works
Works
180 days
Jaisalmer
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (A) Jaisalmer
₹30,000
Yes
1 Feb 2022
9 Oct 2021
1 Nov 2021
9 Oct 2021
30 Oct 2021
16 Oct 2021
Amount
Note : The location for execution of work will be Escon Nodes at Gemnewala, Sanu, Danwar, Sangarh, Rannautar, Mohangarh , Ramgarh and Dabla area, Rates to be quotated by the constractor considering the distance locations.
Taking down and dismounting defective transformer 11/0.433 KV of capacity upto 63 KVA from foundation/ pole by using crane and transporting to workshop or factory (authorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete ,spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-in-Charge.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 75 KVA to 160 KVA from foundation/ pole by using crane and transporting to workshop or factory (authorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor and LV side LT cable , dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES No with white paint of suitable size letter and transporting back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-In-Charge.
Taking down and dismounting defective transformer 11/0.433 KV of capacity 200 KVA to 250 KVA from foundation/ pole by using crane and transporting to workshop or factory (authorised for such repair) for repair after disconnecting HV side HT cable or HT aluminium conductor, LV side, LT cable dismantling the same for repair & renewal of unserviceable parts and reassembling complete, spray painting with two coats of synthetic enamelled grey paint after preparation of old surface writing MES NO with white paint of suitable size letter and transporting back from workshop to site, installation on plate form/pole, testing & commissioning to entire satisfaction of Engineer-In-Charge. NOTE FOR SER ITEM NO.2 TO 4 :- Spare parts ie, transformer oil, copper winding wire for rewinding will be measured and paid separately under supply only.
Supply and Fixing in repair Synthetic rubberised gaskets for top cover of transformer for the following :-
11/0.433 KV 63 KVA to 160 KVA capacity complete.
11/0.433 KV 200 KVA to 250 KVA capacity complete.
Supply and Fixing in repair Synthetic rubberised gaskets for HT bushing of transformer for the following :-
11/0.433 KV 63 KVA to 160 KVA capacity complete.
11/0.433 KV 200 KVA to 250 KVA capacity complete.
Supply and Fixing in repair Synthetic rubberised gaskets for LT bushing of transformer for the following :-
11/0.433 KV 63 KVA to 160 KVA capacity complete.
11/0.433 KV 200 KVA to 250 KVA capacity complete.
M&L for taking out unserviceable core and limb and HV/LV winding of transformer and taking out burnt copper winding wire cleaning carefully an rewinding the same with new superior quality 99.99% pure copper enamelled wire as per existing gauge including insulating material for transformer 63 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
Supply and Fixing in repair of transformer oil of dielectric strength 50 KV minimum for voltage stablizer, transformer, CTs 33 KV and PTs 33 KV outdoor type factory sealed with test certificate complete all as specified & directed by Engineer-in - Charge.
Dehydration of transformer oil (mounted on poles/platform etc) with the help of filtering and drying plant by mechanical machines of suitable capacity to achieve dielectric strength of 50 KV complete all as specified and directed by Engineer-in-Charge.(Note : For any capacity of Transformer)
M&L in repair of unserviceable HT brass stem of transformer 63 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 63 KVA to 160 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable LT brass Stem with nuts, washers of transformer 11/0.433 KV of capacity 160 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable breather assembly with new silica gel of transformer 11/0.433 KV of capacity 63 KVA to 160 KVA complete all as specified & directed by Engineer-in - Charge.
M&L in repair of unserviceable breather assembly with new silica gel of transformer 11/0.433 KV of capacity 200 KVA to 250 KVA complete all as specified & directed by Engineer-in - Charge.
Supply & renewal of porcelain transformer bushing 11 KV suitable for transformer upto 250 KVA complete all as specified & directed by Engineer-in - Charge.
Supply & renewal load tap changer suitable for 11 KV transformer of capacity upto 250 KVA complete all as specified & directed by Engineer-in - Charge.
S & F in repair dimmer suitable for voltage stablizer 75 KVA (3x25) complete all as specified and directed by Engineer-in-charge.
S & F in repair servo motor 3 Kg / Sqcm suitable for voltage stablizer 75 KVA (3x25) complete all as specified and directed by Engineer-in-charge.
S & F in repair PCB suitable for voltage stablizer 75 KVA (3x25) complete all as specified and directed by Engineer-in-charge.
Supply, Jointing and testing indoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Supply, Jointing and testing outdoor type cable termination heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
Supply jointing and testing straight through heat shrinkable joint kit 11 KV Unearthed grade suitable for size 95 Sqmm 3 core 11 KV under ground XLPE cable complete all as directed by Engineer-in-Charge.
S&F in repair, MCCB four pole, 63 Amp 16 KA fixed thermal magnetic release with threshold and Adjustable Over Load setting: 0.7-1.0x in & wide range of snap fit internal and external accessories. Ics = 75% icu type of DNO-100D complete installation & testing complete all as specified & directed by Engr-in-charge.
S&F in repair, MCCB four pole, 100 Amp 27 KA fixed thermal magnetic release with threshold and Adjustable Over Load setting: 0.7-1.0x in & wide range of snap fit internal and external accessories. Ics = 100% icu type of DNO-100D complete installation & testing complete all as specified & directed by Engr-in-charge.
S&F in repair, MCCB four pole, 160 Amp 35 KA with micro processor release adjustable thermal magnetic release with threshold and Adjustable Over Load setting: 0.4-1.0x in & wide range of snap fit internal and external accessories. Ics = 100% icu type of DNO-100D complete installation & testing complete all as specified & directed by Engr-in-charge.
S&F GI pipe light grade of dia 80 mm laying in road and along with poles for cable protection complete including taking down old pipe all as directed by Engineer-in-charge.
Supply, installation, testing and commissioning of lightening arrestors (station type) out door type discharge current 10 KA assembly suitable for 12 KV including all clamps, nuts, bolts and washers and connection to earth with 32x6mm GI strip and including taking down existing lightening arrestors complete all as specified & directed by Engineer-in-charge.
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (12 insulators vertical type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately)
Material and labour for switch air break gang operated triple pole mechanically operated, mounted on HT insulators (09 insulators horizental type operated) and MS galvanized steel frame with operating mechanism worked from ground level including operating rod for current rating up to 200 Amps 11000 volts complete with locking arrangement MS clamps, bolts and nuts and washers etc also including drop out expulsion type of fuses with fuse barrels of required capacity to suit load at site including two coats of aluminum paint over a coat of red oxide primer on MS work and including taking down old switch air break gang operated complete all as specified. (stack for fixing with poles shall be measure and paid separately)
S&F in repair, pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified & directed by Engineer-in-charge.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 Sqmm.
Supply & laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 95 Sqmm 3.5 Core complete all as specified and directed by Engr-in-charge.
Supply & laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 50 Sqmm 3.5 Core complete all as specified and directed by Engr-in-charge.
Supply & laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 25 Sqmm 4 Core complete all as specified and directed by Engr-in-charge.
Supply & laying of XLPE insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 1100 volts grade 16 Sqmm 4 Core complete all as specified and directed by Engr-in-charge.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe etc not exceeding 10 sqm on plan and getting out in Soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge.
Excavation in trenches in Hard rocks exceeding 1.5 mtr deep and not exceeding 3 mtr wide for erection of poles all as specified and directed at site.
Returning, filling in, including, spreading, levelling, watering and well ramming excavated Soft/Disintegrated rock in layers all as specified & directed at site.
Removing excavated Soft/Disintegrated rock to distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engineer-in-Charge.
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. (Note :- For the purpose of payment only punned thickness will be measured).
Supplying and laying Jodhpur stone quarry faced stone slab cover 25 to 30 cm in width, 50 to 60 cm long and 40 to 50 mm thick, laid dry and abutting each other with gap between adjacent slab not exceeding 10 mm over under ground cables for protection complete all as specified & directed by Engineer-in-charge.
Supply ,Transportation, fixng and errection of prestressed cement concerte pole 11 mtr long, miximum cross section 152mmx152mm at top and 152mm x 260 mm at bottom class-9 conforming to IS 01678 and including making alternate white and black strips 30cm height (total No-05 Nos), primer two cots of synthetic enamle paint oer a coat of primer complte all as speficied and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of pole/struts etc including necessary form work all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:3:6) type C-2 using 40mm grade stone aggregate in foundation of stay assembly/pole including necessary form work all as specified and directed by Engineer-in-Charge.
M&L for plain cement concrete (1:2:4) type B-1 using 20mm grade stone aggregate for couping/encasing around of pole including necessary form work finished een and smooth without using extra cement all as specified and directed by Engineer-in-Charge.
Dismantling, taking down and removing the old existing unsv non-functional/broken hinges of any description and in any postiion of existing feeder piller boxes/panel boards/feeder pillar boxes etc and supplying and fixing new cold rolled 100mm long medium weight mild steel but hines in position with necessary spot welding etc including making necessary adjustment for free and smooth movement of panel and locking arrangments complete all as specified and directed by Engineer-in-Charge.
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shap, supply, fixing and febrication in existing, shap and size with and including 2 mm thick CRCA sheet and all jointing material such as nuts, bolts or washer and welding etc. NOTE : (i) The panel board repaired shall be made totally enclosed, weather proof/wemin proof for installing incoming/outgoing MCCB/Switch fuses/cable etc complete all as directed. (ii) The rates quoted by the contractor aredeemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board. (iii) The replaced porting shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer. (iv) The rates quoted by the contractor deemed to be with and including dismantling/taking out/removing carefully, any damaged part/portion of the feeder pillar box/panel board as directed.
Preparation of the old decorated existing external and internal steel surfaces fo feeder pillar boxes/panels/boards of any description and in any position including removal of disintegrated & deteriorated paint either by hand scrpping or by blow stopping as required and applying two coats of synthetic enameled paint (grey in colour) with using spray machine on old prepared surfaces complete all as specified and directed by Engineer-in-Charge.
Shifting of transformer of any capacity from Jaisalmer to new locations (Ascon Nodes & Dabla) Jaisalmer with all required T&P/Hydera including connections, testing etc complete all as directed by Engr-in-Charge.
star electricals
JASOL MAA ENTERPRISES
Sachiyay maa Electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .