Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹18.3 L
EMD Value
₹36,500
Closing Date
27 May 2020, 4:00 pmClosed
Ex.Engineer Electrical
Ex.Engineer Electrical SKIMS Soura
Providing Emergency lighting points and wall mount heaters in rooms of Sarai Ist at SKIMS Soura. Providing Emergency lighting point and wall mount heaters in rooms of in Sarai 2nd at SKIMS Soura. Providing and Laying of 95mm and 50 mm armou
2020_SKIMS_96248_1
eNIT SIMS HEE EET 11 of 2020-21 Dt.27.04.2020
Open Tender
Electrical Works
Item Rate
30 days
SKIMS Soura
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
Director Finance SKIMS
₹36,500
Yes
17 Sept 2020
29 Apr 2020
1 Jun 2020
29 Apr 2020
27 May 2020
29 Apr 2020
Amount
Providing, fixing of fresh lighting point (5-6 amp) exposed, using double locked PVC channel 25x1.6 mm thick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. pvc insulated copper wire (P+N+E) (Havells/Finolex/ Polycab/Paramount/ Paraflux make FR) complete with P/F of switch 5/6 amps F/T (SSK/Havell's Reo/anchor penta pc make) to be fitted on 3mm Bakelite sheet suitable size,M.S/Wooden box, rowel plugs & screws etc. complete Point.
Providing and laying of multi strand pvc insulated copper wire for carrying out heating points (Havells /Finolex/ Polycab/Paramount/Paraflex make FR) (Excluding the cost of conduit)
3x2.5mm² multi strand pvc insulated copper.
Providing and laying of circuit wire using multi strand pvc insulated copper wire (Havells /Finolex/ Polycab/Paramount/Paraflux make FR)
2x16 mm² + 1x16mm² PVC multistrand Copper wire
2x10 mm² + 1x10mm² PVC multistrand Copper wire
Providing/fixing of double locked 25x2 mm thick PVC channel for circuit wiring and heating points ( Ravindra/Polycab/ Atul make)
Providing and fixing of bakelite /Phenolic Laminated Sheet 3 mm thick of different sizes.(Hylum/Formica make)
Providing & fixing of 1200 mm LED batten 6000/6500k Light having extruded aluminium heat sink body with anti-glare diffuser with energy efficient electronic driver CRI greater than 85 with minimum sytem lumens 2000 and maximum wattage 22 including connection with multistrand copper conductor 3 core cable. The job includes p/f of 2/3 pin ceiling rose over phenolic laminated sheet .(Havells/Philips/Trilux/Wipro make)
Providing and fixing of MS box 6"x9"
Supply and fixing of following Electrical accessories ( SSK/ Havells Reo/ Anchor Penta PC make)
15 Amp Switch socket combine
Providing Fixing Testing & commissioning of Wall mount Heat Convertor 2000 watt 220 Volt SP with remote control to be installed on the wall (Olumpus/Usha/Bajaj/Warmax Make )
Supplying and fixing following rating, 240/415 volts, “C”curve,10KA miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Legrand/Schneider acti -9/Siemens/Beta guard make)
a) MCB 40 Amp DP
b) 63 Amp TPN
Providing and fixing following rating and breaking capacity and Four pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.. (Legrand /Hager/ Schiender NSX/Siemens(3VL) make )( Adjustable range from .8 to1) along with enclosure. a) MCCB 125 A having 25KA B/capacity
Supplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper insulated bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (SSK/Havells/ anchor panasonic /Schneider make).
4 way TPN
Fabrication, Supply,installing & commissioning of copper Bus bar 200 amps 4 way of size 2 ftx2 ftx1 ft wall mounted ( Industrial Busbar chamber complete) with nuts bolts and each bus dully insulated as R,Y,B and N. (complete as per site requirement)
PART-B
Providing, fixing of fresh lighting point (5-6 amp) exposed, using double locked PVC channel 25x1.6 mm thick with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. pvc insulated copper wire (P+N+E) (Havells/Finolex/ Polycab/Paramount/ Paraflex make FR) complete with P/F of switch 5/6 amps F/T (SSK/Havell's Reo /Anchor penta pcmake) to be fitted on 3mm Bakelite sheet suitable size,M.S/Wooden box, rowel plugs & screws etc. complete Point.
Providing and laying of multi strand pvc insulated copper wire for carrying out heating points (Havells /Finolex/ Polycab/Paramount/Paraflex make FR) (Excluding the cost of conduit)
3x2.5mm² multi strand pvc insulated copper.
Providing and laying of circuit wire using multi strand pvc insulated copper wire (Havells /Finolex/ Polycab/Paramount/Paraflex make FR)
3x10 mm² (3Phase) + 1x10mm² (neutral) + 1x10mm² (Earth wire) for Sub DB from main panel.
Providing/fixing of double locked 25x2 mm thick PVC channel for circuit wiring and heating points ( Ravindra/Polycab/ ATUL make)
Providing and fixing of bakelite /Phenolic Laminated Sheet 3 mm thick of different sizes.(Hylum/Formica make)
Providing & fixing of 1200 mm LED batten 6000/6500k Light having extruded aluminium heat sink body with anti-glare diffuser with energy efficient electronic driver CRI greater than 85 with minimum sytem lumens 2000 and maximum wattage 22 including connection with multistrand copper conductor 3 core cable. The job includes p/f of 2/3 pin ceiling rose over phenolic laminated sheet .(Havells/Philips/Trilux/wipro make).
Providing and fixing of MS box 6"x9"
Supply and fixing of following Electrical accessories ( SSK/ Havells Reo/ Anchor Penta PC make)
15 Amp Switch socket combine
Providing Fixing Testing & commissioning of Wall mount Heat Convertor 2000 watt 220 Volt SP with remote control to be installed on the wall (Olumpus/Usha/Bajaj/Warmax Make )
Supplying and fixing following rating, 240/415 volts, “C”curve,10KA miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Legrand/Schneider acti -9/Siemens/Beta guard make)
a) MCB 40 Amp DP
b) 63 Amp TPN
Providing and fixing following rating and breaking capacity and Four pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.. (Legrand /Hager/ Schiender NSX/Siemens(3VL) make )( Adjustable range from .8 to1) along with enclosure. a) MCCB 125 A having 25KA B/capacity
Supplying and fixing following way, single pole and neutral, sheetsteel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper insulated bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (SSK/Havells/Anchor Panasonic /Schneider make)
4 way TPN
Fabrication, Supply,installing & commissioning of copper Bus bar 200 amps 4 way of size 2 ftx2 ftx1 ft wall mounted ( Industrial Busbar chamber complete) with nuts bolts and each bus dully insulated as R,Y,B and N.
PART_C
Providing and laying of spans of 3 ½ core XLPE / PVC insulated Al. cable Armoured of various sizes as mentioned below. (Polycab/ Havells/ Gloster/ Paramount make)
a) 95 mm sq. 3 ½ core
b) 50 mm sq. 3 ½ core
Providing and making of end termination of the following 3 ½ Al. cable including Thimbling, crimping tapping, testing and connecting as per site requirements (Dowels/3D make)
a) 95 mm sq. 3 ½ core
b) 50 mm sq. 3 ½ core
Fabrication Providing & fixing of iron hoos fabricated from 40mm x40mm x5mm for laying/fixing of cables. (60 no.)
M/S ELCO ENTERPRISES
M/S BHAT SYNDICATE
M/S ZAHID ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .