Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹23.3 L+₹34,950 (1.52%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹23.4 L+₹50,493 (2.20%)Rejected-Finance 96 1 HIMMATGANJ BEHIND UNANI MEDICAL COLLEGE PRAYAGRAJ 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹23.9 L+₹95,098 (4.15%)Rejected-Finance 20 8 EWS PREETAM NAGAR COLONY ALLAHABAD | PRAYAGRAJ | UTTAR PRADESH | 211001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹26.7 L+₹3.8 L (16.7%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | L5 | Rejected-Finance Being L5 |
Tender Value
₹49.4 L
EMD Value
₹99,000
Closing Date
22 Dec 2022, 6:00 pmClosed
GE (East) Allahabad
Stanley Road, Teliyarganj, Allahabad
Repair/replacement of main distribution board/submain wiring, heating appliances and servicing of DG set at Old Cantt and Fort Cantt Allahabad.
2022_MES_566182_1
8608/E8
Open Tender
Civil Works
Item Rate
270 days
Allahabad
As Per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (East) Allahabad
₹99,000
Yes
2 Mar 2023
30 Nov 2022
24 Dec 2022
30 Nov 2022
22 Dec 2022
15 Dec 2022
Amount
Periodical servicing of diesel engine driven Gen set 3 phase 415 volts 50 c/s AC supply by cleaning thoroughly and replacing fuel filters, air filters, oil filters & draining out engine oil etc. and replacing with new oil, tightening of all gaskets, connection of battery terminals, electric cable connections, foundation bolts, coupling bolts etc including test running and tappet setting of alternator by checking and setting of voltage and frequency, complete all as specified and directed. MAKE OF DG SET : Kirloskar/ Crompton greaves/Cummins. Make of filters : Kirloskar/ CG/ Fleet guard/ MICO Note:Engine oil, Fuel filters, Air filters, oil filters replaced will be measured and paid separately under respective item of sch 'A' . for following capacities of DG set:
320 KVA DG SET
160 KVA DG SET
100 KVA DG SET
63/62.5 KVA DG SET
40/50 KVA DG SET
25/30 KVA DG SET
18/20 KVA DG SET
Supply and fixing in replacement of maintenance free battery with initially charged capacity 180 AH , 12 Volt complete all as specified and as directed. Make :- Exide/Amron
Supply and fixing in replacement of maintenance free battery with initially charged capacity 150 AH , 12 Volt complete all as specified and as directed. Make :- Exide/Amron
Supply and fixing in replacement of maintenance free battery with initially charged capacity 90 AH , 12 Volt complete all as specified and as directed Make :- Exide/Amron
Replacement of UNSV radiator hose pipe set complete as per sample of DG set of following capacity:
320 KVA DG SET. Make :Greaves Cat part No. P21108610044
160 KVA DG SET . Make :Greaves Cat part No. P21108610044
100 KVA DG SET . Make :Greaves Cat part No. P21108610044
63/62.5 KVA DG SET . Make :Greaves Cat part No. P21108610044
40/50 KVA DG SET . Make :Greaves Cat part No. P21108610044
25/30 KVA DG SET . Make :Greaves Cat part No. P21108610044
18/20 KVA DG SET . Make :Greaves Cat part No. P21108610044
Replacement of UNSV fan belts as per sample for DG sets of following capacity: MAKE: Fenner/ Grip/ Dunlop/Kiloskar
Fan belt for 320 KVA DG Set. Make: Fenner cat part No. 02.071.01.00
Fan belt for 160 KVA DG Set. Make: Fenner cat part No. 02..1266.01.00
Fan belt for 100 KVA DG Set. Make: Fenner cat part No. 02..1266.01.00
Fan belt for 63/62.5 KVA DG Set. Make: Fenner cat part No. 02..1266.01.00
Fan belt for 40/50 KVA DG Set. Make: Fenner cat part No. 02.1266.01.00
Fan belt for 25/30 KVA DG Set. Make: Fenner cat part No. 02.542.02.00
Fan belt for 18/20 KVA DG Set. Make: Fenner cat part No. 02.637.01.00
Replacement of stranded copper conductor battery lead for 24 volts D C grade red for (+)ve terminal and black for (-)ve terminal fitted with battery terminal at one end & battery lug at other end complete length 1.5 mtr, complete all as specified and directed.
Cleaning of radiator by cleaning agent/ Radiwash (Make: fleetguard/ coolguard) including removal/ dismantling of radiator from engine transporting to work shop or cleaning at site, soldering / brazing, testing for any leakage , remounting to its original position as per entire satisfaction of Engr - in-charge for following capacity of DG Set.:
160 KVA DG SET
100 KVA DG SET
63/62.5 KVA DG SET
40/50 KVA DG SET
25/30 KVA DG SET
18/20 KVA DG SET
Replacement of set of hose clips for DG sets of following capacity:
320 KVA DG SET
160 KVA DG SET
100 KVA DG SET
63/62.5 KVA DG SET
40/50 KVA DG SET
25/30 KVA DG SET
18/20 KVA DG SET
Coolant radicool SFO premix of Castrol or equivalent of TVS/ Volvoline, complete all as specified and directed.
Draining out of the old used engine oil from sump of DG sets & cleaning & refilling with new engine oil 15 W 40 up to required level including topup, complete all as specified and directed. Make : Castrol/ HP or equivalent of Servo
Replacement of defective self starter assembly by new self starter assembly 12/24 volts, complete all as specified and directed. Make: Lucas Cat Part No. 03.034.101 / Bosch
Replacement of defective alternator assembly by new alternator assembly 12/24 volts, complete all as specified and directed. Make Lucas Cat partv No. 03.130.01/ Boss/PMG
Replacement of PCB card Procom R E L-7-1.0 for 160/100 KVA AMF pannel, complete all as specified and directed. Make: OSRAM Cat Part No. 03.963.66
Replacement coil Relay-24 volts,5 Amp 240 volt AC 5Amp 30 volts DC model HJQ 22 F –VZ, complete all as specified and directed. Make: YOI Cat part No. 03.963.76 / Siemens for 160/100 KVA AMF pannel
Replacement of timer switch 0 to 80 seconds, complete all as specified and directed. Make : Asian/ Ticnner for 160/100 KVA AMF pannel
Servicing of DG set 160 KVA AMF panel, setting of time delay switch , tightening of all electrical incoming & outgoing connections including replacement of cable lugs & adjustment of solenoid switches & relays, complete all as specified and directed.
Servicing of DG set 100 KVA AMF panel, setting of time delay switch, tightening of all electrical incoming & outgoing connections including replacement of cable lugs & adjustment of solenoid switches & relays, complete all as specified and directed.
Painting of Generating set of capacity 100 KVA to 320 KVA complete in existing colour with two coat of synthetic enamelled paint by spray machine over one coat of primer after preparation of surfaces, complete all as specified and as directed.
Painting of Generating set of capacity 18 KVA to 63 KVA complete in existing colour with two coat of synthetic enamelled paint by spray machine over one coat of primer after preparation of surfaces, complete all as specified and as directed.
Euroload four pole change over with advance Neutral On load change over switch I-O-II , Current Rating 100 Amps, 415 Volts, fixed in repair, complete all as specified and directed. Make: Havells/ Indoasian/ C&S.
Euroload four pole change over with advance Neutral On load change over switch I-O-II , Current Rating 200 Amps, 415 Volts, fixed in repair, complete all as specified and directed. Make: Havells/ Indoasian/ C&S.
Euroload four pole change over with advance Neutral On load change over switch I-O-II , Current Rating 400 Amps, 415 Volts, fixed in repair, complete all as specified and directed. Make: Havells/ Indoasian/ C&S.
Supply only Diesel Filter suitable for 18 KVA to 100 KVA DG set, complete all as specified and directed. Make - Kirloskar Cat part No. 02.102.03/ CG/ KG/ Cummins.
Supply only Diesel Filter suitable for 160 KVA to 320 KVA DG set, complete all as specified and directed. Make - Kirloskar Cat part No,02.102.03/ CG/ KG/ Cummins
Supply only Lub Oil filter suitable for 18 KVA to 100 KVA DG set, complete all as specified and directed. Make - Kirloskar Cat part No. 03.040.08 / CG/ KG/ Cummins.
Supply only Lub Oil Filter suitable for 160 KVA to 320 KVA DG set, complete all as specified and directed. Make - Kirloskar Cat Part No.03.040.08 /CG/KG/Cummins
Supply only Air filter suitable for 18 KVA to 100 KVA DG set, complete all as specified and directed. Make - Kirloskar Cat part No. 30.0610.20/CG/KG/Cummins
Supply only Air Filter suitable for 160 KVA to 320 KVA DG set, complete all as specified and directed. Make - Kirloskar Cat part No. 30.0610.20/CG/KG/Cummins
Supply & fixing spare parts & accessories of original make for repair of DG set under serial items No 1(iv) here-in-before all as directed :- 03 Nos DG sets Notes :- All spares & accessories shall be fixed in the DG set only after prior inspection & Approval of Engineer-in-Charge for which these shall be produced by the contractor at store yard of AGE E/M Old Cantt.
Kit Fuel filter Cat Part No. 3H.123.01.00
Kit Lub oil filter Cat Part No. 064.36.01.00
Kit bypass filter Cat Part No.3H.133.01.00
Kit Air cleaner Cat Part No.4H11.98.02
Air filter Cat Part No. 4H11.98.01
Upper Gasket set (Cylinder head) Cat Part No. 4H.007.24.00
Valve exhaust Cat Part No. 4H.007.400.00
Valve inlet Cat Part No. 4H.007.300.00
Valve seat Exhaust Cat Part No. 4H.007.03..00
Valve seat Inlet Cat Part No. 4H.007.04.00
Guide valve Cat Part No. 4H.007.020.00
Collet Volve Cat Part No. 02.0024.01.0.00
Spring valve Cat Part No. 50540/09X016
Kit turbo charging Cat Part No. 6H.029.10.000
Collar thrust Cat Part No. 6H.001.03.000
Kit injector Cat Part No. 4H.154.10.000 (MICO)
Kit Piston and ring set Cat Part No. 4H.180.01.000/ZH.0009.02.0.00
Kit Cylinder liner Cat Part No. 2H.008.07.0.00
Kit Sump Gasket Cat Part No. 06.074.20.0.00
Gear pump assembly (Fuel pump FIP) Cat Part No. 2H.011.01.0.00
Weight & carrier Cat Part No. Nil
Barrel sleave Cat Part No. 02.035.07.000
Gasket Set Cat Part No. 6H
Sexen filter Cat Part No. Nil
Gear assembly Cat Part No. 6h.020.01.0.00
Ball bering Cat Part No. 6305
Head gasket Cat Part No. 6h.02.001
Nozzle
Block Cat Part No. 6H.001.25.0.00
Liner Cat Part No. 2H.008.01.0.00
Battery terminal
Packing Kit Cat Part No. 4H.0.87.40.0
Crank Cat Part No. 6H.0002.00.00
Main bearing Cat Part No.6H.001.06.0.00
CR bearing Cat Part No. BO.73.400
Came bush Cat Part No. 03.001.04.0.00
Connecting Rod Cat Part No. 4H.182.10.0.00
Rod balancing Cat Part No. Nil
Bush Cat Part No. 4H.182.02.000
Third washer Cat Part No. 6H.001.03.0.00
Valve seal Cat Part No. 06.631.02.000
Supply & fixing spare parts & accessories of original make for repair of DG set under serial items No 1(vi) here-in-before all as directed :- 01 Nos DG sets Notes :- All spares & accessories shall be fixed in the DG set only after prior inspection & Approval of Engineer-in-Charge for which these shall be produced by the contractor at store yard of AGE E/M Old Cantt.
Kit Fuel filter Cat Part No. 3R.123.01.00
Kit Lub oil filter Cat Part No. 034.36.01.00
Kit bypass filter Cat Part No.3R.133.01.00
Kit Air cleaner Cat Part No. 3R1198.02.00
Air filter Cat Part No.4R.11.98.01.00
Upper Gasket set (Cylinder head) Cat Part No. 3R.007.24.00
Valve exhaust Cat Part No. 3R.007.400.00
Valve inlet Cat Part No. 3R.007.300.00
Valve seat Exhaust Cat Part No. 3R.007.03..00
Valve seat Inlet Cat Part No. 3R.007.04.00
Guide valve Cat Part No. 3R.007.020.00
Collet Volve Cat Part No. 03.0024.01.0.00
Spring valve Cat Part No. 50540/09X016
Kit turbo charging Cat Part No. 3R.029.10.000
Collar thrust Cat Part No. 3R.001.03.000
Kit injector repair Cat Part No. 3R.154.10.0.00 (MICO)
Kit Piston and ring set Cat Part No. 3R.180.01.000/ZH.0009.02.0.00
Kit Cylinder liner Cat Part No. 3R.008.07.0.00
Kit Sump Gasket Cat Part No. 03.074.20.0.00
Gear pump assembly (Fuel pump FIP) Cat Part No. 3R.011.01.0.00
Weight & carrier Cat Part No. Nil
Barrel sleave Cat Part No. 03.035.07.000
Gasket Set Cat Part No. 3R
Sexen filter Cat Part No. Nil
Gear assembly Cat Part No. 3R.020.01.0.00
Ball bering Cat Part No. 3305
Dismantling of DG Set Alternator of cap 63/ 62.5 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M, complete all as specified and directed which includes following works:
Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, Nomex paper, cotton tape, glass sleeve, soldering rod, grease etc, complete all as specified and directed.
Repairing of armature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete all as specified and directed.
Supply and replacing Ball bearing at DE (Driven End) side of No.6310, complete all as specified and directed. Make- NBC/ SKF -01 No
Supply and replacing rectifier Diod
Supply and replacing AVR (Automatic Voltage Regulator).
Supply and replacing connection plate of suitable size.
Dismantling of DG Set Alternator of cap 100/160 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as direted which includes following works:
Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, Nomex paper, cotton tape, glass sleeve, soldering rod, grease etc, complete all as specified and directed.
Repairing of armature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete.
Supply and replacing Ball bearing at DE (Driven End) side of No.6310 / 6311/ 6312/ 6314, complete all as specified and directed. Make- NBC/ SKF
Supply and replacing rectifier Diod.
Supply and replacing AVR (Automatic Voltage Regulator). TVR-20
Supply and replacing connetion plate of suitable size.
Dismantling of DG Set Alternator of cap 25/30/40 KVA carefully and carry to authorised workshop for repair and re-fixing the same in its original position after repair and testing the same up to satisfaction of AGE E/M complete all as direted whick includes following works:
Cutting out old burnt winding of alternator, cleaning the slot of stator and rewinding the same with super enamelled copper winding wire of appropriate gauge complete with all insulating materials, Nomex paper, cotton tape, glass sleeve, soldering rod, grease etc, complete all as specified and directed.
Repairing of armature shaft both side by depositing metal on it, grinding & polishing to make appropriate size of the shaft complete.
Supply and replacing Ball bearing at DE (Driven End) side of No.6310 / 6311/ 6312/ 6314, complete all as specified and directed. Make- NBC/ SKF
Supply and replacing rectifier Diod.
Supply and replacing AVR (Automatic Voltage Regulator)
Supply and replacing connection plate of suitable size.
MCCB 160 Amps, 415 Volts, 4 Pole, breaking capacity 16/25 KA, ISI Marked, fixed type, fixed in repair, complete all as specified and directed.
MCCB 250 Amps, 415 Volts, 4 Pole, breaking capacity 25KA, ISI Marked, fixed/ adjustable type, fixed in repair, complete all as specified and directed.
Taking down main switches, distribution boards and cut outs of any capacity along with the exisitng boards and removing the same from site and keeping in safe custody for reuse or issue on credit to contractor and making good disturbed surface or portion of walls, complete all as specified & directed.
Taking down carefully sub main wiring of any numbers of wire on wooden batten or surface conduit or concealed conduits / casing caping any type, complete all as specified & directed.
Sub main wiring with two single core PVC insulated unsheathed, grade cable 4.0 sq.mm (nominal area) FRLS type multi stranded copper conductor and one run of 4 sq.mm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS including provision of cutting chases for conduit and sinking for boxes including making good to walls disturbed surfaces and applying finishes to match existing surfaces and laying through and including provision of 20mm dia 'medium grade' PVC conduit and fittings, complete all as specified and directed. NOTE:- (i) Two runs of 4 sq.mm copper conductor, one run of 4 sq.mm copper earth continuity conductor and one run of PVC conduit and its fittings shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring with two single core PVC insulated unsheathed, grade cable 6.0 sq.mm (nominal area) FRLS type multi stranded copper conductor and one run of 6 sq.mm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS including provision of cutting chases for conduit and sinking for boxes including making good to walls disturbed surfaces and applying finishes to match existing surfaces and laying through and including provision of 20mm dia 'medium grade' PVC conduit and fittings, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC conduit and its fittings shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring with two single core PVC insulated unsheathed, grade cable 6.0 sq.mm (nominal area) FRLS type multi stranded copper conductor and one run of 6 sq.mm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS and including provision of cutting chases for sinking for boxes inlcuding making good to walls disturbed surfaces and applying finishes to match existing surfaces and including laying in and including provision of 20mm wide PVC suface casing and caping and fittings, complete all as specified and directed. NOTE:- (i) Two runs of 6 sq.mm copper conductor, one run of 6 sq.mm copper earth continuity conductor and one run of PVC casing and caping and its fittings shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Sub main wiring with four single core PVC insulated unsheathed, grade cable 16.0 sq.mm (nominal area) FRLS type multi stranded copper conductor and two runs of 16 sq.mm nominal cross sectional area FRLS PVC insulated unsheathed multistranded copper conductor green colour as continuous earth wire connected to common earth as per IS including provision of cutting chases for conduit and sinking for boxes including making good to walls disturbed surfaces and applying finishes to match existing surfaces and laying through and including provision of 32mm dia 'medium grade' PVC conduit and fittings, complete all as specified and directed. NOTE:- (i) Four runs of 16 sq.mm copper conductor, two runs of 16 sq.mm copper earth continuity conductor and one run of PVC conduit and its fittings shall be measured as one unit length. (ii) Extra length of cable / wire required for connection to MCBs shall not be measured and the rate quoted per unit shall deemed to be inclusive of the same accordingly.
Earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground vertically to a depth of not less than 2.25m deep below ground level with the top edge of earth plate at a depth of not less than 1.5m below ground level connected to GI earth lead of 4mm dia by means of bolts, nuts, washers of galvanised iron or steel, GI earth wire shall be protected by 15mm dia GI pipe 'light grade', GI wire meshed funnel, alternate layer of charcoal and salt on all side to earth plate upto a thickness of 150mm, filling of black cotton soil in earth pit upto GL and connected to earth plate including necessary excavation & earthwork, PCC (1:3:6) type C-1 earth chamber and mild steel angle iron frame 40 x 40 x 3 mm and 40mm thick pre-cast RCC cover (1:2:4), type B-1 (using 20mm graded crushed aggregate) mix with 8mm dia MS bars @75mm c/c both ways, mild steel handle 12mm dia, PGI funnel and wire mesh, 15mm dia GI pipe 'medium' grade(ISI marked) for watering, etc complete all as shown in electrical plate No.3 connected to earthing test point, including testing on completion, complete all as speciifed and as directed. NOTE:- The quoted rates shall also deemed to include the cost of Earth Test point and earth wire and protection pipe upto 7.5 metre beyond the earth plates electrode.
Taking down carefully existing geyser of any capacity after disconnecting all electrical and water supply connection and removing the geyser & bring to E&M store yard for opening the geyser, cleaning all the serviceable parts throughly including descaling the geyser, replacing the defective/ wornout parts/ material reassembling the geyser after repair testing for proper functioning, including re-fixing the same in position and reconnecting the geyser with electric and water supply line and testing as directed, complete all as specified and directed. NOTE:- Spare parts required for replacement shall be measured and paid separately .
Repair to leakage of inner tank 25/50 litre capacity geyser by brazing or soldering, including cutting of nut, bolt, washer etc, as required with gas welding cutter and provinding new nut, bolt, washer etc including testing of leakage of tanks, complete all as specified and directed.
Inner tank made of MS 1.6 mm thick suitable for 25 litre capacity geyser, complete all as specified and directed.
Inner tank made of MS 1.6 mm thick suitable for 50 litre capacity geyser, complete all as specified and directed.
Apperture plate assembly suitable for 25 litre capacity geyser, complete all as specified and directed.
Apperture plate assembly suitable for 50 litre capacity geyser, complete all as specified and directed.
Outer body of geyser made of 1.25 mm thick MS sheet suitable for 25 litre capacity geyser, complete all as specified and directed.
Outer body of geyser made of 1.25 mm thick MS sheet suitable for 50 litre capacity geyser, complete all as specified and directed.
Bottom cover for geyser in two pieces made of MS sheet in required/ existing size and shape suitable for 25 litres capacity geyser including painting of two coats synthetic enamel paint over a coat of primer to match the existing, complete all as specified and directed.
Bottom cover for geyser in two pieces made of MS sheet in required/ existing size and shape suitable for 50 litres capacity geyser including painting of two coats synthetic enamel paint over a coat of primer to match the existing, complete all as specified and directed.
Heating element threaded/ screwed/ triangular or cup style type 1500 Watt ISI marked of suitable make without taking down Geyser, fixed in repair, complete all as specified and directed.
Heating element threaded/ screwed/ triangular or cup style type 2000 Watt ISI marked of suitable make without taking down Geyser, fixed in repair, complete all as specified and directed.
Thermostat suitable for 25 or 50 litre capacity of geyser, range 20 to 80 degree ISI marked, without taking down geyser, fixed in repair, complete all as specified and directed.
PVC connection cotton braided heavy duty with brass union/ coupling of length 450 mm with rubber washer suitable for 15 mm dia pipe for hot or cold water connection, without taking down geyser, fixed in repair, complete all as specified and directed.
Indicator lamp assembly with bulb suitable for geysers round or square type of approved make and quality as approved, without taking down geyser, in repair, complete all as specified and directed.
Bib taps, cast copper alloy, chromium plated, fancy type, capstain head handle, screwed down, screwedat one end, 15mm bore, in repair, complete all as specified and directed.
Stop valves, cast copper alloy, screwed down, high pressure, with capstan head handle, screwed both ends for iron pipe or for unions and fixed, chromium plated, 15 mm bore, in repair, complete all as specified and directed.
One coat painting of Geyser at site by spray gun painting (without taking down Geyser) of 25 litre capacity with synthetic enamel paint including preparation of old surface and re-writing or marking MES number, complete all as specified and directed.
One coat painting of Geyser at site by spray gun painting (without taking down Geyser) of 50 litre capacity with synthetic enamel paint including preparation of old surface and re-writing or marking MES number, complete all as specified and directed.
Taking down solar water heating system panel of 200 litres capacity, any make and type carefully for cleaning dust, cleaning the water collector tubes including descaling the existing hot water storage tank of any capacity and refixing after repair complete all as specified and directed. Note:- Spare part shall be measured & paid seperately.
Gun metal globe or gate valve, 15mm bore, complete all as specified and directed.
Non return valve 15mm dia made of bronze ISI marked heavy duty, complete all as specified and directed.
Zebra fastener of size 12x100 mm, complete all as specified and directed.
Spring loaded air release safety valve made of brass as per existing shape and size of approved make, fixed in replacement, complete all as specified and directed.
Solar water heater storage tank of capacity 200 litre with MS stand of strandard size, inletoutlet, over flow water pipe connections complete with nuts and bolts of suitable size and PCC work in 1:2:4 ratio as required at site including taking down old unserviceable, fixed in replacement, complete all as specified and directed.
Flexible copper wire 3 core of size 40/0.0076/2.5 sqmm, 1100 volt and making electric connection in geyser, complete all as specified and directed.
Plug top of 15/16 Amps, 230 Volt capacity, three pin, complete all as specified and directed.
Switch piano, single pole one way 15/16 Amps flush type, complete all as spicified and directed.
Piano type socket, 2 in 1, 5/15 Amps, 230 V capacity, complete all as specified and directed.
Plug top of 20 Amp capacity, complete all as spicified and directed.
MCB SP, 32 Amp capacity, 240 Volt, conforming to 'B' curve, 10KA breaking capacity and making connections for separate geyser circuit from main distribution board to geyser socket, fixed in repair, complete all as specified and directed.
Single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with & including one number MCB SP 20/25 Amps, complete all as specified and directed.
SPN Distribution Boards, double door, 8 way, 230 Volts, complete all as specified and directed.
VTPN DB, double door, 4 way, 415 Volts suitable for MCCB upto 125 A, insulated busbar assembly and neutral bar complete with IP-43 protection, complete all as specified and directed.
MCB TPN, 415 Volts, 63 Amps, complete all as specified and directed.
MCB TPN, 415 Volts, 100 Amps, complete all as specified and directed.
MCCB, TP, 125 Amps suitable for VTPN, complete all as specified and directed.
MCB SPN, 230 Volts, 32 Amps, conforming to C curve, complete all as specified and directed.
MCB SPN, 230 Volts, 40 Amps, confirming to C curve, complete all as specified and directed.
Ambrish Builders
M/S SHIV BALLABH MISHRA
Mohit Enterprises
M/s A.K Construction
K R GUPTA AND SONS
Minakshi constuction co.
Shivam Constructions
PITAMBARI TRADERS
Bharat Trading Company
RK Enterprises
Raj Contruction
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .