| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L2₹29.1 L+₹11.6 L (66.4%)Qualified Make: DYNAMIC KARE
Model: DCMS-8000 EL 66 EL 66 INDUSTRIAL AREA ELECTRONICS ZONE MAHAPE NAVI MUMBAI ELECTRONIC ZONE THANE MAHARASHTRA 400710 | THANE | MAHARASHTRA | 400710 | Make: DYNAMIC KARE
Model: DCMS-8000 | L2 | Qualified | |
| 2 | Qualified Make: NA
Model: MAESTROS MODEL IRIS50 EL 66 EL 66 INDUSTRIAL AREA ELECTRONICS ZONE MAHAPE NAVI MUMBAI ELECTRONIC ZONE THANE MAHARASHTRA 400710 | THANE | MAHARASHTRA | 400710 | Make: NA
Model: MAESTROS MODEL IRIS50 | - | Qualified | |
| 3 | L1₹17.5 LDisqualified Make: MAESTROS
Model: Maestros IRIS 50 19 MAHADEV TOTALA NAGAR INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | Make: MAESTROS
Model: Maestros IRIS 50 | L1 | Disqualified | |
| 4 | Disqualified Make: TECHNOCARE MEDISYSTEMS
Model: Technocare Medisystem Other 1 PROP SINGHAL MEDICAL AGENCIES OPP GAYATRI MANDIR A B ROAD GUNA MADHYA PRADESH 473001 | GUNA | MADHYA PRADESH | 473001 | Make: TECHNOCARE MEDISYSTEMS
Model: Technocare Medisystem Other | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
14 May 2018, 6:00 pmClosed
acute care monitoring units and related products- patient monitors Average Turn Over of Last 3 Years 100 Lakh (s) Experience with Gov. Required 3 Year (s) Acute Care Monitoring Units And Related Products-patient Monitors ( 50 ) Technical Specifications Specification Specification Name Values Allowed Values NEW SET Type of Monitor Preconfigured/Non Modular N/A Functional Requirements: Operates from mains voltage or from internal rechargeable battery Operator can set audio visual alarm levels for low or high levels of each parameter independently Allows display of single
3 lead ECG or simultaneous display of at least 5 waves ECG selected from up to 12 points Display to be digital of all active parameters and trace display for at least three selectable parameters Yes N/A Clinical Purpose: Designed to YES N/A 1/7 continuously measure and display multiple vital physiological parameters of adults
newborn and premature infants
especially those under critical care Continuous display on screen of neonatal or infant ECG
respiration and heart rates
invasive/non-invasive blood pressure
body temperature and SpO2 Yes N/A Patient monitor offered with option to monitor parameter(s): EtCO2
IBP
Cardiac Output EtCO2
Cardiac Output Number of leads for ECG 5 3
5
12 Screen Size 15 8
12
14
15
17 Weight 5 N/A ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable
external skin contact type; Temperature range at least 30 to 40 deg C
minimum gradation (1/10) deg C/Heart rate measurement range to be at least 30 to 250 bpm
with accuracy better than ± 5 bpm and minimum gradation 1 bpm/SpO2 measurement range at least 40-70 % and 70 to 99 %
with accuracy better than ± 1% for 40-70 range and better Yes N/A 2/7 than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring range at least 30 to 300 mmHg
minimum gradation 1 mmHg Respiration rate measurement range at least 0 to 100 bpm
minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours to be selectable ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable
with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring range at least 30 to 300 mmHg
minimum gradation 1 true N/A 3/7 bpm/Trend display of each parameter over at least previous 24 hours to be selectable/TFT Screen User Interface Manual through knob or key board Manual through knob or key board
Through touch Screen
remotely operated Audio Visual alarms high and low levels for each parameter (operator variable settings)
sensor/wire probe disconnected
low battery N/A Case is to be hard and splash proof/Display must allow easy viewing in all ambient light levels/Cable connectors to be designed so as fit correct socket only Yes N/A Noise (in dB) < 50 N/A Heat Dissipation: Should maitain nominal Temp and the heat should be disbursed through adequate arrangement N/A Mobility & Portability mobile and portable in protective case supplied for clean storage and safe transport. N/A Power supply Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt
50 Hz AC both 220 volt
50 Hz AC
replaceable and rechargeable Battery Operated (Min one hour operation support in the event of power failure)
Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt
50 Hz AC both Mains cable to be at least 3m length YES N/A Accessories & Spare Parts: pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 4/7 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe Operating condition: apable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances N/A Should be FDA CE/BIS approved product European CE US FDA
European CE
BIS - Electrical safety conforms to standards for electrical safety IEC-60601-1/- Shall meet IEC-60601-1-2 (General requirements for safety - electromagnetic compatibility)/-Also conforms to IEC 60601-2- 27 (Particular requirements for the safety of electrocardiographic monitoring equipment) - Manufacturer supplier should have ISO certificate for quality standard/- Shall meet IEC 60601-2-49 multi function patient monitoring equipment standard requirement Yes N/A Seller to perform supply
installation
safety & operation checks and training before handover of the product [Training of users in operation and basic maintenance shall be provided] Yes N/A Warranty Comprehensive warranty of 3 years with free servicing ( N/A 5/7 min 3/year) during warranty Operating manuals
service manuals
other manuals/documents Advanced maintenance tasks required shall be documented User
technical and maintenance manuals to be supplied in English language. List to be provided of equipment and procedures required for local calibration and routine maintenance List to be provided of important spares and accessories
with their part numbers. Certificate of calibration and inspection to be provided. N/A Recommendations or warnings Any recommendations for best use and supplimentary warning for safety to be declared N/A Details of Item and test reports Availability of Test Report from Central Govt/NABL/ILAC/Any OPCW accredited lab to prove conformity to specification No N/A Test report (if indicated as available) to be furnished to buyer on demand YES N/A Test report No & date CE-2884 DATE 6/1/2017 N/A Name and address of the Lab: UK CERTIFICATION AND INSPECTION LIMITED
UK N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjeev Kumar 801507
AIIMS
Phulwarisarif
PATNA PIN-851507 50 15 EMD 6/7 Required No ePBG Required No
44580
GEM/2018/B/6353
acute care monitoring units and related products-patient monitors
15 days
Bihar; Patna
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| acute care monitoring units and related products- patient monitors Average Turn Over of Last 3 Years 100 Lakh (s) Experience with Gov. Required 3 Year (s) Acute Care Monitoring Units And Related Products-patient Monitors ( 50 ) Technical Specifications Specification Specification Name Values Allowed Values NEW SET Type of Monitor Preconfigured/Non Modular N/A Functional Requirements: Operates from mains voltage or from internal rechargeable battery Operator can set audio visual alarm levels for low or high levels of each parameter independently Allows display of single | - | - | - |
| 3 lead ECG or simultaneous display of at least 5 waves ECG selected from up to 12 points Display to be digital of all active parameters and trace display for at least three selectable parameters Yes N/A Clinical Purpose: Designed to YES N/A 1/7 continuously measure and display multiple vital physiological parameters of adults | - | - | - |
| newborn and premature infants | - | - | - |
| especially those under critical care Continuous display on screen of neonatal or infant ECG | - | - | - |
| respiration and heart rates | - | - | - |
| invasive/non-invasive blood pressure | - | - | - |
| body temperature and SpO2 Yes N/A Patient monitor offered with option to monitor parameter(s): EtCO2 | - | - | - |
| IBP | - | - | - |
| Cardiac Output EtCO2 | - | - | - |
| Cardiac Output Number of leads for ECG 5 3 | - | - | - |
| 5 | - | - | - |
| 12 Screen Size 15 8 | - | - | - |
| 12 | - | - | - |
| 14 | - | - | - |
| 15 | - | - | - |
| 17 Weight 5 N/A ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable | - | - | - |
| external skin contact type; Temperature range at least 30 to 40 deg C | - | - | - |
| minimum gradation (1/10) deg C/Heart rate measurement range to be at least 30 to 250 bpm | - | - | - |
| with accuracy better than ± 5 bpm and minimum gradation 1 bpm/SpO2 measurement range at least 40-70 % and 70 to 99 % | - | - | - |
| with accuracy better than ± 1% for 40-70 range and better Yes N/A 2/7 than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring range at least 30 to 300 mmHg | - | - | - |
| minimum gradation 1 mmHg Respiration rate measurement range at least 0 to 100 bpm | - | - | - |
| minimum gradation 1 bpm/Trend display of each parameter over at least previous 24 hours to be selectable ECG patient connectors that are sterilisable and reusable are acceptable though reusable cables that attach to disposable connection patches are preferred Multichannel (up to 12 leads) ECG measurement and selectable display of upto 5 leads at a time Temperature probe to be reusable | - | - | - |
| with accuracy better than ± 1% for 40-70 range and better than ± 3% for 70-99 range and minimum gradation 1%/Blood pressure monitoring range at least 30 to 300 mmHg | - | - | - |
| minimum gradation 1 true N/A 3/7 bpm/Trend display of each parameter over at least previous 24 hours to be selectable/TFT Screen User Interface Manual through knob or key board Manual through knob or key board | - | - | - |
| Through touch Screen | - | - | - |
| remotely operated Audio Visual alarms high and low levels for each parameter (operator variable settings) | - | - | - |
| sensor/wire probe disconnected | - | - | - |
| low battery N/A Case is to be hard and splash proof/Display must allow easy viewing in all ambient light levels/Cable connectors to be designed so as fit correct socket only Yes N/A Noise (in dB) < 50 N/A Heat Dissipation: Should maitain nominal Temp and the heat should be disbursed through adequate arrangement N/A Mobility & Portability mobile and portable in protective case supplied for clean storage and safe transport. N/A Power supply Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt | - | - | - |
| 50 Hz AC both 220 volt | - | - | - |
| 50 Hz AC | - | - | - |
| replaceable and rechargeable Battery Operated (Min one hour operation support in the event of power failure) | - | - | - |
| Replaceable And Rechargeable Battery Operated (Min One Hour Operation Support In The Event Of Power Failure) and 220 Volt | - | - | - |
| 50 Hz AC both Mains cable to be at least 3m length YES N/A Accessories & Spare Parts: pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 pairs of ECG cable 5 sets of ECG connection electrodes 1 unit each of reusable SPO2 4/7 probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe probe(Adult/Paediatric) 1 unit of SPO2 probe(Neo natal) 2 units of NIBP cuffs for adult 2 units of NIBP cuffs for Paediatric 1 unit each of skin and rectal Temperature probe Operating condition: apable of operating continuously in ambient temperature of 0 to 50 deg C and relative humidity of 15 to 90% in ideal circumstances N/A Should be FDA CE/BIS approved product European CE US FDA | - | - | - |
| European CE | - | - | - |
| BIS - Electrical safety conforms to standards for electrical safety IEC-60601-1/- Shall meet IEC-60601-1-2 (General requirements for safety - electromagnetic compatibility)/-Also conforms to IEC 60601-2- 27 (Particular requirements for the safety of electrocardiographic monitoring equipment) - Manufacturer supplier should have ISO certificate for quality standard/- Shall meet IEC 60601-2-49 multi function patient monitoring equipment standard requirement Yes N/A Seller to perform supply | - | - | - |
| installation | - | - | - |
| safety & operation checks and training before handover of the product [Training of users in operation and basic maintenance shall be provided] Yes N/A Warranty Comprehensive warranty of 3 years with free servicing ( N/A 5/7 min 3/year) during warranty Operating manuals | - | - | - |
| service manuals | - | - | - |
| other manuals/documents Advanced maintenance tasks required shall be documented User | - | - | - |
| technical and maintenance manuals to be supplied in English language. List to be provided of equipment and procedures required for local calibration and routine maintenance List to be provided of important spares and accessories | - | - | - |
| with their part numbers. Certificate of calibration and inspection to be provided. N/A Recommendations or warnings Any recommendations for best use and supplimentary warning for safety to be declared N/A Details of Item and test reports Availability of Test Report from Central Govt/NABL/ILAC/Any OPCW accredited lab to prove conformity to specification No N/A Test report (if indicated as available) to be furnished to buyer on demand YES N/A Test report No & date CE-2884 DATE 6/1/2017 N/A Name and address of the Lab: UK CERTIFICATION AND INSPECTION LIMITED | - | - | - |
| UK N/A * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Sanjeev Kumar 801507 | - | - | - |
| AIIMS | - | - | - |
| Phulwarisarif | - | - | - |
| PATNA PIN-851507 50 15 EMD 6/7 Required No ePBG Required No | - | - | - |
Exempted
14 May 2018
30 Apr 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_44580.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .